Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 48(6): 1795-1805, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33341915

RESUMO

PURPOSE: Risk classification of primary prostate cancer in clinical routine is mainly based on prostate-specific antigen (PSA) levels, Gleason scores from biopsy samples, and tumor-nodes-metastasis (TNM) staging. This study aimed to investigate the diagnostic performance of positron emission tomography/magnetic resonance imaging (PET/MRI) in vivo models for predicting low-vs-high lesion risk (LH) as well as biochemical recurrence (BCR) and overall patient risk (OPR) with machine learning. METHODS: Fifty-two patients who underwent multi-parametric dual-tracer [18F]FMC and [68Ga]Ga-PSMA-11 PET/MRI as well as radical prostatectomy between 2014 and 2015 were included as part of a single-center pilot to a randomized prospective trial (NCT02659527). Radiomics in combination with ensemble machine learning was applied including the [68Ga]Ga-PSMA-11 PET, the apparent diffusion coefficient, and the transverse relaxation time-weighted MRI scans of each patient to establish a low-vs-high risk lesion prediction model (MLH). Furthermore, MBCR and MOPR predictive model schemes were built by combining MLH, PSA, and clinical stage values of patients. Performance evaluation of the established models was performed with 1000-fold Monte Carlo (MC) cross-validation. Results were additionally compared to conventional [68Ga]Ga-PSMA-11 standardized uptake value (SUV) analyses. RESULTS: The area under the receiver operator characteristic curve (AUC) of the MLH model (0.86) was higher than the AUC of the [68Ga]Ga-PSMA-11 SUVmax analysis (0.80). MC cross-validation revealed 89% and 91% accuracies with 0.90 and 0.94 AUCs for the MBCR and MOPR models respectively, while standard routine analysis based on PSA, biopsy Gleason score, and TNM staging resulted in 69% and 70% accuracies to predict BCR and OPR respectively. CONCLUSION: Our results demonstrate the potential to enhance risk classification in primary prostate cancer patients built on PET/MRI radiomics and machine learning without biopsy sampling.


Assuntos
Radioisótopos de Gálio , Neoplasias da Próstata , Ácido Edético , Humanos , Imageamento por Ressonância Magnética , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Aprendizado de Máquina Supervisionado
2.
Cancer Imaging ; 18(1): 15, 2018 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-29695290

RESUMO

BACKGROUND: Hybrid PET/CT and PET/MRI are increasingly important technologies in the evaluation of malignancy and require cooperation between radiologists and specialists in molecular imaging. The aim of our study was to probe the mindsets of radiological and nuclear medicine professionals in regard to current hybrid imaging practice and to assess relevant training aspirations and perceived shortfalls, particularly amongst young professionals. In this context, we initiated an international survey on "Hybrid Imaging Training". METHODS: An online survey was prepared on-line and launched on October-2, 2016. It was composed of 17 multiple-choice and open questions regarding the professional background, a perspective on hybrid imaging training efforts and lessons to be learned from disparate craft groups. The survey ran for 2 weeks. We report total responses per category and individual free-text responses. RESULTS: In total, 248 responses were collected with a mean age of all responders of (41 ± 11) y. Overall, 36% were within the target age range of (20-35) y. Across all responders, the majority (72%) commented on there being too few hybrid imaging experts in their country, whereas only 1% said that there were too many. Three quarters of the responders were in favour of a curriculum allowing sub-specialisation in hybrid imaging. With respect to reporting of hybrid imaging, confidence increased with age. The average rating across all responders on the level of cooperation among the two specialties suggested a low overall level of satisfaction. However, the survey feedback indicated the local (on-site) cooperation being somewhat better than the perceived cooperation between the relevant associations on a European level. CONCLUSION: We consider these results to represent an appropriate cross-section of professional opinions of imaging experts across different demographic and hierarchical levels. Collectively they provide evidence supporting a need to address current shortfalls in developing hybrid imaging expertise through national educational plans, and, thus, contribute to helping improve patient care.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radiologistas/educação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
3.
Mol Imaging Biol ; 18(5): 637-50, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27534971

RESUMO

This article provides a collaborative perspective of the discussions and conclusions from the fifth international workshop of combined positron emission tomorgraphy (PET)/magnetic resonance imaging (MRI) that was held in Tübingen, Germany, from February 15 to 19, 2016. Specifically, we summarise the second part of the workshop made up of invited presentations from active researchers in the field of PET/MRI and associated fields augmented by round table discussions and dialogue boards with specific topics. This year, this included practical advice as to possible approaches to moving PET/MRI into clinical routine, the use of PET/MRI in brain receptor imaging, in assessing cardiovascular diseases, cancer, infection, and inflammatory diseases. To address perceived challenges still remaining to innovatively integrate PET and MRI system technologies, a dedicated round table session brought together key representatives from industry and academia who were engaged with either the conceptualisation or early adoption of hybrid PET/MRI systems. Discussions during the workshop highlighted that emerging unique applications of PET/MRI such as the ability to provide multi-parametric quantitative and visual information which will enable not only overall disease detection but also disease characterisation would eventually be regarded as compelling arguments for the adoption of PET/MR. However, as indicated by previous workshops, evidence in favour of this observation is only growing slowly, mainly due to the ongoing inability to pool data cohorts from independent trials as well as different systems and sites. The participants emphasised that moving from status quo to status go entails the need to adopt standardised imaging procedures and the readiness to act together prospectively across multiple PET/MRI sites and vendors.


Assuntos
Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Animais , Doença , Alemanha , Humanos
4.
EJNMMI Res ; 6(Suppl 1): 32, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27090254

RESUMO

TABLE OF CONTENTS: A1 68Ga-PSMA PET/CT in staging and restaging of Prostate Cancer Patients: comparative study with 18F-Choline PET/CTW Langsteger, A Rezaee, W Loidl, HS Geinitz, F Fitz, M Steinmair, G Broinger, L Pallwien-Prettner, M BeheshtiA2 F18 Choline PET - CT: an accurate diagnostic tool for the detection of parathyroid adenoma?L Imamovic, M Beheshti, G Rendl, D Hackl, O Tsybrovsky, M Steinmair, K Emmanuel, F Moinfar, C Pirich, W LangstegerA3 [18F]Fluoro-DOPA-PET/CT in the primary diagnosis of medullary thyroid carcinomaA Bytyqi, G Karanikas, M Mayerhöfer, O Koperek, B Niederle, M HartenbachA4 Variations of clinical PET/MR operations: An international survey on the clinical utilization of PET/MRIT Beyer, K Herrmann, J CzerninA5 Standard Dixon-based attenuation correction in combined PET/MRI: Reproducibility and the possibility of Lean body mass estimationI Rausch, P Rust, MD DiFranco, M Lassen, A Stadlbauer, ME Mayerhöfer, M Hartenbach, M Hacker, T BeyerA6 High resolution digital FDG PET/MRI imaging for assessment of ACL graft viabilityK Binzel, R Magnussen, W Wei, MU Knopp, DC Flanigan, C Kaeding, MV KnoppA7 Using pre-existing hematotoxicity as predictor for severe side effects and number of treatment cycles of Xofigo therapyA Leisser, M Nejabat, M Hartenbach, G Kramer, M Krainer, M Hacker, A HaugA8 QDOSE - comprehensive software solution for internal dose assessmentWencke Lehnert, Karl Schmidt, Sharok Kimiaei, Marcus Bronzel, Andreas KlugeA9 Clinical impact of Time-of-Flight on next-generation digital PET imaging of Yttrium-90 radioactivity following liver radioembolizationCL Wright, K Binzel, J Zhang, Evan Wuthrick, Piotr Maniawski, MV KnoppA10 Snakes in patients! Lessons learned from programming active contours for automated organ segmentationM Blaickner, E Rados, A Huber, M Dulovits, H Kulkarni, S Wiessalla, C Schuchardt, RP Baum, B Knäusl, D GeorgA11 Influence of a genetic polymorphism on brain uptake of the dual ABCB1/ABCG2 substrate [11C]tariquidarM Bauer, B Wulkersdorfer, W Wadsak, C Philippe, H Haslacher, M Zeitlinger, O LangerA12 Outcome prediction of temporal lobe epilepsy surgery from P-glycoprotein activity. Pooled analysis of (R)-[11C]-verapamil PET data from two European centresM Bauer, M Feldmann, R Karch, W Wadsak, M Zeitlinger, MJ Koepp, M-C Asselin, E Pataraia, O LangerA13 In-vitro and in-vivo characterization of [18F]FE@SNAP and derivatives for the visualization of the melanin concentrating hormone receptor 1M Zeilinger, C Philippe, M Dumanic, F Pichler, J Pilz, M Hacker, W Wadsak, M MitterhauserA14 Reducing time in quality control leads to higher specific radioactivity of short-lived radiotracersL Nics, B Steiner, M Hacker, M Mitterhauser, W WadsakA15 In vitro 11C-erlotinib binding experiments in cancer cell lines with epidermal growth factor receptor mutationsA Traxl, Thomas Wanek, Kushtrim Kryeziu, Severin Mairinger, Johann Stanek, Walter Berger, Claudia Kuntner, Oliver LangerA16 7-[11C]methyl-6-bromopurine, a PET tracer to measure brain Mrp1 function: radiosynthesis and first PET evaluation in miceS Mairinger, T Wanek, A Traxl, M Krohn, J Stanek, T Filip, M Sauberer, C Kuntner, J Pahnke, O LangerA17 18F labeled azidoglucose derivatives as "click" agents for pretargeted PET imagingD Svatunek, C Denk, M Wilkovitsch, T Wanek, T Filip, C Kuntner-Hannes, J Fröhlich, H MikulaA18 Bioorthogonal tools for PET imaging: development of radiolabeled 1,2,4,5-TetrazinesC Denk, D Svatunek, T Wanek, S Mairinger, J Stanek, T Filip, J Fröhlich, H Mikula, C Kuntner-HannesA19 Preclinical evaluation of [18F]FE@SUPPY- a new PET-tracer for oncologyT Balber, J Singer, J Fazekas, C Rami-Mark, N Berroterán-Infante, E Jensen-Jarolim, W Wadsak, M Hacker, H Viernstein, M MitterhauserA20 Investigation of Small [18F]-Fluoroalkylazides for Rapid Radiolabeling and In Vivo Click ChemistryC Denk, D Svatunek, B Sohr, H Mikula, J Fröhlich, T Wanek, C Kuntner-Hannes, T FilipA21 Microfluidic 68Ga-radiolabeling of PSMA-HBED-CC using a flow-through reactorS Pfaff, C Philippe, M Mitterhauser, M Hartenbach, M Hacker, W WadsakA22 Influence of 24-nor-ursodeoxycholic acid on hepatic disposition of [18F]ciprofloxacin measured with positron emission tomographyT Wanek, E Halilbasic, M Visentin, S Mairinger, B Stieger, C Kuntner, M Trauner, O LangerA23 Automated 18F-flumazenil production using chemically resistant disposable cassettesP Lam, M Aistleitner, R Eichinger, C ArtnerA24 Similarities and differences in the synthesis and quality control of 177Lu-DOTA-TATE, 177Lu -HA-DOTA-TATE and 177Lu-DOTA-PSMA (PSMA-617)H Eidherr, C Vraka, A Haug, M Mitterhauser, L Nics, M Hartenbach, M Hacker, W WadsakA25 68Ga- and 177Lu-labelling of PSMA-617H Kvaternik, R Müller, D Hausberger, C Zink, RM AignerA26 Radiolabelling of liposomes with 67Ga and biodistribution studies after administration by an aerosol inhalation systemU Cossío, M Asensio, A Montes, S Akhtar, Y te Welscher, R van Nostrum, V Gómez-Vallejo, J LlopA27 Fully automated quantification of DaTscan SPECT: Integration of age and gender differencesF VandeVyver, T Barclay, N Lippens, M TrochA28 Lesion-to-background ratio in co-registered 18F-FET PET/MR imaging - is it a valuable tool to differentiate between low grade and high grade brain tumor?L Hehenwarter, B Egger, J Holzmannhofer, M Rodrigues-Radischat, C PirichA29 [11C]-methionine PET in gliomas - a retrospective data analysis of 166 patientsN Pötsch, I Rausch, D Wilhelm, M Weber, J Furtner, G Karanikas, A Wöhrer, M Mitterhauser, M Hacker, T Traub-WeidingerA30 18F-Fluorocholine versus 18F-Fluorodeoxyglucose for PET/CT imaging in patients with relapsed or progressive multiple myeloma: a pilot studyT Cassou-Mounat, S Balogova, V Nataf, M Calzada, V Huchet, K Kerrou, J-Y Devaux, M Mohty, L Garderet, J-N TalbotA31 Prognostic benefit of additional SPECT/CT in sentinel lymph node mapping of breast cancer patientsS Stanzel, G Pregartner, T Schwarz, V Bjelic-Radisic, B Liegl-Atzwanger, R AignerA32 Evaluation of diagnostic value of TOF-18F-FDG PET/CT in patients with suspected pancreatic cancerS Stanzel, F Quehenberger, RM AignerA33 New quantification method for diagnosis of primary hyperpatahyroidism lesions and differential diagnosis vs thyropid nodular disease in dynamic scintigraphyA Koljevic Markovic, Milica Jankovic, V Miler Jerkovic, M Paskas, G Pupic, R Dzodic, D PopovicA34 A rare case of diffuse pancreatic involvement in patient with merkel cell carcinoma detected by 18F-FDGMC Fornito, D FamiliariA35 TSH-stimulated 18F-FDG PET/CT in the diagnosis of recurrent/metastatic radioiodine-negative differentiated thyroid carcinomas in patients with various thyroglobuline levelsP Koranda, H Polzerová, I Metelková, L Henzlová, R Formánek, E Buriánková, M KamínekA36 Breast Dose from lactation following I131 treatmentWH Thomson, C LewisA37 A new concept for performing SeHCAT studies with the gamma cameraWH Thomson, J O'Brien, G James, A NotghiA38 Whole body F-18-FDG-PET and tuberculosis: sensitivity compared to x-ray-CTH Huber, I Stelzmüller, R Wunn, M Mandl, F Fellner, B Lamprecht, M GabrielA39 Emerging role 18F-FDG PET-CT in the diagnosis and follow-up of the infection in heartware ventricular assist system (HVAD)MC Fornito, G LeonardiA40 Validation of Poisson resampling softwareWH Thomson, J O'Brien, G JamesA41 Protection of PET nuclear medicine personnel: problems in satisfying dose limit requirementsJ Hudzietzová, J Sabol, M Fülöp.

5.
Mol Imaging Biol ; 17(5): 595-608, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26286794

RESUMO

This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from February 23 to 27, 2015. Specifically, we summarise the three days of invited presentations from active researchers in this and associated fields augmented by round table discussions and dialogue boards with specific topics. These include the use of PET/MRI in cardiovascular disease, paediatrics, oncology, neurology and multi-parametric imaging, the latter of which was suggested as a key promoting factor for the wider adoption of integrated PET/MRI. Discussions throughout the workshop and a poll taken on the final day demonstrated that attendees felt more strongly that PET/MRI has further advanced in both technical versatility and acceptance by clinical and research-driven users from the status quo of last year. Still, with only minimal evidence of progress made in exploiting the true complementary nature of the PET and MRI-based information, PET/MRI is still yet to achieve its potential. In that regard, the conclusion of last year's meeting "the real work has just started" still holds true.


Assuntos
Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Alemanha , Humanos
6.
Mol Imaging Biol ; 17(3): 297-312, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25672749

RESUMO

This paper summarises the proceedings and discussions at the third annual workshop held in Tübingen, Germany, dedicated to the advancement of the technical, scientific and clinical applications of combined PET/MRI systems in humans. Two days of basic scientific and technical instructions with "hands-on" tutorials were followed by 3 days of invited presentations from active researchers in this and associated fields augmented by round-table discussions and dialogue boards with specific themes. These included the use of PET/MRI in paediatric oncology and in adult neurology, oncology and cardiology, the development of multi-parametric analyses, and efforts to standardise PET/MRI examinations to allow pooling of data for evaluating the technology. A poll taken on the final day demonstrated that over 50 % of those present felt that while PET/MRI technology underwent an inevitable slump after its much-anticipated initial launch, it was now entering a period of slow, progressive development, with new key applications emerging. In particular, researchers are focusing on exploiting the complementary nature of the physiological (PET) and biochemical (MRI/MRS) data within the morphological framework (MRI) that these devices can provide. Much of the discussion was summed up on the final day when one speaker commented on the state of PET/MRI: "the real work has just started".


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Animais , Cardiologia/métodos , Alemanha , Humanos , Processamento de Imagem Assistida por Computador/métodos , Oncologia/métodos , Neurologia/métodos
7.
Nuklearmedizin ; 53(6): 242-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25131649

RESUMO

AIM: To gather information on clinical operations, quality control (QC) standards and adoption of guidelines for FDG-PET/CT imaging in Austrian PET/CT centres. METHODS: A written survey composed of 68 questions related to A) PET/CT centre and installation, B) standard protocol parameters for FDG-PET/CT imaging of oncology patients, and C) standard QC procedures was conducted between November and December 2013 among all Austrian PET/CT centres. In addition, a NEMA-NU2 2012 image quality phantom test was performed using standard whole-body imaging settings on all PET/CT systems with a lesion-to-background ratio of 4. Recovery coefficients (RC) were calculated for each lesion and PET/CT system. RESULTS: A) 13 PET/CT systems were installed in 12 nuclear medicine departments at public hospitals. B) Average fasting prior to FDG-PET/CT was 7.6 (4-12) h. All sites measured blood glucose levels while using different cut-off levels (64%: 150 mg/dl). Weight-based activity injection was performed at 83% sites with a mean FDG activity of 4.1 MBq/kg. Average FDG uptake time was 55 (45-75) min. All sites employed CT contrast agents (variation from 1%-95% of the patients). All sites reported SUV-max. C) Frequency of QC tests varied significantly and QC phantom measurements revealed significant differences in RCs. CONCLUSION: Significant variations in FDG-PET/CT protocol parameters among all Austrian PET/CT users were observed. Subsequently, efforts need to be put in place to further standardize imaging protocols. At a minimum clinical PET/CT operations should ensure compliance with existing guidelines. Further, standardized QC procedures must be followed to improve quantitative accuracy across PET/CT centres.


Assuntos
Fluordesoxiglucose F18 , Fidelidade a Diretrizes/estatística & dados numéricos , Imagem Multimodal/normas , Medicina Nuclear/normas , Tomografia por Emissão de Pósitrons/normas , Tomografia Computadorizada por Raios X/normas , Áustria , Pesquisas sobre Atenção à Saúde , Internacionalidade , Imagem Multimodal/estatística & dados numéricos , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/estatística & dados numéricos
8.
Eur J Radiol ; 83(7): 1177-1183, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24780817

RESUMO

PURPOSE: In combined PET/MRI standard PET attenuation correction (AC) is based on tissue segmentation following dedicated MR sequencing and, typically, bone tissue is not represented. We evaluate PET quantification in whole-body (WB)-PET/MRI following MR-AC without considering bone attenuation and then investigate different strategies to account for bone tissue in clinical PET/MR imaging. To this purpose, bone tissue representation was extracted from separate CT images, and different bone representations were simulated from hypothetically derived MR-based bone classifications. METHODS: Twenty oncology patients referred for a PET/CT were injected with either [18F]-FDG or [18F]-NaF and imaged on PET/CT (Biograph TruePoint/mCT, Siemens) and PET/MRI (mMR, Siemens) following a standard single-injection, dual-imaging clinical WB-protocol. Routine MR-AC was based on in-/opposed-phase MR imaging (orgMR-AC). PET(/MRI) images were reconstructed (AW-OSEM, 3 iterations, 21 subsets, 4mm Gaussian) following routine MR-AC and MR-AC based on four modified attenuation maps. These modified attenuation maps were created for each patient by non-linear co-registration of the CT images to the orgMR-AC images, and adding CT bone mask values representing cortical bone: 1200HU (cortCT), spongiosa bone: 350HU (spongCT), average CT value (meanCT) and original CT values (orgCT). Relative difference images of the PET following AC using the modified attenuation maps were compared. SUVmean was calculated in anatomical reference regions and for PET-positive lesions. RESULTS: The relative differences in SUVmean across patients following orgMR-AC and orgCT in soft tissue lesions and in bone lesions were similar (range: 0.0% to -22.5%), with an average underestimation of SUVmean of 7.2% and 10.0%, respectively when using orgMR-AC. In bone lesions, spongCT values were closest to orgCT (median bias of 1.3%, range: -9.0% to 13.5%) while the overestimation of SUVmean with respect to orgCT was highest for cortCT (40.8%, range: 1.5% to 110.8%). For soft tissue lesions the bias was highest using cortCT (13.4%, range: -2.3% to 17.3%) and lowest for spongCT (-2.2%, range: 0.0% to -13.7%). CONCLUSIONS: In PET/MR imaging using standard MR-AC PET uptake values in soft lesions and bone lesions are underestimated by about 10%. In individual patients this bias can be as high as 22%, which is significant during clinical follow-up exams. If bone segmentation is available, then assigning a fixed attenuation value of spongious bone to all bone structures appears reasonable and results in only a minor bias of 5%, or less in uptake values of soft tissue and bone lesions.


Assuntos
Artefatos , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Nuklearmedizin ; 51(4): 140-53, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22473130

RESUMO

UNLABELLED: This work addresses the clinical adoption of FDG-PET/CT for image-guided radiation therapy planning (RTP). As such, important technical and methodological aspects of PET/CT-based RTP are reviewed and practical recommendations are given for routine patient management and clinical studies. First, recent developments in PET/CT hardware that are relevant to RTP are reviewed in the context of quality control and system calibration procedures that are mandatory for a reproducible adoption of PET/CT in RTP. Second, recommendations are provided on image acquisition and reconstruction to support the standardization of imaging protocols. A major prerequisite for routine RTP is a complete and secure data transfer to the actual planning system. Third, state-of-the-art tools for image fusion and co-registration are discussed briefly in the context of PET/CT imaging pre- and post-RTP. This includes a brief review of state-of-the-art image contouring algorithms relevant to PET/CT-guided RTP. Finally, practical aspects of clinical workflow and patient management, such as patient setup and requirements for staff training are emphasized. PET/CT-guided RTP mandates attention to logistical aspects, patient set-up and acquisition parameters as well as an in-depth appreciation of quality control and protocol standardization. CONCLUSION: Upon fulfilling the requirements to perform PET/CT for RTP, a new dimension of molecular imaging can be added to traditional morphological imaging. As a consequence, PET/CT imaging will support improved RTP and better patient care. This document serves as a guidance on practical and clinically validated instructions that are deemed useful to the staff involved in PET/CT-guided RTP.


Assuntos
Algoritmos , Fluordesoxiglucose F18 , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X , Humanos , Compostos Radiofarmacêuticos , Dosagem Radioterapêutica , Integração de Sistemas
10.
Eur Respir J ; 39(3): 685-90, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21852332

RESUMO

Forceps, brushes or needles are currently the standard tools used during flexible bronchoscopy when diagnosing endobronchial malignancies. The new biopsy technique of cryobiopsy appears to provide better diagnostic samples. The aim of this study was to evaluate cryobiopsy over conventional endobronchial sampling. A total of 600 patients in eight centres with suspected endobronchial tumours were included in a prospective, randomised, single-blinded multicentre study. Patients were randomised to either sampling using forceps or the cryoprobe. After obtaining biopsy samples, a blinded histological evaluation was performed. According to the definitive clinical diagnosis, the diagnostic yield for malignancy was evaluated by a Chi-squared test. A total of 593 patients were randomised, of whom 563 had a final diagnosis of cancer. 281 patients were randomised to receive endobronchial biopsies using forceps and 282 had biopsies performed using a flexible cryoprobe. A definitive diagnosis was achieved in 85.1% of patients randomised to conventional forceps biopsy and 95.0% of patients who underwent cryobiopsy (p<0.001). Importantly, there was no difference in the incidence of significant bleeding. Endobronchial cryobiopsy is a safe technique with superior diagnostic yield in comparison with conventional forceps biopsy.


Assuntos
Biópsia/métodos , Broncoscopia/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Neoplasias Pulmonares/diagnóstico , Carcinoma de Pequenas Células do Pulmão/diagnóstico , Idoso , Biópsia/efeitos adversos , Biópsia/instrumentação , Broncoscopia/efeitos adversos , Broncoscopia/instrumentação , Feminino , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Método Simples-Cego , Instrumentos Cirúrgicos/efeitos adversos
11.
J Immunol Methods ; 346(1-2): 26-37, 2009 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-19427867

RESUMO

Natural IgA antibodies are abundantly produced in vivo to protect serosal surfaces from invading infectious organisms. However, the immunotherapeutic potential of IgA has hardly been explored, although there is evidence that recombinant IgA antibodies may broaden the armentarium to combat certain infectious or malignant diseases. One of the limitations for exploring IgA's therapeutic activity has been the difficulty to obtain enough recombinant material with desired specificity for in vivo studies. Here, we describe the production and purification of monomeric recombinant IgA1 and IgA2 antibodies under serum-free conditions. For antibody production, suspension adapted CHO-K1 cells and a glutamine synthetase selection vector were used, which resulted in specific production rates of up to 2.2 pg/cell/day. Purities of >95% of monomeric antibodies were obtained by a combination of affinity chromatography-using an anti-kappa-light chain matrix-and size exclusion chromatography. Purified antibodies displayed the expected biochemical characteristics and were functionally fully active. Importantly, all required reagents and methods are commercially available and not dependent on the specificity of the desired antibody. In addition, all employed technologies and methodologies are similar to those used for the production of therapeutic IgG antibodies - thus allowing further up-scaling and streamlining according to existing antibody production technologies. In conclusion, the described methodology may assist in the development of recombinant IgA antibodies for therapeutic applications.


Assuntos
Imunoglobulina A/biossíntese , Imunoglobulina A/isolamento & purificação , Cadeias Pesadas de Imunoglobulinas/biossíntese , Cadeias Pesadas de Imunoglobulinas/isolamento & purificação , Cadeias Leves de Imunoglobulina/biossíntese , Cadeias Leves de Imunoglobulina/isolamento & purificação , Animais , Especificidade de Anticorpos , Citotoxicidade Celular Dependente de Anticorpos , Sítios de Ligação de Anticorpos , Células CHO , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Cromatografia de Afinidade , Cromatografia em Gel , Cricetinae , Cricetulus , Receptores ErbB/antagonistas & inibidores , Receptores ErbB/imunologia , Humanos , Hibridomas , Imunoglobulina A/genética , Imunoglobulina A/metabolismo , Imunoglobulina A/farmacologia , Cadeias Pesadas de Imunoglobulinas/genética , Cadeias Pesadas de Imunoglobulinas/metabolismo , Cadeias Pesadas de Imunoglobulinas/farmacologia , Cadeias Leves de Imunoglobulina/genética , Cadeias Leves de Imunoglobulina/metabolismo , Cadeias Leves de Imunoglobulina/farmacologia , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/imunologia , Proteínas Recombinantes de Fusão/biossíntese , Proteínas Recombinantes de Fusão/isolamento & purificação , Transfecção
12.
Nuklearmedizin ; 47(2): 73-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18392316

RESUMO

UNLABELLED: We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. PATIENTS, METHODS: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDG-PET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image frames that resulted in confidence grades 2 and 3. Whole-body FDG-PET/CT images were reviewed for lesions. PET-MRI and PET/CT-MRI images of the head were co-registered for potentially improved lesion delineation. RESULTS: Whole-body FDG-PET/CT images of 3/3 patients were positive for uveal melanomas and negative for disseminated disease. HR FDG-PET was positive already in the early time frames. One patient exhibited rising tumour activity with increasing uptake time on FDG-PET. MRI images of the eye were co-registered successfully to FDG-PET/CT using a manual alignment approach. CONCLUSIONS: Small-size uveal melanomas can be detected with whole-body FDG-PET/CT. This feasibility study suggests the exploration of HR FDG-PET in order to provide additional diagnostic information on patients with uveal melanomas. First results support extended uptake times and high-sensitivity PET for improved tumour visibility. MRI/PET co-registration is feasible and provides correlated functional and anatomical information that may support alternative therapy regimens.


Assuntos
Neoplasias Uveais/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética/métodos , Melanoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Radiografia , Radioisótopos , Sensibilidade e Especificidade , Neoplasias Uveais/diagnóstico , Irradiação Corporal Total
14.
Nuklearmedizin ; 46(6): 291-301, 2007.
Artigo em Alemão | MEDLINE | ID: mdl-18084685

RESUMO

FDG-PET/CT examinations combine metabolic and morphologic imaging within an integrated procedure. Over the past decade PET/CT imaging has gained wide clinical acceptance in the field of oncology. This FDG-PET/CT guideline focuses on indications, data acquisition and processing as well as documentation of FDG-PET/CT examinations in oncologic patients within a clinical and social context specific to Germany. Background information and definitions are followed by examples of clinical and research applications of FDG-PET/CT. Furthermore, protocols for CT scanning (low dose and contrast-enhanced CT) and PET emission imaging are discussed. Documentation and reporting of examinations are specified. Image interpretation criteria and sources of errors are discussed. Quality control for FDG and PET/CT-systems, qualification requirements of personnel as well as legal aspects are presented.


Assuntos
Fluordesoxiglucose F18 , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/normas , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/normas , Documentação , Humanos
15.
Br J Radiol ; 80(955): 508-15, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17537758

RESUMO

We aimed to compare the value of combined positron emission tomography (PET)/CT, PET+CT (viewed side by side), CT alone and PET alone concerning the rTNM stage and influence on therapy in patients with recurrent breast cancer. 44 patients with suspicion of recurrent breast cancer underwent whole-body [18F]-2-fluoro-2-deoxy-d-glucose (FDG)-PET/CT. Images of combined PET/CT, PET+CT, PET alone and CT alone were evaluated by four blinded reader teams. Diagnostic accuracies and influence on therapy were compared. Histology and a mean clinical follow up of 456 days served as the standard of reference. Differences between the staging procedures were tested for statistical significance by McNemar's test. Overall TNM tumour stage was correctly determined in 40/44 patients with PET/CT, in 38/44 with PET+CT, in 36/44 with PET alone and in 36/44 patients with CT alone. No statistically significant difference was detected between all tested imaging modalities. PET/CT changed the therapy in two patients compared with PET+CT, in four patients compared with PET alone and in five patients compared with CT alone. Combined PET/CT appeared to be more accurate in assessing the rTNM and showed a moderate impact on therapy over PET and CT. Minor improvements were noted when compared with PET+CT. Experienced readers might therefore be able to provide accurate staging results for further therapy from separately acquired studies.


Assuntos
Neoplasias da Mama/patologia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/secundário , Feminino , Fluordesoxiglucose F18 , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/secundário
17.
Surgery ; 140(4): 655-63; discussion 653-4, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17011914

RESUMO

BACKGROUND: Subjective symptoms such as decreased energy, chronic fatigue, and depression are associated with hyperparathyroidism. Studies have shown that these symptoms are improved during short-term follow-up after parathyroidectomy. This study evaluates the durability of this subjective improvement in quality-of-life symptoms in a large population of patients with follow-up greater than 1 year after operation. METHODS: Between 2002 and 2005, 258 patients underwent parathyroidectomy, 100 (81 females and 19 males) of whom were available for this study. The patients were evaluated with a survey based on the Health Outcomes Institute Health Status Questionnaire. Some answers were quantified on a 1 to 6 scale, while others consisted of "yes" or "no" responses. Patients completed a questionnaire prior to parathyroidectomy and postoperatively at 1 month, 3 to 6 months, and 1 to 2 years or greater intervals. Statistical analysis was used to detect changes attributable to parathyroidectomy. A P value <.05 was considered statistically significant. RESULTS: At 1-month follow-up, patients' perceptions of their overall health, energy level, and mood significantly improved. At 6-month follow-up, significant improvements in muscle strength, health, endurance, and relief of anxiety were documented. At the interval of 1 to 2 years, overall health, energy level, endurance, and relief of anxiety were improved. There was no significant decrement in the quality of life in these patients after parathyroidectomy. CONCLUSIONS: Parathyroidectomy for hyperparathyroidism is associated with significant lasting improvement in subjective symptoms. The potential durable improvement in these quality-of-life symptoms is a valid indication for parathyroidectomy.


Assuntos
Hiperparatireoidismo/psicologia , Hiperparatireoidismo/cirurgia , Paratireoidectomia/psicologia , Satisfação do Paciente , Qualidade de Vida , Atividades Cotidianas , Adolescente , Adulto , Afeto , Idoso , Idoso de 80 Anos ou mais , Ansiedade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Inquéritos e Questionários
18.
Nuklearmedizin ; 45(5): 219-22, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17043733

RESUMO

UNLABELLED: PET/CT imaging is particularly promising for head/neck malignancies, but dental implants lead to biased CT attenuation and PET activity values following CT-based attenuation correction (CT-AC). OBJECTIVE: Here, we implement a metal artifact correction procedure (MAR) as part of the CT-AC for PET/CT imaging. RESULTS: Phantom studies indicate a maximum quantitative bias in CT and PET of 1000 HU and 30 %, which is reduced to 230 HU and 6 %, respectively following MAR. These results were verified in selected patients. CONCLUSION: Artifacts and biases from dental implants can be reduced in PET/CT imaging by applying a simple MAR as part of the CT-AC.


Assuntos
Implantes Dentários , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Artefatos , Humanos , Mandíbula/diagnóstico por imagem , Maxila/diagnóstico por imagem , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
19.
Nuklearmedizin ; 45(5): 229-34, 2006.
Artigo em Alemão | MEDLINE | ID: mdl-17043735

RESUMO

AIM: We assess the perspective of patients with thyroid disease towards radiation and radioactivity by means of a cultural-anthropological approach based on qualitative measures and quantitative scores. From the interviews with the patients we evaluate as to how much radioactivity is accepted as an abstract term or as a benefit within the medical context. PATIENTS, METHODS: 68 patients with autonomously functioning thyroid lesions (35 women, 33 men, 32-81 years) were included in this study. All patients were interviewed in an open dialogue with the principal investigator. Patients were asked to describe their attitude towards radioactivity in general and towards radioiodine therapy in particular. Patients were asked to use a scoring system (1 = positive, 5 = negative) to quantify their attitudes. RESULTS: The responses of all patients towards radioactivity in general were heterogeneous with most responses reflecting a negative perception. Many patients expressed their associated fears about atomic energy, malignant diseases and radioactive contamination. The scoring system reflected a mostly negative opinion base. However, patients became more positive once they assumed an immediate benefit of radioactivity for the treatment of their own disease (p = 0.01). CONCLUSIONS: Knowing about significant differences in patient's perception about radioactivity in general or in the clinical context may help to optimise and tailor the initial, pre-therapeutical interview towards the patient.


Assuntos
Radioisótopos do Iodo/efeitos adversos , Doenças da Glândula Tireoide/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Entrevistas como Assunto , Radioisótopos do Iodo/uso terapêutico , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
20.
Gut ; 55(1): 68-73, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15970580

RESUMO

AIM: The aim of this study was to implement an imaging protocol for positron emission tomography/computed tomography (PET/CT) colonography and to combine this protocol with whole body PET/CT tumour staging for a single whole body examination for routine clinical use. SUBJECTS AND METHODS: A whole body PET/CT protocol for tumour staging and a protocol for PET/CT colonography were integrated into one examination. Fourteen prospective patients with suspected colorectal cancer underwent whole body PET/CT after aqueous bowel distension and pharmacological bowel relaxation. Colonoscopy and histopathology served as the standards of reference in all patients. RESULTS: The modified PET/CT examination detected all but one lesion in the colon. One additional lesion was detected in a patient with incomplete colonoscopy due to high grade luminal stenosis. One polyp with malignant conversion was identified with the modified PET/CT protocol. PET/CT colonography proved accurate in local lymph node staging and staged nine out of 11 patients correctly. Six additional extracolonic tumour sites were detected based on the whole body staging approach. CONCLUSION: Whole body PET/CT with integrated colonography is technically feasible for whole body staging in patients with colorectal cancer. Based on these initial diagnostic experiences, this integrated protocol may be of substantial benefit in staging patients with colorectal cancer, focusing on patients with incomplete colonoscopy and those with small synchronous bowel lesions.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Idoso , Protocolos Clínicos , Neoplasias Colorretais/patologia , Estudos de Viabilidade , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Imagem Corporal Total/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA