Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Pediatr Rep ; 16(1): 190-200, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38535513

RESUMO

PURPOSE: To compare suprapubic access (SPA) and transurethral catheterization (TUC) in voiding cystourethrogram (VCUG). METHODS: Retrospective single-center evaluation of 311 VCUG performed in male patients under 12 years of age. Two study groups were built based on the bladder access method. TUC was performed in 213 patients, whereas 98 received SPA. The groups were compared regarding the procedural switch rate, the complication rate, radiation parameters, the amount of contrast media applied and the examination quality. Complications were graded in minor (contrast leakage, premature termination of the examination) and major (fever, urinary tract infection, bladder perforation). Fluoroscopy time and radiation parameters were compared. Examination quality was assessed based on the satisfactory acquisition of fluoroscopic images using a four-point Likert scale. RESULTS: In 9% of the SPA examinations a method switch to TUC was necessary. The minor complication rate was 1.9% for TUC and 35.7% for SPA (p < 0.001). The major complication rate was 0.9% for TUC and 2% for SPA (p > 0.05). Mean fluoroscopy time and radiation dose were significantly lower in TUC (TUC, 26 ± 19 s, 0.6 ± 1.2 µGy·m2; SPA, 38 ± 33 s, 1.7 ± 2.9 µGy·m2; p = 0.01/0.001). There was no significant difference regarding the amount of contrast media applied (TUC, 62 ± 40 mL; SPA, 66 ± 41 mL; p > 0.05) and the examination quality with full diagnostic quality achieved in 88% of TUC and 89% of SPA examinations (p > 0.05). CONCLUSIONS: As TUC provides significantly lower radiation exposure and less periprocedural complications, it should be the primary bladder access route for VCUG in pediatric male patients.

2.
Cancers (Basel) ; 16(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38539562

RESUMO

This study investigated whether virtual monoenergetic images (VMIs) and iodine mapping based on dual-energy CT (DECT) provide advantages in the assessment of endometrial cancer. A dual-source DECT was performed for primary staging of histologically proven endometrioid adenocarcinoma in 21 women (66.8 ± 12.0 years). In addition to iodine maps, VMIs at 40, 50, 60, 70, and 80 keV were reconstructed from polyenergetic images (PEIs). Objective analysis comprised the measurement of tumor contrast, contrast-to-noise ratio, and normalized iodine concentration (NIC). In addition, three radiologists independently rated tumor conspicuity. The highest tumor contrast (106.6 ± 45.0 HU) and contrast-to-noise ratio (4.4 ± 2.0) was established for VMIs at 40 keV. Tumor contrast in all VMIs ≤ 60 keV was higher than in PEIs (p < 0.001). The NIC of malignant tissue measured in iodine maps was substantially lower compared with a healthy myometrium (0.3 ± 0.1 versus 0.6 ± 0.1 mg/mL; p < 0.001). Tumor conspicuity was highest in 40 keV datasets, whereas no difference was found among PEIs and VMIs at 60 and 70 keV (p ≥ 0.334). Interobserver agreement was good, indicated by an intraclass correlation coefficient of 0.824 (0.772-0.876; p < 0.001). In conclusion, computation of VMIs at 40 keV and color-coded iodine maps aids the assessment of endometroid adenocarcinoma in primary staging.

3.
Magn Reson Imaging ; 107: 100-110, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246517

RESUMO

INTRODUCTION: With increasing spatial resolution, diffusion-weighted imaging (DWI) may be suitable for morphologic lesion characterization in breast MRI - an area that has traditionally been occupied by dynamic contrast-enhanced imaging (DCE). This investigation compared DWI with b values of 800 and 1600 s/mm2 to DCE for lesion morphology assessment in high-resolution breast MRI at 3 Tesla. MATERIAL AND METHODS: Multiparametric breast MRI was performed in 91 patients with 93 histopathologically proven lesions (31 benign, 62 malignant). Two radiologists independently evaluated three datasets per patient (DWIb800; DWIb1600; DCE) and assessed lesion visibility and BIRADS morphology criteria. Diagnostic accuracy was compared among readers and datasets using Cochran's Q test and pairwise post-hoc McNemar tests. Bland-Altman analyses were conducted for lesion size comparisons. RESULTS: Discrimination of carcinomas was superior compared to benign findings in both DWIb800 and DWIb1600 (p < 0.001) with no b value-dependent difference. Similarly, assessability of mass lesions was better than of non-mass lesions, irrespective of b value (p < 0.001). Intra-reader reliability for the analysis of morphologic BIRADS criteria among DCE and DWI datasets was at least moderate (Fleiss κ≥0.557), while at least substantial inter-reader agreement was ascertained over all assessed categories (κ≥0.776). In pairwise Bland-Altman analyses, the measurement bias between DCE and DWIb800 was 0.7 mm, whereas the difference between DCE and DWIb1600 was 2.8 mm. DWIb1600 allowed for higher specificity than DCE (p = 0.007/0.062). CONCLUSIONS: DWI can be employed for reliable morphologic lesion characterization in high-resolution breast MRI. High b values increase diagnostic specificity, while lesion size assessment is more precise with standard 800 s/mm2 images.


Assuntos
Neoplasias da Mama , Meios de Contraste , Humanos , Feminino , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Sensibilidade e Especificidade , Estudos Retrospectivos
4.
Arch Orthop Trauma Surg ; 143(12): 7097-7105, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37639044

RESUMO

INTRODUCTION: The AMADEUS (Area Measurement And DEpth and Underlying Structures) score has advanced to a commonly used tool for MRI-based chondral defect severity grading prior to cartilage knee surgery. It was the intention of this study to assess the AMADEUS for a potential correlation with clinical data by patient-reported outcome measures (PROMs). METHODS: A total of 51 patients undergoing ACI (autologous chondrocyte implantation) between 2016 and 2022 were found eligible and retrospectively analyzed. All patients were registered in the German Cartilage Registry prior to surgery and follow-up data were collected using the Knee Osteoarthritis Outcome score (KOOS), the International Knee Documentation Committee (IKDC) Form and the numeric rating scale (NRS). Pre-operative MRI images were scored by three raters using the AMADEUS classification system, and an overall AMADEUS score was calculated which was subsequently correlated with pre- and post-operative PROMs. RESULTS: Mean patient age was 32.67 ± 8.37 years and mean defect size area 343.04 mm2 ± 139.45 mm2. No correlative capacity of the pre- and postoperative IKDC, KOOS or NRS scores was found with the AMADEUS final score or any of its subscores. From the pre- to postoperative visit, a significant improvement of the PROMs (IKDC: 45.53 ± 21.00 vs. 59.83 ± 17.93, p = 0.04; KOOS Pain: 58.00 ± 16.70 vs. 76.06 ± 19.20, p = 0.03; KOOS ADL: 64.17 ± 18.76 vs. 82.11 ± 16.68, p < 0.01; KOOS Sports: 26.11 ± 18.52 vs. 50.56 ± 23.94, p = 0.01; KOOS QOL: 25.50 ± 14.26 ± 45.28 ± 19.03, p = 0.00) was found. Intraclass correlation coefficients showed an overall good interrater agreement for the AMADEUS total score (ICC = 0.75). CONCLUSIONS: Study results suggest no correlative capacity of the AMADEUS with routinely used PROMs in patients undergoing ACI. Therefore, radiographically assessed cartilage defect characteristics poorly translate to pre- and postoperative patient-reported outcome data.


Assuntos
Doenças das Cartilagens , Cartilagem Articular , Osteoartrite do Joelho , Humanos , Adulto Jovem , Adulto , Condrócitos , Cartilagem Articular/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Transplante Autólogo/métodos , Articulação do Joelho/cirurgia , Doenças das Cartilagens/cirurgia , Osteoartrite do Joelho/cirurgia , Dor , Sistema de Registros
5.
Eur J Radiol ; 167: 111055, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37632998

RESUMO

PURPOSE: Leg torsion analysis can provide valuable information in symptomatic patients after total knee arthroplasty. However, extensive beam-hardening and photon-starvation artifacts limit diagnostic assessability and dose reduction potential. For this study, we investigated the reproducibility of rotational measurements in ultra-low-dose photon-counting CT with spectral shaping via tin prefiltration. MATERIAL AND METHODS: Employing a first-generation photon-counting CT, eight cadaveric specimens were examined with an established three-level scan protocol (hip: Sn 140, knee: Sn 100, ankle: Sn 100 kVp). In three body donors with unilateral knee endoprostheses, additional modified settings were applied (Sn 140 kVp at knee level). Protocols were executed with three dose levels (hip-knee-ankle, high-quality: 5.0-3.0-2.0 mGy, low-dose: 0.80-0.30-0.26 mGy, ultra-low-dose: 0.25-0.06-0.06 mGy). Six radiologists performed torsion analyses, additionally reporting their diagnostic confidence. Intraclass correlation coefficients (ICC) were calculated to assess interrater reliability. RESULTS: No significant differences were ascertained for femoral (p = 0.330), tibial (p = 0.177), and overall leg rotation measurements (p = 0.358) among high-quality, low-dose, and ultra-low-dose protocols. Interrater reliability was excellent for torsion of the femur (ICC 0.915, 95% confidence interval 0.871-0.947), tibia (0.960, 0.938-0.976), and overall leg (0.967, 0.945-0.981). In specimens with total knee endoprostheses, absolute rotational measurements were unaffected by dose level and tube voltage despite superior diagnostic confidence on the ipsilateral and contralateral sides with modified settings (p < 0.001). CONCLUSIONS: Combining the advantages of photon-counting CT and spectral shaping, reliable leg torsion analyses are feasible with ultra-low radiation exposure even in the presence of total knee endoprostheses.


Assuntos
Extremidade Inferior , Tomografia Computadorizada por Raios X , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Articulação do Joelho/cirurgia , Próteses e Implantes
6.
Cancers (Basel) ; 15(15)2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37568823

RESUMO

Multiple myeloma (MM) frequently induces persisting osteolytic manifestations despite hematologic treatment response. This study aimed to establish a biometrically valid study endpoint for bone remineralization through quantitative and qualitative analyses in sequential CT scans. Twenty patients (seven women, 58 ± 8 years) with newly diagnosed MM received standardized induction therapy comprising the anti-SLAMF7 antibody elotuzumab, carfilzomib, lenalidomide, and dexamethasone (E-KRd). All patients underwent whole-body low-dose CT scans before and after six cycles of E-KRd. Two radiologists independently recorded osteolytic lesion sizes, as well as the presence of cortical destruction, pathologic fractures, rim and trabecular sclerosis. Bland-Altman analyses and Krippendorff's α were employed to assess inter-reader reliability, which was high for lesion size measurement (standard error 1.2 mm) and all qualitative criteria assessed (α ≥ 0.74). After six cycles of E-KRd induction, osteolytic lesion size decreased by 22% (p < 0.001). While lesion size response did not correlate with the initial lesion size at baseline imaging (Pearson's r = 0.144), logistic regression analysis revealed that the majority of responding osteolyses exhibited trabecular sclerosis (p < 0.001). The sum of osteolytic lesion sizes on sequential CT scans defines a reliable study endpoint to characterize bone remineralization. Patient level response is strongly associated with the presence of trabecular sclerosis.

7.
Radiology ; 308(1): e230084, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37404154

RESUMO

Background The triple combination of the cystic fibrosis transmembrane regulator (CFTR) modulators elexacaftor, tezacaftor, and ivacaftor (hereafter, elexacaftor/tezacaftor/ivacaftor) has a positive effect on lung function in patients with cystic fibrosis (CF). Purpose To compare three-dimensional (3D) ultrashort echo time (UTE) MRI functional lung data to common functional lung parameters in assessing lung function in patients with CF undergoing elexacaftor/tezacaftor/ivacaftor therapy. Materials and Methods In this prospective feasibility study, 16 participants with CF consented to undergo pulmonary MRI with a breath-hold 3D UTE sequence at baseline (April 2018-June 2019) and follow-up (April-July 2021). Eight participants received elexacaftor/tezacaftor/ivacaftor after baseline, and eight participants with unchanged treatment served as the control group. Lung function was assessed with body plethysmography and lung clearance index (LCI). Image-based functional lung parameters, such as ventilation inhomogeneity and ventilation defect percentage (VDP), were calculated from signal intensity change between MRI scans at inspiration and expiration. Metrics at baseline and follow-up were compared within groups (permutation test), correlation was tested (Spearman rank correlation), and 95% CIs were calculated (bootstrapping technique). Results MRI ventilation inhomogeneity correlated with LCI at baseline (r = 0.92, P < .001) and follow-up (r = 0.81, P = .002). Mean MRI ventilation inhomogeneity (baseline, 0.74 ± 0.15 [SD]; follow-up, 0.64 ± 0.11; P = .02) and mean VDP (baseline, 14.1% ± 7.4; follow-up, 8.5% ± 3.3; P = .02) decreased from baseline to follow-up in the treatment group. Lung function was stable over time (mean LCI: 9.3 turnovers ± 4.1 at baseline vs 11.5 turnovers ± 7.4 at follow-up; P = .34) in the control group. In all participants, correlation of forced expiratory volume in 1 second with MRI ventilation inhomogeneity was good at baseline (r = -0.61, P = .01) but poor during follow-up (r = -0.06, P = .82). Conclusion Noncontrast 3D UTE lung MRI functional parameters of ventilation inhomogeneity and VDP can be used to assess lung function over time in patients with CF and can add regional information to established global parameters, such as LCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.


Assuntos
Fibrose Cística , Humanos , Fibrose Cística/diagnóstico por imagem , Fibrose Cística/tratamento farmacológico , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Estudos Prospectivos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mutação
8.
Diagnostics (Basel) ; 13(14)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37510150

RESUMO

Recent dissection studies resulted in the introduction of the term "chiasma antebrachii", which represents an intersection of the flexor digitorum superficialis (FDS) tendons for digits 2 and 3 in the distal third of the forearm. This retrospective investigation aimed to provide an MRI-based morphologic analysis of the chiasma antebrachii. In 89 patients (41 women, 39.3 ± 21.3 years), MRI examinations of the forearm (2010-2021) were reviewed by two radiologists, who evaluated all studies for the presence and length of the chiasma as well as its distance from the distal radioulnar and elbow joint. The chiasma antebrachii was identified in the distal third of the forearm in 88 patients (98.9%), while one intersection was located more proximally in the middle part. The chiasma had a median length of 28 mm (interquartile range: 24-35 mm). Its distances to the distal radioulnar and elbow joint were 16 mm (8-25 mm) and 215 mm (187-227 mm), respectively. T1-weighted post-contrast sequences were found to be superior to T2- or proton-density-weighted sequences in 71 cases (79.8%). To conclude, the chiasma antebrachii is part of the standard FDS anatomy. Knowledge of its morphology is important, e.g., in targeted injections of therapeutics or reconstructive surgery.

9.
Rofo ; 195(8): 699-706, 2023 08.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37348527

RESUMO

PURPOSE: Breast imaging represents an integral part of radiology and is subject to strict quality controls. Regarding this, precise diagnostics including multimodal assessment by mammography, sonography, and MRI, including image-guided biopsy and localization procedures, is often decisive and must be performed by experts with profound knowledge and skills in all of these procedures.However, due to numerous restructurings, breast imaging has been shifted more and more towards large, specialized centers, resulting in less patient exposition and training opportunities for radiologists in smaller sites. The following whitepaper summarizes the current circumstances and discusses opinions of the participating societies. MATERIALS: Under the leadership of the German Roentgen Society (DRG) and with the participation of the DRG's AG Mammadiagnostik, the CAFRAD (Chefarztforum Radiologie), the KLR (Konferenz der Lehrstuhlinhaber für Radiologie e. V.), the DRG's Forum Junge Radiologie (FJR) and the Berufsverband der Deutschen Radiologen e. V. (BDR), possible solutions were discussed and consented for a structured training in breast radiology in the future. RESULTS: In addition to the teaching provided at the primary workplace, qualified training should be ensured through flexible, multi-institutional, interdisciplinary, and cross-sectoral collaboration. Furthermore, the integration of online case collections and close cooperation with certified breast cancer centers and mammography screening units is recommended. It is indispensible that online courses and case collections adhere to the standards of the national societies and include a maximum of one third of the required cases. CONCLUSION: In order to provide training in breast radiology at a high professional level, a paradigm shift with closer cooperation of all participants is necessary. This includes close collaboration of the breast imaging societies with the federal medical associations to establish new teaching concepts like e-learning in the training schedule of radiologists. KEY POINTS: · Breast diagnostics is an integral part of radiology training.. · Due to recent restructurings, smaller training centers have difficulties in meeting the case numbers demanded by the Specialist Training Regulations (WBO). Improved integration of the new structures and their adaptation to the needs of education are necessary to guarantee standardized high-quality training of young radiologists.. · The integration of certified case collections enables quality-assured training, even across regions in online-based formats. In accordance with the "blended learning principle", up to one-third of the required number of patient studies can be substituted with cases from a certified case collection.. · Legally secured short- and medium-term internships may complement training in radiology.. CITATION FORMAT: · Sauer ST, Bley TA, Wenkel E et al. Whitepaper: Training in Diagnostic and Interventional Breast Radiology. Fortschr Röntgenstr 2023; 195: 699 - 706.


Assuntos
Currículo , Radiologia Intervencionista , Humanos , Aprendizagem , Mamografia , Ultrassonografia
10.
Diagnostics (Basel) ; 13(9)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37174949

RESUMO

OBJECTIVES: Dual-source dual-energy CT (DECT) facilitates reconstruction of virtual non-contrast images from contrast-enhanced scans within a limited field of view. This study evaluates the replacement of true non-contrast acquisition with virtual non-contrast reconstructions and investigates the limitations of dual-source DECT in obese patients. MATERIALS AND METHODS: A total of 253 oncologic patients (153 women; age 64.5 ± 16.2 years; BMI 26.6 ± 5.1 kg/m2) received both multi-phase single-energy CT (SECT) and DECT in sequential staging examinations with a third-generation dual-source scanner. Patients were allocated to one of three BMI clusters: non-obese: <25 kg/m2 (n = 110), pre-obese: 25-29.9 kg/m2 (n = 73), and obese: >30 kg/m2 (n = 70). Radiation dose and image quality were compared for each scan. DECT examinations were evaluated regarding liver coverage within the dual-energy field of view. RESULTS: While arterial contrast phases in DECT were associated with a higher CTDIvol than in SECT (11.1 vs. 8.1 mGy; p < 0.001), replacement of true with virtual non-contrast imaging resulted in a considerably lower overall dose-length product (312.6 vs. 475.3 mGy·cm; p < 0.001). The proportion of DLP variance predictable from patient BMI was substantial in DECT (R2 = 0.738) and SECT (R2 = 0.620); however, DLP of SECT showed a stronger increase in obese patients (p < 0.001). Incomplete coverage of the liver within the dual-energy field of view was most common in the obese subgroup (17.1%) compared with non-obese (0%) and pre-obese patients (4.1%). CONCLUSION: DECT facilitates a 30.8% dose reduction over SECT in abdominal oncologic staging examinations. Employing dual-source scanner architecture, the risk for incomplete liver coverage increases in obese patients.

11.
Br J Radiol ; 96(1145): 20220967, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36972100

RESUMO

OBJECTIVES: Digital breast tomosynthesis (DBT) can provide additional information over mammography, albeit at the cost of prolonged reading time. This study retrospectively investigated the impact of reading enhanced synthetic 6 mm slabs instead of standard 1 mm slices on interpretation time and readers performance in a diagnostic assessment centre. METHODS: Three radiologists (R1-3; 6/4/2 years of breast imaging experience) reviewed 111 diagnostic DBT examinations. Two datasets were interpreted independently for each patient, with one set containing artificial-intelligence-enhanced synthetic 6 mm slabs with 3 mm overlap, while the other set comprised standard 1 mm slices. Blinded to histology and follow-up, readers noted individual BIRADS categories and diagnostic confidence while reading time was recorded. Among the 111 examinations, 70 findings were histopathologically correlated including 56 malignancies. RESULTS: No significant difference was found between BIRADS categories assigned based on 6 mm vs 1 mm datasets (p ≥ 0.317). Diagnostic accuracy was comparable for 6 mm and 1 mm readings (R1: 87.0% vs 87.0%; R2: 86.1% vs 87.0%; R3: 80.0% vs 84.4%; p ≥ 0.125) with high interrater agreement (intraclass correlation coefficient 0.848 vs 0.865). One reader reported higher confidence with 1 mm slices (R1: p = 0.033). Reading time was substantially shorter when interpreting 6 mm slabs compared to 1 mm slices (R1: 33.5 vs 46.2; R2: 49.1 vs 64.8; R3: 39.5 vs 67.2 sec; all p < 0.001). CONCLUSIONS: Artificial-intelligence-enhanced synthetic 6 mm slabs allow for substantial interpretation time reduction in diagnostic DBT without a decrease in reader accuracy. ADVANCES IN KNOWLEDGE: A simplified slab-only protocol instead of 1 mm slices may offset the higher reading time without a loss of diagnosis-relevant image information in first and second readings. Further evaluations are required regarding workflow implications, particularly in screening settings.


Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Estudos Retrospectivos , Mamografia/métodos , Exame Físico , Radiologistas , Inteligência , Neoplasias da Mama/diagnóstico por imagem
12.
Acad Radiol ; 30(9): 1773-1783, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36764882

RESUMO

RATIONALE AND OBJECTIVES: In breast MRI with diffusion-weighted imaging (DWI), fat suppression is essential for eliminating the dominant lipid signal. This investigation evaluates a combined water-excitation-spectral-fatsat method (WEXfs) versus standard spectral attenuated inversion recovery (SPAIR) in high-resolution 3-Tesla breast MRI. MATERIALS AND METHODS: Multiparametric breast MRI with 2 echo-planar DWI sequences was performed in 83 patients (50.1 ± 12.6 years) employing either WEXfs or SPAIR for fat signal suppression. Three radiologists assessed overall DWI quality and delineability of 88 focal lesions (28 malignant, 60 benign) on images with b values of 800 and 1600 s/mm2, as well as apparent diffusion coefficient (ADC) maps. For each fat suppression method and b value, the longest lesion diameter was determined in addition to measuring the signal intensity in DWI and ADC value in standardized regions of interest. RESULTS: Regardless of b values, image quality (all p < 0.001) and lesion delineability (all p ≤ 0.003) with WEXfs-DWI were deemed superior compared to SPAIR-DWI in benign and malignant lesions. Irrespective of lesion characterization, WEXfs-DWI provided superior signal-to-noise, contrast-to-noise and signal-intensity ratios with 1600 s/mm2 (all p ≤ 0.05). The lesion size difference between contrast-enhanced T1 subtraction images and DWI was smaller for WEXfs compared to SPAIR fat suppression (all p ≤ 0.007). The mean ADC value in malignant lesions was lower for WEXfs-DWI (p < 0.001), while no significant ADC difference was ascertained between both techniques in benign lesions (p = 0.947). CONCLUSION: WEXfs-DWI provides better subjective and objective image quality than standard SPAIR-DWI, resulting in a more accurate estimation of benign and malignant lesion size.


Assuntos
Neoplasias Encefálicas , Neoplasias da Mama , Feminino , Humanos , Neoplasias Encefálicas/patologia , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar , Adulto , Pessoa de Meia-Idade
13.
Radiology ; 306(3): e221200, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36346312

RESUMO

Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees of positioning freedom for three-dimensional elbow scans over gantry-based multidetector CT (MDCT), but studies analyzing their clinical value remain lacking. Purpose To investigate the diagnostic performance of gantry-free CBCT versus two-dimensional radiography in adults and children with acute elbow trauma. Materials and Methods In a retrospective study, consecutive patients with elbow trauma and positioning difficulty in a gantry-based MDCT who underwent three-dimensional elbow imaging with a gantry-free CBCT after radiography were enrolled between January 2021 and April 2022 at a tertiary care university hospital. Imaging data sets were independently analyzed for fracture presence, articular involvement, and multi-fragment injuries by three radiologists. Diagnostic performance was calculated individually with surgical reports serving as the reference standard. Differences between radiography and CBCT were compared with the McNemar test. Diagnostic confidence was estimated subjectively by each reader, and results were compared with the Wilcoxon signed-rank test. Results Elbow examinations of 23 adults and children (mean age ± SD, 49 years ± 23; seven women) were included with individual assessment of humerus, radius, and ulna (69 bones; 36 fractured). Multi-fragmentary fracture patterns and involvement of articular surfaces were ascertained in 28 and 30 bones, respectively. CBCT allowed for similar or higher sensitivity compared with radiography in the assessment of fractures (range for three readers, 94%-100% vs 72%-81%; respectively, P ≤ .06-.008), articular surface involvement (90%-97% vs 73%-87%; P ≤ .25), and multi-fragmentary patterns (96%-96% vs 68%-75%; P ≤ .03). Readers' diagnostic confidence improved considerably with access to CBCT data sets versus radiographs (all P ≤ .001). For CBCT, the median dose-length product was 70.9 mGy · cm, and the volume CT dose index was 4.4 mGy. Conclusion In acute elbow injuries, gantry-free cone-beam CT enabled improved detection of fractures, articular involvement, and multi-fragmentary patterns compared with two-dimensional radiography. Published under a CC BY 4.0 license Online supplemental material is available for this article.


Assuntos
Fraturas Ósseas , Procedimentos Cirúrgicos Robóticos , Adulto , Criança , Humanos , Feminino , Doses de Radiação , Cotovelo , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico/métodos , Fraturas Ósseas/diagnóstico por imagem
14.
Sci Rep ; 12(1): 15549, 2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36114270

RESUMO

Cone-beam computed tomography (CBCT) has been shown to be a powerful tool for 3D imaging of the appendicular skeleton, allowing for detailed visualization of bone microarchitecture. This study was designed to compare artifacts in the presence of osteosynthetic implants between CBCT and multidetector computed tomography (MDCT) in cadaveric wrist scans. A total of 32 scan protocols with varying tube potential and current were employed: both conventional CBCT and MDCT studies were included with tube voltage ranging from 60 to 140 kVp as well as additional MDCT protocols with dedicated spectral shaping via tin prefiltration. Irrespective of scanner type, all examinations were conducted in ultra-high-resolution (UHR) scan mode. For reconstruction of UHR-CBCT scans an additional iterative metal artifact reduction algorithm was employed, an image correction tool which cannot be used in combination with UHR-MDCT. To compare applied radiation doses between both scanners, the volume computed tomography dose index for a 16 cm phantom (CTDIvol) was evaluated. Images were assessed regarding subjective and objective image quality. Without automatic tube current modulation or tube potential control, radiation doses ranged between 1.3 mGy (with 70 kVp and 50.0 effective mAs) and 75.2 mGy (with 140 kVp and 383.0 effective mAs) in UHR-MDCT. Using the pulsed image acquisition method of the CBCT scanner, CTDIvol ranged between 2.3 mGy (with 60 kVp and 0.6 mean mAs per pulse) and 61.0 mGy (with 133 kVp and 2.5 mean mAs per pulse). In essence, all UHR-CBCT protocols employing a tube potential of 80 kVp or more were found to provide superior overall image quality and artifact reduction compared to UHR-MDCT (all p < .050). Interrater reliability of seven radiologists regarding image quality was substantial for tissue assessment and moderate for artifact assessment with Fleiss kappa of 0.652 (95% confidence interval 0.618-0.686; p < 0.001) and 0.570 (95% confidence interval 0.535-0.606; p < 0.001), respectively. Our results demonstrate that the UHR-CBCT scan mode of a twin robotic X-ray system facilitates excellent visualization of the appendicular skeleton in the presence of metal implants. Achievable image quality and artifact reduction are superior to dose-comparable UHR-MDCT and even MDCT protocols employing spectral shaping with tin prefiltration do not achieve the same level of artifact reduction in adjacent soft tissue.


Assuntos
Artefatos , Procedimentos Cirúrgicos Robóticos , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Reprodutibilidade dos Testes , Estanho , Raios X
15.
Eur J Radiol ; 155: 110493, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36027759

RESUMO

PURPOSE: We tested a novel multi-parametric (mp) whole body (WB)-MRI evaluation algorithm for medullary lesions in comparison to positron emission tomography (PET) radiotracers 18F-fluorodeoxyglucose (18F-FDG) and 11C-methionine (11C-MET). METHODS AND MATERIALS: This retrospective single-center study included 44 MM patients, who received both 18F-FDG-PET and WB-MRI within ten days. MRI classified focal lesions as vital when showing 1) significant diffusion-restriction, 2) a fat fraction (FF) less than 20 % and 3) homogenous hypointensity on T2-weighted images. On a lesion-by-lesion level the findings were compared to 18F-FDG PET by using a 5-point scoring system (analogous to the Deauville score [DS]). In 24/44 (55 %) patients additional comparison to 11C-MET PET was available. RESULTS: Among two radiologists, an excellent inter-observer reliability for mpWB-MRI in a total of 84 medullary lesions was observed (ICC = 1, k = 1, p <.01). 16/17 (94.1 %) MRI-classified vital lesions had a DS of 4 or 5 on either 18F-FDG-PET or 11C-MET-PET. MRI-rated non-vital lesions correlated with PET-based DS ≤ 3. When results of mpWB-MRI were compared to 18F-FDG, a fair inter-observer agreement was recorded (ICC = 0.52, k = 0.53, p <.01), while for 11C-MET, an excellent concordance rate was achieved (ICC = 0.81, k = 0.79, p <.01). CONCLUSION: The proposed mpWB-MRI interpretation algorithm allowed to assess tumor activity of myeloma lesions with high inter-observer reproducibility. We observed a substantial concordance between the mpWB-MRI classification of lesions and PET assessment based on a semi-automatically calculated 5-point scoring system analogous to the Deauville scores.


Assuntos
Fluordesoxiglucose F18 , Mieloma Múltiplo , Humanos , Imageamento por Ressonância Magnética/métodos , Metionina , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Racemetionina , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
16.
Acad Radiol ; 29(1): e1-e8, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33139155

RESUMO

RATIONALE AND OBJECTIVES: Our study compared sensitivity, specificity, and accuracy of whole-body diffusion-weighted imaging (WB-DWI) using a b-value of 2000 s/mm2 with that of the commonly used b-value of 800 s/mm2 for depiction of active tumor sites in patients with plasma cell diseases. We introduced an ultrahigh b-value to reduce interfering signals from benign and post-therapeutic inactive lesions by suppressing T2-shine-through effects. MATERIALS AND METHODS: The prospective single-center study included patients when they went through a whole-body MRI (WB-MRI) staging or response evaluation procedure. The apparent diffusion coefficient (ADC) and morphologic appearance served as reference for classifying focal lesions on WB-DWI as vital or post-therapeutic. Additionally, we compared our classification with patients' serological markers of disease activity. RESULTS: One hundred participants (65 ± 10 years, 58 men) underwent WB-DWI between June and October 2019. The detection rate of vital focal lesions was similar for both b-values with a sensitivity of 0.99 using b = 800 s/mm2 and 0.98 using b = 2000 s/mm2. By contrast, specificity and accuracy were 0.09 and 0.71 when using a b-value of 800 s/mm2, and 0.96 and 0.98 when using a b-value of 2000 s/mm2, respectively. The difference in specificity and accuracy was statistically significant (p < 0.001). CONCLUSION: Using a b-value of 2000 s/mm2 significantly improved the specificity of lesion detection with WB-DWI as compared to the commonly used b-value of 800 s/mm2. The high b-value significantly reduced signal intensities of post-therapeutic or benign lesions and provided a significantly more accurate representation of active tumor load.


Assuntos
Paraproteinemias , Imagem Corporal Total , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade
17.
Eur Radiol ; 32(2): 1276-1284, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34347156

RESUMO

OBJECTIVES: Vessel wall enhancement (VWE) may be commonly seen on MRI images of asymptomatic subjects. This study aimed to characterize the VWE of the proximal internal carotid (ICA) and vertebral arteries (VA) in a non-vasculitic elderly patient cohort. METHODS: Cranial MRI scans at 3 Tesla were performed in 43 patients (aged ≥ 50 years) with known malignancy for exclusion of cerebral metastases. For vessel wall imaging (VWI), a high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo sequence (T1 CS-SPACE prototype) was applied post gadolinium with an isotropic resolution of 0.55 mm. Bilateral proximal intradural ICA and VA segments were evaluated for presence, morphology, and longitudinal extension of VWE. RESULTS: Concentric VWE of the proximal intradural ICA was found in 13 (30%) patients, and of the proximal intradural VA in 39 (91%) patients. Mean longitudinal extension of VWE after dural entry was 13 mm in the VA and 2 mm in the ICA. In 14 of 39 patients (36%) with proximal intradural VWE, morphology of VWE was suggestive of the mere presence of vasa vasorum. In 25 patients (64 %), morphology indicated atherosclerotic lesions in addition to vasa vasorum. CONCLUSIONS: Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in elderly subjects. Concentric VWE in these locations should not be confused with large artery vasculitis. Distal to these segments, VWE may be more likely related to pathologic conditions such as vasculitis. KEY POINTS: • Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in non-vasculitic elderly people. • Concentric enhancement within the proximal 2 mm of the intradural ICA and within the proximal 13 mm of the intradural VA portions should not be misinterpreted as vasculitis. • Distal of this, VWE is likely related to pathologic conditions, in case of concentric VWE suggestive of vasculitis.


Assuntos
Vasa Vasorum , Vasculite , Idoso , Artérias Cerebrais , Humanos , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Vasa Vasorum/diagnóstico por imagem
18.
Eur J Endocrinol ; 186(2): 183-193, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34813495

RESUMO

OBJECTIVE: Reliable results of wash-out CT in the diagnostic workup of adrenal incidentalomas are scarce. Thus, we evaluated the diagnostic accuracy of delayed wash-out CT and determined thresholds to accurately differentiate adrenal masses. DESIGN: Retrospective, single-center cohort study including 216 patients with 252 adrenal lesions who underwent delayed wash-out CT. Definitive diagnoses based on histopathology (n = 92) or comprehensive follow-up. METHODS: Size, average attenuation values of the adrenal lesions in all CT scan phases, and absolute and relative percentage wash-out (APW/RPW) were determined by an expert radiologist blinded for clinical data. Adrenal lesions with unenhanced attenuation values >10 Hounsfield units (HU) built a subgroup (n = 142). Diagnostic accuracy was calculated. RESULTS: The study group consisted of 171 adenomas, 32 other benign tumors, 11 pheochromocytomas, 9 adrenocortical carcinomas, and 29 other malignant tumors. All (potentially) malignant and 46% of benign lesions showed unenhanced attenuation values >10 HU. In this most relevant subgroup, the established thresholds of 60% for APW and 40% for RPW misclassified 35.9 and 35.2% of the masses, respectively. When we applied optimized cutoffs (APW >83%; RPW >58%) and excluded pheochromocytomas, we missed only one malignant tumor by APW and none by RPW. However, only 11 and 15% of the benign tumors were correctly identified. CONCLUSIONS: Wash-out CT with the established thresholds for APW and RPW is insufficient to reliably diagnose adrenal masses. Using the proposed cutoff of 58% for RPW, malignant tumors will be correctly identified, but the added value is limited, namely 15% of patients with benign tumors can be prevented from additional imaging or even unnecessary surgery.


Assuntos
Neoplasias do Córtex Suprarrenal/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Adenoma Adrenocortical/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Córtex Suprarrenal/fisiopatologia , Neoplasias das Glândulas Suprarrenais/fisiopatologia , Adenoma Adrenocortical/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/normas
19.
Sci Rep ; 11(1): 20176, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34635787

RESUMO

Cone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current-time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70%) and mULD (0/3/5%). Superior depiction of cortical and cancellous bone was achieved in FDUr77 and LDUr77 examinations (p < 0.001) with LDUr77 scans also providing favorable bone visualization compared to FDBr69 and FDBr62 (p < 0.001). Fleiss' kappa was 0.618 (0.594-0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Procedimentos Cirúrgicos Robóticos/métodos , Extremidade Superior/diagnóstico por imagem , Cadáver , Humanos , Doses de Radiação , Extremidade Superior/cirurgia , Raios X
20.
Eur J Radiol ; 143: 109901, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34392004

RESUMO

PURPOSE: Although lesions of the triangular fibrocartilage complex (TFCC) frequently induce ulnar-sided wrist pain and potentially distal radioulnar joint instability, diagnosis can pose a challenge due to the intricate anatomy. This study aims to evaluate the benefits of contrast-enhanced sequences for the detection of TFCC injuries in magnetic resonance imaging of the wrist. METHOD: 94 patients underwent wrist MRI with intravenous application of gadolinium-based contrast agents. For each patient, two datasets were analysed independently by two board-certified radiologists: One set comprised only plain T1- and fat-saturated proton-density-weighted sequences, while the second dataset included contrast-enhanced T1-weighted images with fat suppression. Arthroscopy or clinical reports served as reference standard with the former being used whenever available. Diagnostic confidence and TFCC component assessability were subjectively evaluated. Contrast-to-noise ratios (CNR) were calculated serve as an objective indicator of image contrast. RESULTS: Lesions of the articular disc, the foveal and styloid ulnar attachment were present in 24 (25.5%), 61 (64.9%) and 53 (56.4%) patients. Access to contrast-enhanced T1 images improved the diagnostic accuracy for injuries of the styloid (R1/R2, 0.68/0.73 vs. 0.86/0.88) and foveal attachment (0.68/0.72 vs. 0.90/0.89) substantially compared to plain MRI (all p < 0.001), while no benefits could be identified for lesions of the central disc (0.89/0.90 vs. 0.87/0.90). Readers' diagnostic confidence and CNR for ulnar-sided lesions improved with contrast-enhanced T1 sequences available (p < 0.001). CONCLUSIONS: With superior CNR in lesions of the TFCC's foveal and styloid attachment, contrast-enhanced, fat-saturated T1-weighted sequences facilitate higher diagnostic accuracy and confidence than fat-saturated PD- and plain T1-weighted MRI.


Assuntos
Fibrocartilagem Triangular , Traumatismos do Punho , Artroscopia , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Fibrocartilagem Triangular/diagnóstico por imagem , Punho , Traumatismos do Punho/diagnóstico por imagem , Articulação do Punho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA