Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomed Phys Eng Express ; 10(6)2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39214123

RESUMO

Objective. The apparent diffusion coefficient (ADC) extracted from diffusion-weighted magnetic resonance imaging (DWI) is a potential biomarker in radiotherapy (RT). DWI is often implemented with an echo-planar imaging (EPI) read-out due to speed, but unfortunately low geometric accuracy follows. This study aimed to investigate the influence of geometric distortions on the ADCs extracted from the gross tumor volume (GTV) and on the shape of the GTV in abdominal EPI-DWI.Approach. Twenty-one patients had EPI-DWI scans on a 1.5 T MRI sim before treatment and on a 1.5 T MRI-Linac at one of the first treatment fractions. Off-resonance correction with and without eddy current correction were applied to ADC maps. The clinical GTVs were deformed based on the same (but inverted) corrections to assess the local-regional geometric influence of distortions. Mean surface distance (MSD), Hausdorff distance (HD), and Dice similarity coefficient (DSC) were calculated to compare the original and distorted GTVs, and ADC values were calculated based on a mono-exponential model. Phantom measurements were performed to validate the applied correction method.Main results. The median (range) ADC change within the GTV after full distortion correction was 1.3% (0.02%-6.9%) for MRI-Sim and 1.5% (0.1%-6.4%) for MRI-Linac. The additional effect of the eddy current correction was small in both systems. The median (range) MSD, HD, and DSC comparing the original and off-resonance distorted GTVs for all patients were 0.43 mm (0.11-0.94 mm), 4.00 mm (1.00-7.81 mm) and 0.93 (0.82-0.99), respectively.Significance. Overall effect of distortion correction was small in terms of derived ADC values, indicating that distortion correction is unimportant for prediction of outcomes based on ADC. However, large local geometric changes occurred after off-resonance distortion correction for some patients, suggesting that if the spatial information from ADC maps is to be used for dose painting strategies, corrections should be applied.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Imagens de Fantasmas , Humanos , Imagem Ecoplanar/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Processamento de Imagem Assistida por Computador/métodos , Abdome/diagnóstico por imagem , Masculino , Neoplasias Abdominais/radioterapia , Neoplasias Abdominais/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Carga Tumoral , Algoritmos , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Front Oncol ; 14: 1401464, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39091912

RESUMO

Background and purpose: Biomarkers for prediction of outcome in patients with pancreatic cancer are wanted in order to personalize the treatment. This study investigated the value of longitudinal diffusion-weighted magnetic resonance imaging (DWI) for prediction of overall survival (OS) in patients with locally advanced pancreatic cancer (LAPC) treated with stereotactic body radiotherapy (SBRT). Materials and methods: The study included 45 patients with LAPC who received 5 fractions of 10 Gy on a 1.5T MRI-Linac. DWI was acquired prior to irradiation at each fraction. The analysis included baseline values and time-trends of the apparent diffusion coefficient (ADC) and DWI parameters obtained using a decomposition method. A multivariable Cox proportional hazards model for OS was made using best-subset selection, using cross-validation based on Bootstrap. Results: The median OS from the first day of SBRT was 15.5 months (95% CI: 13.2-20.6), and the median potential follow-up time was 19.8 months. The best-performing multivariable model for OS included two decomposition-based DWI parameters: one baseline and one time-trend parameter. The C-Harrell index describing the model's discriminating power was 0.754. High baseline ADC values were associated with reduced OS, whereas no association between the ADC time-trend and OS was observed. Conclusion: Decomposition-based DWI parameters indicated value in the prediction of OS in LAPC. A DWI time-trend parameter was included in the best-performing model, indicating a potential benefit of acquiring longitudinal DWI during the SBRT course. These findings support both baseline and longitudinal DWI as candidate prognostic biomarkers, which may become tools for personalization of the treatment of patients with LAPC.

3.
Radiother Oncol ; 186: 109803, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37437609

RESUMO

BACKGROUND AND PURPOSE: The apparent diffusion coefficient (ADC), a potential imaging biomarker for radiotherapy response, needs to be reproducible before translation into clinical use. The aim of this study was to evaluate the multi-centre delineation- and calculation-related ADC variation and give recommendations to minimize it. MATERIALS AND METHODS: Nine centres received identical diffusion-weighted and anatomical magnetic resonance images of different cancerous tumours (adrenal gland, pelvic oligo metastasis, pancreas, and prostate). All centres delineated the gross tumour volume (GTV), clinical target volume (CTV), and viable tumour volume (VTV), and calculated ADCs using both their local calculation methods and each of the following calculation conditions: b-values 0-500 vs. 150-500 s/mm2, region-of-interest (ROI)-based vs. voxel-based calculation, and mean vs. median. ADC variation was assessed using the mean coefficient of variation across delineations (CVD) and calculation methods (CVC). Absolute ADC differences between calculation conditions were evaluated using Friedman's test. Recommendations for ADC calculation were formulated based on observations and discussions within the Elekta MRI-linac consortium image analysis working group. RESULTS: The median (range) CVD and CVC were 0.06 (0.02-0.32) and 0.17 (0.08-0.26), respectively. The ADC estimates differed 18% between b-value sets and 4% between ROI/voxel-based calculation (p-values < 0.01). No significant difference was observed between mean and median (p = 0.64). Aligning calculation conditions between centres reduced CVC to 0.04 (0.01-0.16). CVD was comparable between ROI types. CONCLUSION: Overall, calculation methods had a larger impact on ADC reproducibility compared to delineation. Based on the results, significant sources of variation were identified, which should be considered when initiating new studies, in particular multi-centre investigations.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias , Masculino , Humanos , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA