Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Diagn Interv Imaging ; 103(7-8): 360-366, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35183483

RESUMO

PURPOSE: The purpose of this study was to evaluate the capabilities of radiomics using magnetic resonance imaging (MRI) data in the assessment of treatment response to 90yttrium transarterial radioembolization (TARE) in patients with locally advanced hepatocellular carcinoma (HCC) by comparison with predictions based on European Association for the Study of the Liver (EASL) criteria. PATIENTS AND METHODS: Twenty-two patients with HCC (19 men, 3 women; mean age: 66.7 ± 9.8 [SD]; age range: 37-82 years) who underwent contrast-enhanced MRI 4 ± 1 weeks before and 4 ± 4 weeks after TARE, were enrolled in this retrospective study. Regions of interest were placed manually along the contours of the treated tumor on each axial slice of arterial and portal phase images using the ITK-SNAP post-processing software. For each MRI, the Pyradiomics Python package was used to extract 107 radiomics features on both arterial and portal phases, and resulting delta-features were computed. The Mann-Whitney U test with Bonferroni correction was used to select statistically different features between responders and non-responders (i.e., those with progressive or stable disease) at 6-month follow-up, according to the modified Response Evaluation Criteria in Solid Tumors (mRECIST). Finally, for each selected feature, univariable logistic regression with leave-one-out cross validation procedure was used to perform receiver operating characteristic (ROC) curve analysis and compare radiomics parameters with MRI variables. RESULTS: According to mRECIST, 14 patients (14/22; 64%) were non-responders and 8 (8/22; 36%) were responders. Four radiomics parameters (long run emphasis, minor axis length, surface area, and gray level non-uniformity on arterial phase images) were the only predictors of early response. ROC curve analysis showed that long run emphasis was the best parameter for predicting early response, with 100% sensitivity (95% CI: 68-100) and 100% specificity (95% CI: 78-100). EASL morphologic criteria yielded 75% sensitivity (95% CI: 41-96%) and 93% specificity (95% CI: 69-100%). CONCLUSION: Radiomics allows identify marked differences between responders and non-responders, and could aid in the prediction of early treatment response following TARE in patients with HCC.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
Clin Nucl Med ; 46(12): 958-964, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34507332

RESUMO

PURPOSE: Selective internal radiotherapy with 90Y microspheres is widely used for the treatment of patients with liver cancer. A dosimetric analysis using the dosimetry software Simplicit90y (Boston Scientific, Natick, MA) was conducted to define doses to the tumor and healthy liver, and to determine a threshold tumor dose that could predict progression-free survival. METHODS: Patients experiencing hepatocellular carcinoma and treated with 90Y-labeled resin microspheres were included in a retrospective study. The time-to-progression of the target lesions (TTPLs) and overall survival (OS) were evaluated using Kaplan-Meier tests, and this comparison was based on a log-rank test. RESULTS: Twenty-four procedures for patients with portal vein thrombosis were realized. Median follow-up was 16 months. A threshold tumor dose of 125 Gy was determined with a sensitivity of 89% and a specificity of 100%. For patients with a tumor dose of less than 125 Gy, the median OS was 7.5 months (95% confidence interval [CI], 5-14 months) and the TTPL was 3 months (95% CI, 2-6 months) versus 33 months (95% CI, 22-39 months) and 23 months (95% CI, 7-38 months), respectively, for those with a tumor dose of 125 Gy or more (P = 0.002 and P = 0.0004). CONCLUSIONS: Personalized dosimetry based on 99mTc-MAA SPECT/CT is predictive of TTPL and OS in patients with hepatocellular carcinoma. Customized dosimetry software is essential to optimize treatment planning.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/radioterapia , Humanos , Neoplasias Hepáticas/radioterapia , Microesferas , Estudos Retrospectivos , Radioisótopos de Ítrio/uso terapêutico
3.
Cancers (Basel) ; 13(8)2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33923781

RESUMO

To compare the prognostic values of 18-FDG PET/CT (FDG-PET) and Whole-Body MRI with Diffusion-Weighted Imaging (WB-DW-MRI) in the evaluation of treatment response of Multiple Myeloma (MM) patients eligible for ASCT. Thirty patients with newly diagnosed MM prospectively underwent FDG-PET and WB-DW-MRI at baseline, after induction chemotherapy and after ASCT. Response on WB-DW-MRI was evaluated with the MY-RADS criteria. FDG-PET was considered positive if residual uptake was superior to liver uptake. Imaging results were not used for treatment modification. The impact of imaging results on PFS was analyzed. After a median follow-up of 32 months, 10 patients relapsed. With WB-DW-MRI, post-induction examination was positive in 3/25 and post-ASCT examination was positive in 3/27 patients. However, neither study showed prognostic impact on PFS. FDG-PET was positive in 5/22 post-induction and 3/26 patients post-ASCT, respectively. Positivity of FDG-PET, post-induction or post-ASCT, was associated with a shorter PFS (post-induction: median PFS 19 months vs. not reached, log-rank p = 0.0089; post-ASCT: median PFS 18 months vs. not reached, log-rank p = 0.0005). Preliminary results from this small, single-center, prospective study show that, whether performed post-induction or post-ASCT, FDG-PET has a higher prognostic value than WB-DW-MRI for treatment response evaluation of newly diagnosed MM.

4.
Nucl Med Commun ; 42(6): 633-638, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33660694

RESUMO

BACKGROUND: Transarterial radioembolization (TARE) is widely used for the treatment of hepatocellular carcinoma (HCC), but early treatment response can be very difficult to assess. The aim was to evaluate 18F-fluorocholine PET/computed tomography (CT) to assess the treatment response in patients with intermediate or locally advanced HCC. METHODS: Between March 2019 and July 2020, nine HCC patients treated with TARE, who underwent PET/CT at baseline and 1 month after treatment, were enrolled. The maximum, mean (SUVmean), and peak (SUVpeak) standardized uptake value (SUV), SUV normalized by lean body mass (SUL), and total lesion glycolysis (TLG) were measured. Statistical analysis used the Mann-Whitney test to evaluate the differences in parameters between responders (partial and complete response) and nonresponders (stable or progressive disease) at the 6-month follow-up, according to the modified Response Evaluation Criteria in Solid Tumors. RESULTS: Three patients were nonresponders (progressive disease and stable disease) and six were responders. Delta SUVmean, delta SUL, and delta TLG could predict an early response (P = 0.02, P = 0.04, and P = 0.02, respectively). None of the pre-therapeutic parameters were correlated with the response. Post-therapeutic SUL, SUVmean, TLG, and SUVpeak were also predictive of the response. CONCLUSIONS: Our preliminary results showed that changes in certain metabolic parameters (from baseline PET to 1-month PET) are predictive of the response to TARE in HCC (Delta SUVmean, delta TLG, and delta SUL). The absence of post-treatment inflammation could lead to a better prediction than MRI evaluation. This study suggests that 1-month 18F-choline PET/CT could modify the clinical management predicting responders.Video Abstract: http://links.lww.com/NMC/A193.


Assuntos
Carcinoma Hepatocelular , Colina/análogos & derivados , Neoplasias Hepáticas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Embolização Terapêutica , Glicólise , Humanos , Masculino , Pessoa de Meia-Idade
5.
Facial Plast Surg Aesthet Med ; 23(5): 321-329, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-32700976

RESUMO

Importance: A validated biomaterial would have several medical advantages in septorhinoplasties requiring a large-volume graft such as avoiding donor site morbidity, making ambulatory surgery possible, and reducing surgical costs. Objective: To assess the safety and efficacy of a ceramic to treat saddle and crooked noses. The main endpoint was the biocompatibility of the implant. The secondary endpoint was its functional and aesthetic efficacy. Design, Setting, and Participants: The nasal septum (NASEPT) study is a pilot multicenter noncomparative prospective phase IIa clinical trial. The biomaterial tested was a biphasic calcium phosphate implant composed of 75% hydroxyapatite and 25% beta tri calcium phosphate. This versatile material can be used to replace septal skeleton when it is absent or nonusable. We included 25 patients with a multifractured osseous and cartilaginous framework after several traumas or surgeries. The implant placement technique was identical to an extracorporeal septoplasty through the external approach. Main Outcomes and Measures: The primary endpoint was the occurrence of expected adverse and severe adverse events. The secondary endpoints were clinical functional and aesthetic results and histological microscopic modifications. Results: Any extrusion, infection, pain, and epistaxis were observed. All implants were placed in a sagittal, straight, and solid position without extralobular depression. Comparisons between pre- and postoperative symptoms showed that nasal comfort (p < 10-4) and quality of life (p < 10-4) were dramatically improved in all patients. The nasolabial angle (p = 0.047) and the columellar projection (p = 0.024) were improved after surgery. Histological data showed little submucosal inflammation at 6 months with well-differentiated epithelium. The mean follow-up was 23 months: three patients underwent revision surgery for functional or aesthetic details and four implants were removed (16%) owing to a foreign body reaction between 17 and 74 months. Conclusion and Relevance: The NASEPT implant meets functional and aesthetic requirements in complex septorhinoplasties but its long-term biocompatibility needs to be improved. It could potentially avoid donor site morbidity.


Assuntos
Materiais Biocompatíveis/farmacologia , Hidroxiapatitas/farmacologia , Próteses e Implantes , Rinoplastia/instrumentação , Adulto , Idoso , Estética , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Septo Nasal/cirurgia , Medição da Dor , Projetos Piloto , Complicações Pós-Operatórias , Estudos Prospectivos , Cicatrização
6.
JMIR Res Protoc ; 9(9): e17850, 2020 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-32909953

RESUMO

BACKGROUND: The International Myeloma Working Group recommends the use of 18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for treatment response evaluation, as it is superior to magnetic resonance imaging (MRI). However, at initial staging, the sensitivity of FDG-PET remains inferior to that of MRI. Therefore, there is a need for an imaging technique that could have a sensitivity equal to that of MRI at diagnosis and could serve to evaluate therapy. 18F-choline has shown increased sensitivity when compared with 18-FDG, with about 75% more lesions detected in patients with relapsed or progressive multiple myeloma (MM). OBJECTIVE: Our primary objective is to prospectively compare the detection rate of bone lesions by 18F-choline PET/CT (FCH-PET) and FDG-PET in newly diagnosed MM. Our secondary objectives are to assess the accuracy of both PET modalities for the detection of bone lesions and the diagnosis of diffuse disease, to assess the detection rate of extramedullary lesions. METHODS: We will prospectively include 30 patients in a paired comparative accuracy study. Patients with de novo MM will undergo FCH-PET, FDG-PET, and whole-body MRI (WB-MRI) within a 3-week period. WB-MRI will be composed of conventional sequences on the spine and pelvis and of whole-body diffusion axial sequences. The following 6 skeletal areas will be defined: skull, sternum/costal grid, spine, pelvis, superior limbs, and inferior limbs. The number of focal lesions, their respective localization, and intensity of uptake will be retrieved for each skeletal area. Readings will be performed blinded from other imaging techniques. The reference standard will be WB-MRI. Focal lesions present on PET/CT but not on WB-MRI will require a decision made with a consensus of experts based on clinical and imaging data. The number of bone lesions and number of extramedullary lesions will be compared using the Wilcoxon test. The accuracy of FCH-PET and FDG-PET will be compared using the McNemar test. RESULTS: The study started in September 2019, and enrollment is ongoing. As of June 2020, 8 participants have been included. Data collection is expected to be completed in June 2021, and the results are expected to be available in December 2021. CONCLUSIONS: This study will assess if FCH-PET is superior to FDG-PET for the evaluation of MM tumor burden. This will pave the way for future prospective evaluations of the prognostic value of 18-FCH for treatment response evaluation in MM patients. Additionally, this work may provide new perspectives for better assessment of the risk of smoldering MM progressing to MM. TRIAL REGISTRATION: ClinicalTrials.gov NCT03891914; https://clinicaltrials.gov/ct2/show/NCT03891914. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/17850.

7.
Ann Hematol ; 99(12): 2869-2880, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32951093

RESUMO

Magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose positron emission tomography-computed tomography (18FDG 18F-FDG PET-CT) are standard procedures for staging multiple myeloma (MM). Diffusion-weighted sequences applied to whole-body MRI (WB-DWI) improve its sensitivity. We compared the number of MM bone focal lesions (FLs) detected by 18F-FDG PET-CT and WB-DWI and evaluated the diagnostic performance of 18F-FDG PET-CT for diffuse infiltration. Thirty newly diagnosed MM patients prospectively underwent 18F-FDG PET-CT and WB-DWI. The criteria for skeletal region positivity were ≥ 1 focal bone lesions (FLs) and/or diffuse disease. MRI with the MY-RADS criteria was used as a reference standard for the diagnosis of diffuse infiltration. 18F-FDG PET-CT and WB-DWI were both interpreted as positive in 28/30 patients with an agreement of 1.00 (95% CI 0.77-1.00) between the two methods. The mean numbers of FLs were 16.7 detected by 18F-FDG PET-CT and 23.9 detected by WB-DWI (P = 0.028). WB-DWI detected more FLs in the skull (P = 0.001) and spine (P = 0.006). Agreement assessed using the prevalence and bias-corrected kappa index was moderate (0.40-0.60) for the spine, sternum-ribs and upper limbs and substantial (0.60-0.80) for the pelvis and lower limbs. As regards the diagnosis of diffuse bone marrow infiltration, the sensitivity, specificity and accuracy of 18F-FDG PET-CT were 0.75, 0.79 and 0.77, respectively. Although WB-DWI detected more FLs than did 18F-FDG PET-CT, there was no difference in the detection of bone disease on a per-patient basis. 18F-FDG PET-CT showed high performance, including for evaluation of diffuse infiltration.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Fluordesoxiglucose F18 , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Imagem Corporal Total/métodos , Adulto , Idoso , Imagem de Difusão por Ressonância Magnética/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Estudos Prospectivos , Imagem Corporal Total/normas
8.
J Interv Cardiol ; 2020: 8413831, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32665769

RESUMO

AIMS: To investigate the healing process and nickel release of the Hyperion occluder (Comed BV, Netherlands), as compared to the Amplatzer septal occluder (ASO) (St. Jude Medical Inc., St. Paul, MN, USA) in a chronic swine model. BACKGROUND: Some long-term complications occurring after percutaneous atrial septal defect (ASD) closure may be partially associated with an inappropriate healing of the device and increased nickel release. There is no direct comparative study of different occluders for healing and nickel release. METHODS: After percutaneous ASD creation, 12 pigs were implanted with 15 mm Hyperion (n = 6) and 15 mm ASO (n = 6) devices. After 1 month (n = 3 for each device) and 3 months (n = 3 for each device) of follow-up, device explantation was performed and healing was assessed using histopathological workup. Systemic and tissular nickel release was performed. RESULTS: Implantation was successful in 100% without complications. Device coverage was observed as early as 1 month after implantation and was almost complete after 3 months. A granulation tissue with a predominantly mononuclear inflammatory reaction was observed in contact with nitinol wires while an inflammatory reaction was seen in contact with textile fibers. We found no statistically significant difference between the 2 devices whether for histological grading scores or systemic nickel release, regardless to follow-up duration. CONCLUSIONS: In this preclinical study, we demonstrated that Amplatzer septal occluder and Hyperion occluder were not significantly different for device healing and nickel release processes.


Assuntos
Ligas/farmacologia , Comunicação Interatrial/cirurgia , Efeitos Adversos de Longa Duração/induzido quimicamente , Teste de Materiais/métodos , Complicações Pós-Operatórias/induzido quimicamente , Implantação de Prótese , Dispositivo para Oclusão Septal/efeitos adversos , Ligas/efeitos adversos , Animais , Pesquisa Comparativa da Efetividade , Efeitos Adversos de Longa Duração/prevenção & controle , Níquel/efeitos adversos , Níquel/farmacologia , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/prevenção & controle , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Suínos , Oligoelementos/efeitos adversos , Oligoelementos/farmacologia , Resultado do Tratamento
9.
Cancers (Basel) ; 12(6)2020 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-32481661

RESUMO

The field of multiple myeloma (MM) imaging has evolved. The International Myeloma Working Group recently recommended performing 18F-fluorodeoxyglucose glucose (18FDG) positron emission tomography/computed tomography (PET/CT) with the aim of staging MM patients at baseline and evaluating response to therapy. Novel oncological radiotracers such as 11C-Choline and 18F-Fluorocholine, have been studied in comparison with 18FDG, mostly in MM patients presenting with refractory disease or suspected relapse. Choline-based tracers may overcome some limitations of 18FDG, which include a lack of sensitivity in depicting skull lesions and the fact that 10% of MM patients are FDG-negative. The majority of MM lesions display a higher uptake of Choline than FDG. Also, in many situations, Choline may offer better lesion visualization, with a higher tumor to background ratio; however, various patterns of Choline and FDG uptake have been observed in MM and some limitations, notably as regards liver lesions, should be recognized. Overall, Choline may provide additional detection of up to 75% more lesions. This article aims to provide a comprehensive review of the potential role of Choline in multiple myeloma, as compared to FDG, encompassing Choline physiopathology as well as data from clinical studies.

11.
Br J Haematol ; 188(2): 268-271, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31388998

RESUMO

We analysed the outcomes of 62 patients with refractory/relapsed diffuse large B-cell lymphoma (rrDLBCL) who had pre-transplantation fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) after R-DHAC (rituximab, dexamethasone, high-dose cytarabine, carboplatin) salvage chemotherapy, and were evaluated using Deauville criteria and total lesion glycolysis (TLG). A positive pre-transplantation PET/CT with Deauville score of 5 was associated with shorter progression-free survival (PFS) (P = 0·01), while a Deauville score of 4 was not predictive of outcome. Only pre-transplant TLG was significantly associated with both PFS (P = 0·005) and overall survival (P = 0·03). TLG deserves to be further investigated in prospective studies.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Fluordesoxiglucose F18 , Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Linfoma Difuso de Grandes Células B/tratamento farmacológico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Terapia de Salvação/métodos , Carboplatina/administração & dosagem , Citarabina/administração & dosagem , Dexametasona/administração & dosagem , Feminino , Humanos , Linfoma Difuso de Grandes Células B/patologia , Masculino , Prognóstico , Intervalo Livre de Progressão , Compostos Radiofarmacêuticos , Rituximab/administração & dosagem
12.
Eur J Vasc Endovasc Surg ; 57(6): 876-884, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31130421

RESUMO

OBJECTIVES: Prosthetic vascular graft infections (PVGIs) are associated with high mortality rates. To improve treatment outcome, an early and definite diagnosis is critical, and current diagnostic criteria are often insufficient. The accuracy of 2-deoxy-2-[fluorine-18]-fluoro-d-glucose positron emission tomography integrated with computed tomography (18F-FDG PET/CT) and white blood cell (WBC) scan for the diagnosis of PVGI were compared. METHODS: A retrospective single centre study was conducted on patients undergoing WBC scan and 18F-FDG PET/CT for a suspected PVGI between April 2013 and June 2016 at the Bordeaux University Hospital, France. The diagnostic value of both imaging tests was assessed for all grafts, using receiver operating characteristic (ROC) curve analysis. Images were independently interpreted by two nuclear medicine physicians blinded to the patients' clinical and other imaging data. RESULTS: Thirty-nine patients were included, of whom 15 had PVGI. Antibiotic treatment was started before nuclear imaging for 16 patients, including nine patients with a PVGI. The 96 grafts of these patients were analysed, and 19 were infected. The diagnostic value of the WBC scan was significantly higher than 18F-FDG PET/CT (ROC AUC = 0.902, 95% CI 0.824-0.980, and 0.759, CI 95% (0.659-0.858), respectively, p = .0071). Interobserver agreement was good for 18F-FDG PET/CT and excellent for WBC scan (kappa value of 0.76, 95% CI 0.62-0.9, and 0.97, 95% CI 0.92-1, respectively). Only one patient had a false negative 18F-FDG PET/CT result under antibiotic therapy. CONCLUSION: The WBC scan has a better diagnostic value than 18F-FDG PET/CT for PVGI diagnosis.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Fluordesoxiglucose F18/administração & dosagem , Contagem de Leucócitos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/sangue , Infecções Relacionadas à Prótese/diagnóstico por imagem , Compostos Radiofarmacêuticos/administração & dosagem , Idoso , Implante de Prótese Vascular/instrumentação , Tomada de Decisão Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/terapia , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
Biomed Mater ; 14(2): 025009, 2019 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-30609413

RESUMO

AIMS: The need for small caliber vessels to treat cardiovascular diseases has grown. However, synthetic polymers perform poorly in small-diameter applications. Chitosan hydrogels can provide a novel biological scaffold for vascular engineering. The goal of this study was to explore host cell and tissue behavior at the interface with chitosan-based scaffolds in vitro and in vivo. METHODS AND RESULTS: in vitro, we assessed the ability of endothelial cells lining chitosan hydrogels to produce tissue factor (TF), thrombomodulin (TM) and nitric oxide. We showed that endothelial cells behave as a native endothelium since under stimulation, TF and TM expression increased and decreased, respectively. Endothelial cells seeded on chitosan produced nitric oxide, but no change was observed under stimulation. After in vivo subcutaneous implantation of chitosan hydrogels in rats, macrophage activation phenotypes, playing a crucial role in biomaterial/tissue, were explored by immunohistochemistry. Our results suggested a balance between pro- and anti-inflammatory signals since we observed an inflammatory response in favor of macrophage M2 phenotype. CONCLUSION: in vitro exploration of endothelial cell response at the interface with chitosan hydrogel showed a functional endothelium and in vivo exploration of tissue response revealed a biointegration of chitosan hydrogels.


Assuntos
Materiais Biocompatíveis/química , Prótese Vascular , Quitosana/química , Hidrogéis/química , Engenharia Tecidual/métodos , Animais , Células Cultivadas , Células Endoteliais/citologia , Endotélio Vascular/citologia , Sangue Fetal/citologia , Humanos , Imuno-Histoquímica , Macrófagos/citologia , Óxido Nítrico/química , Fenótipo , Ratos , Trombomodulina/química , Tromboplastina/química , Alicerces Teciduais
14.
Eur J Vasc Endovasc Surg ; 57(3): 424-432, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30301647

RESUMO

OBJECTIVES: The aim was to compare the antimicrobial efficacy of four different grafts: a standard graft (Intergard, IG), an IG graft soaked in rifampicin (IGrif), a silver impregnated graft (Intergard Silver, IGS), and a silver + triclosan impregnated graft (Intergard Synergy, IGSy). METHODS: This was a seven day in vitro study. The IG, IGrif, IGS, and IGSy grafts were each contaminated separately with the following microorganisms: Staphylococcus epidermidis, Methicillin resistant Staphylococcus aureus (MRSA), Escherichia coli, and Candida albicans from both clinical and American Type Culture Collection (ATCC) origins. The in vitro antimicrobial efficacy was evaluated by time to kill assays at T0, T24h, T48h, T72h, and T168h. Bactericidal activity was defined as >3 log10 reduction factor (logRF). Additionally, Rifampicin, triclosan and silver resistance development were screened. RESULTS: As anticipated for the non-antimicrobial IG, all microorganism strains proliferated. The IGSy and the IGS showed a seven day bactericidal efficacy (>3 logRF) for all tested microorganisms. This efficacy was confirmed at all time points for IGSy only, demonstrating faster bactericidal efficacy than IGS. The IGrif demonstrated a seven day bactericidal efficacy against the ATCC MRSA only, while showing no activity against C. albicans and ATCC E. coli. Regarding ATCC S. epidermidis, clinical MRSA and clinical E. coli, IGrif, although bactericidal at earlier time points, lost its antimicrobial efficacy at seven days leading to the emergence of rifampicin resistant mutants in four of six, two of six, and two of six assays, respectively. Mutant strains were also detected in ATCC MRSA in one of six assays. No triclosan or silver resistance has emerged at T7days. CONCLUSION: For all microorganisms tested, the Synergy graft combining silver with triclosan demonstrated a more sustainable and efficient seven day antimicrobial activity than the rifampicin soaked graft. The emergence of rifampicin resistant mutants suggests preference for a Synergy graft over a graft soaked in rifampicin, to prevent or treat an infection when a biological solution is not feasible.


Assuntos
Antibacterianos/farmacologia , Antifúngicos/farmacologia , Bactérias/efeitos dos fármacos , Prótese Vascular , Candida albicans/efeitos dos fármacos , Materiais Revestidos Biocompatíveis , Rifampina/farmacologia , Compostos de Prata/farmacologia , Triclosan/farmacologia , Bactérias/genética , Bactérias/crescimento & desenvolvimento , Candida albicans/crescimento & desenvolvimento , Farmacorresistência Bacteriana , Teste de Materiais , Testes de Sensibilidade Microbiana , Desenho de Prótese , Fatores de Tempo
15.
Eur Arch Otorhinolaryngol ; 276(2): 447-457, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30536161

RESUMO

PURPOSES: The purpose of this study was to compare the efficacy of a mineral-rich solution vs normal saline solution (0.9% NaCl) following endoscopic complete bilateral ethmoidectomy. METHODS: This was a prospective, multicenter, randomized, controlled, open-label trial in subjects suffering from steroid-resistant sinonasal polyposis. Adults performed 4 nasal irrigations of mineral or saline solutions daily for 28 days. Evaluations included subject-reported RHINO quality of life (QoL) and NOSE scores, tolerability, and satisfaction, the Lund-Kennedy endoscopic score and assessments of crusting, secretions and mucociliary clearance (rhinoscintigraphy). RESULTS: A total of 189 subjects were randomized. Clinically relevant improvements (> 20 points) in RhinoQOL and NOSE scores were measured in both groups without any significant inter-group difference. Among the subjects with impaired RhinoQOL at pre-inclusion, the change in Impact-RhinoQOL score was significantly superior in mineral-rich vs saline solution at day 21 (p = 0.028) and day 28 (p = 0.027). The Lund-Kennedy score continuously improved in both groups earlier with the mineral-rich solution. Crusts were significantly fewer in number and less severe/obstructive in patients receiving mineral-rich vs saline solution at day 7 (p = 0.026) and day 14 (p = 0.016). Furthermore, secretions disappeared significantly more quickly and were less thick/purulent with mineral-rich solution at day 14 (p = 0.002) and day 21 (p = 0.043). Less epistaxis was reported in the mineral vs saline solution (p = 0.008 at day 21). CONCLUSIONS: Our findings indicate that the composition of a nasal irrigation solution influences endoscopic scores and QoL after sinus surgery for patients over 60, those with an initially poor QoL and higher symptom score, and smokers.


Assuntos
Cloretos/administração & dosagem , Cuidados Pós-Operatórios , Solução Salina/administração & dosagem , Bicarbonato de Sódio/administração & dosagem , Irrigação Terapêutica/métodos , Administração Intranasal , Endoscopia , Seio Etmoidal/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pólipos Nasais/prevenção & controle , Pólipos Nasais/cirurgia , Satisfação do Paciente , Estudos Prospectivos , Qualidade de Vida , Rinite/prevenção & controle , Sinusite/prevenção & controle
16.
J Nucl Med ; 58(9): 1414-1420, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28280225

RESUMO

The aim of this study was to evaluate the relevance of PET/CT and 18F-FDG as a strategy for response evaluation after chemoradiotherapy for anal cancer. For this, the performance of posttreatment 18F-FDG PET/CT, the impact on patient care, and the predictive value of metabolic response were assessed. Methods: This was a retrospective and multicenter analysis of 87 patients treated by chemoradiotherapy for anal squamous cell carcinoma between October 2007 and October 2013. All patients underwent systematic posttreatment 18F-FDG PET/CT and were followed with at least a clinical examination every 4 mo for 2 y and every 6 mo thereafter. Disease progression was confirmed by biopsy for all patients in the case of local recurrence before surgery. Kaplan-Meier and Cox regression models were used to test for associations between metabolic or clinical endpoints and progression-free survival (PFS) or cause-specific survival (CSS). Results: The median follow-up was 25 mo. 18F-FDG PET/CT was performed 1-8 mo (median, 4 mo) after completion of chemoradiotherapy. Overall, 25 patients relapsed and 13 died. The posttherapy 18F-FDG PET/CT did not show any abnormal 18F-FDG uptake (complete metabolic response [CMR]) in 55 patients whereas 32 displayed incomplete response (non-CMR): 15 patients with partial response and 17 with disease progression. The sensitivity of 18F-FDG PET/CT to detect residual tumor tissue was 92% (95% confidence interval [CI], 75%-97%), specificity was 85% (95% CI, 75%-92%), positive predictive value was 72% (95% CI, 61%-90%), and negative predictive value was 96.4% (95% CI, 90%-98.7%). The 2-y PFS was 96% (95% CI, 90-100) for patients with CMR and 28% (95% CI, 14-47) for non-CMR patients (P < 0.0001). The 2-y CSS was 100% for patients with CMR and 59% (95% CI, 42-84) for those without CMR (P < 0.0001). 18F-FDG PET/CT changed patient management in 14 cases (16%), with relevant modifications in 12 (14%). A Cox proportional hazards model of survival outcome indicated that a CMR was the only significant predictor of PFS and CSS (P < 0.0001). Conclusion:18F-FDG PET/CT shows good accuracy in posttreatment evaluation of anal cancer and has a relevant impact on patient management. Moreover, CMR is associated with good survival outcome. Thus, 18F-FDG PET/CT may play a significant role during posttreatment follow-up of anal cancer.


Assuntos
Neoplasias do Ânus/diagnóstico por imagem , Neoplasias do Ânus/terapia , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Ânus/metabolismo , Neoplasias do Ânus/patologia , Quimiorradioterapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Análise de Sobrevida
17.
Med Sci (Paris) ; 33(1): 46-51, 2017 Jan.
Artigo em Francês | MEDLINE | ID: mdl-28120755

RESUMO

The prostheses have been around for thousands of years. Initially, it was substitute materials to replace members (leg, foot, hand) or for surgery (suture). The materials used have evolved, but they had never been created for medical applications. Recently, other strategies have emerged to construct or repair tissues. They are based on the use of biological components such as proteins or cells and provide a biological dimension to the term "biomaterial" and they often involve engineering. We illustrate the tissue engineering approaches using the examples of muscle and vessel regeneration strategies in the frame of restorative medicine.


Assuntos
Comunicação Interdisciplinar , Engenharia Tecidual/métodos , Materiais Biocompatíveis/síntese química , Materiais Biocompatíveis/química , Materiais Biocompatíveis/uso terapêutico , Vasos Sanguíneos/fisiologia , Humanos , Músculos/fisiologia , Regeneração/fisiologia
18.
Br J Haematol ; 175(4): 652-660, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27539369

RESUMO

We examined the outcome of a cohort of patients with Hodgkin lymphoma (HL) in order to assess if fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET/CT) at the end of treatment (end-PET) can be omitted when the interim PET (int-PET) is negative. Seventy-six ABVD(adriamycin, bleomycin, vinblastine, dacarbazine)-treated patients were retrospectively included. No change in treatment was made on the basis of int-PET results. Suspicious foci on end-PET received biopsy confirmation whenever possible. Median follow-up was 58·9 months. Uptake on int-PET higher than liver (scores 4-5) was rated positive according to the Lugano classification, while a positive end-PET corresponded to scores 3, 4 and 5. Fifteen patients had treatment failure. Sensitivity, specificity, positive predictive value (PPV), negative predictive value and accuracy of int-PET were 46·7%, 85·2%, 43·8%, 86·7% and 77·6%, respectively. For end-PET the figures were: 80%, 93·4%, 75%, 95% and 90·8%. Eight patients with negative int-PET had treatment failure; six of them were identified as non-responders with end-PET. The 5-year progression-free survival (PFS) was 87% for patients with negative int-PET versus 56% with positive int-PET. The 5-year PFS was 96% with negative end-PET versus 23% with positive end-PET. The prognostic information from int-PET as regards PFS (log-rank test P = 0·0048) was lower than that provided by end-PET (P < 0·0001). Int-PET predicted only half of the failures. When used in clinical routine, a negative int-PET study cannot obviate the need for end-PET examination.


Assuntos
Doença de Hodgkin/diagnóstico , Tomografia por Emissão de Pósitrons , Adolescente , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Bleomicina/uso terapêutico , Terapia Combinada , Dacarbazina/uso terapêutico , Gerenciamento Clínico , Doxorrubicina/uso terapêutico , Feminino , Fluordesoxiglucose F18 , Seguimentos , Doença de Hodgkin/mortalidade , Doença de Hodgkin/terapia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Prognóstico , Reprodutibilidade dos Testes , Falha de Tratamento , Resultado do Tratamento , Vimblastina/uso terapêutico , Adulto Jovem
19.
EJNMMI Phys ; 3(1): 16, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27495913

RESUMO

BACKGROUND: The recent spread of positron emission tomography-computed tomography (PET/CT) poses extremity dosimetry challenges. The question arose whether the radiation dose measured by the ring thermoluminescent dosimeter usually worn on the proximal phalanx (P1) of the index finger measures doses that are representative of the true doses received by the upper extremities of the operators. A prospective individual dosimetry study was performed in which the personal equivalent dose Hp (0.07) received during a specific 2-[(18)F]fluoro-2-deoxy-D-glucose ((18)F-FDG) manual dose-dispensing procedure was measured in a paired design by two operational personal electronic dosimeters fitted on the palm side of the index finger, namely in the P1 and distal phalanx (P3) positions. The study participants were ten nuclear medicine technologists working in two nuclear medicine departments. The personal equivalent radiation doses received by the palm side of the proximal phalanx of the index finger [Hp (0.07)P1] and that received by the distal phalanx [Hp (0.07)P3] were compared. RESULTS: The median Hp (0.07)P3/Hp (0.07)P1 ratio per participant varied between 1.0 and 2.5 (based on 23 to 31 measurements per participant). The 271 paired measurements revealed a crude Hp (0.07)P3/Hp (0.07)P1 ratio of 1.67, significantly different from 1 (p = 0.0004, 95 % CI [1.35-2.07]). When adjusted on participant's gender and mother vial activity, the ratio was similar (1.53, p = 0.003, 95 % CI [1.22-1.92]). CONCLUSIONS: The study demonstrated a significant disparity that may exist between the radiation doses measured in the P1 and P3 positions of operators during (18)F-FDG manipulation. These findings emphasize the importance of performing workplace dosimetry studies adapted to each radiopharmaceutical and manipulation thereof, aiming to guarantee optimal workers' dosimetry monitoring schemes. TRIAL REGISTRATION: Hospital Nursing and Paramedical Research Program (PHRIP, 2011-2013) from the French Ministry of Health (DGOS), http://social-sante.gouv.fr/IMG/pdf/Resultats_PHRIP_2011.pdf.

20.
J Nucl Cardiol ; 23(6): 1504-1507, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27151302

RESUMO

BACKGROUND: 18-Fluorodeoxyglucose positron emission tomography/computerized tomography (FDG PET/CT) scanning has recently been proposed as a diagnostic tool for lead endocarditis (LE). OBJECTIVE: FDG PET/CT might be also useful to localize associated septic emboli in patients with LE. CASE PRESENTATION: We report an interesting case of a LE patient with a prosthetic aortic valve in whom a trans-esophageal echocardiogram did not show associated aortic endocarditis. FDG PET/CT revealed prosthetic aortic valve infection. A second TEE performed 2 weeks after identified aortic vegetation. A longer duration of antimicrobial therapy with serial follow-up echocardiography was initiated. There was also increased uptake in the sigmoid colon, corresponding to focal polyps resected during a colonoscopy. CONCLUSION: FDG PET/CT scanning seems to be highly sensitive for prosthetic aortic valve endocarditis diagnosis. This promising diagnostic tool may be beneficial in LE patients, by identifying septic emboli and potential sites of pathogen entry.


Assuntos
Valva Aórtica/diagnóstico por imagem , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Diagnóstico Diferencial , Diagnóstico Precoce , Eletrodos Implantados/efeitos adversos , Humanos , Masculino , Infecções Relacionadas à Prótese/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA