Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Refract Surg ; 40(5): e313-e320, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717079

RESUMO

PURPOSE: To assess the clinical outcomes and safety profiles of patients who underwent immediate sequential bilateral phakic lens surgery. METHODS: This retrospective multicenter study included 254 consecutive patients (508 eyes) who underwent bilateral same-day Implantable Collamer Lens (ICL) (STAAR Surgical) surgery. The authors focused on 1-year postoperative clinical outcomes and adverse events. RESULTS: In the initial cohort, 176 patients (352 eyes) met inclusion criteria. Of these, 335 eyes underwent myopic ICL placement, and 17 eyes received a hyperopic ICL. Notably, 87% of eyes achieved ±0.50 diopters (D) and 95% achieved ±1.00 D of the intended refraction. One year postoperatively, 78% of eyes demonstrated optimal vaulting (250 to 750 µm), with a significant 19% reduction in vaulting observed over the 12 months (P < .001). Only minor adverse events, including early cataract formation (1 case), secondary toric ICL rotation (3 cases), and ICL exchange due to inappropriate vaulting (6 cases), were noted. CONCLUSIONS: The findings corroborate the safety and efficacy of immediate sequential bilateral phakic lens surgery and indicate its potential as a treatment option. The low incidence of minor adverse events further reinforces its favorable safety profile. [J Refract Surg. 2024;40(5):e313-e320.].


Assuntos
Hiperopia , Implante de Lente Intraocular , Miopia , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Acuidade Visual/fisiologia , Feminino , Adulto , Miopia/cirurgia , Miopia/fisiopatologia , Refração Ocular/fisiologia , Hiperopia/cirurgia , Hiperopia/fisiopatologia , Adulto Jovem , Resultado do Tratamento , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Seguimentos , Adolescente
2.
J Cataract Refract Surg ; 49(7): 724-731, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36913536

RESUMO

PURPOSE: To compare the predicted vault using machine learning with the achieved vault using the online manufacturer's nomogram in patients undergoing posterior chamber implantation with an implantable collamer lens (ICL). SETTING: Centro Oculistico Bresciano, Brescia, Italy, and I.R.C.C.S.-Bietti Foundation, Rome, Italy. DESIGN: Retrospective multicenter comparison study. METHODS: 561 eyes from 300 consecutive patients who underwent ICL placement surgery were included in this study. All preoperative and postoperative measurements were obtained by anterior segment optical coherence tomography (AS-OCT; MS-39). The actual vault was quantitatively measured and compared with the predicted vault using machine learning of AS-OCT metrics. RESULTS: A strong correlation between model predictions and achieved vaulting was detected by random forest regression (RF; R2 = 0.36), extra tree regression (ET; R2 = 0.50), and extreme gradient boosting regression ( R2 = 0.39). Conversely, a high residual difference was observed between achieved vaulting values and those predicted by the multilinear regression ( R2 = 0.33) and ridge regression ( R2 = 0.33). ET and RF regressions showed significantly lower mean absolute errors and higher percentages of eyes within ±250 µm of the intended ICL vault compared with the conventional nomogram (94%, 90%, and 72%, respectively; P < .001). ET classifiers achieved an accuracy (percentage of vault in the range of 250 to 750 µm) of up to 98%. CONCLUSIONS: Machine learning of preoperative AS-OCT metrics achieved excellent predictability of ICL vault and size, which was significantly higher than the accuracy of the online manufacturer's nomogram, providing the surgeon with a valuable aid for predicting the ICL vault.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Inteligência Artificial , Implante de Lente Intraocular/métodos , Miopia/cirurgia , Tomografia de Coerência Óptica/métodos , População Branca , Estudos Retrospectivos
3.
J Ophthalmol ; 2022: 1004977, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35747583

RESUMO

This topical review aimed to update and clarify the behavioral, pharmacological, surgical, and optical strategies that are currently available to prevent and reduce myopia progression. Myopia is the commonest ocular abnormality; reinstated interest is associated with high and increasing prevalence, especially but not, in the Asian population and progressive nature in children. The growing global prevalence seems to be associated with both genetic and environmental factors such as spending more time indoor and using digital devices, particularly during the coronavirus disease 2019 pandemic. Various options have been assessed to prevent or reduce myopia progression in children. In this review, we assess the effects of several types of measures, including spending more time outdoor, optical interventions such as the bifocal/progressive spectacle lenses, soft bifocal/multifocal/extended depth of focus/orthokeratology contact lenses, refractive surgery, and pharmacological treatments. All these options for controlling myopia progression in children have various degrees of efficacy. Atropine, orthokeratology/peripheral defocus contact and spectacle lenses, bifocal or progressive addition spectacles, and increased outdoor activities have been associated with the highest, moderate, and lower efficacies, respectively.

4.
J Refract Surg ; 38(5): 288-297, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35536710

RESUMO

PURPOSE: To report 6-month visual and refractive outcomes following PRESBYOND Laser Blended Vision (Carl Zeiss Meditec) treatment using non-linear aspheric micro-anisometropia laser in situ keratomileusis (LASIK) for the correction of myopic and hyperopic presbyopia. METHODS: A retrospective, non-comparative study of 139 consecutive patients with a mean age of 53.13 ± 5.84 years (range: 42 to 70 years) treated with LASIK-induced micro-anisometropia using the MEL 90 excimer laser and VisuMax femtosecond laser (both Carl Zeiss Meditec). The target refraction was plano for distance eyes (dominant eye) and between -0.50 and -1.50 diopters (D) for near eyes. Patients were observed for 6 months. RESULTS: A total of 278 eyes (78 myopic and 200 hyperopic) from 139 patients completed the study. Mean preoperative spherical equivalent (SE) was -3.40 ± 1.83 D (range: -0.50 to -8.25 D) for myopic eyes and +1.61 ± 0.98 D (range: -1.25 to +4.63 D) for hyperopic eyes. Mean postoperative SE refraction of distance eyes was +0.20 ± 0.35 D (range: -0.38 to +1.00 D) and -0.14 ± 0.42 D (range: -1.38 to +0.88 D) for myopic and hyperopic eyes, respectively. Mean postoperative SE refraction of near eyes was -0.90 ± 0.44 D (range: -0.13 to -2.25 D) and -1.21 ± 0.48 D (range: -0.13 to -2.25 D) for myopic and hyperopic eyes, respectively. Mean binocular uncorrected near visual acuity was 0.70 ± 0.28 logMAR (range: 0.32 to 1.00 logMAR) and 0.79 ± 0.27 logMAR (range: 0.25 to 1.00 logMAR) for myopic and hyperopic eyes, respectively. Mean binocular uncorrected distance visual acuity was 1.19 ± 0.18 logMAR (range: 0.63 to 1.25 logMAR) and 1.14 ± 0.26 logMAR (range: 0.40 to 1.25 logMAR) for myopic and hyperopic eyes, respectively. Stereoacuity was better than 100 seconds of arc in 79% of myopic eyes and 85% of hyperopic eyes and all vision quality scores were greater than 90 of 100. No eyes lost two or more lines. CONCLUSIONS: The non-linear aspheric micro-anisometropia protocol resulted in safe and effective visual outcomes in patients with both myopic and hyperopic presbyopia. [J Refract Surg. 2022;38(5):288-297.].


Assuntos
Anisometropia , Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Presbiopia , Anisometropia/cirurgia , Topografia da Córnea , Humanos , Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Pessoa de Meia-Idade , Miopia/cirurgia , Presbiopia/cirurgia , Refração Ocular , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA