Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pediatr Cardiol ; 44(1): 132-140, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36029321

RESUMO

The aim of the study was to determine the variables associated with high-quality (HQ) versus low-quality (LQ) three-dimensional rotational angiography (3DRA) and create guides for optimization of approach to 3DRA in congenital cardiac catheterization (CCC). CCC has adopted 3DRA as a mainstay, but there has not been systematic analysis of approach to and factors associated with HQ 3DRA. This was a single-center, retrospective study of 3DRAs using Canon Infinix-I platform. Reconstructions were graded by 3 interventionalists. Quality was dichotomized into HQ and LQ. Univariable analyses and multivariable logistic regression models were performed. From 8/2016 to 12/2018, 208 3DRAs were performed in 195 CCCs; median age 7 years (2, 16), weight 23 kg (12, 57). The majority of 3DRAs were performed in patients with biventricular physiology (N = 137, 66%) and in pulsatile sites (N = 144, 69%). HQ 3DRA (N = 182, 88%) was associated with greater total injection volume [2.20 mL/kg (1.44, 3.29) vs. 1.62 mL/kg (1.10, 1.98), p = 0.005] and more dilute contrast solution [60% (50, 100) vs. 100% (60, 100), p = 0.007], but not with contrast volume administered (p = 0.2) on univariable analysis. On multivariable logistic regression, HQ 3DRA was significantly associated with patient weight [OR 0.97 (95% CI (0.94, 0.99), p = 0.018], total injection volume [OR 1.04 (95% CI 1.01, 1.07) p = 0.011], and percent contrast solution [OR 0.97 (95% CI 0.95, 1.00), p = 0.022]. These data resulted in creation of scatter plots and a novel 3DRA Nomogram for estimating the probability of HQ 3DRA. This is the first study to create evidence-based contrast dose guides and nomogram for 3DRA in CCC. HQ 3DRA was associated with lower weight, higher total injection volumes, and more dilute contrast solution.


Assuntos
Imageamento Tridimensional , Procedimentos de Cirurgia Plástica , Humanos , Criança , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Angiografia/métodos , Cateterismo Cardíaco/métodos
2.
Commun Med (Lond) ; 2: 3, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35603301

RESUMO

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

3.
Circ Cardiovasc Interv ; 15(1): e010852, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34930015

RESUMO

BACKGROUND: The Melody valve was developed to extend the useful life of previously implanted right ventricular outflow tract (RVOT) conduits or bioprosthetic pulmonary valves, while preserving RV function and reducing the lifetime burden of surgery for patients with complex congenital heart disease. METHODS: Enrollment for the US Investigational Device Exemption study of the Melody valve began in 2007. Extended follow-up was completed in 2020. The primary outcome was freedom from transcatheter pulmonary valve (TPV) dysfunction (freedom from reoperation, reintervention, moderate or severe pulmonary regurgitation, and/or mean RVOT gradient >40 mm Hg). Secondary end points included stent fracture, catheter reintervention, surgical conduit replacement, and death. RESULTS: One hundred seventy-one subjects with RVOT conduit or bioprosthetic pulmonary valve dysfunction were enrolled. One hundred fifty underwent Melody TPV replacement. Median age was 19 years (Q1-Q3: 15-26). Median discharge mean RVOT Doppler gradient was 17 mm Hg (Q1-Q3: 12-22). The 149 patients implanted >24 hours were followed for a median of 8.4 years (Q1-Q3: 5.4-10.1). At 10 years, estimated freedom from mortality was 90%, from reoperation 79%, and from any reintervention 60%. Ten-year freedom from TPV dysfunction was 53% and was significantly shorter in children than in adults. Estimated freedom from TPV-related endocarditis was 81% at 10 years (95% CI, 69%-89%), with an annualized rate of 2.0% per patient-year. CONCLUSIONS: Ten-year outcomes from the Melody Investigational Device Exemption trial affirm the benefits of Melody TPV replacement in the lifetime management of patients with RVOT conduits and bioprosthetic pulmonary valves by providing sustained symptomatic and hemodynamic improvement in the majority of patients. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00740870.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Adolescente , Adulto , Humanos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
4.
J Am Coll Cardiol ; 76(24): 2847-2858, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33303074

RESUMO

BACKGROUND: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve. OBJECTIVES: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve. METHODS: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve. Patient-related, procedural, and short-term outcomes data were characterized overall and according to type of right ventricular outflow tract (RVOT) anatomy. RESULTS: Twenty-three centers enrolled a total of 774 patients: 397 (51%) with a native/patched RVOT; 183 (24%) with a conduit; and 194 (25%) with a bioprosthetic valve. The S3 was used in 78% of patients, and the XT was used in 22%, with most patients receiving a 29-mm (39%) or 26-mm (34%) valve. The implant was technically successful in 754 (97.4%) patients. Serious adverse events were reported in 67 patients (10%), with no difference between RVOT anatomy groups. Fourteen patients underwent urgent surgery. Nine patients had a second valve implanted. Among patients with available data, tricuspid valve injury was documented in 11 (1.7%), and 9 others (1.3%) had new moderate or severe regurgitation 2 grades higher than pre-implantation, for 20 (3.0%) total patients with tricuspid valve complications. Valve function at discharge was excellent in most patients, but 58 (8.5%) had moderate or greater pulmonary regurgitation or maximum Doppler gradients >40 mm Hg. During limited follow-up (n = 349; median: 12 months), 9 patients were diagnosed with endocarditis, and 17 additional patients underwent surgical valve replacement or valve-in-valve TPVR. CONCLUSIONS: Acute outcomes after TPVR with balloon-expandable valves were generally excellent in all types of RVOT. Additional data and longer follow-up will be necessary to gain insight into these issues.


Assuntos
Procedimentos Endovasculares/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Próteses Valvulares Cardíacas , Valva Pulmonar , Sistema de Registros , Adolescente , Adulto , Bioprótese , Criança , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
5.
Catheter Cardiovasc Interv ; 95(2): 270-279, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31609082

RESUMO

OBJECTIVE: We describe the technical considerations of transcatheter implantation of the CardioMEMS™ HF System (Abbott, Abbott Park, IL) in adult patients with complex palliated congenital heart disease (CHD) and advanced heart failure (HF). BACKGROUND: Ambulatory pulmonary artery (PA) pressure monitoring with implantable hemodynamic monitors (IHMs) has been shown to reduce HF-related hospital admissions in non-CHD populations. HF is a common late cardiovascular complication in adult CHD necessitating better understanding of IHM application in this population. METHODS: We analyzed adults with complex CHD and advanced HF who were referred for CardioMEMS™ device implantation (2015-2018). Feasibility of device implantation, defined by successful device implantation and calibration, and procedural outcomes were evaluated. RESULTS: CardioMEMS™ was successfully implanted in all 14 adults (35.5 ± 9.2 years old, 72 ± 12 kg) with complex CHD (single ventricle/Fontan, n = 8 [57%]; d-transposition of the great arteries/atrial switch, n = 6 [43%]). The device was delivered via femoral venous access in 13 (93%) patients and implanted in the left PA in 12 (86%). A long sheath was used in 8 (57%) patients, including 5/6 with an atrial switch operation. There was one device migration that did not require retrieval. CONCLUSIONS: Transcatheter implantation of an IHM is feasible in select complex adult CHD patients with advanced HF. Further studies evaluating integration of ambulatory hemodynamics and the impact on clinical care are needed. This technology has the potential to improve medical management of advanced HF in patients with Fontan and atrial switch physiologies and provide new insights into their ambulatory hemodynamics.


Assuntos
Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca/diagnóstico , Cuidados Paliativos , Artéria Pulmonar/fisiopatologia , Tecnologia de Sensoriamento Remoto/instrumentação , Adulto , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
Catheter Cardiovasc Interv ; 94(3): 416-421, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31276274

RESUMO

The Gore Viabahn VBX balloon-expandable endoprosthesis (W. L. Gore & Associates, Flagstaff, AZ) is a flexible covered stent that is FDA-approved for the treatment of iliac artery stenosis, including lesions at the aortic bifurcation. In this case series, we report the first use of the VBX covered stent in congenital heart disease, highlighting several of its unique advantages.


Assuntos
Angioplastia com Balão/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cardiopatias Congênitas/cirurgia , Cuidados Paliativos , Doenças Vasculares Periféricas/cirurgia , Stents , Adulto , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Humanos , Recém-Nascido , Masculino , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/fisiopatologia , Desenho de Prótese , Resultado do Tratamento
7.
J Cardiovasc Transl Res ; 10(2): 128-138, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28097523

RESUMO

Patients who undergo implantation of a tissue-engineered vascular graft (TEVG) for congenital cardiac anomalies are monitored with echocardiography, followed by magnetic resonance imaging or angiography when indicated. While these methods provide data regarding the lumen, minimal information regarding neotissue formation is obtained. Intravascular ultrasound (IVUS) has previously been used in a variety of conditions to evaluate the vessel wall. The purpose of this study was to evaluate the utility of IVUS for evaluation of TEVGs in our ovine model. Eight sheep underwent implantation of TEVGs either unseeded or seeded with bone marrow-derived mononuclear cells. Angiography, IVUS, and histology were directly compared. Endothelium, tunica media, and graft were identifiable on IVUS and histology at multiple time points. There was strong agreement between IVUS and angiography for evaluation of luminal diameter. IVUS offers a valuable tool to evaluate the changes within TEVGs, and clinical translation of this application is warranted.


Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Transplante de Medula Óssea , Engenharia Tecidual/métodos , Alicerces Teciduais , Ultrassonografia de Intervenção , Veia Cava Inferior/cirurgia , Animais , Implante de Prótese Vascular/efeitos adversos , Células Cultivadas , Modelos Animais , Flebografia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/patologia , Desenho de Prótese , Carneiro Doméstico , Fatores de Tempo , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/patologia
8.
Interact Cardiovasc Thorac Surg ; 21(2): 249-51, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25972598

RESUMO

In the recent era, the diagnosis, treatment options, postoperative management and outcomes of infants born with hypoplastic left heart syndrome (HLHS) have undergone dramatic changes. As is the case with many other novel treatment modalities used for congenital heart diseases, data concerning the long-term outcomes and complications of the various strategies become gradually more available as the numbers of survivors grow. In general, complications of the three-stage surgical palliation used for HLHS tend to occur most commonly following the first-stage surgery. Post-stage 2 complications are substantially less common, and centre on the procedure itself and the unique physiology of the cavopulmonary connection. In the following case report, we describe a relatively rare adverse outcome that occurred following a stage 2 surgery in the form of native aortic root thrombosis extending to the coronary arteries. The selected methods of treatment used in the catheterization laboratory and later in the operating theatre, as well as its outcomes are described.


Assuntos
Doenças da Aorta/etiologia , Oclusão Coronária/etiologia , Embolia/etiologia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Trombose/etiologia , Arritmias Cardíacas/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Lactente
9.
Catheter Cardiovasc Interv ; 80(6): 922-30, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22419358

RESUMO

BACKGROUND: Bi-plane angiography is the gold standard for imaging the pulmonary arteries (PAs) after cavo-pulmonary connection (CPC). Three-dimensional rotational angiography (3DRA) is emerging technology that we hypothesized may enhance diagnostic capabilities in this patient group. METHODS: Retrospective review of patients who underwent 3DRA to assess the PAs after CPC. 3DRA images were examined for diagnostic quality and compared, both qualitatively and quantitatively with corresponding 2D images. RESULTS: Between 1/2010 and 12/2010, 37 3DRAs were obtained in 32 pts with prior CPC. Median age and weight were 4.3 years (0.3-19) and 15.7 kg (4.3-114). Previous surgery included: bi-directional Glenn (16), bilateral bi-directional Glenn (2), and Fontan (14). Thirty-three (89%) acquisitions in 28 pts were of diagnostic quality. In 19/28 pts (68%) 3DRA provided significant additional information pertaining to 22 lesions when compared with bi-plane angiography. These included delineating the mechanism of PA stenosis in 13 (aortic compression: 7, PA torsion: 6), demonstrating a discrete PA stenosis not seen or under appreciated on corresponding 2D images in 9. This additional information led to the performance of 9 interventions (stent implantation 8, angioplasty 1). Corresponding 2D and 3DRA images of the right and left PA were compared using quantitative analysis with a correlation coefficient of 0.94 (P < 0.001) and 0.97 (P < 0.001), for the right and left PAs respectively. CONCLUSIONS: 3DRA can be performed safely and effectively following CPC and may be more sensitive in diagnosing PA stenoses than 2D angiography. Quantitative measurements of PA diameter using 3DRA correlates well with 2D angiography.


Assuntos
Angiografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Derivação Cardíaca Direita , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/cirurgia , Imageamento Tridimensional , Artéria Pulmonar/cirurgia , Circulação Pulmonar , Interpretação de Imagem Radiográfica Assistida por Computador , Adolescente , Angioplastia/instrumentação , Arteriopatias Oclusivas/etiologia , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/terapia , Criança , Pré-Escolar , Constrição Patológica , Derivação Cardíaca Direita/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Stents , Resultado do Tratamento , Adulto Jovem
10.
Pediatr Cardiol ; 31(7): 1089-92, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20508924

RESUMO

Takayasu's arteritis is a granulomatous giant-cell arteritis of the aorta and its major branches. It primarily affects East Asian women in their second or third decade of life but is well known to affect all ethnicities across the world. Given its systemic nature, Takayasu's arteritis has multiorgan involvement, with the majority of disease morbidity related to the cardiovascular, central nervous, and renal systems. This report describes an unusual presentation of Takayasu's arteritis in a 2½-year-old boy. This is the first report in the literature describing the presence of both severe aortic regurgitation and diffuse coronary artery involvement in a patient so young.


Assuntos
Arterite de Takayasu/diagnóstico , Pré-Escolar , Humanos , Imageamento por Ressonância Magnética , Masculino , Índice de Gravidade de Doença
11.
J Ultrasound Med ; 28(7): 889-99, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19546331

RESUMO

OBJECTIVE: The purpose of this study was to determine the relative importance of the 4-chamber view (4CV) compared with the outflow tract views (OFTVs) in prenatal screening for major congenital heart disease (CHD). METHODS: We prospectively evaluated 200 consecutive infants undergoing cardiac surgery at our institution for major CHD. By reviewing the infants' medical records and conducting bedside interviews with their parents or guardians, we evaluated detection rates both prenatally and postnatally (before and after discharge to home), and we noted any prenatally identifiable risk factors for CHD. For each infant, we determined whether the 4CV or OFTVs would be expected to have been normal or abnormal on routine midgestation screening fetal sonography. RESULTS: A prenatal diagnosis of CHD was made in 65 infants (33%): 30 of 124 low-risk pregnancies (24%) and 35 of 76 high-risk pregnancies (46%). An abnormal screening midgestation 4CV would have been expected in up to 63% of the infants, whereas abnormal midgestation OFTVs would have been expected in up to 91% of the infants. Thus, the potential sensitivity for detecting major CHD was higher with the OFTVs than with the 4CV (91% versus 63%; P < .001). Moreover, the OFTVs were more sensitive than the 4CV for detecting ductal-dependent forms of CHD. Diagnosis after discharge to home occurred in 39 of 135 postnatal diagnoses (29%), including many cases of isolated outflow tract abnormalities requiring early invasive intervention. CONCLUSIONS: Cases of major neonatal CHD with OFTV abnormalities predominate over cases with 4CV abnormalities, particularly among those forms of CHD requiring early invasive intervention.


Assuntos
Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Distribuição de Qui-Quadrado , Feminino , Coração Fetal/anormalidades , Coração Fetal/anatomia & histologia , Humanos , Lactente , Recém-Nascido , Triagem Neonatal , Gravidez , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA