1.
Med Phys ; 46(5): 2025-2030, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30748029

RESUMO

PURPOSE: High dose rate brachytherapy applies intense and destructive radiation. A treatment plan defines radiation source dwell positions to avoid irradiating healthy tissue. The study discusses methods to quantify any positional changes of source locations along the various treatment sessions. METHODS: Electromagnetic tracking (EMT) localizes the radiation source during the treatment sessions. But in each session the relative position of the patient relative to the filed generator is changed. Hence, the measured dwell point sets need to be registered onto each other to render them comparable. Two point set registration techniques are compared: a probabilistic method called coherent point drift (CPD) and a multidimensional scaling (MDS) technique. RESULTS: Both enable using EMT without external registration and achieve very similar results with respect to dwell position determination of the radiation source. Still MDS achieves smaller grand average deviations (CPD-rPSR: MD = 2.55 mm, MDS-PSR: MD = 2.15 mm) between subsequent dwell position determinations, which also show less variance (CPD-rPSR: IQR = 4 mm, MDS-PSR: IQR = 3 mm). Furthermore, MDS is not based on approximations and does not need an iterative procedure to track sensor positions inside the implanted catheters. CONCLUSION: Although both methods achieve similar results, MDS is to be preferred over rigid CPD while nonrigid CPD is unsuitable as it does not preserve topology.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Processamento de Imagem Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Braquiterapia/instrumentação , Neoplasias da Mama/patologia , Fenômenos Eletromagnéticos , Desenho de Equipamento , Feminino , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
2.
PLoS One ; 12(9): e0183608, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28934238

RESUMO

During High Dose Rate Brachytherapy (HDR-BT) the spatial position of the radiation source inside catheters implanted into a female breast is determined via electromagnetic tracking (EMT). Dwell positions and dwell times of the radiation source are established, relative to the patient's anatomy, from an initial X-ray-CT-image. During the irradiation treatment, catheter displacements can occur due to patient movements. The current study develops an automatic analysis tool of EMT data sets recorded with a solenoid sensor to assure concordance of the source movement with the treatment plan. The tool combines machine learning techniques such as multi-dimensional scaling (MDS), ensemble empirical mode decomposition (EEMD), singular spectrum analysis (SSA) and particle filter (PF) to precisely detect and quantify any mismatch between the treatment plan and actual EMT measurements. We demonstrate that movement artifacts as well as technical signal distortions can be removed automatically and reliably, resulting in artifact-free reconstructed signals. This is a prerequisite for a highly accurate determination of any deviations of dwell positions from the treatment plan.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Mama/radioterapia , Catéteres , Fenômenos Eletromagnéticos , Doses de Radiação , Idoso , Automação , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
3.
Phys Med Biol ; 62(19): 7617-7640, 2017 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-28796645

RESUMO

Modern radiotherapy of female breast cancers often employs high dose rate brachytherapy, where a radioactive source is moved inside catheters, implanted in the female breast, according to a prescribed treatment plan. Source localization relative to the patient's anatomy is determined with solenoid sensors whose spatial positions are measured with an electromagnetic tracking system. Precise sensor dwell position determination is of utmost importance to assure irradiation of the cancerous tissue according to the treatment plan. We present a hybrid data analysis system which combines multi-dimensional scaling with particle filters to precisely determine sensor dwell positions in the catheters during subsequent radiation treatment sessions. Both techniques are complemented with empirical mode decomposition for the removal of superimposed breathing artifacts. We show that the hybrid model robustly and reliably determines the spatial positions of all catheters used during the treatment and precisely determines any deviations of actual sensor dwell positions from the treatment plan. The hybrid system only relies on sensor positions measured with an EMT system and relates them to the spatial positions of the implanted catheters as initially determined with a computed x-ray tomography.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Mama/radioterapia , Fenômenos Eletromagnéticos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Artefatos , Neoplasias da Mama/diagnóstico por imagem , Catéteres , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
4.
Phys Med Biol ; 62(20): 7959-7980, 2017 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-28854159

RESUMO

High dose rate brachytherapy affords a frequent reassurance of the precise dwell positions of the radiation source. The current investigation proposes a multi-dimensional scaling transformation of both data sets to estimate dwell positions without any external reference. Furthermore, the related distributions of dwell positions are characterized by uni-or bi-modal heavy-tailed distributions. The latter are well represented by α-stable distributions. The newly proposed data analysis provides dwell position deviations with high accuracy, and, furthermore, offers a convenient visualization of the actual shapes of the catheters which guide the radiation source during the treatment.


Assuntos
Braquiterapia/instrumentação , Catéteres , Fenômenos Eletromagnéticos , Neoplasias/radioterapia , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Braquiterapia/métodos , Humanos , Neoplasias/diagnóstico por imagem , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA