Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Eur Heart J Cardiovasc Imaging ; 16(12): 1366-73, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25911117

RESUMO

AIMS: To evaluate the feasibility of ultra-low-dose CT for left atrium and pulmonary veins using new model-based iterative reconstruction (MBIR) algorithm. METHODS AND RESULTS: Two hundred patients scheduled for catheter ablation were randomized into two groups: Group 1 (100 patients, Multidetector row CT (MDCT) with MBIR, no ECG triggering, tube voltage and tube current of 100 kV and 60 mA, respectively) and Group 2 [100 patients, MDCT with adaptive statistical iterative reconstruction algorithm (ASIR), no ECG triggering, and kV and mA tailored on patient BMI]. Image quality, CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) of left atrium (LA) and pulmonary veins, and effective dose (ED) were evaluated for each exam and compared between two groups.No significant differences between groups in terms of population characteristics, cardiovascular risk factors, anatomical features, prevalence of persistent atrial fibrillation and image quality score. Statistically significant differences were found between Group 1 and Group 2 in mean attenuation, SNR, and CNR of LA. Significantly, lower values of noise were found in Group 1 versus Group 2. Group 1 showed a significantly lower mean ED in comparison with Group 2 (0.41 ± 0.04 versus 4.17 ± 2.7 mSv). CONCLUSION: The CT for LA and pulmonary veins imaging using MBIR is feasible and allows examinations with very low-radiation exposure without loss of image quality.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Fibrilação Atrial/cirurgia , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído , Software
3.
Clin Radiol ; 67(3): 207-15, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22154609

RESUMO

AIM: To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2). MATERIALS AND METHODS: One hundred and seventy patients scheduled for invasive coronary angiography (ICA) were evaluated. Fourteen patients were not eligible for MDCT. The remaining 156 patients were randomized to group 1 (78 patients) and group 2 (78 patients). Eight and 11 patients in groups 1 and 2, respectively, were excluded after randomization because the patients' heart rates were >65 beats/min. MDCT images were assessed for feasibility, signal-to-noise ration (SNR), and contrast-to-noise ratio (CNR), accuracy in detection of coronary stenoses >50% versus ICA and for ED. RESULTS: The feasibility, SNR, CNR, accuracy in a segment-based and patient-based model were similar in both groups (97 versus 95%, 14.5 ± 3.9 versus 14.2 ± 4.1, 16 ± 4.6 versus 16.5 ± 4.4, 95 versus 94% and 97 versus 99%, respectively). The ED in group 1 was 72% lower than in group 2 (2.1 ± 1.2 versus 7.5 ± 1.8 mSv, respectively; p<0.01). CONCLUSIONS: The use of a multi-parametric ED saving protocol results in a significant reduction in ED without a negative impact on accuracy.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Tomografia Computadorizada Multidetectores/métodos , Idoso , Algoritmos , Índice de Massa Corporal , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA