Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Molecules ; 29(4)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38398551

RESUMO

Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac)2], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 (48V) generated with a compact medical cyclotron has been used to label VO(acac)2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac)2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac)2, [48V]VO(acac)2, and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [48V]VO(acac)2. Preliminary results of preclinical, small-animal PET studies are presented.


Assuntos
Hidroxibutiratos , Neoplasias , Pentanonas , Radioisótopos , Vanádio , Animais , Cromatografia Líquida de Alta Pressão , Vanádio/química , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons
2.
Int J Mol Sci ; 24(21)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37958495

RESUMO

Positron emission tomography (PET) radioligands that bind with high-affinity to α4ß2-type nicotinic receptors (α4ß2Rs) allow for in vivo investigations of the mechanisms underlying nicotine addiction and smoking cessation. Here, we investigate the use of an image-derived arterial input function and the cerebellum for kinetic analysis of radioligand binding in mice. Two radioligands were explored: 2-[18F]FA85380 (2-FA), displaying similar pKa and binding affinity to the smoking cessation drug varenicline (Chantix), and [18F]Nifene, displaying similar pKa and binding affinity to nicotine. Time-activity curves of the left ventricle of the heart displayed similar distribution across wild type mice, mice lacking the ß2-subunit for ligand binding, and acute nicotine-treated mice, whereas reference tissue binding displayed high variation between groups. Binding potential estimated from a two-tissue compartment model fit of the data with the image-derived input function were higher than estimates from reference tissue-based estimations. Rate constants of radioligand dissociation were very slow for 2-FA and very fast for Nifene. We conclude that using an image-derived input function for kinetic modeling of nicotinic PET ligands provides suitable results compared to reference tissue-based methods and that the chemical properties of 2-FA and Nifene are suitable to study receptor response to nicotine addiction and smoking cessation therapies.


Assuntos
Receptores Nicotínicos , Tabagismo , Camundongos , Animais , Nicotina/farmacologia , Nicotina/metabolismo , Encéfalo/metabolismo , Tabagismo/metabolismo , Cinética , Ligantes , Tomografia por Emissão de Pósitrons/métodos , Receptores Nicotínicos/genética , Receptores Nicotínicos/metabolismo
3.
Molecules ; 28(16)2023 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-37630292

RESUMO

In the field of nuclear medicine, the ß+ -emitting 43Sc and ß- -emitting 47Sc are promising candidates in cancer diagnosis and targeted radionuclide therapy (TRT) due to their favorable decay schema and shared pharmacokinetics as a true theranostic pair. Additionally, scandium is a group-3 transition metal (like 177Lu) and exhibits affinity for DOTA-based chelators, which have been studied in depth, making the barrier to implementation lower for 43/47Sc than for other proposed true theranostics. Before 43/47Sc can see widespread pre-clinical evaluation, however, an accessible production methodology must be established and each isotope's radiolabeling and animal imaging capabilities studied with a widely utilized tracer. As such, a simple means of converting an 18 MeV biomedical cyclotron to support solid targets and produce 43Sc via the 42Ca(d,n)43Sc reaction has been devised, exhibiting reasonable yields. The NatTi(γ,p)47Sc reaction is also investigated along with the successful implementation of chemical separation and purification methods for 43/47Sc. The conjugation of 43/47Sc with PSMA-617 at specific activities of up to 8.94 MBq/nmol and the subsequent imaging of LNCaP-ENZaR tumor xenografts in mouse models with both 43/47Sc-PSMA-617 are also presented.


Assuntos
Medicina Nuclear , Neoplasias da Próstata , Humanos , Animais , Camundongos , Masculino , Escândio , Medicina de Precisão , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioisótopos/uso terapêutico
4.
J Neurosci ; 43(1): 2-13, 2023 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-36028313

RESUMO

A question relevant to nicotine addiction is how nicotine and other nicotinic receptor membrane-permeant ligands, such as the anti-smoking drug varenicline (Chantix), distribute in brain. Ligands, like varenicline, with high pKa and high affinity for α4ß2-type nicotinic receptors (α4ß2Rs) are trapped in intracellular acidic vesicles containing α4ß2Rs in vitro Nicotine, with lower pKa and α4ß2R affinity, is not trapped. Here, we extend our results by imaging nicotinic PET ligands in vivo in male and female mouse brain and identifying the trapping brain organelle in vitro as Golgi satellites (GSats). Two PET 18F-labeled imaging ligands were chosen: [18F]2-FA85380 (2-FA) with varenicline-like pKa and affinity and [18F]Nifene with nicotine-like pKa and affinity. [18F]2-FA PET-imaging kinetics were very slow consistent with 2-FA trapping in α4ß2R-containing GSats. In contrast, [18F]Nifene kinetics were rapid, consistent with its binding to α4ß2Rs but no trapping. Specific [18F]2-FA and [18F]Nifene signals were eliminated in ß2 subunit knock-out (KO) mice or by acute nicotine (AN) injections demonstrating binding to sites on ß2-containing receptors. Chloroquine (CQ), which dissipates GSat pH gradients, reduced [18F]2-FA distributions while having little effect on [18F]Nifene distributions in vivo consistent with only [18F]2-FA trapping in GSats. These results are further supported by in vitro findings where dissipation of GSat pH gradients blocks 2-FA trapping in GSats without affecting Nifene. By combining in vitro and in vivo imaging, we mapped both the brain-wide and subcellular distributions of weak-base nicotinic receptor ligands. We conclude that ligands, such as varenicline, are trapped in neurons in α4ß2R-containing GSats, which results in very slow release long after nicotine is gone after smoking.SIGNIFICANCE STATEMENT Mechanisms of nicotine addiction remain poorly understood. An earlier study using in vitro methods found that the anti-smoking nicotinic ligand, varenicline (Chantix) was trapped in α4ß2R-containing acidic vesicles. Using a fluorescent-labeled high-affinity nicotinic ligand, this study provided evidence that these intracellular acidic vesicles were α4ß2R-containing Golgi satellites (GSats). In vivo PET imaging with F-18-labeled nicotinic ligands provided additional evidence that differences in PET ligand trapping in acidic vesicles were the cause of differences in PET ligand kinetics and subcellular distributions. These findings combining in vitro and in vivo imaging revealed new mechanistic insights into the kinetics of weak base PET imaging ligands and the subcellular mechanisms underlying nicotine addiction.


Assuntos
Receptores Nicotínicos , Tabagismo , Camundongos , Animais , Masculino , Feminino , Nicotina/farmacologia , Vareniclina/metabolismo , Vareniclina/farmacologia , Tabagismo/metabolismo , Ligantes , Receptores Nicotínicos/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/metabolismo
5.
Eur J Nucl Med Mol Imaging ; 49(12): 4014-4024, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35792927

RESUMO

PURPOSE: To identify the optimal threshold in 18F-fluoromisonidazole (FMISO) PET images to accurately locate tumor hypoxia by using electron paramagnetic resonance imaging (pO2 EPRI) as ground truth for hypoxia, defined by pO2 [Formula: see text] 10 mmHg. METHODS: Tumor hypoxia images in mouse models of SCCVII squamous cell carcinoma (n = 16) were acquired in a hybrid PET/EPRI imaging system 2 h post-injection of FMISO. T2-weighted MRI was used to delineate tumor and muscle tissue. Dynamic contrast enhanced (DCE) MRI parametric images of Ktrans and ve were generated to model tumor vascular properties. Images from PET/EPR/MRI were co-registered and resampled to isotropic 0.5 mm voxel resolution for analysis. PET images were converted to standardized uptake value (SUV) and tumor-to-muscle ratio (TMR) units. FMISO uptake thresholds were evaluated using receiver operating characteristic (ROC) curve analysis to find the optimal FMISO threshold and unit with maximum overall hypoxia similarity (OHS) with pO2 EPRI, where OHS = 1 shows perfect overlap and OHS = 0 shows no overlap. The means of dice similarity coefficient, normalized Hausdorff distance, and accuracy were used to define the OHS. Monotonic relationships between EPRI/PET/DCE-MRI were evaluated with the Spearman correlation coefficient ([Formula: see text]) to quantify association of vasculature on hypoxia imaged with both FMISO PET and pO2 EPRI. RESULTS: FMISO PET thresholds to define hypoxia with maximum OHS (both OHS = 0.728 [Formula: see text] 0.2) were SUV [Formula: see text] 1.4 [Formula: see text] SUVmean and SUV [Formula: see text] 0.6 [Formula: see text] SUVmax. Weak-to-moderate correlations (|[Formula: see text]|< 0.70) were observed between PET/EPRI hypoxia images with vascular permeability (Ktrans) or fractional extracellular-extravascular space (ve) from DCE-MRI. CONCLUSION: This is the first in vivo comparison of FMISO uptake with pO2 EPRI to identify the optimal FMISO threshold to define tumor hypoxia, which may successfully direct hypoxic tumor boosts in patients, thereby enhancing tumor control.


Assuntos
Carcinoma de Células Escamosas , Hipóxia Tumoral , Animais , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Hipóxia Celular , Espectroscopia de Ressonância de Spin Eletrônica , Hipóxia/diagnóstico por imagem , Camundongos , Misonidazol/análogos & derivados , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
6.
Appl Radiat Isot ; 186: 110270, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35569262

RESUMO

In this preliminary study, a procedure for synthesizing novel PET radiotracer vanadium-48-labeled-vanadyl acetylacetonate was developed, including radioisotope production via cyclotron, separation of 48V, chelation as 48VO(acac)2, and assessment through in vitro cellular studies. We employed the beam-stop setup in a cyclotron as the target holder to irradiate titanium foils in the reaction of natTi (p,n)48V. The radioisotope production rate was 4.84 ± 0.67 µCi/µA-h. Overall radiochemical yield was 12.86 ± 0.51% with gamma-ray spectroscopy showing no detectable contaminant peaks. HPLC of 48VO(acac)2 showed a retention time (1:48) corresponding closely to that (1:50) of commercial VO(acac)2, verifying the successful synthesis of 48VO(acac)2. In vitro cellular studies demonstrated radiotracer uptake and saturation around 0.48 nM. These studies pave the way for improving methodologies and in vivo experiments, including imaging studies, in future investigations.


Assuntos
Neoplasias , Humanos , Neoplasias/diagnóstico por imagem , Análise Espectral
7.
J Prim Care Community Health ; 13: 21501319211062672, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34986700

RESUMO

OBJECTIVES: The purpose of the present study was to assess and describe the severity of symptoms reported by Covid-19 positive patients who vaped (smoked e-cigarettes) when compared to those who did not vape or smoke at the time of the diagnosis of Covid-19. METHODS: Patients from this study are from a well-characterized patient cohort collected at Mayo Clinic between March 1, 2020 and February 28, 2021; with confirmed COVID-19 diagnosis defined as a positive result on reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assays from nasopharyngeal swab specimens. Among the 1734 eligible patients, 289 patients reported current vaping. The cohort of vapers (N = 289) was age and gender matched to 1445 covid-19 positive patients who did not vape. The data analyzed included: date of birth, gender, ethnicity, race, marital status, as well as lifestyle history such as vaping and smoking and reported covid-19 symptoms experienced. RESULTS: A logistic regression analysis was performed separately for each symptom using generalized estimating equations (GEE) with robust variance estimates in order to account for the 1:5 age, sex, and race matched set study design. Patients who vaped and developed Covid-19 infection were more likely to have chest pain or tightness (16% vs 10%, vapers vs non vapers, P = .005), chills (25% vs 19%, vapers vs non vapers, P = .0016), myalgia (39% vs 32%, vapers vs non vapers, P = .004), headaches (49% vs 41% vapers vs non vapers, P = .026), anosmia/dysgeusia (37% vs 30%, vapers vs non vapers, P = .009), nausea/vomiting/abdominal pain (16% vs 10%, vapers vs non vapers, P = .003), diarrhea (16% vs 10%, vapers vs non vapers, P = .004), and non-severe light-headedness (16% vs 9%, vapers vs non vapers, P < .001). CONCLUSION: Vapers experience higher frequency of covid-19 related symptoms when compared with age and gender matched non-vapers. Further work should examine the impact vaping has on post-covid symptom experience.


Assuntos
COVID-19 , Sistemas Eletrônicos de Liberação de Nicotina , Teste para COVID-19 , Humanos , SARS-CoV-2 , Fumantes
8.
Diagnostics (Basel) ; 13(1)2022 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-36611361

RESUMO

Deep learning-based automatic classification of breast tumors using parametric imaging techniques from ultrasound (US) B-mode images is still an exciting research area. The Rician inverse Gaussian (RiIG) distribution is currently emerging as an appropriate example of statistical modeling. This study presents a new approach of correlated-weighted contourlet-transformed RiIG (CWCtr-RiIG) and curvelet-transformed RiIG (CWCrv-RiIG) image-based deep convolutional neural network (CNN) architecture for breast tumor classification from B-mode ultrasound images. A comparative study with other statistical models, such as Nakagami and normal inverse Gaussian (NIG) distributions, is also experienced here. The weighted entitled here is for weighting the contourlet and curvelet sub-band coefficient images by correlation with their corresponding RiIG statistically modeled images. By taking into account three freely accessible datasets (Mendeley, UDIAT, and BUSI), it is demonstrated that the proposed approach can provide more than 98 percent accuracy, sensitivity, specificity, NPV, and PPV values using the CWCtr-RiIG images. On the same datasets, the suggested method offers superior classification performance to several other existing strategies.

9.
Radiol Imaging Cancer ; 3(2): e200104, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33817651

RESUMO

Purpose: To enhance the spatial accuracy of fluorine 18 (18F) misonidazole (MISO) PET imaging of hypoxia by using dynamic contrast-enhanced (DCE) MR images as a basis for modifying PET images and by using electron paramagnetic resonance (EPR) partial oxygen pressure (pO2) as the reference standard. Materials and Methods: Mice (n = 10) with leg-borne MCa4 mammary carcinomas underwent EPR imaging, T2-weighted and DCE MRI, and 18F-MISO PET/CT. Images were registered to the same space for analysis. The thresholds of hypoxia for PET and EPR images were tumor-to-muscle ratios greater than or equal to 2.2 mm Hg and less than or equal to 14 mm Hg, respectively. The Dice similarity coefficient (DSC) and Hausdorff distance (d H ) were used to quantify the three-dimensional overlap of hypoxia between pO2 EPR and 18F-MISO PET images. A training subset (n = 6) was used to calculate optimal DCE MRI weighting coefficients to relate EPR to the PET signal; the group average weights were then applied to all tumors (from six training mice and four test mice). The DSC and d H were calculated before and after DCE MRI-corrected PET images were obtained to quantify the improvement in overlap with EPR pO2 images for measuring tumor hypoxia. Results: The means and standard deviations of the DSC and d H between hypoxic regions in original PET and EPR images were 0.35 mm ± 0.23 and 5.70 mm ± 1.7, respectively, for images of all 10 mice. After implementing a preliminary DCE MRI correction to PET data, the DSC increased to 0.86 mm ± 0.18 and the d H decreased to 2.29 mm ± 0.70, showing significant improvement (P < .001) for images of all 10 mice. Specifically, for images of the four independent test mice, the DSC improved with correction from 0.19 ± 0.28 to 0.80 ± 0.29 (P = .02), and the d H improved from 6.40 mm ± 2.5 to 1.95 mm ± 0.63 (P = .01). Conclusion: Using EPR information as a reference standard, DCE MRI information can be used to correct 18F-MISO PET information to more accurately reflect areas of hypoxia.Keywords: Animal Studies, Molecular Imaging, Molecular Imaging-Cancer, PET/CT, MR-Dynamic Contrast Enhanced, MR-Imaging, PET/MR, Breast, Oncology, Tumor Mircoenvironment, Electron Paramagnetic ResonanceSupplemental material is available for this article.© RSNA, 2021.


Assuntos
Misonidazol , Hipóxia Tumoral , Animais , Espectroscopia de Ressonância de Spin Eletrônica , Hipóxia/diagnóstico por imagem , Imageamento por Ressonância Magnética , Camundongos , Oxigênio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons
10.
Angew Chem Int Ed Engl ; 59(35): 15161-15165, 2020 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-32415874

RESUMO

Herein, we report the development of an 18 F-labeled, activity-based small-molecule probe targeting the cancer-associated serine hydrolase NCEH1. We undertook a focused medicinal chemistry campaign to simultaneously preserve potent and specific NCEH1 labeling in live cells and animals, while permitting facile 18 F radionuclide incorporation required for PET imaging. The resulting molecule, [18 F]JW199, labels active NCEH1 in live cells at nanomolar concentrations and greater than 1000-fold selectivity relative to other serine hydrolases. [18 F]JW199 displays rapid, NCEH1-dependent accumulation in mouse tissues. Finally, we demonstrate that [18 F]JW199 labels aggressive cancer tumor cells in vivo, which uncovered localized NCEH1 activity at the leading edge of triple-negative breast cancer tumors, suggesting roles for NCEH1 in tumor aggressiveness and metastasis.


Assuntos
Radioisótopos de Flúor/uso terapêutico , Tomografia por Emissão de Pósitrons/métodos , Esterol Esterase/metabolismo , Animais , Feminino , Humanos , Camundongos
11.
ACS Sens ; 1(8): 975-978, 2016 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-28066811

RESUMO

A hallmark of the tumor microenvironment in malignant tumor is extracellular acidosis, which can be exploited for targeted delivery of drugs and imaging agents. A pH sensitive paramagnetic nanoaparticle (NP) is developed by incorporating GdDOTA-4AmP MRI contrast agent and pHLIP (pH Low Insertion Peptide) into the surface of a G5-PAMAM dendrimer. pHLIP showed pH-selective insertion and folding into cell membranes, but only in acidic conditions. We demonstrated that pHLIP-conjugated Gd44-G5 paramagnetic nanoparticle binds and fuses with cellular membrane at low pH, but not at normal physiological pH, and that it promotes cellular uptake. Intracellular trafficking of NPs showed endosomal/lysosomal path ways.

12.
Contrast Media Mol Imaging ; 10(6): 481-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26173742

RESUMO

The measurement of extracellular pH (pHe ) has significant clinical value for pathological diagnoses and for monitoring the effects of pH-altering therapies. One of the major problems of measuring pHe with a relaxation-based MRI contrast agent is that the longitudinal relaxivity depends on both pH and the concentration of the agent, requiring the use of a second pH-unresponsive agent to measure the concentration. Here we tested the feasibility of measuring pH with a relaxation-based dendritic MRI contrast agent in a concentration-independent manner at clinically relevant field strengths. The transverse and longitudinal relaxation times in solutions of the contrast agent (GdDOTA-4AmP)44 -G5, a G5-PAMAM dendrimer-based MRI contrast agent in water, were measured at 3 T and 7 T magnetic field strengths as a function of pH. At 3 T, longitudinal relaxivity (r1 ) increased from 7.91 to 9.65 mM(-1) s(-1) (on a per Gd(3+) basis) on changing pH from 8.84 to 6.35. At 7 T, r1 relaxivity showed pH response, albeit at lower mean values; transverse relaxivity (r2 ) remained independent of pH and magnetic field strengths. The longitudinal relaxivity of (GdDOTA-4AmP)44 -G5 exhibited a strong and reversible pH dependence. The ratio of relaxation rates R2 /R1 also showed a linear relationship in a pH-responsive manner, and this pH response was independent of the absolute concentration of (GdDOTA-4AmP)44 -G5 agent. Importantly, the nanoprobe (GdDOTA-4AmP)44 -G5 shows pH response in the range commonly found in the microenvironment of solid tumors.


Assuntos
Meios de Contraste/química , Líquido Extracelular/química , Compostos Heterocíclicos com 1 Anel/química , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos/química , Animais , Dendrímeros/química , Gadolínio/química , Concentração de Íons de Hidrogênio , Nanoestruturas/química , Água
13.
PLoS One ; 9(4): e94122, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24713808

RESUMO

Disulfide-rich peptide toxins found in the secretions of venomous organisms such as snakes, spiders, scorpions, leeches, and marine snails are highly efficient and effective tools for novel therapeutic drug development. Venom peptide toxins have been used extensively to characterize ion channels in the nervous system and platelet aggregation in haemostatic systems. A significant hurdle in characterizing disulfide-rich peptide toxins from venomous animals is obtaining significant quantities needed for sequence and structural analyses. Presented here is a strategy for the structural characterization of venom peptide toxins from sample limited (4 ng) specimens via direct mass spectrometry sequencing, chemical synthesis and NMR structure elucidation. Using this integrated approach, venom peptide Tv1 from Terebra variegata was discovered. Tv1 displays a unique fold not witnessed in prior snail neuropeptides. The novel structural features found for Tv1 suggest that the terebrid pool of peptide toxins may target different neuronal agents with varying specificities compared to previously characterized snail neuropeptides.


Assuntos
Dissulfetos/análise , Gastrópodes , Peptídeos/química , Toxinas Biológicas/química , Peçonhas/química , Animais , Espectroscopia de Ressonância Magnética , Espectrometria de Massas
14.
Am J Trop Med Hyg ; 89(2): 345-53, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23817330

RESUMO

We conducted active surveillance for kala-azar and post-kala-azar dermal leishmaniasis (PKDL) in a population of 24,814 individuals. Between 2002 and 2010, 1,002 kala-azar and 185 PKDL cases occurred. Median PKDL patient age was 12 years; 9% had no antecedent kala-azar. Cases per 10,000 person-years peaked at 90 for kala-azar (2005) and 28 for PKDL (2007). Cumulative PKDL incidence among kala-azar patients was 17% by 5 years. Kala-azar patients younger than 15 years were more likely than older patients to develop PKDL; no other risk factors were identified. The most common lesions were hypopigmented macules. Of 98 untreated PKDL patients, 48 (49%) patients had resolution, with median time of 19 months. Kala-azar patients showed elevated interferon-γ (IFNγ), tumor necrosis factor-α (TNFα), and interleukin 10 (IL-10). Matrix metalloproteinase 9 (MMP9) and MMP9/tissue inhibitor of matrix metalloproteinase-1 (TIMP1) ratio were significantly higher in PKDL patients than in other groups. PKDL is frequent in Bangladesh and poses a challenge to the current visceral leishmaniasis elimination initiative in the Indian subcontinent.


Assuntos
Leishmaniose Cutânea/imunologia , Leishmaniose Cutânea/patologia , Leishmaniose Visceral/complicações , Adolescente , Adulto , Idoso , Antiprotozoários/uso terapêutico , Bangladesh/epidemiologia , Criança , Pré-Escolar , Colagenases/sangue , Citocinas/sangue , Feminino , Humanos , Incidência , Leishmaniose Cutânea/tratamento farmacológico , Leishmaniose Cutânea/epidemiologia , Leishmaniose Visceral/tratamento farmacológico , Leishmaniose Visceral/epidemiologia , Masculino , Inibidores de Metaloproteinases de Matriz/sangue , Pessoa de Meia-Idade , Fatores de Risco , Adulto Jovem
15.
Nanomedicine (Lond) ; 7(12): 1827-37, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22891866

RESUMO

AIM: The authors have investigated the usefulness of in vivo chemical exchange saturation transfer MRI for detecting gliomas using a dual-modality imaging contrast agent. MATERIALS & METHODS: A paramagnetic chemical exchange saturation transfer MRI contrast agent, Eu-1,4,7,10-tetraazacclododecane-1,4,7,10-tetraacetic acid-Gly(4) and a fluorescent agent, DyLight 680, were conjugated to a generation 5 polyamidoamine dendrimer to create the dual-modality, nano-sized imaging contrast agent. RESULTS: The agent was detected with in vivo chemical exchange saturation transfer MRI in an U87 glioma model. These results were validated using in vivo and ex vivo fluorescence imaging. CONCLUSION: This study demonstrated the merits of using a nano-sized imaging contrast agent for detecting gliomas and using a dual-modality agent for detecting gliomas at different spatial scales.


Assuntos
Meios de Contraste , Dendrímeros , Corantes Fluorescentes , Glioma/diagnóstico , Imageamento por Ressonância Magnética , Imagem Óptica , Poliaminas , Animais , Linhagem Celular Tumoral , Meios de Contraste/química , Dendrímeros/química , Corantes Fluorescentes/química , Humanos , Poliaminas/química , Ratos , Ratos Nus
16.
PLoS One ; 7(1): e30310, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22276177

RESUMO

BACKGROUND: Due to their unique property to migrate to pathological lesions, stem cells are used as a delivery vehicle for therapeutic genes to tumors, especially for glioma. It is critically important to track the movement, localization, engraftment efficiency and functional capability or expression of transgenes of selected cell populations following transplantation. The purposes of this study were to investigate whether 1) intravenously administered, genetically transformed cord blood derived EPCs can carry human sodium iodide symporter (hNIS) to the sites of tumors in rat orthotopic model of human glioma and express transgene products, and 2) whether accumulation of these administered EPCs can be tracked by different in vivo imaging modalities. METHODS AND RESULTS: Collected EPCs were cultured and transduced to carry hNIS. Cellular viability, differential capacity and Tc-99m uptake were determined. Five to ten million EPCs were intravenously administered and Tc-99-SPECT images were acquired on day 8, to determine the accumulation of EPCs and expression of transgenes (increase activity of Tc-99m) in the tumors. Immunohistochemistry was performed to determine endothelial cell markers and hNIS positive cells in the tumors. Transduced EPCs were also magnetically labeled and accumulation of cells was confirmed by MRI and histochemistry. SPECT analysis showed increased activity of Tc-99m in the tumors that received transduced EPCs, indicative of the expression of transgene (hNIS). Activity of Tc-99m in the tumors was also dependent on the number of administered transduced EPCs. MRI showed the accumulation of magnetically labeled EPCs. Immunohistochemical analysis showed iron and hNIS positive and, human CD31 and vWF positive cells in the tumors. CONCLUSION: EPC was able to carry and express hNIS in glioma following IV administration. SPECT detected migration of EPCs and expression of the hNIS gene. EPCs can be used as gene carrier/delivery system for glioma therapy as well as imaging probes.


Assuntos
Células Endoteliais/citologia , Glioma/metabolismo , Glioma/terapia , Células-Tronco/citologia , Células-Tronco/metabolismo , Antígeno AC133 , Animais , Antígenos CD/metabolismo , Antígenos CD34/metabolismo , Linhagem Celular Tumoral , Proliferação de Células , Sobrevivência Celular/genética , Sobrevivência Celular/fisiologia , Células Cultivadas , Modelos Animais de Doenças , Glioma/genética , Glicoproteínas/metabolismo , Humanos , Lentivirus/genética , Imageamento por Ressonância Magnética , Peptídeos/metabolismo , Ratos , Ratos Nus , Simportadores/genética , Simportadores/metabolismo
17.
Bioorg Med Chem ; 16(1): 437-45, 2008 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-17900911

RESUMO

Inhibitors of histone deacetylases (HDACs) are a promising class of anticancer agents that effect gene regulation. To know the interaction of aliphatic cap groups with HDACs, cyclic tetrapeptide and bicyclic peptide disulfide hybrids were synthesized without aromatic ring in their macrocyclic framework. Benzene ring of l-Phe in chlamydocin was replaced with several aliphatic amino acids and also a fused bicyclic tetrapeptide was synthesized by ring closing metathesis using Grubb's first generation catalyst. The inhibitory activities of the cyclic peptides against histone deacetylase enzymes were evaluated, which demonstrated most of them are interesting candidates as anticancer agents.


Assuntos
Inibidores de Histona Desacetilases , Peptídeos Cíclicos/síntese química , Peptídeos Cíclicos/farmacologia , Antineoplásicos/síntese química , Linhagem Celular , Inibidores Enzimáticos/síntese química , Inibidores Enzimáticos/farmacologia , Histona Desacetilase 1 , Desacetilase 6 de Histona , Histona Desacetilases , Humanos , Concentração Inibidora 50 , Proteínas Repressoras , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA