Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Physiol ; 597(5): 1337-1346, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30552684

RESUMO

KEY POINTS: Intense physical activity, a potent stimulus for sympathetic nervous system activation, is thought to increase the risk of malignant ventricular arrhythmias among patients with hypertrophic cardiomyopathy (HCM). As a result, the majority of patients with HCM deliberately reduce their habitual physical activity after diagnosis and this lifestyle change puts them at risk for sequelae of a sedentary lifestyle: weight gain, hypertension, hyperlipidaemia, insulin resistance, coronary artery disease, and increased morbidity and mortality. We show that plasma catecholamine levels remain stably low at exercise intensities below the ventilatory threshold, a parameter that can be defined during cardiopulmonary exercise testing, but rise rapidly at higher intensities of exercise. These findings suggest that cardiopulmonary exercise testing may be a useful tool to provide an individualized moderate-intensity exercise prescription for patients with HCM. ABSTRACT: Intense physical activity, a potent stimulus for sympathetic nervous system activation, is thought to increase the risk of malignant ventricular arrhythmias among patients with hypertrophic cardiomyopathy (HCM). However, the impact of exercise intensity on plasma catecholamine levels among HCM patients has not been rigorously defined. We conducted a prospective observational case-control study of men with non-obstructive HCM and age-matched controls. Laboratory-based cardiopulmonary exercise testing coupled with serial phlebotomy was used to define the relationship between exercise intensity and plasma catecholamine levels. Compared to controls (C, n = 5), HCM participants (H, n = 9) demonstrated higher left ventricular mass index (115 ± 20 vs. 90 ± 16 g/m2 , P = 0.03) and maximal left ventricular wall thickness (16 ± 1 vs. 8 ± 1 mm, P < 0.001) but similar body mass index, resting heart rate, peak oxygen consumption (H = 40 ± 13 vs. C = 42 ± 7 ml/kg/min, P = 0.81) and heart rate at the ventilatory threshold (H = 78 ± 6 vs. C = 78 ± 4% peak heart rate, P = 0.92). During incremental effort exercise in both groups, concentrations of adrenaline and noradrenaline were unchanged through low- and moderate-exercise intensity until reaching a catecholamine threshold (H = 82 ± 4 vs. C = 85 ± 3% peak heart rate, P = 0.86) after which levels of both molecules rose rapidly. In patients with mild non-obstructive HCM, plasma catecholamine levels remain stably low at exercise intensities below the ventilatory threshold but rise rapidly at higher intensities of exercise. Routine cardiopulmonary exercise testing may be a useful tool to provide an individualized moderate-intensity exercise prescription for patients with HCM.


Assuntos
Cardiomiopatia Hipertrófica/reabilitação , Epinefrina/sangue , Terapia por Exercício , Norepinefrina/sangue , Adulto , Cardiomiopatia Hipertrófica/sangue , Cardiomiopatia Hipertrófica/fisiopatologia , Exercício Físico/fisiologia , Teste de Esforço , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Adulto Jovem
2.
J Am Soc Echocardiogr ; 31(4): 491-504, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28843367

RESUMO

Isolated reoperative tricuspid valve replacement is one of the highest risk operations classified in the Society of Thoracic Surgeons registry, particularly in the setting of preexisting right ventricular dysfunction. Transcatheter tricuspid valve-in-valve implantation represents an attractive alternative to redo surgery in patients with tricuspid bioprosthetic valve degeneration who are considered high-risk or unsuitable surgical candidates. In this review article, the authors discuss the emergence of transcatheter tricuspid valve-in-valve therapy, preprocedural echocardiographic assessment of tricuspid bioprosthetic valve dysfunction, periprocedural imaging required for tricuspid valve-in-valve implantation, and postprocedural assessment of tricuspid transcatheter device function.


Assuntos
Bioprótese/efeitos adversos , Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Tricúspide/cirurgia , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Valva Tricúspide/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA