Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Gastrointest Endosc ; 97(3): 537-543.e2, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36228700

RESUMO

BACKGROUND AND AIMS: Performing a high-quality colonoscopy is critical for optimizing the adenoma detection rate (ADR). Colonoscopy withdrawal time (a surrogate measure) of ≥6 minutes is recommended; however, a threshold of a high-quality withdrawal and its impact on ADR are not known. METHODS: We examined withdrawal time (excluding polyp resection and bowel cleaning time) of subjects undergoing screening and/or surveillance colonoscopy in a prospective, multicenter, randomized controlled trial. We examined the relationship of withdrawal time in 1-minute increments on ADR and reported odds ratio (OR) with 95% confidence intervals. Linear regression analysis was performed to assess the maximal inspection time threshold that impacts the ADR. RESULTS: A total of 1142 subjects (age, 62.3 ± 8.9 years; 80.5% men) underwent screening (45.9%) or surveillance (53.6%) colonoscopy. The screening group had a median withdrawal time of 9.0 minutes (interquartile range [IQR], 3.3) with an ADR of 49.6%, whereas the surveillance group had a median withdrawal time of 9.3 minutes (IQR, 4.3) with an ADR of 63.9%. ADR correspondingly increased for a withdrawal time of 6 minutes to 13 minutes, beyond which ADR did not increase (50.4% vs 76.6%, P < .01). For every 1-minute increase in withdrawal time, there was 6% higher odds of detecting an additional subject with an adenoma (OR, 1.06; 95% confidence interval, 1.02-1.10; P = .004). CONCLUSIONS: Results from this multicenter, randomized controlled trial underscore the importance of a high-quality examination and efforts required to achieve this with an incremental yield in ADR based on withdrawal time. (Clinical trial registration number: NCT03952611.).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Neoplasias Colorretais/diagnóstico , Fatores de Tempo , Adenoma/diagnóstico , Colonoscopia/métodos , Detecção Precoce de Câncer , Pólipos do Colo/diagnóstico
2.
Clin Gastroenterol Hepatol ; 20(9): 2023-2031.e6, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34979245

RESUMO

BACKGROUND AND AIMS: Mucosal exposure devices including distal attachments such as the cuff and cap have shown variable results in improving adenoma detection rate (ADR) compared with high-definition white light colonoscopy (HDWLE). METHODS: We performed a prospective, multicenter randomized controlled trial in patients undergoing screening or surveillance colonoscopy comparing HDWLE to 2 different types of distal attachments: cuff (CF) (Endocuff Vision) or cap (CP) (Reveal). The primary outcome was ADR. Secondary outcomes included adenomas per colonoscopy, advanced adenoma and sessile serrated lesion detection rate, right-sided ADR, withdrawal time, and adverse events. Continuous variables were compared using Student's t test and categorical variables were compared using chi-square or Fisher's exact test using statistical software Stata version16. A P value <.05 was considered significant. RESULTS: A total of 1203 subjects were randomized to either HDWLE (n = 384; mean 62 years of age; 81.3% males), CF (n = 379; mean 62.7 years of age; 79.9% males) or CP (n = 379; mean age 62.1 years of age; 80.5% males). No significant differences were found among 3 groups for ADR (57.3%, 59.1%, and 55.7%; P = .6), adenomas per colonoscopy (1.4 ± 1.9, 1.6 ± 2.4, and 1.4 ± 2; P = .3), advanced adenoma (7.6%, 9.2%, and 8.2%; P = .7), sessile serrated lesion (6.8%, 6.3%, and 5.5%; P = .8), or right ADR (48.2%, 49.3%, and 46.2%; P = .7). The number of polyps per colonoscopy were significantly higher in the CF group compared with HDWLE and CP group (2.7 ± 3.4, 2.3 ± 2.5, and 2.2 ± 2.3; P = .013). In a multivariable model, after adjusting for age, sex, body mass index, withdrawal time, and Boston Bowel Preparation Scale score, there was no impact of device type on the primary outcome of ADR (P = .77). In screening patients, CF resulted in more neoplasms per colonoscopy (CF: 1.7 ± 2.6, HDWLE: 1.3 ± 1.7, and CP: 1.2 ± 1.8; P = .047) with a shorter withdrawal time. CONCLUSIONS: Results from this multicenter randomized controlled trial do not show any significant benefit of using either distal attachment devices (CF or CP) over HDWLE, at least in high-detector endoscopists. The Endocuff may have an advantage in the screening population. (ClinicalTrials.gov, Number: NCT03952611).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Idoso , Idoso de 80 Anos ou mais , Colonoscopia , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Gastrointest Endosc ; 91(1): 115-120, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31299257

RESUMO

BACKGROUND AND AIMS: Devices for flattening colon folds can improve polyp detection at colonoscopy. However, there are few data on the endoscopic ring-fitted cap (EndoRings; EndoAid, Caesarea, Israel). We sought to compare adenoma detection with EndoRings with that of standard high-definition colonoscopy. METHODS: This was a single-center, randomized controlled trial of 562 patients (284 randomized to EndoRings and 278 to standard colonoscopy) at 2 outpatient endoscopy units in the Indiana University Hospital system. Adenoma detection was the primary outcome measured as adenoma detection rate (ADR) and adenomas per colonoscopy (APC). We also compared sessile serrated polyp detection rate, insertion times, withdrawal times, and ease of passage through the sigmoid colon. RESULTS: EndoRings was superior to standard colonoscopy in terms of APC (1.46 vs 1.06, P = .025), but there were no statistically significant differences in ADR or sessile serrated polyp detection rate. Mean withdrawal time (in patients with no polyps) was shorter and insertion time (all patients) was longer in the EndoRings arm by 1.8 minutes and 0.75 minutes, respectively. One provider had significantly higher detection with Endo-Rings and contributed substantially to the overall results. CONCLUSIONS: EndoRings can increase adenoma detection without a significant increase in procedure time, but the effect varies between operators. The use of EndoRings slows colonoscope insertion. (Clinical trial registration number: NCT03418662.).


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/instrumentação , Adenoma/patologia , Idoso , Neoplasias do Colo/patologia , Pólipos do Colo/patologia , Colonoscópios , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
4.
Gastrointest Endosc ; 90(5): 835-840.e1, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31319060

RESUMO

BACKGROUND AND AIMS: Endocuff (Arc Medical Design, Leeds, UK) and Endocuff Vision (Arc Medical Design, Leeds, UK) are effective mucosal exposure devices for improving polyp detection during colonoscopy. AmplifEYE (Medivators Inc, Minneapolis, Minn, USA) is a device that appears similar to the Endocuff devices but has received minimal clinical testing. METHODS: We performed a randomized controlled clinical trial using a noninferiority design to compare Endocuff Vision with AmplifEYE. RESULTS: The primary endpoint of adenomas per colonoscopy was similar in AmplifEYE at 1.63 (standard deviation 2.83) versus 1.51 (2.29) with Endocuff Vision (P = .535). The 95% lower confidence limit was 0.88 for ratio of means, establishing noninferiority of AmplifEYE (P = .008). There was no difference between the arms for mean insertion time, and mean inspection time (withdrawal time minus polypectomy time and time for washing and suctioning) was shorter with AmplifEYE (6.8 minutes vs 6.9 minutes, P = .042). CONCLUSIONS: AmplifEYE is noninferior to Endocuff Vision for adenoma detection. The decision on which device to use can be based on cost. Additional comparisons of AmplifEYE with Endocuff by other investigators are warranted. (Clinical trial registration number: NCT03560128.).


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Colonoscopia/instrumentação , Idoso , Detecção Precoce de Câncer , Feminino , Humanos , Mucosa Intestinal/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA