Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Foot Ankle Surg ; 61(6): 1203-1208, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35307281

RESUMO

The modified "Lapidus" procedure (MLP) describes the arthrodesis of the first tarsometatarsal joint. We investigate if there are detectable changes of the tendon or the function of the muscle and clinical outcome after MLP. We reviewed 22 feet. All patients underwent magnetic resonance imaging (MRI) at an average of 27 (range, 12-49) months. Clinical outcome was evaluated using the European Foot and Ankle Society score. Strength was measured and complications were assessed. MRI revealed signs of tendinopathy of the tibialis anterior tendon in 13 feet (59%). The mean total European Foot and Ankle Society score at final follow-up was 17 (range, 6-24) points. The mean postoperative Visual Analog Scale score was 1.4 (range, 0-5). Range of motion and force data were not significantly different to the contralateral side. In conclusion, MRI showed signs of tendinopathy in 59%, which does not seem to affect clinical outcome, but has to be considered when choosing the desired implant and placement. MLP leads to high patient satisfaction rates and significant improvement at midterm follow up.

2.
Spine Surg Relat Res ; 5(6): 347-351, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34966859

RESUMO

INTRODUCTION: Despite being originally developed for the evaluation of lumbar disk degeneration, the Pfirrmann classification has emerged as the most popular classification system for cervical disk degeneration. However, with the Suzuki classification, a new classification system that is specifically tailored for the evaluation of cervical disk disease was introduced. In this study, we aim to evaluate differences in inter- and intraobserver reliability of both classifications in a head-to-head comparison. METHODS: In total, we have evaluated 120 cervical disks within 40 patients via magnetic resonance imaging according to the Pfirrmann and Suzuki classification. The degree of disk degeneration was evaluated by two independent musculoskeletal radiologists. After 6 months, the classification was reassessed to evaluate the intraobserver reliability. The inter- and intraobserver reliabilities were then calculated using Cohen's kappa. RESULTS: The inter- and intraobserver reliability provided a significant agreement between all ratings in Pfirrmann as well as the Suzuki classification (p>0.001). The interobserver reliability was determined to be fair in both the Suzuki classification (κ=0.290) and the Pfirrmann classification (κ=0.265). The intraobserver reliability was substantial in the Suzuki classification (κ=0.798), while it was almost perfect in the Pfirrmann classification (κ=0.858). CONCLUSIONS: Although not designed for the evaluation of cervical disk degeneration, the Pfirrmann classification yielded equal inter- and higher intraobserver reliability. Both classification systems are viable options for the grading of cervical disk degeneration. While the Pfirrmann classification has the advantage of being better established, the Suzuki classification may be clinically superior due to a better representation of cervical disk degeneration and the consideration of disk bulging for the classification of cervical disk degeneration.

3.
Children (Basel) ; 8(8)2021 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-34438526

RESUMO

BACKGROUND: Recommended treatment for severely displaced proximal humeral fractures in children is the closed reduction and percutaneous fixation by K-wires or intramedullary nailing. METHODS: From January 2016 to January 2017 6, 21 children/adolescents (range 8 to 16 years) with proximal humeral fractures were treated surgically for severe displacement. In these six patients, several attempts of closed reduction were unsuccessful, and an open reduction was performed. The humeral head was fixed with a 3.5 mm T-plate without affecting the growth plate. Plate removal was performed at a mean interval of 132 days after initial surgery. Two years after initial surgery, the clinical outcome was assessed by the Constant-Murley score and QuickDASH score (including sport/music and work) and the shoulder joint was evaluated with a standardized sonographic examination for the rotator cuff and the conjoint tendon. RESULTS: In all six patients, dorsal displacement of the fracture was irreducible due to the interposition of tendinous or osseous structures. Intraoperatively, the interposed structures were the long biceps tendon in two, periosteal tissue in two, a bony fragment in one, and the long biceps tendon together with the conjoint tendon in one case. At mean follow-up of 26 months (range 22 months to 29 months), patients showed very good clinical results with an excellent mean Constant-Murley score of 97.5 (range 91 to 100) and mean QuickDASH score (including sport/music and work) of 5.5 (range 0-20.8). An X-ray follow-up 6 weeks after surgery demonstrated early consolidation and correct alignment in all patients. A sonographic evaluation at 2 years post injury showed that the biceps and the conjoined tendon were intact in all patients. CONCLUSIONS: If a proximal humeral fracture is not reducible by closed means, a tissue entrapment (most likely biceps tendon) should be considered. Treatment with an open reduction and plate fixation yields very good clinical and radiological results and preserves interposed structures as the biceps and conjoint tendon.

4.
Knee Surg Sports Traumatol Arthrosc ; 29(1): 90-99, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31563990

RESUMO

PURPOSE: Collagen meniscal implants (CMI) have variable imaging findings on MRI and it remains ambiguous, if alterations may be present in asymptomatic patients. The aim was, to evaluate MR morphological characteristics and volume of CMI in the early, mid- and long-term follow-up. METHODS: Fifty-seven patients (mean age, 43.6±11 years; 41 male/16 female) with good clinical outcome (subjective visual analogue scale for satisfaction < 2 and a Lysholm-score ≥ 84) after CMI were assessed retrospectively using MRI 1, 2 and 3-8 years postoperatively. CMI morphology, signal intensity (SI), homogeneity and size were assessed and a meniscal score was calculated. Chondral defects and bone marrow edema pattern were reported and summarized in a chondral score. Meniscal extrusion and volume were evaluated. Intra- and inter-reader reliabilities were calculated. Spearman and partial correlations were used (p < 0.05). RESULTS: One year postoperatively, the CMI varied in size [10% (4/40) normal, 30% (12/40) small, 60% (24/40) hypertrophic] and was hyperintense and inhomogeneous in all patients. At long-term follow-up, the size of CMI decreased [6% (1/17) resorbed, 18% (3/17) normal, 41% (7/17) small, 35% (6/17) hypertrophic]. The SI of the CMI changed to normal in only 13% (2/16). The majority was still hyperintense [87% (14/16)]. Less meniscal extrusion was present in the follow-up [71% (11/16) versus initially 93% (37/40)]. The meniscal score improved significantly (ρ = 0.28). Over time, full-thickness femoral chondral defects were increasingly present [65% (10/17) versus initially 33% (13/40)] and the chondral score worsened significantly (p = 0.017). CONCLUSION: Abnormal and inhomogeneous SI and irregular margins of the early postoperative CMI on MRI are findings seen in patients with good clinical results and should not necessarily be overcalled when reporting MRI. These features tend to decrease over time. LEVEL OF EVIDENCE: IV.


Assuntos
Colágeno/uso terapêutico , Meniscos Tibiais/cirurgia , Implantação de Prótese/métodos , Adulto , Doenças da Medula Óssea/epidemiologia , Cartilagem Articular/patologia , Edema/epidemiologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Meniscos Tibiais/diagnóstico por imagem , Menisco/cirurgia , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento
5.
Clin Neurol Neurosurg ; 200: 106332, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33176971

RESUMO

PURPOSE: Anterior cervical decompression surgery exposes the vertebral artery to the risk of injury. This risk can increase if the natural course of the vertebral artery is altered. Therefore, this study evaluated if the distance between surgical landmarks and the vertebral artery decrease with the progression of cervical disc degeneration. METHODS: This study analyzed 40 patients with cervical magnetic resonance imaging. We evaluated the distance between the uncinate process and the vertebral artery in axial-plane T2 weighted sequences of the cervical levels C3-C6. The cervical disc degeneration was graded according to the Pfirrmann- and Suzuki classification. The decrease of the distance was evaluated using a one-way ANOVA. RESULTS: The distance between the uncinate process and the vertebral artery decreased with increasing disc degeneration (p ≤ 0.015). ROC analysis provided an acceptable area under the curve in both classifications for the detection of a vertebral artery to the uncinate process distance of zero. The presence of Pfirrmann grade V had a positive predictive value of 69% for the presence of contact between the uncinate process and the vertebral artery. CONCLUSION: High-grade cervical disc degeneration according to the Pfirrmann- and the Suzuki classification decrease the distance between the uncinate process and the vertebral artery. High-grade disc degeneration therefore should raise the awareness of the surgeon for the loss of the distance between surgical landmarks and the vertebral artery. However, screening for high-grade disc degeneration alone cannot substitute the thorough evaluation of the anatomical course of the vertebral artery before surgery.


Assuntos
Pontos de Referência Anatômicos/diagnóstico por imagem , Vértebras Cervicais/diagnóstico por imagem , Degeneração do Disco Intervertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Procedimentos de Cirurgia Plástica/métodos , Artéria Vertebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos/anatomia & histologia , Vértebras Cervicais/cirurgia , Feminino , Humanos , Degeneração do Disco Intervertebral/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Artéria Vertebral/anatomia & histologia , Adulto Jovem
6.
Radiology ; 290(3): 752-759, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30620259

RESUMO

Purpose To compare the radiation exposure for participants and interventionalists as well as participant outcomes between fluoroscopy-guided versus CT-guided lumbar spinal injections. Materials and Methods This prospective, nonrandomized observational study included 1446 participants (mean age, 60.6 years; range, 18-91 years) who received transforaminal epidural injections or facet joint injections under fluoroscopic or CT guidance between October 2009 and April 2016. Effective doses were estimated by conversion from dose-area product for fluoroscopy-guided injections and dose-length product for CT-guided injections. Radiation exposure for interventionalists was measured with dosimeters at the body and wrist. The Patient Global Impression of Change (PGIC) scale was used to assess clinical participant outcomes at 1 day, 1 week, and 1 month after lumbar spine injections. Student t and χ2 tests were used for statistical analysis. Results The mean effective participant dose for fluoroscopy-guided lumbar transforaminal epidural injections was 0.24 mSv ± 0.22, compared with 0.33 mSv ± 0.10 for CT-guided injections (P < .003). The mean effective participant dose for fluoroscopy-guided lumbar facet joint injections was 0.10 mSv ± 0.11, compared with 0.33 mSv ± 0.13 for CT-guided injections (P < .001). Radiation exposure for the interventionalist was higher during fluoroscopy-guided compared with CT-guided lumbar transforaminal epidural injections (body: 0.42 × 10-3 mSv ± 0.99 vs 0.11 × 10-3 mSv ± 0.44, P < .03; wrist: 1.44 × 10-3 mSv ± 2.69 vs 0.14 × 10-3 mSv ± 0.55, P < .001). Radiation exposure of the wrist for the interventionalist was higher during fluoroscopy-guided compared with CT-guided lumbar facet injections (0.46 × 10-3 mSv ± 0.93 vs 0.06 × 10-3 mSv ± 0.24, respectively; P < .006). Clinical participant outcomes as determined with the PGIC scale did not differ between fluoroscopy-guided and CT-guided injections (P = .15-.96). Conclusion Radiation exposure in fluoroscopy-guided lumbar spinal injections was lower for participants and higher for physicians when compared with CT-guided injections; however, no associations were observed between clinical participant outcomes and type of imaging-guided injection technique at all evaluated time points. © RSNA, 2019.


Assuntos
Fluoroscopia , Injeções Epidurais , Região Lombossacral , Exposição à Radiação , Radiografia Intervencionista , Esteroides/administração & dosagem , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional , Estudos Prospectivos
7.
AJR Am J Roentgenol ; 211(1): 155-161, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29733696

RESUMO

OBJECTIVE: The objective of our study was to evaluate a novel measurement technique for assessing the supra- and infratrochanteric components of femoral torsion, establish reference values in healthy volunteers, and compare supra- and infratrochanteric torsion angles in patients with hip dysplasia and patients with femoroacetabular impingement (FAI) with those in healthy volunteers. MATERIALS AND METHODS: Femoral torsion was assessed in 380 patients and 61 healthy volunteers on MRI. For assessing supra- and infratrochanteric torsion, three measurement techniques (i.e., Kim, simplified Kim, and centroid methods) were evaluated by two readers on 100 patients. The technique with the highest interreader reliability was selected to perform measurements on all patients and volunteers. Supra- and infratrochanteric torsion angles of patients were stratified by hip disorders, which were diagnosed by specialized hip surgeons, and were compared with reference values of healthy volunteers. Statistical analysis included the independent t test, Mann-Whitney U test, and intraclass correlation coefficient (ICC). RESULTS: The centroid method showed the highest interreader reliability for measuring supra-and infratrochanteric torsion with an ICC of 0.979. The supra- and infratrochanteric torsion values of the volunteers were 31.5° ± 7.4° (mean ± SD) and -18.3° ± 9.9°, respectively. In comparison with the volunteers, patients with hip dysplasia had significantly higher supraand infratrochanteric torsion values of 37.5° ± 10.3° (p = 0.001) and -9.6° ± 11.7° (p < 0.001) and patients with pincer-type FAI had significantly higher supratrochanteric torsion values of 37.8° ± 8.0° (p = 0.002). CONCLUSION: The supra- and infratrochanteric components of femoral torsion differ substantially between hip disorders: Patients with hip dysplasia have predominantly increased infratrochanteric torsion, whereas patients with pincer-type FAI have increased supratrochanteric torsion. Quantification of separate supra- and infratrochanteric torsion angles allows a more detailed analysis of hip disorders and may influence treatment planning.


Assuntos
Mau Alinhamento Ósseo/diagnóstico por imagem , Impacto Femoroacetabular/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Luxação do Quadril/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Anormalidade Torcional/diagnóstico por imagem , Adulto , Mau Alinhamento Ósseo/etiologia , Mau Alinhamento Ósseo/fisiopatologia , Estudos de Casos e Controles , Feminino , Impacto Femoroacetabular/complicações , Impacto Femoroacetabular/fisiopatologia , Fêmur/fisiopatologia , Luxação do Quadril/complicações , Luxação do Quadril/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Anormalidade Torcional/etiologia , Anormalidade Torcional/fisiopatologia
8.
J Shoulder Elbow Surg ; 25(1): 31-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26234662

RESUMO

BACKGROUND: The quantification of a subscapularis tendon lesion may be difficult on magnetic resonance imaging, as well as during arthroscopic inspection. Consequently, the surgical decision of whether to only debride a degenerated tendon or to lateralize the more intact tendon portion may be arbitrary. This study aims to quantify the length of the subscapularis tendon as a sign of partial tendon tearing. METHODS: We retrospectively identified 92 magnetic resonance arthrography studies of suspected rotator cuff lesions obtained 3 months before shoulder arthroscopy. The myotendinous junction was identified, and the subscapularis tendon and muscle lengths were measured. Findings on arthroscopy performed later were used as the diagnostic gold standard for tendon integrity and compared with the magnetic resonance data. RESULTS: Arthroscopy showed an intact subscapularis tendon in 43 patients, tendinopathy in 21 patients, and a partial rupture in 28 patients. The mean subscapularis tendon lengths were 40 mm in cases of intact subscapularis musculotendinous units, 45 mm in cases of tendinopathy, and 53 mm in cases of partial tears, whereas the mean subscapularis muscle lengths were 105 mm, 94 mm, and 95 mm, respectively, in these groups. CONCLUSION: Partial tears of the subscapularis tendon lead to muscle shortening by approximately 10% and elongation of the tendon by approximately 32%, which may be interpreted as muscle retraction and a tendon rupture in continuity. If the subscapularis tendon has an apparent length of greater than 60 mm, the probability of a tear is 98%. Determination of the tendon length may therefore be a useful additional tool to quantify the integrity of the subscapularis tendon and degree of myotendinous retraction.


Assuntos
Lacerações/diagnóstico , Lesões do Manguito Rotador , Manguito Rotador/patologia , Traumatismos dos Tendões/diagnóstico , Artroscopia/métodos , Feminino , Humanos , Lacerações/cirurgia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Retrospectivos , Ruptura/diagnóstico , Ruptura/cirurgia , Tendinopatia/diagnóstico , Tendinopatia/cirurgia , Traumatismos dos Tendões/cirurgia
9.
Eur Radiol ; 25(11): 3405-13, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25903715

RESUMO

PURPOSE: To investigate long-term pain reduction and 'improvement' in patients with indirect cervical nerve-root-blocks in comparison to MRI findings. MATERIAL AND METHODS: One hundred and twelve patients with MRI confirmed cervical radiculopathy and an indirect cervical nerve-root-block were included. Two radiologists independently evaluated the MRI examinations. 12 different MRI abnormalities at the level and side of infiltration were compared to pain relief and 'improvement' at 1-month, 3-months and 1-year post injection. RESULTS: The proportion of patients reporting clinically relevant 'improvement' was 36.7% at 1-month, 53.9% at 3-months and 68.1% at 1-year. At 1-month post injection, a statistically significantly lower percentage of patients eventually requiring surgery reported improvement and lower NRS change scores compared to those who did not undergo surgery (p = 0.001). Patients with extrusion of the disc were around 4-times more likely to have surgery. At 1-year post-injection the presence of nerve-root compromise was significantly linked to treatment outcome (p = 0.011). CONCLUSION: Patients with nerve root compression were more likely to report improvement at 1 year. Patients with disc extrusions have less pain relief and are 4 times more likely to go to surgery than patients with disc protrusions. KEY POINTS: • Good long term outcomes after indirect nerve root infiltrations with non-particulate steroids. • The presence of nerve root compression was a predictive finding of 'improvement'. • Significantly less patients subsequently having surgery had lower NRS scores 1-month post injection. • There is less pain relief in patients with disc extrusions. • There are less improvement in patients with modic type I changes.


Assuntos
Cervicalgia/prevenção & controle , Bloqueio Nervoso/métodos , Radiculopatia/terapia , Raízes Nervosas Espinhais , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Manejo da Dor , Medição da Dor , Estudos Prospectivos , Radiculopatia/complicações , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
Invest Radiol ; 44(12): 793-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19884825

RESUMO

OBJECTIVE: The detection rate of pulmonary emboli (PE) with computed tomography angiography (CTA) using either a standard or a low-dose protocol, combining reduced radiation exposure and iodine delivery rate, was retrospectively analyzed in a matched cohort of 120 patients. MATERIALS AND METHODS: The study was performed according to the regulations of the institutional review board. Four groups of 30 patients each, with a body weight of less than 100 kg and receiving pulmonary CTA were matched by age (range, 21-87 years), gender (female/male, 48/72), weight (range, 41-99 kg), and cross sectional area of the chest (range, 468-885 cm2). Sixty patients had PE and 60 patients had no PE at CTA. The CT tube voltage was either 80 kVp (group A, with PE and group B, with no PE) or 120 kVp (group C, with PE and group D, with no PE). Volume and flow rate of injected contrast medium was lower with the 80 kVp protocol (75 mL at 3 mL/s) compared with the 120 kVp protocol (100 mL at 4 mL/s). Contrast-to-noise ratio (CNR) for the pulmonary trunk was calculated. Two independent readers analyzed all CTAs in a randomized order for the localization of emboli, diagnostic confidence, and image quality. The reference standard for the presence of emboli involved consensus reading and assessment of available clinical data and findings with additional imaging modalities. CNR, subjective image quality, diagnostic confidence, sensitivity, and specificity for emboli at both tube voltages were compared. RESULTS: All patients with PE were correctly identified with both protocols, corresponding to a sensitivity of 100% at the patient level. For the localizations with emboli, both the sensitivity (83.7% at 80 kVp and 83.6% at 120 kVp; P = 0.921) and the specificity (97.2% at 80 kVp and 97.8% at 120 kVp; P = 0.463) were not significantly different at the 2 tube voltages. The diagnostic confidence was not different at all ramification levels (P = 0.216-1.0). CNR did not differ between the groups (P = 0.202). The overall subjective image quality was higher at 120 kVp compared with 80 kVp (P = 0.017). CONCLUSION: Detection rate and diagnostic confidence for the presence of pulmonary emboli with low-dose pulmonary CTA using 80 kVp and reduced iodine delivery rate may be equal to that at 120 kVp in patients weighing less than 100 kg.


Assuntos
Angiografia/métodos , Carga Corporal (Radioterapia) , Meios de Contraste/administração & dosagem , Embolia Pulmonar/diagnóstico por imagem , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA