1.
J Assoc Res Otolaryngol ; 20(3): 291-303, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30911952

RESUMO

Cochlear implant (CI) programming is similar for all CI users despite limited understanding of the electrode-neuron interface (ENI). The ENI refers to the ability of each CI electrode to effectively stimulate target auditory neurons and is influenced by electrode position, neural health, cochlear geometry, and bone and tissue growth in the cochlea. Hearing history likely affects these variables, suggesting that the efficacy of each channel of stimulation differs between children who were implanted at young ages and adults who lost hearing and received a CI later in life. This study examined whether ENI quality differed between early-implanted children and late-implanted adults. Auditory detection thresholds and most comfortable levels (MCLs) were obtained with monopolar and focused electrode configurations. Channel-to-channel variability and dynamic range were calculated for both types of stimulation. Electrical field imaging data were also acquired to estimate levels of intracochlear resistance. Children exhibited lower average auditory perception thresholds and MCLs compared with adults, particularly with focused stimulation. However, neither dynamic range nor channel-to-channel threshold variability differed between groups, suggesting that children's range of perceptible current was shifted downward. Children also demonstrated increased intracochlear resistance levels relative to the adult group, possibly reflecting greater ossification or tissue growth after CI surgery. These results illustrate physical and perceptual differences related to the ENI of early-implanted children compared with late-implanted adults. Evidence from this study demonstrates a need for further investigation of the ENI in CI users with varying hearing histories.


Assuntos
Implante Coclear , Implantes Cocleares , Gânglio Espiral da Cóclea/fisiologia , Adolescente , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Humanos , Pessoa de Meia-Idade
2.
IEEE Trans Biomed Eng ; 60(6): 1685-92, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23358943

RESUMO

A vestibular neural prosthesis was designed on the basis of a cochlear implant for treatment of Meniere's disease and other vestibular disorders. Computer control software was developed to generate patterned pulse stimuli for exploring optimal parameters to activate the vestibular nerve. Two rhesus monkeys were implanted with the prototype vestibular prosthesis and they were behaviorally evaluated post implantation surgery. Horizontal and vertical eye movement responses to patterned electrical pulse stimulations were collected on both monkeys. Pulse amplitude modulated (PAM) and pulse rate modulated (PRM) trains were applied to the lateral canal of each implanted animal. Robust slow-phase nystagmus responses following the PAM or PRM modulation pattern were observed in both implanted monkeys in the direction consistent with the activation of the implanted canal. Both PAM and PRM pulse trains can elicit a significant amount of in-phase modulated eye velocity changes and they could potentially be used for efficiently coding head rotational signals in future vestibular neural prostheses.


Assuntos
Implantes Cocleares , Estimulação Elétrica/métodos , Implantes Experimentais , Processamento de Sinais Assistido por Computador/instrumentação , Animais , Eletrodos , Potenciais Evocados/fisiologia , Movimentos Oculares/fisiologia , Macaca mulatta , Desenho de Prótese , Vestíbulo do Labirinto/cirurgia
3.
Otol Neurotol ; 33(5): 789-96, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22699989

RESUMO

HYPOTHESIS: It is possible to implant a stimulating electrode array in the semicircular canals without damaging rotational sensitivity or hearing. The electrodes will evoke robust and precisely controlled eye movements. BACKGROUND: A number of groups are attempting to develop a neural prosthesis to ameliorate abnormal vestibular function. Animal studies demonstrate that electrodes near the canal ampullae can produce electrically evoked eye movements. The target condition of these studies is typically bilateral vestibular hypofunction. Such a device could potentially be more widely useful clinically and would have a simpler roadmap to regulatory approval if it produced minimal or no damage to the native vestibular and auditory systems. METHODS: An electrode array was designed for insertion into the bony semicircular canal adjacent to the membranous canal. It was designed to be sufficiently narrow so as to not compress the membranous canal. The arrays were manufactured by Cochlear, Ltd., and linked to a Nucleus Freedom receiver/stimulator. Seven behaviorally trained rhesus macaques had arrays placed in 2 semicircular canals using a transmastoid approach and "soft surgical" procedures borrowed from Hybrid cochlear implant surgery. Postoperative vestibulo-ocular reflex was measured in a rotary chair. Click-evoked auditory brainstem responses were also measured in the 7 animals using the contralateral ear as a control. RESULTS: All animals had minimal postoperative vestibular signs and were eating within hours of surgery. Of 6 animals tested, all had normal postoperative sinusoidal gain. Of 7 animals, 6 had symmetric postoperative velocity step responses toward and away from the implanted ear. The 1 animal with significantly asymmetric velocity step responses also had a significant sensorineural hearing loss. One control animal that underwent canal plugging had substantial loss of the velocity step response toward the canal-plugged ear. In 5 animals, intraoperative electrically evoked vestibular compound action potential recordings facilitated electrode placement. Postoperatively, electrically evoked eye movements were obtained from electrodes associated with an electrically evoked vestibular compound action potential wave form. Hearing was largely preserved in 6 animals and lost in 1 animal. CONCLUSION: It is possible to implant the vestibular system with prosthetic stimulating electrodes without loss of rotational sensitivity or hearing. Because electrically evoked eye movements can be reliably obtained with the assistance of intraoperative electrophysiology, it is appropriate to consider treatment of a variety of vestibular disorders using prosthetic electrical stimulation. Based on these findings, and others, a feasibility study for the treatment of human subjects with disabling Ménière's disease has begun.


Assuntos
Movimentos Oculares/fisiologia , Audição/fisiologia , Percepção de Movimento/fisiologia , Implantação de Prótese/métodos , Canais Semicirculares/cirurgia , Potenciais de Ação/fisiologia , Animais , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Testes Auditivos , Neuroestimuladores Implantáveis , Macaca mulatta , Reflexo Vestíbulo-Ocular/fisiologia , Rotação , Canais Semicirculares/fisiologia
4.
Hear Res ; 287(1-2): 51-6, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22504025

RESUMO

We measured auditory brainstem responses (ABRs) in eight Rhesus monkeys after implantation of electrodes in the semicircular canals of one ear, using a multi-channel vestibular prosthesis based on cochlear implant technology. In five animals, click-evoked ABR thresholds in the implanted ear were within 10 dB of thresholds in the non-implanted control ear. Threshold differences in the remaining three animals varied from 18 to 69 dB, indicating mild to severe hearing losses. Click- and tone-evoked ABRs measured in a subset of animals before and after implantation revealed a comparable pattern of threshold changes. Thresholds obtained five months or more after implantation--a period in which the prosthesis regularly delivered electrical stimulation to achieve functional activation of the vestibular system--improved in three animals with no or mild initial hearing loss and increased in a fourth with a moderate hearing loss. These results suggest that, although there is a risk of hearing loss with unilateral vestibular implantation to treat balance disorders, the surgery can be performed in a manner that preserves hearing over an extended period of functional stimulation.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Canais Semicirculares/inervação , Vestíbulo do Labirinto/inervação , Estimulação Acústica , Animais , Limiar Auditivo , Implante Coclear/efeitos adversos , Estimulação Elétrica , Eletroencefalografia , Potenciais Evocados Auditivos do Tronco Encefálico , Movimentos Oculares , Perda Auditiva/etiologia , Perda Auditiva/fisiopatologia , Macaca mulatta , Masculino , Desenho de Prótese , Tempo de Reação , Medição de Risco , Fatores de Tempo
5.
Otol Neurotol ; 32(1): 88-97, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21192375

RESUMO

OBJECTIVE: We recorded intraoperative and postoperative electrically evoked compound action potentials (ECAPs) in rhesus monkeys implanted with a vestibular neurostimulator. The objectives were to correlate the generation of slow-phase nystagmus or eye twitches induced by electrical stimulation of the implanted semicircular canal with the presence or absence of the vestibular ECAP responses and to assess the effectiveness of ECAP monitoring during surgery to guide surgical insertion of electrode arrays into the canals. DESIGN: Four rhesus monkeys (a total of 7 canals) were implanted with a vestibular neurostimulator modified from the Nucleus Freedom cochlear implant. ECAP recordings were obtained during surgery or at various intervals after surgery using the Neural Response Telemetry feature of the clinical Custom Sound EP software. Eye movements during electrical stimulation of individual canals were recorded with a scleral search coil system in the same animals. RESULTS: Measurable vestibular ECAPs were observed intraoperatively or postoperatively in 3 implanted animals. Robust and sustained ECAPs were obtained in 3 monkeys at the test intervals of 0, 7, or greater than 100 days after implantation surgery. In all 3 animals, stimulation with electrical pulse trains produced measurable eye movements in a direction consistent with the vestibulo-ocular reflex from the implanted semicircular canal. In contrast, electrically evoked eye movements could not be measured in 3 of the 7 implanted canals, none of which produced distinct vestibular ECAPs. In 2 animals, ECAP waveforms were systematically monitored during surgery, and the procedure proved crucial to the success of vestibular implantation. CONCLUSION: Vestibular ECAPs exhibit similar morphology and growth characteristics to cochlear ECAPs from human cochlear implant patients. The ECAP measure is well correlated with the functional activation of eye movements by electrical stimulation after implantation surgery. The intraoperative ECAP recording technique is an efficient tool to guide the placement of electrode array into the semicircular canals.


Assuntos
Potenciais de Ação/fisiologia , Potenciais Evocados/fisiologia , Nervo Vestibular/fisiologia , Animais , Estimulação Elétrica , Eletrodos Implantados , Macaca mulatta , Nistagmo Fisiológico/fisiologia , Reflexo Vestíbulo-Ocular/fisiologia
SELEÇÃO DE REFERÊNCIAS