Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Sci Rep ; 14(1): 4724, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413684

RESUMO

Photon-counting detector (PCD)-CT allows for reconstruction of virtual non-iodine (VNI) images from contrast-enhanced datasets. This study assesses the diagnostic performance of aortic valve calcification scoring (AVCS) derived from VNI datasets generated with a 1st generation clinical dual-source PCD-CT. AVCS was evaluated in 123 patients (statistical analysis only comprising patients with aortic valve calcifications [n = 56; 63.2 ± 11.6 years]), who underwent contrast enhanced electrocardiogram-gated (either prospective or retrospective or both) cardiac CT on a clinical PCD system. Patient data was reconstructed at 70 keV employing a VNI reconstruction algorithm. True non-contrast (TNC) scans at 70 keV without quantum iterative reconstruction served as reference in all individuals. Subgroup analysis was performed in 17 patients who received both, prospectively and retrospectively gated contrast enhanced scans (n = 8 with aortic valve calcifications). VNI images with prospective/retrospective gating had an overall sensitivity of 69.2%/56.0%, specificity of 100%/100%, accuracy of 85.4%/81.0%, positive predictive value of 100%/100%, and a negative predictive value of 78.2%/75.0%. VNI images with retrospective gating achieved similar results. For both gating approaches, AVCSVNI showed high correlation (r = 0.983, P < 0.001 for prospective; r = 0.986, P < 0.001 for retrospective) with AVCSTNC. Subgroup analyses demonstrated excellent intra-individual correlation between different acquisition modes (r = 0.986, P < 0.001). Thus, VNI images derived from cardiac PCD-CT allow for excellent diagnostic performance in the assessment of AVCS, suggesting potential for the omission of true non-contrast scans in the clinical workup of patients with aortic calcifications.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valva Aórtica/patologia , Calcinose , Iodo , Humanos , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia
2.
AJR Am J Roentgenol ; 222(2): e2330154, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37966036

RESUMO

BACKGROUND. Dual-energy CT pulmonary angiography (CTPA) with energy-integrating detector (EID) technology is limited by the inability to use high-pitch technique. OBJECTIVE. The purpose of this study was to compare the image quality of anatomic images and iodine maps between high-pitch photon-counting detector (PCD) CTPA and dual-energy EID CTPA. METHODS. This prospective study included 117 patients (70 men and 47 women; median age, 65 years) who underwent CTPA to evaluate for pulmonary embolism between March 2022 and November 2022. Fifty-eight patients were randomized to undergo PCD CTPA (pitch, 2.0), and 59 were randomized to undergo EID CTPA (pitch, 0.55). For each examination, 120-kV polychromatic images, 60-keV virtual monogenetic images (VMIs), and iodine maps were reconstructed. One radiologist measured CNR and SNR. Three radiologists independently assessed subjective image quality (on a scale of 1-4, with a score of 1 denoting highest quality). Radiation dose was recorded. RESULTS. SNR and CNR were higher for PCD CTPA than for EID CTPA for polychromatic images and VMIs, for all assessed vessels other than the left upper lobe artery. For example, for PCD CTPA versus EID CTPA, the right lower lobe artery on polychromatic images had an SNR of 34.5 versus 28.0 (p = .003) and a CNR of 29.2 versus 24.4 (p = .001), and on VMIs it had an SNR of 43.2 versus 32.7 (p = .005) and a CNR of 37.4 versus 29.3 (p = .002). For both scanners for readers 1 and 2, the median image quality score for polychromatic images and VMIs was 1, although distributions indicated significantly better scores for PCD CTPA than for EID CTPA for polychromatic images for reader 1 (p = .02) and reader 2 (p = .005) and for VMIs for reader 1 (p = .001) and reader 2 (p = .006). The image quality of anatomic image sets was not different between PCD CTPA and EID CTPA for reader 3 (p > .05). The image quality of iodine maps was not different between PCD CTPA and EID CTPA for any reader (p > .05). For PCD CTPA versus EID CTPA, the CTDIvol was 3.9 versus 4.5 mGy (p = .03), and the DLP was 123.5 mGy × cm versus 157.0 mGy × cm (p < .001). CONCLUSION. High-pitch PCD CTPA provided anatomic images with better subjective and objective image quality versus dual-energy EID CTPA, with lower radiation dose. Iodine maps showed no significant difference in image quality between scanners. CLINICAL IMPACT. CTPA may benefit from the PCD CT technique.


Assuntos
Iodo , Masculino , Humanos , Feminino , Idoso , Estudos Prospectivos , Fótons , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
3.
Am J Nucl Med Mol Imaging ; 13(5): 208-216, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023816

RESUMO

BACKGROUND: The aim of this study was to determine the read-out capabilities of the novel C-X-C motif chemokine receptor 4 (CXCR4)-targeting radiotracer [68Ga]Ga-PentixaFor compared to the reference radiotracer [18F]FDG in untreated individuals with head and neck squamous cell carcinoma (HNSCC). MATERIAL AND METHODS: 12 patients with histologically confirmed HNSCC were scheduled for [18F]FDG and [68Ga]Ga-PentixaFor PET/CT. Maximum standardized uptake values (SUVmax) and target-to-background ratios (TBR) were applied with vena cava superior serving as reference. In addition, we compared [68Ga]Ga-PentixaFor-PET findings with immunohistochemical (IHC) results of CXCR4 expression. RESULTS: On visual assessment, [18F]FDG identified more sites of disease, with increased detection rates for both the primary tumor ([18F]FDG, 12/12 [100%] vs. [68Ga]Ga-PentixaFor, 10/12 [83%]) and LN metastases ([18F]FDG, 9/12 [75%] vs. [68Ga]Ga-PentixaFor, 8/12 [67%]). Indicative for improved image contrast using [18F]FDG, quantification showed a higher TBR for the latter radiotracer, when compared to [68Ga]Ga-PentixaFor for all lesions ([18F]FDG, 11.7 ± 8.5 vs. [68Ga]Ga-PentixaFor, 4.3 ± 1.3; P=0.03), primary tumors ([18F]FDG, 13.6 ± 8.7 vs. [68Ga]Ga-PentixaFor, 4.4 ± 1.4; P<0.01), and LN lesions ([18F]FDG, 9.3 ± 10.6 vs. [68Ga]Ga-PentixaFor, 4.7 ± 1.5; P=0.3). IHC showed variable CXCR4 expression in the primary and LN, along with no associations between ex-vivo CXCR4 upregulation and [68Ga]Ga-PentixaFor-based TBR (R=0.33, P=0.39) or SUVmax (R=0.44, P=0.2). Of note, IHC also revealed heterogeneous expression of CXCR4 in immune cells in the tumor microenvironment and in germinal centers, indicative for inflammatory reactions. CONCLUSIONS: In HNSCC, [18F]FDG demonstrated superior diagnostic performance relative to [68Ga]Ga-PentixaFor, in particular for assessment of the primary. Based on the IHC analyses, these findings may be explained by CXCR4 upregulation not only by tumor but also by immune cells in the tumor microenvironment.

4.
Clin Nucl Med ; 48(11): 923-927, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37756444

RESUMO

BACKGROUND: Given their neuroendocrine origin, head and neck paragangliomas (HNPGLs) can be imaged with somatostatin receptor (SSTR)-directed PET/CT. We aimed to determine whether the in vivo PET signal can differentiate between varying HNPGL subtypes. PATIENTS AND METHODS: Fourteen patients with HNPGL received pretherapeutic SSTR-PET/CTs using 68 Ga-DOTATOC. Six (42.9%) patients had a jugular paraganglioma (PGL-J), 5 (35.7%) were diagnosed with carotid paraganglioma (PGL-Cs), and the remaining 3 patients (21.4%) had PGL-C with pathogenic SDHx germline variants (PGL-C-SDH). A visual and quantitative assessment of the primary tumor on SSTR-PET was performed, including SUV max and target-to-background ratio (TBR). Quantitative values were then compared between subgroups of patients affected with different HNPGL entities. RESULTS: On visual assessment, all primary HNPGLs could be identified on SSTR-PET/CT. Quantification of HNPGL revealed substantially elevated SUV max in PGL-J (101.7 ± 58.5) when compared with PGL-C-SDH (13.4 ± 5.6, P < 0.05), but not when compared with PGL-C (66.7 ± 27.3, P = 0.4; PGL-C vs PGL-C-SDH, P = 0.2). TBR of PGL-J (202.9 ± 82.2), however, further differentiated between PGL-C (95.7 ± 45.4, P < 0.05) and PGL-C-SDH (20.4 ± 12.2, P < 0.01; PGL-C vs PGL-C-SDH, P = 0.3). Moreover, whole-body readout revealed metastases in 2/3 (66.7%) of PGL-C-SDH patients, with a single SSTR-expressing skeletal lesion in one subject and bipulmonary lesions in the other patient. CONCLUSIONS: In patients with HNPGL, SSTR-PET/CT identified the primary and metastatic disease and provides substantially elevated TBR, indicating excellent image contrast. PET-based quantification can also differentiate between varying HNPGL subtypes.


Assuntos
Neoplasias de Cabeça e Pescoço , Paraganglioma Extrassuprarrenal , Paraganglioma , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Receptores de Somatostatina , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Paraganglioma Extrassuprarrenal/patologia , Paraganglioma/diagnóstico por imagem
5.
Cancers (Basel) ; 15(10)2023 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-37345187

RESUMO

OBJECTIVES: Positron emission tomography (PET) is currently considered the non-invasive reference standard for lymph node (N-)staging in lung cancer. However, not all patients can undergo this diagnostic procedure due to high costs, limited availability, and additional radiation exposure. The purpose of this study was to predict the PET result from traditional contrast-enhanced computed tomography (CT) and to test different feature extraction strategies. METHODS: In this study, 100 lung cancer patients underwent a contrast-enhanced 18F-fluorodeoxyglucose (FDG) PET/CT scan between August 2012 and December 2019. We trained machine learning models to predict FDG uptake in the subsequent PET scan. Model inputs were composed of (i) traditional "hand-crafted" radiomics features from the segmented lymph nodes, (ii) deep features derived from a pretrained EfficientNet-CNN, and (iii) a hybrid approach combining (i) and (ii). RESULTS: In total, 2734 lymph nodes [555 (20.3%) PET-positive] from 100 patients [49% female; mean age 65, SD: 14] with lung cancer (60% adenocarcinoma, 21% plate epithelial carcinoma, 8% small-cell lung cancer) were included in this study. The area under the receiver operating characteristic curve (AUC) ranged from 0.79 to 0.87, and the scaled Brier score (SBS) ranged from 16 to 36%. The random forest model (iii) yielded the best results [AUC 0.871 (0.865-0.878), SBS 35.8 (34.2-37.2)] and had significantly higher model performance than both approaches alone (AUC: p < 0.001, z = 8.8 and z = 22.4; SBS: p < 0.001, z = 11.4 and z = 26.6, against (i) and (ii), respectively). CONCLUSION: Both traditional radiomics features and transfer-learning deep radiomics features provide relevant and complementary information for non-invasive N-staging in lung cancer.

6.
J Nucl Med ; 64(8): 1272-1278, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37290794

RESUMO

In patients with prostate cancer scheduled for systemic treatment, being overweight is linked to prolonged overall survival (OS), whereas sarcopenia is associated with shorter OS. We investigated fat-related and body composition parameters in patients undergoing prostate-specific membrane antigen (PSMA)-directed radioligand therapy (RLT) to assess their predictive value for OS. Methods: Body mass index (BMI, in kg/m2) and CT-derived body composition parameters (total, subcutaneous, visceral fat area, and psoas muscle area at the L3-L4 level) were determined for 171 patients scheduled for PSMA-directed RLT. After normalization for stature, the psoas muscle index was used to define sarcopenia. Outcome analysis was performed using Kaplan-Meier curves and Cox regression including fat-related and other clinical parameters (Gleason score, C-reactive protein [CRP], lactate dehydrogenase [LDH], hemoglobin, and prostate-specific antigen levels). The Harrell C-index was used for goodness-of-fit analysis. Results: Sixty-five patients (38%) had sarcopenia, and 98 patients (57.3%) had increased BMI. Relative to the 8-mo OS in normal-weight men (BMI < 25), overweight men (25 ≥ BMI > 30) and obese men (BMI ≥ 30) achieved a longer OS of 14 mo (hazard ratio [HR], 0.63; 95% CI, 0.40-0.99; P = 0.03) and 13 mo (HR, 0.47; 95% CI, 0.29-0.77; P = 0.004), respectively. Sarcopenia showed no impact on OS (11 vs. 12 mo; HR, 1.4; 95% CI, 0.91-2.1; P = 0.09). Most of the body composition parameters were tightly linked to OS on univariable analyses, with the highest C-index for BMI. In multivariable analysis, a higher BMI (HR, 0.91; 95% CI, 0.86-0.97; P = 0.006), lower CRP (HR, 1.09; 95% CI, 1.03-1.14; P < 0.001), lower LDH (HR, 1.08; 95% CI, 1.03-1.14; P < 0.001), and longer interval between initial diagnosis and RLT (HR, 0.95; 95% CI, 0.91-0.99; P = 0.02) were significant predictors of OS. Conclusion: Increased fat reserves assessed by BMI, CRP, LDH, and interval between initial diagnosis and RLT, but not CT-derived body composition parameters, were relevant predictors for OS. As BMI can be altered, future research should investigate whether a high-calorie diet before or during PSMA RLT may improve OS.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Sarcopenia , Masculino , Humanos , Índice de Massa Corporal , Neoplasias de Próstata Resistentes à Castração/radioterapia , Neoplasias de Próstata Resistentes à Castração/complicações , Sarcopenia/induzido quimicamente , Sarcopenia/complicações , Sarcopenia/tratamento farmacológico , Antígeno Prostático Específico/metabolismo , Sobrepeso/induzido quimicamente , Sobrepeso/complicações , Sobrepeso/tratamento farmacológico , Próstata/metabolismo , Resultado do Tratamento , Lutécio/uso terapêutico , Estudos Retrospectivos , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Dipeptídeos/uso terapêutico
7.
Eur Radiol ; 33(11): 7830-7839, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37311805

RESUMO

OBJECTIVE: To evaluate the image quality of an ultra-low contrast medium and radiation dose CT pulmonary angiography (CTPA) protocol for the diagnosis of acute pulmonary embolism using a clinical photon-counting detector (PCD) CT system and compare its performance to a dual-energy-(DE)-CTPA protocol on a conventional energy-integrating detector (EID) CT system. METHODS: Sixty-four patients either underwent CTPA with the novel scan protocol on the PCD-CT scanner (32 patients, 25 mL, CTDIvol 2.5 mGy·cm) or conventional DE-CTPA on a third-generation dual-source EID-CT (32 patients, 50 mL, CTDIvol 5.1 mGy·cm). Pulmonary artery CT attenuation, signal-to-noise ratio, and contrast-to-noise-ratio were assessed as objective criteria of image quality, while subjective ratings of four radiologists were compared at 60 keV using virtual monoenergetic imaging and polychromatic standard reconstructions. Interrater reliability was determined by means of the intraclass correlation coefficient (ICC). Effective dose was compared between patient cohorts. RESULTS: Subjective image quality was deemed superior by all four reviewers for 60-keV PCD scans (excellent or good ratings in 93.8% of PCD vs. 84.4% of 60 keV EID scans, ICC = 0.72). No examinations on either system were considered "non-diagnostic." Objective image quality parameters were significantly higher in the EID group (mostly p < 0.001), both in the polychromatic reconstructions and at 60 keV. The ED (1.4 vs. 3.3 mSv) was significantly lower in the PCD cohort (p < 0.001). CONCLUSIONS: PCD-CTPA allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism, while maintaining good to excellent image quality compared to conventional EID-CTPA. CLINICAL RELEVANCE STATEMENT: Clinical PCD-CT allows for spectral assessment of pulmonary vasculature with high scan speed, which is beneficial in patients with suspected pulmonary embolism, frequently presenting with dyspnea. Simultaneously PCD-CT enables substantial reduction of contrast medium and radiation dose. KEY POINTS: • The clinical photon-counting detector CT scanner used in this study allows for high-pitch multi-energy acquisitions. • Photon-counting computed tomography allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism. • Subjective image quality was rated best for 60-keV photon-counting scans.


Assuntos
Redução da Medicação , Embolia Pulmonar , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Embolia Pulmonar/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Fótons , Imagens de Fantasmas
8.
Eur Radiol ; 33(11): 7913-7922, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37256352

RESUMO

OBJECTIVES: We conducted a systematic review and individual participant data meta-analysis of publications reporting the ophthalmologic presentation, clinical exam, and orbital MRI findings in patients with giant cell arteritis and ocular manifestations. METHODS: PubMed and Cochrane databases were searched up to January 16, 2022. Publications reporting patient-level data on patients with ophthalmologic symptoms, imaged with orbital MRI, and diagnosed with biopsy-proven giant cell arteritis were included. Demographics, clinical symptoms, exam, lab, imaging, and outcomes data were extracted. The methodological quality and completeness of reporting of case reports were assessed. RESULTS: Thirty-two studies were included comprising 51 patients (females = 24; median age, 76 years). Vision loss (78%) and headache (45%) were commonly reported visual and cranial symptoms. Ophthalmologic presentation was unilateral (41%) or bilateral (59%). Fundus examination most commonly showed disc edema (64%) and pallor (49%). Average visual acuity was very poor (2.28 logMAR ± 2.18). Diagnoses included anterior (61%) and posterior (16%) ischemic optic neuropathy, central retinal artery occlusion (8%), and orbital infarction syndrome (2%). On MRI, enhancement of the optic nerve sheath (53%), intraconal fat (25%), and optic nerve/chiasm (14%) was most prevalent. Among patients with monocular visual symptoms, 38% showed pathologic enhancement in the asymptomatic orbit. Six of seven cases reported imaging resolution after treatment on follow-up MRIs. CONCLUSIONS: Vision loss, pallid disc edema, and optic nerve sheath enhancement are the most common clinical, fundoscopic, and imaging findings reported in patients diagnosed with giant cell arteritis with ocular manifestations, respectively. MRI may detect subclinical inflammation and ischemia in the asymptomatic eye and may be an adjunct diagnostic tool. CLINICAL RELEVANCE STATEMENT: Brain and orbital MRIs may have diagnostic and prognostic roles in patients with suspected giant cell arteritis who present with ophthalmic symptoms.


Assuntos
Arterite de Células Gigantes , Neuropatia Óptica Isquêmica , Feminino , Humanos , Idoso , Arterite de Células Gigantes/complicações , Arterite de Células Gigantes/diagnóstico por imagem , Transtornos da Visão , Imageamento por Ressonância Magnética/métodos , Neuropatia Óptica Isquêmica/diagnóstico , Neuropatia Óptica Isquêmica/etiologia , Edema/complicações
9.
Acad Radiol ; 30(7): 1358-1366, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36167629

RESUMO

OBJECTIVES: Gantry-free cone-beam CT (CBCT) allows for comfortable patient positioning due to an open scanner architecture. Since CBCT without gantry is not yet established for clinical wrist trauma imaging, this study's aim was to investigate its diagnostic value in the preoperative workup of patients with distal radius and scaphoid fractures. METHODS: Within a 12-month period, 113 patients with severe wrist trauma underwent both radiography and CBCT with the same gantry-free multi-use scanner before surgery. Two radiologists retrospectively analyzed all datasets for the morphology of distal radius (n = 95) and scaphoid fractures (n = 20). In all 115 wrists (two bilateral injuries), surgical reports served as the standard of reference. RESULTS: While accuracy for distal radius fractures was comparable among CBCT and radiographs, the former was superior with regard to scaphoid fractures (Reader 1: 100.0% vs. 75.0%; Reader 2: 100.0% vs. 65.0%). Accuracy for multi-fragmentary radius injuries (100.0% vs. 90.5%; 100.0% vs. 93.7%), and articular affliction (99.0% vs. 84.2%; 100.0% vs. 83.2%) was also higher in CBCT. Regarding scaphoid fractures, CBCT proved superior for diagnosis of proximal pole or waist involvement (100.0% vs. 70.0%; 100.0% vs. 65.0%) and comminuted patterns (100.0% vs. 70.0%; 100.0% vs. 75.0%). Median effective dose of CBCT was as low as 3.65 µSv compared with 0.16 µSv for standard radiography. CONCLUSION: Gantry-free CBCT allows for excellent diagnostic accuracy in the assessment of distal radius and scaphoid fracture morphology. Even in patients with limited mobility, very low radiation dose is sufficient to maintain high image quality.


Assuntos
Fraturas Ósseas , Osso Escafoide , Humanos , Fraturas Ósseas/diagnóstico por imagem , Rádio (Anatomia) , Estudos Retrospectivos , Osso Escafoide/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico
10.
Cancers (Basel) ; 14(2)2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35053434

RESUMO

Prostate-specific membrane antigen (PSMA)-directed positron emission tomography/computed tomography (PET/CT) is increasingly utilized for staging of men with prostate cancer (PC). To increase interpretive certainty, the standardized PSMA reporting and data system (RADS) has been proposed. Using PSMA-RADS, we characterized lesions in 18 patients imaged with 18F-PSMA-1007 PET/CT for primary staging and determined the stability of semi-quantitative parameters. Six hundred twenty-three lesions were categorized according to PSMA-RADS and manually segmented. In this context, PSMA-RADS-3A (soft-tissue) or -3B (bone) lesions are defined as being indeterminate for the presence of PC. For PMSA-RADS-4 and -5 lesions; however, PC is highly likely or almost certainly present [with further distinction based on absence (PSMA-RADS-4) or presence (PSMA-RADS-5) of correlative findings on CT]. Standardized uptake values (SUVmax, SUVpeak, SUVmean) were recorded, and volumetric parameters [PSMA-derived tumor volume (PSMA-TV); total lesion PSMA (TL-PSMA)] were determined using different maximum intensity thresholds (MIT) (40 vs. 45 vs. 50%). SUVmax was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories (p ≤ 0.0322). In particular, the clinically challenging PSMA-RADS-3A lesions showed significantly lower SUVmax and SUVpeak compared to the entire PSMA-RADS-4 or -5 cohort (p < 0.0001), while for PSMA-RADS-3B this only applies when compared to the entire PSMA-RADS-5 cohort (p < 0.0001), but not to the PSMA-RADS-4 cohort (SUVmax, p = 0.07; SUVpeak, p = 0.08). SUVmean (p = 0.30) and TL-PSMA (p = 0.16) in PSMA-RADS-5 lesions were not influenced by changing the MIT, while PSMA-TV showed significant differences when comparing 40 vs. 50% MIT (p = 0.0066), which was driven by lymph nodes (p = 0.0239), but not bone lesions (p = 0.15). SUVmax was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories in 18F-PSMA-1007 PET/CT. As such, the latter parameter may assist the interpreting molecular imaging specialist in assigning the correct PSMA-RADS score to sites of disease, thereby increasing diagnostic certainty. In addition, changes of the MIT in PSMA-RADS-5 lesions had no significant impact on SUVmean and TL-PSMA in contrast to PSMA-TV.

11.
Quant Imaging Med Surg ; 11(5): 1817-1827, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33936967

RESUMO

BACKGROUND: Computed tomography (CT) pulmonary angiography is the diagnostic reference standard in suspected pulmonary embolism (PE). Favorable results for dual-energy CT (DECT) images have been reported for this condition. Nowadays, dual-energy data acquisition is feasible with different technical options, including a single-source split-filter approach. Therefore, the aim of this retrospective study was to investigate image quality and radiation dose of thoracic split-filter DECT in comparison to conventional single-energy CT in patients with suspected PE. METHODS: A total of 110 CT pulmonary angiographies were accomplished either as standard single-energy CT with automatic tube voltage selection (ATVS) (n=58), or as split-filter DECT (n=52). Objective [pulmonary artery CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] and subjective image quality [four-point Likert scale; three readers (R)] were compared among the two study groups. Size-specific dose estimates (SSDE), dose-length-product (DLP) and volume CT dose index (CTDIvol) were assessed for radiation dose analysis. RESULTS: Split-filter DECT images yielded 67.7% higher SNR (27.0 vs. 16.1; P<0.001) and 61.9% higher CNR (22.5 vs. 13.9; P<0.001) over conventional single-energy images, whereas CT attenuation was significantly lower (344.5 vs. 428.2 HU; P=0.013). Subjective image quality was rated good or excellent in 93.0%/98.3%/77.6% (R1/R2/R3) of the single-energy CT scans, and 84.6%/82.7%/80.8% (R1/R2/R3) of the split-filter DECT scans. SSDE, DLP and CTDIvol were significantly lower for conventional single-energy CT compared to split-filter DECT (all P<0.05), which was associated with 26.7% higher SSDE. CONCLUSIONS: In the diagnostic workup of acute PE, the split-filter allows for dual-energy data acquisition from single-source single-layer CT scanners. The existing opportunity to assess pulmonary "perfusion" based on analysis of iodine distribution maps is associated with higher radiation dose in terms of increased SSDE than conventional single-energy CT with ATVS. Moreover, a proportion of up to 3.8% non-diagnostic examinations in the current reference standard test for PE is not negligible.

12.
BMC Med Imaging ; 21(1): 79, 2021 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-33964892

RESUMO

BACKGROUND: Functional lung MRI techniques are usually associated with time-consuming post-processing, where manual lung segmentation represents the most cumbersome part. The aim of this study was to investigate whether deep learning-based segmentation of lung images which were scanned by a fast UTE sequence exploiting the stack-of-spirals trajectory can provide sufficiently good accuracy for the calculation of functional parameters. METHODS: In this study, lung images were acquired in 20 patients suffering from cystic fibrosis (CF) and 33 healthy volunteers, by a fast UTE sequence with a stack-of-spirals trajectory and a minimum echo-time of 0.05 ms. A convolutional neural network was then trained for semantic lung segmentation using 17,713 2D coronal slices, each paired with a label obtained from manual segmentation. Subsequently, the network was applied to 4920 independent 2D test images and results were compared to a manual segmentation using the Sørensen-Dice similarity coefficient (DSC) and the Hausdorff distance (HD). Obtained lung volumes and fractional ventilation values calculated from both segmentations were compared using Pearson's correlation coefficient and Bland Altman analysis. To investigate generalizability to patients outside the CF collective, in particular to those exhibiting larger consolidations inside the lung, the network was additionally applied to UTE images from four patients with pneumonia and one with lung cancer. RESULTS: The overall DSC for lung tissue was 0.967 ± 0.076 (mean ± standard deviation) and HD was 4.1 ± 4.4 mm. Lung volumes derived from manual and deep learning based segmentations as well as values for fractional ventilation exhibited a high overall correlation (Pearson's correlation coefficent = 0.99 and 1.00). For the additional cohort with unseen pathologies / consolidations, mean DSC was 0.930 ± 0.083, HD = 12.9 ± 16.2 mm and the mean difference in lung volume was 0.032 ± 0.048 L. CONCLUSIONS: Deep learning-based image segmentation in stack-of-spirals based lung MRI allows for accurate estimation of lung volumes and fractional ventilation values and promises to replace the time-consuming step of manual image segmentation in the future.


Assuntos
Fibrose Cística/diagnóstico por imagem , Aprendizado Profundo , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos de Casos e Controles , Fibrose Cística/fisiopatologia , Humanos , Pulmão/fisiologia , Neoplasias Pulmonares/diagnóstico por imagem , Redes Neurais de Computação , Pneumonia/diagnóstico por imagem , Respiração
13.
BMC Cardiovasc Disord ; 21(1): 237, 2021 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980159

RESUMO

BACKGROUND: The effect of smoking on coronary vasomotion has been investigated in the past with various imaging techniques in both short- and long-term smokers. Additionally, coronary vasomotion has been shown to be normalized in long-term smokers by L-Arginine acting as a substrate for NO synthase, revealing the coronary endothelium as the major site of abnormal vasomotor response. Aim of the prospective cohort study was to investigate coronary vasomotion of young healthy short-term smokers via magnetic resonance cold pressor test with and without the administration of L-Arginine and compare obtained results with the ones from nonsmokers. METHODS: Myocardial blood flow (MBF) was quantified with first-pass perfusion MRI on a 1.5 T scanner in healthy short-term smokers (N = 10, age: 25.0 ± 2.8 years, 5.0 ± 2.9 pack years) and nonsmokers (N = 10, age: 34.3 ± 13.6) both at rest and during cold pressor test (CPT). Smokers underwent an additional examination after administration of L-Arginine within a median of 7 days of the naïve examination. RESULTS: MBF at rest turned out to be 0.77 ± 0.30 (smokers with no L-Arginine; mean ± standard deviation), 0.66 ± 0.21 (smokers L-Arginine) and 0.84 ± 0.08 (nonsmokers). Values under CPT were 1.21 ± 0.42 (smokers no L-Arginine), 1.09 ± 0.35 (smokers L-Arginine) and 1.63 ± 0.33 (nonsmokers). In all groups, MBF was significantly increased under CPT compared to the corresponding rest examination (p < 0.05 in all cases). Additionally, MBF under CPT was significantly different between the smokers and the nonsmokers (p = 0.002). MBF at rest was significantly different between the smokers when L-Arginine was given and the nonsmokers (p = 0.035). CONCLUSION: Short-term smokers showed a reduced response to cold both with and without the administration of L-Arginine. However, absolute MBF values under CPT were lower compared to nonsmokers independently of L-Arginine administration.


Assuntos
Arginina/administração & dosagem , Temperatura Baixa , Vasos Coronários/efeitos dos fármacos , Endotélio Vascular/efeitos dos fármacos , Imageamento por Ressonância Magnética , Fumantes , Fumar/efeitos adversos , Adulto , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Endotélio Vascular/diagnóstico por imagem , Endotélio Vascular/fisiopatologia , Ex-Fumantes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Fumar/fisiopatologia , Vasoconstrição/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Adulto Jovem
14.
JAMA Netw Open ; 4(4): e217083, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33881529

RESUMO

Importance: Squamous cell carcinoma (SCC) of the oral cavity is one of the most common tumor entities worldwide. Precise initial staging is necessary to determine a diagnosis, treatment, and prognosis. Objective: To examine the diagnostic accuracy of preoperative 18-F fluorodeoxyglucose (FDG) positron emission tomographic/computed tomographic (PET/CT) imaging in detecting cervical lymph node metastases. Design, Setting, and Participants: This prospective diagnostic study was performed at a single tertiary reference center between June 1, 2013, and January 31, 2016. Data were analyzed from April 7, 2018, through May 31, 2019. Observers of the FDG PET/CT imaging were blinded to patients' tumor stage. A total of 150 treatment-naive patients with clinical suspicion of SCC of the oral cavity were enrolled. Exposures: All patients underwent FDG PET/CT imaging before local tumor resection with selective or complete neck dissection. Main Outcomes and Measures: The accuracy of FDG PET/CT in localizing primary tumor, lymph node, and distant metastases was tested. Histopathologic characteristics of the tissue samples served as the standard of reference. Results: Of the 150 patients enrolled, 135 patients (74 [54.8%] men) with a median age of 63 years (range, 23-88 years) met the inclusion criteria (histopathologically confirmed primary SCC of the oral cavity/level-based histopathologic assessment of the resected lymph nodes). Thirty-six patients (26.7%) in the study cohort had neck metastases. Use of FDG PET/CT detected cervical lymph node metastasis with 83.3% sensitivity (95% CI, 71.2%-95.5%) and 84.8% specificity (95% CI, 77.8%-91.9%) and had a negative predictive value of 93.3% (95% CI, 88.2%-98.5%). The specificity was higher than for contrast-enhanced cervical CT imaging (67.0%; 95% CI, 57.4%-76.7%; P < .01) and cervical magnetic resonance imaging (62.6%; 95% CI, 52.7%-72.6%; P < .001). Ipsilateral lymph node metastasis in left- or right-sided primary tumor sites was detected with 78.6% sensitivity (95% CI, 63.4%-93.8%) and 83.1% specificity (95% CI, 75.1%-91.2%), and contralateral metastatic involvement was detected with 66.7% sensitivity (95% CI, 28.9%-100.0%) and 98.6% specificity (95% CI, 95.9%-100.0%). No distant metastases were observed. Conclusions and Relevance: In this study, FDG PET/CT imaging had a high negative predictive value in detecting cervical lymph node metastasis in patients with newly diagnosed, treatment-naive SCC of the oral cavity. Routine clinical use of FDG PET/CT might lead to a substantial reduction of treatment-related morbidity in most patients.


Assuntos
Linfonodos/diagnóstico por imagem , Neoplasias Bucais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Linfonodos/patologia , Metástase Linfática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Boca , Neoplasias Bucais/patologia , Pescoço/diagnóstico por imagem , Esvaziamento Cervical , Estadiamento de Neoplasias , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Adulto Jovem
16.
J Thorac Imaging ; 36(1): 43-51, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32453280

RESUMO

PURPOSE: Ultrashort echotime (UTE) sequences aim to improve the signal yield in pulmonary magnetic resonance imaging (MRI). We demonstrate the initial results of spiral 3-dimensional (3D) UTE-MRI for combined morphologic and functional imaging in pediatric patients. METHODS: Seven pediatric patients with pulmonary abnormalities were included in this observational, prospective, single-center study, with the patients having the following conditions: cystic fibrosis (CF) with middle lobe atelectasis, CF with allergic bronchopulmonary aspergillosis, primary ciliary dyskinesia, air trapping, congenital lobar overinflation, congenital pulmonary airway malformation, and pulmonary hamartoma.Patients were scanned during breath-hold in 5 breathing states on a 3-Tesla system using a prototypical 3D stack-of-spirals UTE sequence. Ventilation maps and signal intensity maps were calculated. Morphologic images, ventilation-weighted maps, and signal intensity maps of the lungs of each patient were assessed intraindividually and compared with reference examinations. RESULTS: With a scan time of ∼15 seconds per breathing state, 3D UTE-MRI allowed for sufficient imaging of both "plus" pathologies (atelectasis, inflammatory consolidation, and pulmonary hamartoma) and "minus" pathologies (congenital lobar overinflation, congenital pulmonary airway malformation, and air trapping). Color-coded maps of normalized signal intensity and ventilation increased diagnostic confidence, particularly with regard to "minus" pathologies. UTE-MRI detected new atelectasis in an asymptomatic CF patient, allowing for rapid and successful therapy initiation, and it was able to reproduce atelectasis and hamartoma known from multidetector computed tomography and to monitor a patient with allergic bronchopulmonary aspergillosis. CONCLUSION: 3D UTE-MRI using a stack-of-spirals trajectory enables combined morphologic and functional imaging of the lungs within ~115 second acquisition time and might be suitable for monitoring a wide spectrum of pulmonary diseases.


Assuntos
Imageamento Tridimensional , Neoplasias Pulmonares , Criança , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos
17.
Magn Reson Med ; 84(6): 3223-3233, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32767457

RESUMO

PURPOSE: The aim of this study was to compare the wave-CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free-breathing 4D lung MRI. METHODS: The wave-CAIPI k-space trajectory was implemented in a respiratory self-gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave-CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study. RESULTS: The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave-CAIPI approach. Average normalized mutual information values of the wave-CAIPI acquisitions were 10% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave-CAIPI technique was lower by 19% and the SNR was higher by 14%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave-CAIPI. CONCLUSION: The application of the wave-CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave-CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Estudos Retrospectivos
18.
Radiology ; 296(1): 191-199, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32343212

RESUMO

Background In cystic fibrosis (CF), recurrent imaging and pulmonary function tests (PFTs) are needed for the assessment of lung function during disease management. Purpose To assess the clinical feasibility of pulmonary three-dimensional ultrashort echo time (UTE) MRI at breath holding for quantitative image analysis of ventilation inhomogeneity and hyperinflation in CF compared with PFT. Materials and Methods In this prospective study from May 2018 to June 2019, participants with CF and healthy control participants underwent PFTs and functional lung MRI by using a prototypical single breath-hold three-dimensional UTE sequence. Fractional ventilation (FV) was calculated from acquired data in normal inspiration and normal expiration. FV of each voxel was normalized to the whole lung mean (FVN), and interquartile range of normalized ventilation (IQRN; as a measure of ventilation heterogeneity) was calculated. UTE signal intensity (SI) was assessed in full expiration (SIN, normalized to aortic blood). Obtained metrics were compared between participants with CF and control participants. For participants with CF, MRI metrics were correlated with the standard lung clearance index (LCI) and PFT. Mann-Whitney U tests and Spearman correlation were used for statistical analysis. Results Twenty participants with CF (mean age, 17 years ± 9 [standard deviation]; 12 men) and 10 healthy control participants (24 years ± 8; five men) were included. IQRN was higher for participants with CF than for control participants (mean, 0.66 ± 0.16 vs 0.50 ± 0.04, respectively; P = .007). In the 20 participants with CF, IQRN correlated with obstruction markers forced expiratory volume in 1 second-to-forced vital capacity ratio (r = -0.70; 95% confidence interval [CI]: -0.92, -0.28; P < .001), mean expiratory flow 25% (r = 0.78; 95% CI: -0.95, -0.39; P < .001), and with the ventilation inhomogeneity parameter LCI (r = 0.90; 95% CI: 0.69, 0.96; P < .001). Mean SIN in full expiration was lower in participants with CF than in control participants (0.34 ± 0.08 vs 0.39 ± 0.03, respectively; P = .03). Conclusion Three-dimensional ultrashort echo time MRI in the lungs allowed for functional imaging of ventilation inhomogeneity within a few breath holds in patients with cystic fibrosis. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Wielpütz in this issue.


Assuntos
Fibrose Cística/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Estudos de Viabilidade , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Estudos Prospectivos
19.
AJR Am J Roentgenol ; 214(2): 422-427, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31799871

RESUMO

OBJECTIVE. The purpose of this study was to assess image quality and radiation dose of a novel twin robotic x-ray system's 3D cone-beam CT (CBCT) function for the depiction of cadaveric wrists. MATERIALS AND METHODS. Sixteen cadaveric wrists were scanned using dedicated low-dose and standard-dose CBCT protocols as well as clinical MDCT for comparison. Three readers assessed overall image quality, noise, and artifacts in bone and soft tissue on 5-point Likert scales. For radiation dose analysis, volume CT dose indexes (CTDIvol) were compared. RESULTS. Overall image quality of most studies was very good or excellent in MDCT (for readers 1, 2, and 3: 100%, 100%, and 88%, respectively), standard-dose CBCT (100%, 100%, and 94%), and low dose CBCT (100%, 94%, and 88%) with two readers favoring standard-dose CBCT over MDCT image quality (readers 1 and 2; p ≤ 0.046). In soft tissue, standard-dose (readers 1, 2, and 3; p ≤ 0.021) and low-dose (all p ≤ 0.001) CBCT images had more noise than MDCT in all cases. Standard-dose (all p ≤ 0.003) and low-dose (all p < 0.001) CBCT images also displayed more artifacts. In osseous tissue, one reader observed more noise (p < 0.001) and artifacts (p = 0.020) for low-dose CBCT than for MDCT, whereas no difference was found between standard-dose CBCT and MDCT. Mean CTDIvol was significantly lower for standard-dose (5.2 ± 0.6 mGy; p < 0.001) and low-dose CBCT (1.8 ± 0.2 mGy; p < 0.001) than for clinical MDCT without automatic dose modulation (15.0 ± 0.0 mGy). CONCLUSION. The tested CBCT function delivers suitable image quality for clinical wrist imaging at significantly lower radiation levels than conventional MDCT. In combination with comfortable positioning options and the ability to perform additional radiographic and fluoroscopic examinations, the twin robotic x-ray system may hold the potential to be a one-stop shop device for trauma-associated wrist imaging.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Doses de Radiação , Robótica , Articulação do Punho/diagnóstico por imagem , Artefatos , Cadáver , Humanos , Posicionamento do Paciente
20.
Ann Rheum Dis ; 77(5): 636-643, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29358285

RESUMO

To develop evidence-based recommendations for the use of imaging modalities in primary large vessel vasculitis (LVV) including giant cell arteritis (GCA) and Takayasu arteritis (TAK). European League Against Rheumatism (EULAR) standardised operating procedures were followed. A systematic literature review was conducted to retrieve data on the role of imaging modalities including ultrasound, MRI, CT and [18F]-fluorodeoxyglucose positron emission tomography (PET) in LVV. Based on evidence and expert opinion, the task force consisting of 20 physicians, healthcare professionals and patients from 10 EULAR countries developed recommendations, with consensus obtained through voting. The final level of agreement was voted anonymously. A total of 12 recommendations have been formulated. The task force recommends an early imaging test in patients with suspected LVV, with ultrasound and MRI being the first choices in GCA and TAK, respectively. CT or PET may be used alternatively. In case the diagnosis is still in question after clinical examination and imaging, additional investigations including temporal artery biopsy and/or additional imaging are required. In patients with a suspected flare, imaging might help to better assess disease activity. The frequency and choice of imaging modalities for long-term monitoring of structural damage remains an individual decision; close monitoring for aortic aneurysms should be conducted in patients at risk for this complication. All imaging should be performed by a trained specialist using appropriate operational procedures and settings. These are the first EULAR recommendations providing up-to-date guidance for the role of imaging in the diagnosis and monitoring of patients with (suspected) LVV.


Assuntos
Arterite de Células Gigantes/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Reumatologia/normas , Arterite de Takayasu/diagnóstico por imagem , Ultrassonografia/normas , Vasculite/diagnóstico por imagem , Europa (Continente) , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/normas , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA