Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Otolaryngol Head Neck Surg ; 166(4): 760-767, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34253111

RESUMO

OBJECTIVES: To evaluate the performance of 4-dimensional computed tomography (4D-CT) in assessing upper airway obstruction (UAO) in patients with Robin sequence (RS) and compare the accuracy and reliability of 4D-CT and flexible fiber-optic laryngoscopy (FFL). STUDY DESIGN: Prospective survey of retrospective clinical data. SETTING: Single, tertiary care pediatric hospital. METHODS: At initial and 30-day time points, a multidisciplinary group of 11 clinicians who treat RS rated UAO severity in 32 sets of 4D-CT visualizations and FFL videos (dynamic modalities) and static CT images. Raters assessed UAO at the velopharynx and oropharynx (1 = none to 5 = complete) and noted confidence levels of each rating. Intraclass correlation and Krippendorff alpha were used to assess intra- and interrater reliability, respectively. Accuracy was assessed by comparing clinician ratings with quantitative percentage constriction (QPC) ratings, calculated based on 4D-CT airway cross-sectional area. Results were compared using Wilcoxon rank-sum and signed-rank tests. RESULTS: There was similar intrarater agreement (moderate to substantial) with 4D-CT and FFL, and both demonstrated fair interrater agreement. Both modalities underestimated UAO severity, although 4D-CT ratings were significantly more accurate, as determined by QPC similarity, than FFL (-1.06 and -1.46 vs QPC ratings, P = .004). Overall confidence levels were similar for 4D-CT and FFL, but other specialists were significantly less confident in FFL ratings than were otolaryngologists (2.25 and 3.92, P < .0001). CONCLUSION: Although 4D-CT may be more accurate in assessing the degree of UAO in patients with RS, 4D-CT and FFL assessments demonstrate similar reliability. Additionally, 4D-CT may be interpreted with greater confidence by nonotolaryngologists who care for these patients.


Assuntos
Laringoscopia , Síndrome de Pierre Robin , Criança , Tomografia Computadorizada Quadridimensional , Humanos , Laringoscopia/métodos , Síndrome de Pierre Robin/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Otolaryngol Head Neck Surg ; 165(6): 905-908, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33689485

RESUMO

Thorough assessment of dynamic upper airway obstruction (UAO) in Robin sequence (RS) is critical, but traditional evaluation modalities have significant limitations. Four-dimensional computed tomography (4D-CT) is promising in that it enables objective and quantitative evaluation throughout all phases of respiration. However, there exist few protocols or analysis tools to assist in obtaining and interpreting the vast amounts of obtained data. A protocol and set of data analysis tools were developed to enable quantification and visualization of dynamic 4D-CT data. This methodology was applied to a sample case at 2 time points. In the patient with RS, overall increases in normalized airway caliber were observed from 5 weeks to 1 year. There was, however, continued dynamic obstruction at all airway levels, though objective measures of UAO did improve at the nasopharynx and oropharynx. Use of 4D-CT and novel analyses provide additional quantitative information to evaluate UAO in patients with RS.


Assuntos
Tomografia Computadorizada Quadridimensional , Faringe/diagnóstico por imagem , Síndrome de Pierre Robin/diagnóstico por imagem , Feminino , Humanos , Lactente , Cavidade Nasal/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA