Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
ACS Biomater Sci Eng ; 10(5): 3331-3342, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38600786

RESUMO

Microbubbles (MBs) hold substantial promise for medical imaging and therapy; nonetheless, knowledge gaps persist between composition, structure, and in vivo performance, especially with respect to pharmacokinetics. Of particular interest is the role of the poly(ethylene glycol) (PEG) layer, which is thought to shield the MB against opsonization and rapid clearance but is also known to cause an antibody response upon multiple injections. The goal of this study was, therefore, to elucidate the role of the PEG layer in circulation persistence of MBs in the naïve animal (prior to an adaptive immune response). Here, we directly observe the number and size of individual MBs obtained from blood samples, unifying size and concentration into the microbubble volume dose (MVD) parameter. This approach enables direct evaluation of the pharmacokinetics of intact MBs, comprising both the lipid shell and gaseous core, rather than separately assessing the lipid or gas components. We examined the in vivo circulation persistence of 3 µm diameter phospholipid-coated MBs with three different mPEG2000 content: 2 mol % (mushroom), 5 mol % (intermediate), and 10 mol % (brush). MB size and concentration in the blood were evaluated by a hemocytometer analysis over 30 min following intravenous injections of 20 and 40 µL/kg MVD in Sprague-Dawley rats. Interestingly, pharmacokinetic analysis demonstrated that increasing PEG concentration on the MB surface resulted in faster clearance. This was evidenced by a 1.6-fold reduction in half-life and area under the curve (AUC) (p < 0.05) in the central compartment. Conversely, the AUC in the peripheral compartment increased with PEG density, suggesting enhanced MB trapping by the mononuclear phagocyte system. This was supported by an in vitro assay, which showed a significant rise in complement C3a activation with a higher PEG content. In conclusion, a minimal PEG concentration on the MB shell (mushroom configuration) was found to prolong circulation and mitigate immunogenicity.


Assuntos
Microbolhas , Polietilenoglicóis , Polietilenoglicóis/química , Polietilenoglicóis/farmacocinética , Animais , Fosfolipídeos/química , Ratos , Masculino , Ratos Sprague-Dawley
2.
J Control Release ; 365: 412-421, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38000663

RESUMO

Diffuse midline gliomas (DMGs), including diffuse intrinsic pontine glioma, have among the highest mortality rates of all childhood cancers, despite recent advancements in cancer therapeutics. This is partly because, unlike some CNS tumors, the blood-brain barrier (BBB) of DMG tumor vessels remains intact. The BBB prevents the permeation of many molecular therapies into the brain parenchyma, where the cancer cells reside. Focused ultrasound (FUS) with microbubbles has recently emerged as an innovative and exciting technology that non-invasively permeabilizes the BBB in a small focal region with millimeter precision. In this review, current treatment methods and biological barriers to treating DMGs are discussed. State-of-the-art FUS-mediated BBB opening is then examined, with a focus on the effects of various ultrasound parameters and the treatment of DMGs.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Criança , Barreira Hematoencefálica , Sistemas de Liberação de Medicamentos , Encéfalo/patologia , Neoplasias Encefálicas/terapia , Neoplasias Encefálicas/tratamento farmacológico , Glioma/diagnóstico por imagem , Glioma/terapia , Glioma/patologia , Microbolhas
3.
Neurooncol Adv ; 5(1): vdad111, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795179

RESUMO

Background: Diffuse intrinsic pontine glioma (DIPG) is the most common and deadliest pediatric brainstem tumor and is difficult to treat with chemotherapy in part due to the blood-brain barrier (BBB). Focused ultrasound (FUS) and microbubbles (MBs) have been shown to cause BBB opening, allowing larger chemotherapeutics to enter the parenchyma. Panobinostat is an example of a promising in vitro agent in DIPG with poor clinical efficacy due to low BBB penetrance. In this study, we hypothesized that using FUS to disrupt the BBB allows higher concentrations of panobinostat to accumulate in the tumor, providing a therapeutic effect. Methods: Mice were orthotopically injected with a patient-derived diffuse midline glioma (DMG) cell line, BT245. MRI was used to guide FUS/MB (1.5 MHz, 0.615 MPa peak negative pressure, 1 Hz pulse repetition frequency, 10-ms pulse length, 3 min treatment time)/(25 µL/kg, i.v.) targeting to the tumor location. Results: In animals receiving panobinostat (10 mg/kg, i.p.) in combination with FUS/MB, a 3-fold increase in tumor panobinostat concentration was observed, without significant increase of the drug in the forebrain. In mice receiving 3 weekly treatments, the combination of panobinostat and FUS/MB led to a 71% reduction of tumor volumes (P = .01). Furthermore, we showed the first survival benefit from FUS/MB improved delivery increasing the mean survival from 21 to 31 days (P < .0001). Conclusions: Our study demonstrates that FUS-mediated BBB disruption can increase the delivery of panobinostat to an orthotopic DMG tumor, providing a strong therapeutic effect and increased survival.

5.
Intensive Care Med Exp ; 11(1): 35, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37357222

RESUMO

Inhalation injury can lead to pulmonary complications resulting in the development of respiratory distress and severe hypoxia. Respiratory distress is one of the major causes of death in critically ill patients with a reported mortality rate of up to 45%. The present study focuses on the effect of oxygen microbubble (OMB) infusion via the colon in a porcine model of smoke inhalation-induced lung injury. Juvenile female Duroc pigs (n = 6 colonic OMB, n = 6 no treatment) ranging from 39 to 51 kg in weight were exposed to smoke under general anesthesia for 2 h. Animals developed severe hypoxia 48 h after smoke inhalation as reflected by reduction in SpO2 to 66.3 ± 13.1% and PaO2 to 45.3 ± 7.6 mmHg, as well as bilateral diffuse infiltrates demonstrated on chest X-ray. Colonic OMB infusion (75-100 mL/kg dose) resulted in significant improvements in systemic oxygenation as demonstrated by an increase in PaO2 of 13.2 ± 4.7 mmHg and SpO2 of 15.2 ± 10.0% out to 2.5 h, compared to no-treatment control animals that experienced a decline in PaO2 of 8.2 ± 7.9 mmHg and SpO2 of 12.9 ± 18.7% over the same timeframe. Likewise, colonic OMB decreased PaCO2 and PmvCO2 by 19.7 ± 7.6 mmHg and 7.6 ± 6.7 mmHg, respectively, compared to controls that experienced increases in PaCO2 and PmvCO2 of 17.9 ± 11.7 mmHg and 18.3 ± 11.2 mmHg. We conclude that colonic delivery of OMB therapy has potential to treat patients experiencing severe hypoxemic respiratory failure.

6.
Ultrasound Med Biol ; 49(8): 1861-1866, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37246050

RESUMO

OBJECTIVE: For the treatment of tumor hypoxia, microbubbles comprising oxygen as a majority component of the gas core with a stabilizing shell may be used to deliver and release oxygen locally at the tumor site through ultrasound destruction. Previous work has revealed differences in circulation half-life in vivo for perfluorocarbon-filled microbubbles, typically used as ultrasound imaging contrast agents, as a function of anesthetic carrier gas. These differences in circulation time in vivo were likely due to gas diffusion as a function of anesthetic carrier gas, among other variables. This work has motivated studies to evaluate the effect of anesthetic carrier gas on oxygen microbubble circulation dynamics. METHODS: Circulation time for oxygen microbubbles was derived from ultrasound image intensity obtained during longitudinal kidney imaging. Studies were constructed for rats anesthetized on inhaled isoflurane with either pure oxygen or medical air as the anesthetic carrier gas. RESULTS: Results indicated that oxygen microbubbles were highly visible via contrast-specific imaging. Marked signal enhancement and duration differences were observed between animals breathing air and oxygen. Perhaps counterintuitively, oxygen microbubbles disappeared from circulation significantly faster when the animals were breathing pure oxygen compared with medical air. This may be explained by nitrogen counterdiffusion from blood into the bubble, effectively changing the gas composition of the core, as has been observed in perfluorocarbon core microbubbles. CONCLUSION: Our findings suggest that the apparent longevity and persistence of oxygen microbubbles in circulation may not be reflective of oxygen delivery when the animal is anesthetized breathing air.


Assuntos
Anestésicos , Fluorocarbonos , Ratos , Animais , Oxigênio , Fosfolipídeos , Microbolhas , Ultrassonografia , Meios de Contraste
7.
bioRxiv ; 2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37066205

RESUMO

Diffuse intrinsic pontine glioma (DIPG) is the most common and deadliest pediatric brainstem tumor and is difficult to treat with chemotherapy in part due to the blood-brain barrier (BBB). Focused ultrasound (FUS) and microbubbles (MBs) have been shown to cause BBB disruption (BBBD), allowing larger chemotherapeutics to enter the parenchyma. Panobinostat is an example of a promising in vitro agent in DIPG with poor clinical efficacy due to low BBB penetrance. In this study, we hypothesized that using FUS to disrupt the BBB allows higher concentrations of panobinostat to accumulate in the tumor, providing a therapeutic effect. Mice were orthotopically injected with a patient-derived DMG cell line, BT-245. MRI was used to guide FUS/MB (1.5 MHz, 0.615 MPa PNP, 1 Hz PRF, 10 ms PL, 3 min treatment time) / (25 µL/kg, IV) targeting to the tumor location. In animals receiving panobinostat (10 mg/kg, IP) in combination with FUS/MB, a 3-fold increase in tumor panobinostat concentration was observed, with only insignificant increase of the drug in the forebrain. In mice receiving three weekly treatments, the combination of panobinostat and FUS/MB led to a 71% reduction of tumor volumes by MRI ( p = 0.01). Furthermore, FUS/MB improved the mean survival from 21 to 31 days ( p < 0.0001). Our study demonstrates that FUS-mediated BBBD can increase the delivery of panobinostat to an orthotopic DMG tumor, providing a strong therapeutic effect and increased survival. One Sentence Summary: FUS and microbubbles can increase the delivery of panobinostat to a patient-derived xenograft (PDX) orthotopic DMG tumor, providing a strong therapeutic effect and increased survival.

8.
Bioconjug Chem ; 33(6): 1106-1113, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35476906

RESUMO

Microbubbles (1-10 µm diameter) have been used as conventional ultrasound contrast agents (UCAs) for applications in contrast-enhanced ultrasound (CEUS) imaging. Nanobubbles (<1 µm diameter) have recently been proposed as potential extravascular UCAs that can extravasate from the leaky vasculature of tumors or sites of inflammation. However, the echogenicity of nanobubbles for CEUS remains controversial owing to prior studies that have shown very low ultrasound backscatter. We hypothesize that microbubble contamination in nanobubble formulations may explain the discrepancy. To test our hypothesis, we examined the size distributions of lipid-coated nanobubble and microbubble suspensions using multiple sizing techniques, examined their echogenicity in an agar phantom with fundamental-mode CEUS at 7 MHz and 330 kPa peak negative pressure, and interpreted our results with simulations of the modified Rayleigh-Plesset model. We found that nanobubble formulations contained a small contamination of microbubbles. Once the contribution from these microbubbles is removed from the acoustic backscatter, the acoustic contrast of the nanobubbles was shown to be near noise levels. This result indicates that nanobubbles have limited utility as UCAs for CEUS.


Assuntos
Microbolhas , Neoplasias , Acústica , Meios de Contraste , Humanos , Ultrassonografia/métodos
9.
Theranostics ; 10(18): 8143-8161, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32724463

RESUMO

Neuroblastoma (NB) is the most common extracranial solid tumor in infants and children, and imposes significant morbidity and mortality in this population. The aggressive chemoradiotherapy required to treat high-risk NB results in survival of less than 50%, yet is associated with significant long-term adverse effects in survivors. Boosting efficacy and reducing morbidity are therefore key goals of treatment for affected children. We hypothesize that these may be achieved by developing strategies that both focus and limit toxic therapies to the region of the tumor. One such strategy is the use of targeted image-guided drug delivery (IGDD), which is growing in popularity in personalized therapy to simultaneously improve on-target drug deposition and assess drug pharmacodynamics in individual patients. IGDD strategies can utilize a variety of imaging modalities and methods of actively targeting pharmaceutical drugs, however in vivo imaging in combination with focused ultrasound is one of the most promising approaches already being deployed for clinical applications. Over the last two decades, IGDD using focused ultrasound with "microbubble" ultrasound contrast agents (UCAs) has been increasingly explored as a method of targeting a wide variety of diseases, including cancer. This technique, known as sonopermeation, mechanically augments vascular permeability, enabling increased penetration of drugs into target tissue. However, to date, methods of monitoring the vascular bioeffects of sonopermeation in vivo are lacking. UCAs are excellent vascular probes in contrast-enhanced ultrasound (CEUS) imaging, and are thus uniquely suited for monitoring the effects of sonopermeation in tumors. Methods: To monitor the therapeutic efficacy of sonopermeation in vivo, we developed a novel system using 2D and 3D quantitative contrast-enhanced ultrasound imaging (qCEUS). 3D tumor volume and contrast enhancement was used to evaluate changes in blood volume during sonopermeation. 2D qCEUS-derived time-intensity curves (TICs) were used to assess reperfusion rates following sonopermeation therapy. Intratumoral doxorubicin (and liposome) uptake in NB was evalauted ex vivo along with associated vascular changes. Results: In this study, we demonstrate that combining focused ultrasound therapy with UCAs can significantly enhance chemotherapeutic payload to NB in an orthotopic xenograft model, by improving delivery and tumoral uptake of long-circulating liposomal doxorubicin (L-DOX) nanoparticles. qCEUS imaging suggests that changes in flow rates are highly sensitive to sonopermeation and could be used to monitor the efficacy of treatment in vivo. Additionally, initial tumor perfusion may be a good predictor of drug uptake during sonopermeation. Following sonopermeation treatment, vascular biomarkers show increased permeability due to reduced pericyte coverage and rapid onset of doxorubicin-induced apoptosis of NB cells but without damage to blood vessels. Conclusion: Our results suggest that significant L-DOX uptake can occur by increasing tumor vascular permeability with microbubble sonopermeation without otherwise damaging the vasculature, as confirmed by in vivo qCEUS imaging and ex vivo analysis. The use of qCEUS imaging to monitor sonopermeation efficiency and predict drug uptake could potentially provide real-time feedback to clinicians for determining treatment efficacy in tumors, leading to better and more efficient personalized therapies. Finally, we demonstrate how the IGDD strategy outlined in this study could be implemented in human patients using a single case study.


Assuntos
Doxorrubicina/análogos & derivados , Microbolhas , Neuroblastoma/tratamento farmacológico , Imagem de Perfusão/métodos , Ultrassonografia de Intervenção/métodos , Animais , Apoptose/efeitos dos fármacos , Determinação do Volume Sanguíneo/instrumentação , Determinação do Volume Sanguíneo/métodos , Permeabilidade Capilar/efeitos da radiação , Linhagem Celular Tumoral , Meios de Contraste/administração & dosagem , Doxorrubicina/administração & dosagem , Doxorrubicina/farmacocinética , Sistemas de Liberação de Medicamentos/métodos , Estudos de Viabilidade , Humanos , Camundongos , Neuroblastoma/irrigação sanguínea , Neuroblastoma/diagnóstico por imagem , Técnicas Fotoacústicas/instrumentação , Técnicas Fotoacústicas/métodos , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/farmacocinética , Estudos de Caso Único como Assunto , Ondas Ultrassônicas , Ultrassonografia de Intervenção/instrumentação , Ensaios Antitumorais Modelo de Xenoenxerto
10.
J Spine Surg ; 6(1): 49-61, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32309645

RESUMO

BACKGROUND: A retrospective clinical case series study was conducted to evaluate the use of a novel, spherical bioactive glass bone graft (BioSphere Putty) as a graft material for cervical and lumbar interbody fusion. METHODS: Data was collected from a single surgeon using BioSphere Putty along with standardized hardware in anterior cervical decompression and fusion (ACDF), transforaminal lumbar interbody fusion (TLIF), and anterior lumbar interbody fusion (ALIF) surgical procedures. BioSphere Putty was used in combination with cancellous allograft (ACDF and ALIF) or in combination with autograft (TLIF). Clinical outcomes were assessed at 1- and 2-year using radiographic imaging and the visual analog pain scale (VAS). VAS scores at the 1- and 2-year follow-up periods were statistically compared to pre-operative scoring. Successful clinical outcomes were determined by a combination of the presence of a complete radiographic fusion and a decrease in VAS at 1-year and 1- and 2-year follow-up periods. RESULTS: The retrospective review of the patient data identified 248 cases that had either 1- or 1- & 2-year follow-up. This consisted of 115 ACDF procedures and 133 lumbar fusion procedures. Lumbar fusion cases were further sub-grouped with 103 patients undergoing TLIF procedures and 30 patients undergoing ALIF procedures. The global results for the series as a whole showed clinical outcomes comparative to other advanced biologic bone grafts. Radiographically all patients demonstrated fusion (100% fusion rate) and there were no clinical adverse events, infections, or graft-related complications in any of the patients in the series. One-year VAS scores were consistent with historical norms and demonstrated significant decreases in pre-operative pain for both ACDF patients (78% decrease) and lumbar patients (66% decrease TLIF/ALIF) (t test, P<0.05). By 2 years, VAS scores continued to drop with significant decreases for the ACDF patients (96%), TLIF patients (82%), and ALIF patients (80%) (t test, P<0.05). VAS scores were also assessed for each individual patient. The data showed a VAS score decrease from pre-operative levels in 93% of the ACDF patients and 89% of the lumbar patients. Combined with the 100% radiographic fusion rate in all patients, this resulted in a in a clinical success rate of 93% for the ACDF patients and 89% for the lumbar patients. CONCLUSIONS: The results of this clinical case series demonstrated that BioSphere Putty is a clinically effective and versatile synthetic bone graft material in the spine.

11.
Nanotheranostics ; 4(2): 83-90, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32190535

RESUMO

In recent work, oxygen microbubbles (OMB) have been shown to oxygenate hypoxic tumors, increase radio-sensitivity and improve tumor control by radiation therapy. Compared to intra-tumoral injection, intravenous delivery of adjuvant agents such as OMBs for radiotherapy offers an attractive means of achieving true theranostic function in a minimally invasive manner via contrast-enhanced ultrasound (CEUS), while reducing the risk of injury, infection or displacing tumor cells. However, short intravascular circulation times with conventional DSPC-lipid OMBs may lead to premature off-target dissolution of OMBs with an associated reduction in tumoral oxygen delivery. Prior work on microbubble stability and gas exchange suggests that increasing phospholipid acyl-chain length of the encapsulating shell and OMB size may increase circulation persistence, delivery and dissolved oxygen content. In the following studies, we investigate the effect of two phospholipid shell compositions, DSPC (C18:0) and DBPC (C22:0), as well as three size distributions (0.5-2 µm, 2-10 µm and polydisperse) on OMB circulation persistence utilizing CEUS in the kidneys of live C57B1/6 male and female mice, six weeks of age. DBPC OMB formulations demonstrated increased circulation half-lives versus DSPC formulations (2.4 ± 1.0 vs. 0.6 ± 0.5 s, p<0.01 for 2-10 µm), as well as an increased maximum intensity by over tenfold (p<0.01). Size-dependent effects remained consistent across both formulations with larger 2-10 µm microbubbles demonstrating significantly increased half-lives (2.4 ± 1.0 vs. 0.3 ± 0.2 s, p < 0.01) compared to smaller 0.5-2 µm formulations of DBPC. These studies indicate that DBPC 2-10 µm OMBs may be improved adjuvant agents for radiotherapy with significant potential for CEUS interrogation.


Assuntos
Microbolhas , Oxigênio , Fosfolipídeos , Radioterapia Guiada por Imagem/métodos , Ultrassonografia/métodos , Animais , Meios de Contraste/química , Meios de Contraste/farmacocinética , Feminino , Rim/diagnóstico por imagem , Rim/metabolismo , Masculino , Camundongos , Oxigênio/química , Oxigênio/farmacocinética , Fosfolipídeos/química , Fosfolipídeos/farmacocinética
12.
Ultrasound Med Biol ; 46(6): 1326-1343, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32169397

RESUMO

Microbubble ultrasound contrast agents have now been in use for several decades and their safety and efficacy in a wide range of diagnostic applications have been well established. Recent progress in imaging technology is facilitating exciting developments in techniques such as molecular, 3-D and super resolution imaging and new agents are now being developed to meet their specific requirements. In parallel, there have been significant advances in the therapeutic applications of microbubbles, with recent clinical trials demonstrating drug delivery across the blood-brain barrier and into solid tumours. New agents are similarly being tailored toward these applications, including nanoscale microbubble precursors offering superior circulation times and tissue penetration. The development of novel agents does, however, present several challenges, particularly regarding the regulatory framework. This article reviews the developments in agents for diagnostic, therapeutic and "theranostic" applications; novel manufacturing techniques; and the opportunities and challenges for their commercial and clinical translation.


Assuntos
Meios de Contraste , Microbolhas , Ultrassonografia/métodos , Animais , Sistemas de Liberação de Medicamentos/métodos , Humanos , Microfluídica , Imagem Multimodal , Nanomedicina Teranóstica , Terapia por Ultrassom/métodos
13.
Med Phys ; 47(3): 1280-1290, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31828781

RESUMO

PURPOSE: Three-dimensional in-vivo dose verification is one of the standing challenges in radiation therapy. X-ray-induced acoustic tomography has recently been proposed as an imaging method for use in in-vivo dosimetry. The aim of this study was to investigate the accuracy of reconstructing three-dimensional (3D) absolute dose using x-ray-induced acoustic tomography. We performed this investigation using two different tomographic dose reconstruction techniques. METHODS: Two examples of 3D dose reconstruction techniques for x-ray acoustic imaging are investigated. Dose distributions are calculated for varying field sizes using a clinical treatment planning system. The induced acoustic pressure waves which are generated by the increase in temperature due to the absorption of pulsed MV x-rays are simulated using an advanced numerical modeling package for acoustic wave propagation in the time domain. Two imaging techniques, back projection and iterative time reversal, are used to reconstruct the 3D dose distribution in a water phantom with open fields. Image analysis is performed and reconstructed depth dose curves from x-ray acoustic imaging are compared to the depth dose curves calculated from the treatment planning system. Calculated field sizes from the reconstructed dose profiles by back projection and time reversal are compared to the planned field size to determine their accuracy. The iterative time reversal imaging technique is also used to reconstruct dose in an example clinical dose distribution. Image analysis of this clinical test case is performed using the gamma passing rate. In addition, gamma passing rates are used to validate the stopping criteria in the iterative time reversal method. RESULTS: Water phantom simulations showed that back projection does not adequately reconstruct the shape and intensity of the depth dose. When compared to the depth of maximum dose calculated by a treatment planning system, the maximum dose depth by back projection is shifted deeper by 55 and 75 mm for 4 × 4 cm and 10 × 10 cm field sizes, respectively. The reconstructed depth dose by iterative time reversal accurately agrees with the planned depth dose for a 4 × 4 cm field size and is shifted deeper by 12 mm for the 10 × 10 cm field size. When reconstructing field sizes, the back projection method leads to 18% and 35% larger sizes for the 4 × 4 cm and 10 × 10 cm fields, respectively, whereas the iterative time reversal method reconstructs both field sizes with < 2% error. For the clinical dose distribution, we were able to reconstruct the dose delivered by a 1 degree sub-arc with a good accuracy. The reconstructed and planned doses were compared using gamma analysis, with> 96% gamma passing rate at 3%/2 mm. CONCLUSIONS: Our results show that the 3D x-ray acoustic reconstructed dose by iterative time reversal is considerably more accurate than the dose reconstructed by back projection. Iterative time reversal imaging has a potential for use in 3D absolute dosimetry.


Assuntos
Acústica/instrumentação , Simulação por Computador , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Fatores de Tempo
14.
Artigo em Inglês | MEDLINE | ID: mdl-31449011

RESUMO

Due to the primary radiation force, microbubble displacement has been observed previously in the focal region of single-element and array ultrasound probes. This effect has been harnessed to increase the contact between the microbubbles and targeted endothelium for drug delivery and ultrasound molecular imaging. In this study, microbubble displacements associated with plane-wave (PW) transmission are thoroughly investigated and compared to those obtained in focused-wave (FW) transmission over a range of pulse repetition frequencies, burst lengths (BLs), peak negative pressures, and transmission frequencies. In PW mode, the displacements, depending upon the experimental conditions, are in some cases consistently higher (e.g., by 28%, when the longest BL was used at PRF = 4 kHz), and the axial displacements are spatially more uniform compared to FW mode. Statistical analysis on the measured displacements reveals a slightly different frequency dependence of statistical quantities compared to transient peak microbubble displacements, which may suggest the need to consider the size range within the tested microbubble population.


Assuntos
Meios de Contraste/química , Microbolhas , Ultrassonografia/métodos , Imagem Molecular/métodos , Transdutores , Ultrassonografia/instrumentação
15.
Nanotheranostics ; 3(2): 212-222, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31183315

RESUMO

The highly tunable, noninvasive and spatially targeted nature of microbubble-enhanced, ultrasound-guided (MB+US) drug delivery makes it desirable for a wide variety of therapies. In breast cancer, both HER2+ and HER2- type neoplasms pose significant challenges to conventional therapeutics in greater than 40% of breast cancer patients, even with the widespread application of biologics such as trastuzumab. To address this therapeutic challenge, we examined the novel combination of tumor-injected microbubble-bound siRNA complexes and monodisperse size-isolated microbubbles (4-µm diameter) to attenuate tumor growth in vivo, as well as MB+US-facilitated shRNA and siRNA knockdown of ESE-1, an effector linked to dysregulated HER2 expression in HER2+/- cell line propagation. We first screened six variants of siESE and shESE for efficient knockdown of ESE in breast cancer cell lines. We demonstrated efficient reduction of BT-474 (PR+, ER+, HER2+; luminal B) and MDA-MB-468 (PR-, ER-, HER2-; triple-negative) clonogenicity and non-adherent growth after knockdown of ESE-1. A significant reduction in proliferative potential was seen for both cell lines using MB+US to deliver shESE and siESE. We then demonstrated significant attenuation of BT-474 xenograft tumor growth in Nod/SCID female mice using direct injection of microbubble-adsorbed siESE to the tumor and subsequent sonication. Our results suggest a positive effect on drug delivery from MB+US, and highlights the feasibility of using RNAi and MB+US for breast cancer pathologies. RNAi coupled with MB+US may also be an effective theranostic approach to treat other acoustically accessible tumors, such as melanoma, thyroid, parotid and skin cancer.


Assuntos
Neoplasias da Mama , Microbolhas , Receptor ErbB-2/metabolismo , Ondas Ultrassônicas , Animais , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Feminino , Humanos , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Trastuzumab/farmacologia , Ensaios Antitumorais Modelo de Xenoenxerto
16.
Drug Deliv ; 26(1): 147-157, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30822171

RESUMO

Hypoxic pulmonary vasoconstriction (HPV) is a well-characterized vascular response to low oxygen pressures and is involved in life-threatening conditions such as high-altitude pulmonary edema (HAPE) and pulmonary arterial hypertension (PAH). While the efficacy of oral therapies can be affected by drug metabolism, or dose-limiting systemic toxicity, inhaled treatment via pressured metered dose inhalers (pMDI) may be an effective, nontoxic, practical alternative. We hypothesized that a stable water-in-perfluorooctyl bromide (PFOB) emulsion that provides solubility in common pMDI propellants, engineered for intrapulmonary delivery of pulmonary vasodilators, reverses HPV during acute hypoxia (HX). Male Sprague Dawley rats received two 10-min bouts of HX (13% O2) with 20 min of room air and drug application between exposures. Treatment groups: intrapulmonary delivery (PUL) of (1) saline; (2) ambrisentan in saline (0.1 mg/kg); (3) empty emulsion; (4) emulsion encapsulating ambrisentan or sodium nitrite (NaNO2) (0.1 and 0.5 mg/kg each); and intravenous (5) ambrisentan (0.1 mg/kg) or (6) NaNO2 (0.5 mg/kg). Neither PUL of saline or empty emulsion, nor infusions of drugs prevented pulmonary artery pressure (PAP) elevation (32.6 ± 3.2, 31.5 ± 1.2, 29.3 ± 1.8, and 30.2 ± 2.5 mmHg, respectively). In contrast, PUL of aqueous ambrisentan and both drug emulsions reduced PAP by 20-30% during HX, compared to controls. IL6 expression in bronchoalveolar lavage fluid and whole lung 24 h post-PUL did not differ among cohorts. We demonstrate proof-of-concept for delivering pulmonary vasodilators via aerosolized water-in-PFOB emulsion. This concept opens a potentially feasible and effective route of treating pulmonary vascular pathologies via pMDI.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Emulsões/administração & dosagem , Fluorocarbonos/administração & dosagem , Hipertensão Pulmonar/tratamento farmacológico , Edema Pulmonar/tratamento farmacológico , Água/administração & dosagem , Animais , Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/metabolismo , Avaliação Pré-Clínica de Medicamentos/métodos , Emulsões/metabolismo , Fluorocarbonos/metabolismo , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/metabolismo , Masculino , Fenilpropionatos/administração & dosagem , Fenilpropionatos/metabolismo , Circulação Pulmonar/efeitos dos fármacos , Circulação Pulmonar/fisiologia , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/metabolismo , Piridazinas/administração & dosagem , Piridazinas/metabolismo , Ratos , Ratos Sprague-Dawley , Resultado do Tratamento , Água/metabolismo
17.
Theranostics ; 8(16): 4393-4408, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30214628

RESUMO

Focused ultrasound with microbubbles promises unprecedented advantages for blood-brain barrier disruption over existing intracranial drug delivery methods, as well as a significant number of tunable parameters that affect its safety and efficacy. This review provides an engineering perspective on the state-of-the-art of the technology, considering the mechanism of action, effects of microbubble properties, ultrasound parameters and physiological variables, as well as safety and potential therapeutic applications. Emphasis is placed on the use of unified parameters, such as microbubble volume dose (MVD) and ultrasound mechanical index, to optimize the procedure and establish safety limits. It is concluded that, while efficacy has been demonstrated in several animal models with a wide range of payloads, acceptable measures of safety should be adopted to accelerate collaboration and improve understanding and clinical relevance.


Assuntos
Barreira Hematoencefálica/efeitos da radiação , Sistemas de Liberação de Medicamentos/métodos , Microbolhas , Ondas Ultrassônicas , Ultrassonografia/efeitos adversos , Ultrassonografia/métodos , Animais , Humanos , Modelos Animais
18.
Artigo em Inglês | MEDLINE | ID: mdl-29994658

RESUMO

Radiation force is known to produce microbubble axial displacements by an amount that depends on the transmit burst frequency, amplitude, and length, as well as the pulse repetition frequency (PRF). In the standard focused-imaging mode, the actual PRF experienced by each microbubble is low, because it is of the order of the frame rate (i.e., usually tens of Hertz). In the plane-wave imaging mode, however, the actual PRF is considerably higher, as it is equivalent to the transmit PRF (kiloHertz range). Furthermore, the radiation pressure is expected to be almost uniform over the field of view, and typically lower than the peak pressure experienced in the focused transmit (TX) mode. We have experimentally investigated the possible effects of radiation force in the plane-wave mode. Here, we report on preliminary findings that show that the acoustic radiation force is negligible only at lower TX levels. At higher TX amplitudes, the bubble displacements due to radiation force are comparable to those obtained for focused waves at the same PRF. In addition, the radiation force is nearly uniform over the field of view and increases as the TX burst central frequency approaches the resonance frequency of size-isolated microbubbles.


Assuntos
Meios de Contraste/química , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Microbolhas
19.
Bioconjug Chem ; 29(5): 1534-1543, 2018 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-29614859

RESUMO

Interest in the use of targeted microbubbles for ultrasound molecular imaging (USMI) has been growing in recent years as a safe and efficacious means of diagnosing tumor angiogenesis and assessing response to therapy. Of particular interest are cloaked microbubbles, which improve specificity by concealing the ligand from blood components until they reach the target vasculature, where the ligand can be transiently revealed for firm receptor-binding by ultrasound acoustic radiation force pulses. Herein, a bio-orthogonal "click" conjugation chemistry is introduced to decorate the surface of cloaked 4-5-µm-diameter microbubbles as part of a sterile and reproducible production process. Azido-functionalized antagonists for the angiogenic biomarkers αVß3 integrin (cRGD) and VEGFR2 (A7R) proteins were conjugated to bimodal-brush microbubbles via strain-promoted [3 + 2] azide-alkyne cycloaddition (SPAAC) click chemistry. Ligand conjugation was validated by epifluorescent microscopy, flow cytometry, and Fourier-transform infrared spectroscopy. Sterility was validated by bacterial culture and endotoxin analysis. Additionally, clinically normal dogs receiving escalating microbubble doses were shown to experience no pathologic changes in physical examination, complete blood count, serum biochemistry profile, or coagulation panel. This bio-orthogonal microbubble conjugation process for cloaked peptide ligands may be leveraged for future USMI studies of tumor angiogenesis for translation to preclinical and clinical applications.


Assuntos
Química Click/métodos , Meios de Contraste/química , Microbolhas , Oligopeptídeos/química , Peptídeos Cíclicos/química , Alcinos/síntese química , Alcinos/química , Animais , Azidas/síntese química , Azidas/química , Meios de Contraste/síntese química , Reação de Cicloadição/métodos , Cães , Humanos , Integrina alfaVbeta3/análise , Ligantes , Modelos Moleculares , Neovascularização Patológica/diagnóstico por imagem , Oligopeptídeos/síntese química , Peptídeos Cíclicos/síntese química , Ultrassonografia/métodos , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/análise
20.
PLoS One ; 13(4): e0195667, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29630640

RESUMO

Cancer affects 39.6% of Americans at some point during their lifetime. Solid tumor microenvironments are characterized by a disorganized, leaky vasculature that promotes regions of low oxygenation (hypoxia). Tumor hypoxia is a key predictor of poor treatment outcome for all radiotherapy (RT), chemotherapy and surgery procedures, and is a hallmark of metastatic potential. In particular, the radiation therapy dose needed to achieve the same tumor control probability in hypoxic tissue as in normoxic tissue can be up to 3 times higher. Even very small tumors (<2-3 mm3) comprise 10-30% of hypoxic regions in the form of chronic and/or transient hypoxia fluctuating over the course of seconds to days. We investigate the potential of recently developed lipid-stabilized oxygen microbubbles (OMBs) to improve the therapeutic ratio of RT. OMBs, but not nitrogen microbubbles (NMBs), are shown to significantly increase dissolved oxygen content when added to water in vitro and increase tumor oxygen levels in vivo in a rat fibrosarcoma model. Tumor control is significantly improved with OMB but not NMB intra-tumoral injections immediately prior to RT treatment and effect size is shown to depend on initial tumor volume on RT treatment day, as expected.


Assuntos
Fibrossarcoma/radioterapia , Microbolhas/uso terapêutico , Oxigênio/uso terapêutico , Animais , Feminino , Fibrossarcoma/metabolismo , Humanos , Oxigênio/administração & dosagem , Oxigênio/metabolismo , Ratos , Ratos Endogâmicos F344 , Sarcoma Experimental/metabolismo , Sarcoma Experimental/radioterapia , Pesquisa Translacional Biomédica , Hipóxia Tumoral/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA