Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Am Coll Radiol ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38729590

RESUMO

OBJECTIVE: Variability in prostate MRI quality is an increasingly recognized problem that negatively affects patient care. This report aims to describe the results and key learnings of the first cohort of the ACR Learning Network Prostate MR Image Quality Improvement Collaborative. METHODS: Teams from five organizations in the U.S. were trained on a structured improvement method. After reaching a consensus on image quality and auditing their images using the Prostate Imaging Quality (PI-QUAL) system, teams conducted a current state analysis to identify barriers to obtaining high-quality images. Through plan-do-study-act cycles involving frontline staff, each site designed and tested interventions targeting image quality key drivers. The percentage of exams meeting quality criteria (i.e., PI-QUAL score ≥ 4) was plotted on a run chart, and project progress was reviewed in weekly meetings. At the collaborative level, the goal was to increase the percentage of exams with PI-QUAL ≥ 4 to at least 85%. RESULTS: Across 2380 exams audited, the mean weekly rates of prostate MR exams meeting image quality criteria increased from 67% (range: 60-74%) at baseline to 87% (range: 80-97%) upon program completion. The most commonly employed interventions were MR protocol adjustments, development and implementation of patient preparation instructions, personell training and development of an auditing process mechanism. CONCLUSION: A Learning Network model, where organizations share knowledge and work together toward a common goal, can improve prostate MR image quality at multiple sites simultaneously. The inaugural cohort's key learnings provide a roadmap for improvement on a broader scale.

2.
Eur J Radiol ; 165: 110937, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37352683

RESUMO

Magnetic resonance imaging (MRI) has become integral to diagnosing and managing patients with suspected or confirmed prostate cancer. However, the benefits of utilizing MRI can be hindered by quality issues during imaging acquisition, interpretation, and reporting. As the utilization of prostate MRI continues to increase in clinical practice, the variability in MRI quality and how it can negatively impact patient care have become apparent. The American College of Radiology (ACR) has recognized this challenge and developed several initiatives to address the issue of inconsistent MRI quality and ensure that imaging centers deliver high-quality patient care. These initiatives include the Prostate Imaging Reporting and Data System (PI-RADS), developed in collaboration with an international panel of experts and members of the European Society of Urogenital Radiology (ESUR), the Prostate MR Image Quality Improvement Collaborative, which is part of the ACR Learning Network, the ACR Prostate Cancer MRI Center Designation, and the ACR Appropriateness Criteria. In this article, we will discuss the importance of these initiatives in establishing quality assurance and quality control programs for prostate MRI and how they can improve patient outcomes.


Assuntos
Neoplasias da Próstata , Radiologia , Masculino , Humanos , Estados Unidos , Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/patologia
3.
J Am Coll Radiol ; 20(3): 369-376, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36922112

RESUMO

PURPOSE: The ACR Learning Network was established to test the viability of the learning network model in radiology. In this report, the authors review the learning network concept, introduce the ACR Learning Network and its components, and report progress to date and plans for the future. METHODS: Patterned after institutional programs developed by the principal investigator, the ACR Learning Network was composed of four distinct improvement collaboratives. Initial participating sites were solicited through broad program advertisement. Candidate programs were selected on the basis of assessments of local leadership support, experience with quality improvement initiatives, intraorganizational relationships, and access to data and analytic support. Participation began with completing a 27-week formal quality improvement training and project support program, with local teams reporting weekly progress on a common performance measure. RESULTS: Four improvement collaborative topics were chosen for the initial cohort with the following numbers of participating sites: mammography positioning (6), prostate MR image quality (6), lung cancer screening (6), and follow-up on recommendations for management of incidental findings (4). To date, all sites have remained actively engaged and have progressed in an expected fashion. A detailed report of the results of the improvement phase will be provided in a future publication. CONCLUSIONS: To date, the ACR Learning Network has successfully achieved planned milestones outlined in the program's plan, with preparation under way for the second and third cohorts. By providing a shared platform for improvement training and knowledge sharing, the authors are optimistic that the network may facilitate widespread performance improvement in radiology on a number of topics for years to come.


Assuntos
Práticas Interdisciplinares , Neoplasias Pulmonares , Humanos , Detecção Precoce de Câncer , Aprendizagem , Mamografia , Melhoria de Qualidade
4.
J Am Coll Radiol ; 19(5): 604-614, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35358482

RESUMO

PURPOSE: Data on utilization rate and cancer yield of BI-RADS® category 3 in routine clinical practice in diagnostic mammography are sparse. The aim of this study was to determine utilization rate and cancer yield of BI-RADS 3 in diagnostic mammography in the ACR National Mammography Database (NMD). METHODS: Retrospective analysis of NMD mammograms from January 1, 2009, to June 30, 2018, was performed. BI-RADS 3 utilization rate in diagnostic setting was calculated and stratified by patient, facility, and examination-level variables. Patient-level cancer yield was calculated among women with BI-RADS 3 assessment and adequate follow-up (imaging follow-up ≥24 months or biopsy). Logistic regression was performed to assess the odds of utilization of BI-RADS 3, with respect to facility, examination, and patient variables, and the odds of malignancy among patients with probably benign findings. Chi-square and t tests were used to determine significance (P < .05). RESULTS: Data from 19,443,866 mammograms from 500 NMD facilities across 31 states were analyzed, of which 3,039,952 were diagnostic mammograms. Utilization rate of BI-RADS 3 was 15.5% (470,155 of 3,039,952) in the diagnostic setting. There was a statistically significant difference in BI-RADS 3 utilization rate across all collected variables (P < .001). Patient-level cancer yield at 2-year follow-up was 0.91% (2,009 of 220,672; 95% confidence interval [CI], 0.87%-0.95%) in the diagnostic setting. Patient and examination variables associated with significantly higher likelihood of malignancy included calcifications (odds ratio, 4.27; 95% CI, 2.43-7.51), patient age > 70 years (odds ratio, 3.77; 95% CI, 2.49-5.7), and presence of prior comparisons (odds ratio, 1.23; 95% CI, 1.07-1.42). CONCLUSIONS: In the NMD, BI-RADS 3 assessment was common in diagnostic mammography (15.5%), with an overall cancer yield of 0.91%, less than the benchmark of 2%. Utilization trends in diagnostic mammography warrant further research for optimization of use.


Assuntos
Neoplasias da Mama , Mamografia , Idoso , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Bases de Dados Factuais , Feminino , Humanos , Masculino , Mamografia/métodos , Estudos Retrospectivos
5.
Radiology ; 300(3): 518-528, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34156300

RESUMO

Background Factors affecting radiologists' performance in screening mammography interpretation remain poorly understood. Purpose To identify radiologists characteristics that affect screening mammography interpretation performance. Materials and Methods This retrospective study included 1223 radiologists in the National Mammography Database (NMD) from 2008 to 2019 who could be linked to Centers for Medicare & Medicaid Services (CMS) datasets. NMD screening performance metrics were extracted. Acceptable ranges were defined as follows: recall rate (RR) between 5% and 12%; cancer detection rate (CDR) of at least 2.5 per 1000 screening examinations; positive predictive value of recall (PPV1) between 3% and 8%; positive predictive value of biopsies recommended (PPV2) between 20% and 40%; positive predictive value of biopsies performed (PPV3) between the 25th and 75th percentile of study sample; invasive CDR of at least the 25th percentile of the study sample; and percentage of ductal carcinoma in situ (DCIS) of at least the 25th percentile of the study sample. Radiologist characteristics extracted from CMS datasets included demographics, subspecialization, and clinical practice patterns. Multivariable stepwise logistic regression models were performed to identify characteristics independently associated with acceptable performance for the seven metrics. The most influential characteristics were defined as those independently associated with the majority of the metrics (at least four). Results Relative to radiologists practicing in the Northeast, those in the Midwest were more likely to achieve acceptable RR, PPV1, PPV2, and CDR (odds ratio [OR], 1.4-2.5); those practicing in the West were more likely to achieve acceptable RR, PPV2, and PPV3 (OR, 1.7-2.1) but less likely to achieve acceptable invasive CDR (OR, 0.6). Relative to general radiologists, breast imagers were more likely to achieve acceptable PPV1, invasive CDR, percentage DCIS, and CDR (OR, 1.4-4.4). Those performing diagnostic mammography were more likely to achieve acceptable PPV1, PPV2, PPV3, invasive CDR, and CDR (OR, 1.9-2.9). Those performing breast US were less likely to achieve acceptable PPV1, PPV2, percentage DCIS, and CDR (OR, 0.5-0.7). Conclusion The geographic location of the radiology practice, subspecialization in breast imaging, and performance of diagnostic mammography are associated with better screening mammography performance; performance of breast US is associated with lower performance. ©RSNA, 2021 Online supplemental material is available for this article.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Competência Clínica , Mamografia , Programas de Rastreamento , Radiologistas/normas , Bases de Dados Factuais , Detecção Precoce de Câncer , Feminino , Humanos , Área de Atuação Profissional , Especialização , Estados Unidos
6.
J Am Coll Radiol ; 18(10): 1394-1404, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34115990

RESUMO

OBJECTIVE: Kidney stones are common, tend to recur, and afflict a young population. Despite evidence and recommendations, adoption of reduced-radiation dose CT (RDCT) for kidney stone CT (KSCT) is slow. We sought to design and test an intervention to improve adoption of RDCT protocols for KSCT using a randomized facility-based intervention. METHODS: Facilities contributing at least 40 KSCTs to the American College of Radiology dose index registry (DIR) during calendar year 2015 were randomized to intervention or control groups. The Dose Optimization for Stone Evaluation intervention included customized CME modules, personalized consultation, and protocol recommendations for RDCT. Dose length product (DLP) of all KSCTs was recorded at baseline (2015) and compared with 2017, 2018, and 2019. Change in mean DLP was compared between facilities that participated (intervened-on), facilities randomized to intervention that did not participate (intervened-off), and control facilities. Difference-in-difference between intervened-on and control facilities is reported before and after intervention. RESULTS: Of 314 eligible facilities, 155 were randomized to intervention and 159 to control. There were 25 intervened-on facilities, 71 intervened-off facilities, and 96 control facilities. From 2015 to 2017, there was a drop of 110 mGy ∙ cm (a 16% reduction) in the mean DLP in the intervened-on group, which was significantly lower compared with the control group (P < .05). The proportion of RDCTs increased for each year in the intervened-on group relative to the other groups for all 3 years (P < .01). DISCUSSION: The Dose Optimization for Stone Evaluation intervention resulted in a significant (P < .05) and persistent reduction in mean radiation doses for engaged facilities performing KSCTs.


Assuntos
Redução da Medicação , Cálculos Renais , Humanos , Rim , Cálculos Renais/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X
7.
Health Phys ; 116(2): 138-142, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30585954

RESUMO

There is a substantial infrastructure for quality and safety in radiologic imaging, built over decades, that is available to practices and providers. The purpose of this review is to provide an overview of those resources and place them in the context of patient care. Successful application of these resources requires both the technology as well as the culture to use the techniques. We are beginning to see more tools to support the culture change necessary to take advantage of the resources, and increased attention to the patient perspective.


Assuntos
Segurança do Paciente , Radiografia/normas , Previsões , Humanos , Segurança do Paciente/normas , Radiografia/efeitos adversos , Radiografia/métodos
8.
Radiology ; 287(2): 416-422, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29315061

RESUMO

Purpose To determine the utilization and positive predictive value (PPV) of the American College of Radiology (ACR) Breast Imaging Data and Reporting System (BI-RADS) category 4 subdivisions in diagnostic mammography in the National Mammography Database (NMD). Materials and Methods This study involved retrospective review of diagnostic mammography data submitted to the NMD from January 1, 2008 to December 30, 2014. Utilization rates of BI-RADS category 4 subdivisions were compared by year, facility (type, location, census region), and examination (indication, finding type) characteristics. PPV3 (positive predictive value for biopsies performed) was calculated overall and according to category 4 subdivision. The χ2 test was used to test for significant associations. Results Of 1 309 950 diagnostic mammograms, 125 447 (9.6%) were category 4, of which 33.3% (41 841 of 125 447) were subdivided. Subdivision utilization rates were higher (P < .001) in practices that were community, suburban, or in the West; for examination indication of prior history of breast cancer; and for the imaging finding of architectural distortion. Of 41 841 category 4 subdivided examinations, 4A constituted 55.6% (23 258 of 41 841) of the examinations; 4B, 31.8% (13 302 of 41 841) of the examinations; and 4C, 12.6% (5281 of 41 841) of the examinations. Pathologic outcomes were available in 91 563 examinations, and overall category 4 PPV3 was 21.1% (19 285 of 91 563). There was a statistically significant difference in PPV3 according to category 4 subdivision (P < .001): The PPV of 4A was 7.6% (1274 of 16 784), that of 4B was 22% (2317 of 10 408), and that of 4C was 69.3% (2839 of 4099). Conclusion Although BI-RADS suggests their use, subdivisions were utilized in the minority (33.3% [41 841 of 125 447]) of category 4 diagnostic mammograms, with variability based on facility and examination characteristics. When subdivisions were used, PPV3s were in BI-RADS-specified malignancy ranges. This analysis supports the use of subdivisions in broad practice and, given benefits for patient care, should motivate increased utilization. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/instrumentação , Mamografia , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Feminino , Humanos , Mamografia/estatística & dados numéricos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Avaliação de Resultados em Cuidados de Saúde , Vigilância da População , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estados Unidos
9.
AJR Am J Roentgenol ; 210(3): 641-647, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29323552

RESUMO

OBJECTIVE: Imaging registries afford opportunities to study large, heterogeneous populations. The purpose of this study was to examine the American College of Radiology CT Dose Index Registry (DIR) for dose-related demographics and metrics of common pediatric body CT examinations. MATERIALS AND METHODS: Single-phase CT examinations of the abdomen and pelvis and chest submitted to the DIR over a 5-year period (July 2011-June 2016) were evaluated (head CT frequency was also collected). CT examinations were stratified into five age groups, and examination frequency was determined across age and sex. Standard dose indexes (volume CT dose index, dose-length product, and size-specific dose estimate) were categorized by body part and age. Contributions to the DIR were also categorized by region and practice type. RESULTS: Over the study period 411,655 single-phase pediatric examinations of the abdomen and pelvis, chest, and head, constituting 5.7% of the total (adult and pediatric) examinations, were submitted to the DIR. Head CT was the most common examination across all age groups. The majority of all scan types were performed for patients in the second decade of life. Dose increased for all scan types as age increased; the dose for abdominopelvic CT was the highest in each age group. Even though the DIR was queried for single-phase examinations only, as many as 32.4% of studies contained multiple irradiation events. When these additional scans were included, the volume CT dose index for each scan type increased. Among the studies in the DIR, 99.8% came from institutions within the United States. Community practices and those that specialize in pediatrics were nearly equally represented. CONCLUSION: The DIR provides valuable information about practice patterns and dose trends for pediatric CT and may assist in establishing diagnostic reference levels in the pediatric population.


Assuntos
Guias de Prática Clínica como Assunto , Padrões de Prática Médica/estatística & dados numéricos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Radiografia Abdominal , Radiografia Torácica , Sistema de Registros , Estados Unidos
10.
Radiology ; 286(2): 581-589, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28858562

RESUMO

Purpose To determine if the use of reduced-dose computed tomography (CT) for evaluation of kidney stones increased in 2015-2016 compared with that in 2011-2012, to determine variability in radiation exposure according to facility for this indication, and to establish a current average radiation dose for CT evaluation for kidney stones by querying a national dose registry. Materials and Methods This cross-sectional study was exempt from institutional review board approval. Data were obtained from the American College of Radiology dose registry for CT examinations submitted from July 2015 to June 2016. Study descriptors consistent with single-phase unenhanced CT for evaluation of kidney stones and associated RadLex® Playbook identifiers (RPIDs) were retrospectively identified. Facilities actively submitting data on kidney stone-specific CT examinations were included. Dose metrics including volumetric CT dose index, dose-length product, and size-specific dose estimate, when available, were reported, and a random effects model was run to account for clustering of CT examinations at facilities. A z-ratio was calculated to test for a significant difference between the proportion of reduced-radiation dose CT examinations (defined as those with a dose-length product of 200 mGy · cm or less) performed in 2015-2016 and the proportion performed in 2011-2012. Results Three hundred four study descriptors for kidney stone CT corresponding to data from 328 facilities that submitted 105 334 kidney stone CT examinations were identified. Reduced-dose CT examinations accounted for 8040 of 105 334 (7.6%) CT examinations, a 5.6% increase from the 1010 of 49 903 (2%) examinations in 2011-2012 (P < .001). Mean overall dose-length product was 689 mGy · cm (95% confidence interval: 667, 712), decreased from the mean of 746 mGy · cm observed in 2011-2012. Median facility dose-length product varied up to sevenfold, from less than 200 mGy · cm to greater than 1600 mGy · cm. Conclusion Use of reduced-radiation dose CT for evaluation of kidney stones has increased since 2011-2012, but remains low; variability of radiation dose according to facility continues to be wide. National mean CT radiation exposure for evaluation of renal colic during 2015-2016 decreased relative to 2011-2012 values, but remained well above what is reasonably achievable. © RSNA, 2017.


Assuntos
Cálculos Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Doses de Radiação , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/tendências
11.
Radiology ; 286(1): 173-185, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091751

RESUMO

Purpose To determine in a large multicenter multireader setting the interreader reliability of Liver Imaging Reporting and Data System (LI-RADS) version 2014 categories, the major imaging features seen with computed tomography (CT) and magnetic resonance (MR) imaging, and the potential effect of reader demographics on agreement with a preselected nonconsecutive image set. Materials and Methods Institutional review board approval was obtained, and patient consent was waived for this retrospective study. Ten image sets, comprising 38-40 unique studies (equal number of CT and MR imaging studies, uniformly distributed LI-RADS categories), were randomly allocated to readers. Images were acquired in unenhanced and standard contrast material-enhanced phases, with observation diameter and growth data provided. Readers completed a demographic survey, assigned LI-RADS version 2014 categories, and assessed major features. Intraclass correlation coefficient (ICC) assessed with mixed-model regression analyses was the metric for interreader reliability of assigning categories and major features. Results A total of 113 readers evaluated 380 image sets. ICC of final LI-RADS category assignment was 0.67 (95% confidence interval [CI]: 0.61, 0.71) for CT and 0.73 (95% CI: 0.68, 0.77) for MR imaging. ICC was 0.87 (95% CI: 0.84, 0.90) for arterial phase hyperenhancement, 0.85 (95% CI: 0.81, 0.88) for washout appearance, and 0.84 (95% CI: 0.80, 0.87) for capsule appearance. ICC was not significantly affected by liver expertise, LI-RADS familiarity, or years of postresidency practice (ICC range, 0.69-0.70; ICC difference, 0.003-0.01 [95% CI: -0.003 to -0.01, 0.004-0.02]. ICC was borderline higher for private practice readers than for academic readers (ICC difference, 0.009; 95% CI: 0.000, 0.021). Conclusion ICC is good for final LI-RADS categorization and high for major feature characterization, with minimal reader demographic effect. Of note, our results using selected image sets from nonconsecutive examinations are not necessarily comparable with those of prior studies that used consecutive examination series. © RSNA, 2017.


Assuntos
Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Radiologistas/estatística & dados numéricos , Radiologistas/normas , Bases de Dados Factuais , Humanos , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
Radiology ; 280(3): 701-6, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27018643

RESUMO

Purpose To evaluate the impact of breast density notification legislation on breast density reporting by radiologists nationally. Materials and Methods The institutional review board exempted this HIPAA-compliant retrospective study from the requirement for informed consent. State-level data over a 5-year period on breast density categorization and breast cancer detection rate were collected from the National Mammography Database (NMD). Z tests were used to calculate differences in proportions. Results Facilities in 13 of 17 states that had breast density notification legislation as of 2014 submitted data to the NMD before and after law enactment. A total of 1 333 541 mammographic studies (hereafter called "mammograms") over a 30-month period, beginning 20 months before and continuing 10 months after law enactment, were included in the analysis. There was a small but statistically significant decrease in the percentage of mammograms reported as showing dense breast tissue (hereafter called "dense mammograms") in the month before law enactment compared with the month after (43.0% [22 338 of 52 000] vs 40.0% [18 604 of 46 464], P < .001). There was no statistically significant difference in the percentage of mammograms reported as dense in the month before law enactment compared with the 10th month after (43.0% [22 338 of 52 000] vs 42.8% [15 835 of 36 991], P = .65). There were no significant differences in the breast cancer detection rate between the month before and the month after law enactment (3.9 vs 3.8 cancers per 1000 mammograms, P = .79) or between the month before law enactment and the 10th month after (3.9 vs 4.2 cancers per 1000 mammograms, P = .55). In 21 analyzed states without breast density notification legislation, the percentage of mammograms reported as dense did not decrease below 42.8% (43 363 of 101 394) from 2010 to 2014, in contrast to 13 analyzed states with breast density notification legislation, which reached a nadir of 39.3% (20 965 of 53 360) (P < .001). Conclusion The percentage of mammograms reported as dense slightly decreased immediately after enactment of breast density notification legislation but then returned to prelegislation percentages within 10 months. (©) RSNA, 2016.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Notificação de Doenças/legislação & jurisprudência , Padrões de Prática Médica/legislação & jurisprudência , Adulto , Idoso , Detecção Precoce de Câncer , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Estudos Retrospectivos , Estados Unidos
14.
AJR Am J Roentgenol ; 206(4): 883-90, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26866649

RESUMO

OBJECTIVE: The purposes of our study were to analyze screening mammography data submitted to the National Mammography Database (NMD) since its inception to confirm data collection feasibility, to draw parallels to data from the Breast Cancer Surveillance Consortium (BCSC), and to examine trends over time. We also retrospectively evaluated practice-level variation in terms of practice type, practice setting, census region, and annual volume. MATERIALS AND METHODS: Data from 90 mammography facilities in the NMD registry were analyzed. The registry receives mammography data collected as part of standard clinical practice, including self-reported demographic information, clinical findings, screening mammography interpretation, and biopsy results. Outcome metrics calculated were cancer detection rate, recall rate, and positive predictive values for biopsy recommended (PPV2) and biopsy performed (PPV3). RESULTS: The NMD successfully collected and analyzed data for 3,181,437 screening mammograms performed between January 2008 and December 2012. Mean values for outcomes were cancer detection rate of 3.43 per 1000 (95% CI, 3.2-3.7), recall rate of 10% (95% CI, 9.3-10.7%), PPV2 of 18.5% (95% CI, 16.7-20.2%), and PPV3 of 29.2% (95% CI, 26.2-32.3%). No statistically significant difference was seen in performance measurements on the basis of practice type, practice setting, census region, or annual volume. NMD performance measurements parallel those reported by the BCSC. CONCLUSION: The NMD has become the fastest growing mammography registry in the United States, providing nationwide performance metrics and permitting comparison with published benchmarks. Our study shows the feasibility of using the NMD to audit mammography facilities and to provide current, ongoing benchmark data.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Bases de Dados Factuais , Mamografia , Benchmarking , Neoplasias da Mama/epidemiologia , Detecção Precoce de Câncer , Feminino , Humanos , Programas de Rastreamento , Vigilância da População , Sistema de Registros , Estados Unidos/epidemiologia
15.
Acad Emerg Med ; 22(12): 1499-505, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26568459

RESUMO

OBJECTIVES: The objective was to evaluate variation in the current estimated radiation dose index for pediatric cervical spine (c-spine) computed tomography (CT) examinations. METHODS: This was a retrospective analysis of pediatric (age younger than 19 years) c-spine CT examinations from the American College of Radiology Dose Index Registry, July 2011 through December 2014. We used the volume CT dose index (CTDIvol) as the radiation dose estimate and used summary statistics to describe patient and hospital characteristics. RESULTS: There were 12,218 pediatric CT c-spine examinations performed across 296 participating hospitals. Fifty-six percent were in male patients, and 79% were in children older than 10 years. Most hospitals (55%) were community hospitals without trauma designations, and the largest proportion of examinations (41%) were performed at these hospitals. The median CTDIvol was 15 mGy (interquartile range = 9 to 23 mGy) representing a more than 2.5-fold difference between the 25th and 75th percentiles. Pediatric hospitals (both trauma and nontrauma centers) delivered the lowest CTDIvol across all age groups and showed the least amount of variability in dose. CONCLUSIONS: There is significant variation in the radiation dose index for pediatric c-spine CT examinations. Pediatric hospitals practice at lower CT dose estimates than other hospitals. Individual hospitals should examine their practices in an effort to ensure standardization and optimization of CT parameters to minimize radiation exposures to pediatric patients.


Assuntos
Vértebras Cervicais/diagnóstico por imagem , Hospitais Comunitários/estatística & dados numéricos , Hospitais Pediátricos/estatística & dados numéricos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pescoço/diagnóstico por imagem , Estudos Retrospectivos
16.
Radiology ; 271(2): 445-51, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24484064

RESUMO

PURPOSE: To determine radiation dose indexes for computed tomography (CT) performed with renal colic protocols in the United States, including frequency of reduced-dose technique usage and any institutional-level factors associated with high or low dose indexes. MATERIALS AND METHODS: The Dose Imaging Registry (DIR) collects deidentified CT data, including examination type and dose indexes, for CT performed at participating institutions; thus, the DIR portion of the study was exempt from institutional review board approval and was HIPAA compliant. CT dose indexes were examined at the institutional level for CT performed with a renal colic protocol at institutions that contributed at least 10 studies to the registry as of January 2013. Additionally, patients undergoing CT for renal colic at a single institution (with institutional review board approval and informed consent from prospective subjects and waiver of consent from retrospective subjects) were studied to examine individual renal colic CT dose index patterns and explore relationships between patient habitus, demographics, and dose indexes. Descriptive statistics were used to analyze dose indexes, and linear regression and Spearman correlations were used to examine relationships between dose indexes and institutional factors. RESULTS: There were 49 903 renal colic protocol CT examinations conducted at 93 institutions between May 2011 and January 2013. Mean age ± standard deviation was 49 years ± 18, and 53.9% of patients were female. Institutions contributed a median of 268 (interquartile range, 77-699) CT studies. Overall mean institutional dose-length product (DLP) was 746 mGy ⋅ cm (effective dose, 11.2 mSv), with a range of 307-1497 mGy ⋅ cm (effective dose, 4.6-22.5 mSv) for mean DLPs. Only 2% of studies were conducted with a DLP of 200 mGy ⋅ cm or lower (a "reduced dose") (effective dose, 3 mSv), and only 10% of institutions kept DLP at 400 mGy ⋅ cm (effective dose, 6 mSv) or less in at least 50% of patients. CONCLUSION: Reduced-dose renal protocol CT is used infrequently in the United States. Mean dose index is higher than reported previously, and institutional variation is substantial.


Assuntos
Doses de Radiação , Cólica Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA