Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Electrocardiol ; 85: 37-38, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38830293

RESUMO

We present the case of a 60-year-old male patient who was admitted to our hospital after experiencing a syncopal episode. First ECGs showed sinus rhythm with polymorphic premature ventricular complexes and later ventricular tachycardia with a left bundle branch block morphology were recorded. Imaging with TEE and MRI revealed a space-occupying lesion in the left ventricle, which was ultimately identified as a rare cardiac metastasis of renal cell carcinoma. Treatment was initiated with monoclonal antibodies resulting in lesion regression. This case highlights the importance of comprehensive diagnostic in patients with history of malignancy.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38750671

RESUMO

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.

3.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340118

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Sistema de Registros , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Europa (Continente) , Resultado do Tratamento , Recidiva , Reoperação/estatística & dados numéricos
4.
Circ Arrhythm Electrophysiol ; 16(7): 389-398, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37254781

RESUMO

BACKGROUND: The cryoballoon (CB) represents the gold standard single-shot device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Single-shot pulsed field PVI ablation (nonthermal, cardiac tissue selective) has recently entered the arena. We sought to compare procedural data and long-term outcome of both techniques. METHODS: Consecutive AF patients who underwent pulsed field ablation (PFA) and CB-based PVI were enrolled. CB PVI was performed using the second-generation 28-mm CB; PFA was performed using a 31/35-mm pentaspline catheter. Success was defined as freedom from atrial tachyarrhythmia after a 3-month blanking period. RESULTS: Four hundred patients were included (56.5% men; 60.8% paroxysmal AF; age 70 [interquartile range, 59-77] years), 200 in each group (CB and PFA), and baseline characteristics did not differ. Acute PVI was achieved in 100% of PFA and in 98% (196/200) of CB patients (P=0.123; 4 touch-up ablations). Median procedure time was significantly shorter in PFA (34.5 [29-40] minutes) versus CB (50 [45-60] minutes; P<0.001), fluoroscopy time was similar. Overall procedural complications were 6.5% in CB and 3.0% in PFA (P=0.1), driven by a higher rate of phrenic nerve palsies using CB. The 1-year success rates in paroxysmal AF (CB, 83.1%; PFA, 80.3%; P=0.724) and persistent AF (CB, 71%; PFA, 66.8%; P=0.629) were similar for both techniques. CONCLUSIONS: PFA compared with CB PVI shows a similar procedural efficacy but is associated with shorter procedure time and no phrenic nerve palsies. Importantly, 12-month clinical success rates are favorable but not different between both groups.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Masculino , Humanos , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Paralisia/cirurgia , Ablação por Cateter/métodos , Recidiva
5.
Europace ; 24(10): 1684-1690, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35942585

RESUMO

The use of a blanking period (BP) after an atrial fibrillation (AF) ablation procedure is a common practice, but recent data questions the benign nature of early recurrences of atrial tachyarrhythmias (ERATs). A physician-based survey was carried out by the European Heart Rhythm Association (EHRA) to investigate the current definition and applicability of BP and ERAT management. An online questionnaire was sent to clinical and interventional electrophysiologists. A total of 436 respondents (88% interventional electrophysiologists) reported observing ERATs in 25% (interquartile range 15-35) of patients, less commonly in paroxysmal AF (PAF) compared with persistent AF (persAF). The median reported duration of BP used by respondents was 90 days, with 22% preferring a shorter BP duration for PAF patients compared with persAF. Half of the patients with ERATs are expected to also experience late recurrences (LR). Isolated episodes of ERATs are treated conservatively by 99% of the respondents, but repeat ablation during the BP is preferred by 20% of electrophysiologists for multiple ERATs and by 16% in patients with organized atrial tachyarrhythmias. In conclusion, ERATs are commonly observed after AF ablation, particularly in persAF patients, and are perceived as predictors of LR by half of the respondents. A general adherence to a 90-day BP duration was observed. During this time period, ERAT is mainly treated conservatively, but repeat ablation during the BP is occasionally offered to patients with multiple ERATs and those with organized atrial tachyarrhythmias.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Inquéritos e Questionários , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 33(7): 1371-1379, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35488736

RESUMO

BACKGROUND: The iCLAS ultra-low temperature cryoablation (ULTC) system has recently been brought to the market. A combination of a newly exploited cryogen and interchangeable stylet enables flexible and continuous lesion creation in atrial fibrillation (AF) ablation. The use of an esophageal warming balloon is recommended when using the system to reduce the potential for collateral esophageal injury. OBJECTIVE: To describe the initial clinical experience when using ULTC in the AF treatment without general anesthesia (GA). METHODS: Consecutive patients undergoing AF ablation using ULTC under deep sedation without GA were enrolled. We assessed the procedural data focusing on "single-shot isolation" defined as successful pulmonary vein (PV) isolation after the first application. Esophagogastroduodenoscopy was systematically performed the day after ablation. RESULTS: A total of 27 AF patients (67% paroxysmal AF) were analyzed. Onehundred four out of 106 PVs (98.1%) were isolated solely using ULTC. The mean procedure time was 79 ± 30 min. The mean number of applications per PV was 2.6 ± 1.0. Single-shot isolation was achieved in 57 PVs (54%) varying across PVs from left superior to inferior PVs (40%-64%). The single procedure 6-month recurrence-free rate was 84%. No major complication (cerebrovascular event, pericardial effusion/tamponade, esophageal damage on esophagogastroduodenoscopy) occurred. A single transient phrenic nerve palsy occurred during the right superior PV ablation, which had recovered by the 3-month follow-up appointment. CONCLUSIONS: AF ablation using the novel ULTC system seemed feasible without GA and enabled a >50% single-shot isolation rate. The promising safety profile has to be confirmed in large-scale studies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 33(6): 1106-1115, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35355367

RESUMO

INTRODUCTION: Ablation of atrial fibrillation in the context of obesity can be challenging. We sought to evaluate the role of cryoballoon pulmonary vein isolation (CB-PVI) in obese patients with symptomatic atrial fibrillation (AF). METHODS: Patients with a BMI ≥ 25 kg/m2 and symptomatic AF who underwent CB-PVI were retrospectively enrolled. Three groups were defined (G1: BMI of 25-29 kg/m2 ; G2: BMI of 30-34 kg/m2 ; G3: BMI ≥ 35 kg/m2 ). RESULTS: 600 patients were included (59% male; 66 ± 11 years old); 337, 149, and 114 were assigned to G1, G2, and G3, respectively. Acute procedural success was recorded in 99.7% of patients. Procedural and fluoroscopy time were comparable but the radiation dose was significantly higher in G3. Procedural complications were 3% in G1, 5.4% in G2, and 8.8% in G3 (p = .01). The overall freedom from AF after 1-year was 77%. G3 had a significantly worse 1-year success rate compared to G1 and G2 (G3: 66.5% vs. G1: 78.4%; p = .015 and vs. G2: 82.5%; p = .008) with reduced 1-year success in paroxysmal AF (G1: 84.0%; G2: 86.3%; and G3: 69.6%) but not in persistent AF (G1: 68.7%; G2: 77.4%; and G3: 62.1%). G3 showed similar success rates irrespective of AF form (PAF: 69.6% vs. persAF 62.1%; p = .501). CONCLUSION: Cryoballoon ablation in obese patients can be effective with an acceptable safety profile, 77% of patients were in stable SR at 1 year. Severe obese patients (BMI ≥ 35) showed reduced procedural safety and 1-year success rate. In association with life style modification, CB ablation may represent a strategy to enhance rhythm control in the context of obesity.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Índice de Massa Corporal , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/diagnóstico , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
8.
Herzschrittmacherther Elektrophysiol ; 32(4): 550-562, 2021 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-34735629

RESUMO

In the current guidelines on treatment of atrial fibrillation, cryoballoon-based catheter ablation of atrial fibrillation is recommended in addition to radiofrequency ablation and has become established as a standard procedure in the clinical routine of many centers for index pulmonary vein isolation. A safe, simplified and often durable pulmonary vein isolation can be achieved by a systematic approach. This review article provides a practical guide for all steps of cryoballoon-based pulmonary vein isolation, including preprocedural preparation and postinterventional follow-up. Both cryoballoon systems currently available on the market are considered.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
J Cardiol ; 78(5): 388-396, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34332839

RESUMO

BACKGROUND: The second- and third-generation endoscopic ablation systems (EAS2 and EAS3) have been launched in recent years. We aimed to assess the lesion durability as well as gap localization using the multigenerational novel technologies in patients with recurrent atrial fibrillation (AF). METHODS: Consecutive patients who underwent second ablation for recurrent AF following the initial pulmonary vein isolation (PVI) with EAS2 or EAS3 were retrospectively investigated. The persistent durability of PVI, gap localization at the second procedure, and procedural/anatomical features of durable PVI were analyzed. RESULTS: Among 225 patients treated with EAS3 (N = 125) and EAS2 (N = 100), 34 patients (EAS3: 13 patients, 50 PVs, EAS2: 21 patients, 82 PVs) underwent a second procedure because of recurrent AF mean 11.9 ± 9.3 months after the initial procedure. Persistent isolation of all four PVs was recorded in 6 (46.2%) patients in EAS3 group and 4 (19.1%) patients in EAS2 group (p = 0.130). Ninety-one out of 132 (68.9%) PVs were persistently isolated with a higher rate in EAS3 group (82.0% vs. EAS2 group: 61.0%, p = 0.0113). A total of 45 gaps were recorded in 41 PVs. Right superior PV (RSPV) was the predominantly common reconnected vein (15 gaps, 14 PVs) irrespective of generations (EAS3: 4 gaps in 3 PVs and EAS2: 12 gaps in 11 PVs). Logistic multivariate regression analysis revealed ablation without reduced energy dose (5.5-7 W) as an independent predictor of durable PVI [adjusted OR: 3.70, 95% CI (1.408-10.003)], p = 0.008]. CONCLUSION: The technical innovation resulted in a higher lesion durability in EAS3-guided PVI in patients with recurrent AF. The most common gap location was found at RSPV in successor EASs. Ablation without reduced energy was a predictor of durable PVI in successor EASs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Lasers , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
10.
Pacing Clin Electrophysiol ; 44(8): 1371-1379, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34152640

RESUMO

BACKGROUND: Recently a double 120 s freeze cryoballoon (CB) pulmonary vein isolation (PVI) protocol proved to be non inferior to a double 240 s freeze protocol in terms of atrial fibrillation (AF) recurrences. We hypothesized that this approach could also result in an increased procedure safety. METHODS: Eighty consecutive patients treated with a double 120 s freeze protocol (Group CB120) were compared with 80 previous consecutive patients treated with a single 240 s freeze protocol (Group CB240). Procedures were performed with a temperature probe to monitor the luminal esophageal temperature (LET), using a cut off for cryoenergy interruption of 15°C. During ablation at the septal pulmonary veins (PVs), the phrenic nerve (PN) function was monitored by pacing. RESULTS: In CB120 and CB240 the rate of single shot isolation was similar in all PVs. Time to isolation was not different between the two groups. Mean minimal esophageal temperature was lower in LSPV and LIPV of the CB240 group. A total of 4/80 patients (5%) of the CB120 group experienced a PN injury, but no persistent form was recorded; 11/80 patients (14%) of the CB240 group experienced a PN injury, three in a persistent form (p = .10). A LET <15°C was recorded in 3/80 patients (4%) in the CB120 group and in 16/80 patients (20%) in the CB240 group (p < .01). Composite rate of energy-related safety events (LET <15°C and PN injury) was significantly lower in the CB120 (34% vs. 9%, p < .01). CONCLUSIONS: Safety of second generation CB PVI can be increased using a double 120 s freeze protocol.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/instrumentação , Segurança do Paciente , Veias Pulmonares/cirurgia , Idoso , Feminino , Humanos , Masculino
11.
Glob Cardiol Sci Pract ; 2021(1): e202103, 2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-34036089

RESUMO

Objective: Epicardial access is sometimes required to effectively treat ventricular arrhythmias, but it can be associated with increased risk of procedural complications needing surgical intervention. The present study aimed to evaluate the feasibility and safety of epicardial mapping/ablation in experienced center without onsite cardiac surgery. Methods: Patients who had drug-refractory, recurrent ventricular arrhythmias were scheduled for catheter ablation. All operators (SC, JC, SB, BS) had at least fifty pericardial puncture experiences. Epicardial puncture and perioperative anticoagulation were carried out based on institutional protocol. Phrenic nerve was mapped by 3-D mapping system. Coronary anatomy was delineated by coronary angiography. Results: A total of 44 patients (63.3 years, male 86.4%) received epicardial access. Of them 7 (15.9%) were scheduled for PVC ablation, 37 (84.1%) for VT ablation (ICM: 25%, NICM: 59.1%). Mean LVEF was 41.3%. Acute ablation success rate was 35 (79.5%). Procedural adverse events included: pericardial effusion occurred in 3 (6.8%) patients who all well treated with pericardial drainage; and pericardial tamponade in 1 (2.3%) patient requiring transfer to surgical intervention. No death, stroke, phrenic nerves palsy, or coronary artery injury were observed. Median hospitalization was 4 (3-6) days. Univariable analysis and ROC curve showed that patients' age was a significant predictor of epicardial procedural complication (area under curve (AUC): 0.813, P = 0.041). Conclusions: Guided by a tailored procedural protocol, the majority of the epicardial access related complications can be treated conservatively without needing onsite surgery. Older age is a risk factor associated with epicardial access related complications.

13.
Europace ; 23(6): 868-877, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33458770

RESUMO

AIMS: Cryoballoon (CB) pulmonary vein isolation (PVI) is an accepted ablation strategy for rhythm control in atrial fibrillation (AF). We describe efficacy and safety in a high volume centre with a long experience in the use of the second-generation CB (CB2). METHODS AND RESULTS: Consecutive paroxysmal AF (PAF) or persistent AF (persAF) patients undergoing CB2-PVI were enrolled. Procedural data, efficacy, and safety issues were systematically collected. The 28 mm CB2 was used in combination with an inner lumen spiral catheter, a luminal oesophageal temperature (LET) probe was used with a cut-off of 15°C, the phrenic nerve (PN) monitored during septal PVs ablation. Freeze duration was mainly set at 240 s with a bonus application in case of delayed time-to-isolation (TTI > 75 s). A total of 1017 CB2 procedures were analysed (58% male, 66 ± 12 years old, 70% with PAF). 3964 PVs were identified, 99.8% PVs isolated using solely the 28 mm CB. Mean procedure time was 69 ± 25 min, TTI during the first application was recorded in 77% of PVs after a mean of 48 ± 31 s. We recorded 0.2% cardiac tamponade, 4.8% PN injury (1.6% of PN palsy), and 19% of LET < 15°C. Among 725 patients with follow-up data, 84% with PAF and 75% with persAF were in stable SR at 1 year. Shorter freezing duration and longer TTI were procedural predictors for recurrence. CONCLUSION: Cryoballoon procedures are fast and associated with a benign safety profile. Shorter TTI and longer freeze durations are associated with sinus rhythm during follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
14.
Circ Arrhythm Electrophysiol ; 14(2): e009294, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33417476

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) represents the cornerstone in atrial fibrillation ablation. Cryoballoon and laserballoon catheters have emerged as promising devices but lack randomized comparisons. Therefore, we sought to compare efficacy and safety comparing both balloons in patients with persistent and paroxysmal atrial fibrillation (AF). METHODS: Symptomatic AF patients (n=200) were prospectively randomized (1:1) to receive either cryoballoon or laserballoon PVI (cryoballoon: n=100: 50 paroxysmal atrial fibrillation + 50 persistent AF versus laserballoon: n=100: 50 paroxysmal atrial fibrillation + 50 persistent AF). All antiarrhythmic drugs were stopped after ablation. Follow-up included 3-day Holter-ECG recordings and office visits at 3, 6, and 12 months. Primary efficacy end point was defined as freedom from atrial tachyarrhythmia between 90 and 365 days after a single ablation. Secondary end points included procedural parameters and periprocedural complications. RESULTS: Patient baseline parameters were not different between both groups. In all (n=200) complete PVI was obtained and the entire follow-up accomplished. Balloon only PVI was obtained in 98% (cryoballoon) versus 95% (laserballoon) requiring focal touch-up in 2 and 5 patients, respectively. Procedure but not fluoroscopy time was significantly shorter in the cryoballoon group (50.9±21.0 versus 96.0±20.4 minutes; P<0.0001 and 7.4±4.4 versus 8.4±3.2 minutes, P=0.083). Overall, the primary end point of no atrial tachyarrhythmia recurrence was met in 79% (cryoballoon: 80.0% versus laserballoon: 78.0%, P=ns). No death, atrio-esophageal fistula, tamponade, or vascular laceration requiring surgery occurred. In the cryoballoon group, 8 transient but no persistent phrenic nerve palsy were noted compared with 2 persistent phrenic nerve palsy and one transient ischemic attack in the laserballoon group. CONCLUSIONS: Both balloon technologies represent highly effective and safe tools for PVI resulting in similar favorable rhythm outcome after 12 months. Use of the cryoballoon is associated with significantly shorter procedure but not fluoroscopy time.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Terapia a Laser/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Recidiva , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 31(8): 1923-1931, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32495488

RESUMO

BACKGROUND: Time-to-isolation (TTI) guided second-generation cryoballoon (CB2) ablation has been shown to be effective for pulmonary vein isolation (PVI). OBJECTIVE: The objective of this paper is to compare the safety and clinical outcome of CB2 PVI using the TTI guided 4 minutes vs 3 minutes freeze protocol. METHODS: This was a propensity-matched study based on an institutional database. Symptomatic atrial fibrillation (AF) patients who underwent CB2 PVI and systematic follow-up were consecutively included. RESULTS: A total of 573 patients were identified, of them 214 (107 matched-pairs) symptomatic AF (paroxysmal AF: 61%, persistent AF: 39%) patients (age: 67.7 ± 11.2 years) were analyzed. The baseline characteristics were comparable between the two groups. Procedural time was significantly longer in the 4 minutes group compared to 3 minutes group (67.2 ± 21.8 vs 55.9 ± 16.9 minutes, P < .0001). During a mean follow-up of 2 years, the 4 minutes group was associated with a significantly higher rate of freedom from arrhythmia recurrence compared with the 3 minutes group (66.4% vs 56.1%, P = .009), which was mainly driven by patients with persistent AF. The multivariate regression showed that the 4 minutes freeze was the independent predictor of freedom from arrhythmia recurrence. During the repeat procedure, the 4 minutes group was associated with a significantly higher rate of durable PVI. There was no difference regarding procedural adverse events between the two groups. CONCLUSION: As compared with the 3 minutes freeze, the TTI guided 4 minutes freeze is associated with a significantly higher rate of arrhythmia-free and durable PVI without compromising the safety profile, patients with persistent AF may benefit from the TTI guided 4 minutes freeze more pronouncedly.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 31(8): 1932-1941, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32419183

RESUMO

AIMS: Systematic data on phrenic nerve palsy (PNP) associated with contemporary balloon ablation techniques (cryoballoon [CBA] vs laser balloon [LBA]) are sparse. We aimed to investigate the incidence, characteristics, and clinical recovery course in patients with PNP who underwent CBA or LBA. METHODS AND RESULTS: A total of 2433 consecutive patients who underwent balloon-based pulmonary vein isolation (CBA: n = 1720 and LBA: n = 713) were retrospectively identified. PNP was classified into (a) transient (recovery before discharge) or (b) persistent (within 6 months, 6-12 months, and >12 months) according to clinical recovery course. In general, PNP occurred significantly more often in CBA 71/1720 (4.2%) than LBA 11/713 (1.5%) (P = .003). The rate of transient PNP was significantly higher in CBA (3.0%, n = 45) than LBA (0.1%, n = 1, P = .004). The rate of persistent PNP did not significantly differ between two groups (CBA: 1.2% vs LBA: 1.4%, P = .89). The rate of persistent PNP which recovered within 6 months was similar (CBA: 17.4% vs LBA 18.2%, P = 1.000). However, the rates of persistent PNP which recovered within 6 to 12 months (CBA: 2.9% vs LBA 27.3%, P = .0171) and more than 12 months (CBA: 7.3% vs LBA 45.5%, P = .0034) were significantly higher in LBA. CONCLUSION: PNP occurred more often in CBA than LBA, however, the majority of PNP in CBA was transient whereas the majority of PNP in LBA was persistent. Either balloon technology is not superior in terms of long-term PNP.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Traumatismos dos Nervos Periféricos , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Humanos , Incidência , Traumatismos dos Nervos Periféricos/diagnóstico , Traumatismos dos Nervos Periféricos/epidemiologia , Traumatismos dos Nervos Periféricos/etiologia , Nervo Frênico , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
17.
Heart Rhythm ; 17(11): 1833-1840, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32470628

RESUMO

BACKGROUND: High-power, short-duration ablation for pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF) facilitates the procedure and improve effectiveness; however, esophageal injury remains a safety concern. OBJECTIVE: The purpose of this study was to investigate the role of luminal esophageal temperature (LET) monitoring during high-power ablation for PVI in terms of endoscopic esophageal lesion. METHODS: Patients with symptomatic AF underwent ablation index-guided high-power (AI-HP) PVI (50 W; AI anterior wall/posterior wall: 550/400). In the first consecutive set of patients, an insulated esophageal temperature probe was used for LET monitoring (cutoff LET >39°C) (group A). In the second consecutive set of patients, the probe was not used (group B). All patients were scheduled to undergo esophageal endoscopy 1-3 days after ablation. RESULTS: A total of 120 patients (60 group A; 60 group B) were included in the study (mean age 67.8 years; 64% male). Baseline characteristics and procedural outcomes were similar between the 2 groups. Procedural PVI was achieved in all patients. First-pass PVI rate was 96.6%. Mean procedural radiofrequency (RF) time was 11.5 minutes, mean procedural time was 55.5 minutes, and fluoroscopic time was 5.6 minutes. Mean contact force at the LA posterior wall was 23 g, and mean RF ablation time at the LA posterior wall was 3.2 minutes. Two patients in group A and 1 patient in group B had endoscopic small esophageal lesions (P = .99). No serious procedural adverse events were observed. CONCLUSION: Among patients undergoing AI-HP (50 W) PVI, the incidences of ablation-related endoscopic esophageal lesion in patients with and those without use of a temperature probe for LET monitoring (cutoff 39°C) were comparably low.


Assuntos
Fibrilação Atrial/cirurgia , Temperatura Corporal/fisiologia , Ablação por Cateter/métodos , Esôfago/fisiopatologia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Esofagoscopia , Feminino , Humanos , Masculino , Recidiva , Fatores de Tempo , Resultado do Tratamento
18.
JACC Case Rep ; 2(15): 2331-2335, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34317166

RESUMO

We present a case of ventricular fibrillation triggered by a premature ventricular complex. During ablation from the left coronary cusp, the ablation catheter dislodged inside left main coronary artery, thus resulting in cardiac arrest. We immediately performed angioplasty and stent implantation, and the procedure was accomplished with a guiding catheter left inside the vessel. (Level of Difficulty: Intermediate.).

19.
J Interv Card Electrophysiol ; 57(3): 465-471, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31065849

RESUMO

PURPOSE: Durable pulmonary vein isolation (PVI) is the goal of atrial fibrillation (AF) ablation. The endoscopic ablation system (EAS) is associated with a high rate of persistent PVI. The aim of this study was to analyze the incidence and pattern of conduction gaps in patients with arrhythmia recurrence after an EAS-guided PVI. METHODS: Repeat ablations after an EAS-guided PVI were analyzed. After PV angiograms, PV reconnection was assessed. Radiofrequency ablation was delivered at the earliest pulmonary vein (PV) activation site (gap) with the goal of PV re-isolation. First, the incidence of reconnected PVs per patient was assessed. Second, the gap pattern according to the individual PV quadrant was analyzed. RESULTS: Fifty-nine out of 373 (16%) patients underwent a second procedure after index EAS. PV reconnection was observed in 71/230 (31%) PVs without statistically significant differences between individual PVs. A higher incidence of gaps was found for right PVs (49 vs. 27; p 0.0006). The carina between the superior and inferior PV presented a low incidence of gaps (18 vs. 56, p < 0.0001). Gaps were also predominant at the AS segment of the RSPV (11 gaps). No predictors of reconnection were found, except the higher total amount of application in the reconnected right inferior PV (26.03 ± 1.30 vs. 32.04 ± 2.89; p 0.0396). CONCLUSION: EAS-guided PVI results in a 72% durable PVI rate in patients with AF recurrences without difference between individual PVs. More of the gap was found in the right PVs especially in the anterosuperior segment of the RSPV.


Assuntos
Fibrilação Atrial/cirurgia , Endoscopia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/métodos , Idoso , Angiografia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ecocardiografia Transesofagiana , Feminino , Humanos , Incidência , Masculino , Veias Pulmonares/diagnóstico por imagem , Punções , Reoperação , Estudos Retrospectivos
20.
JACC Clin Electrophysiol ; 5(5): 551-559, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31122376

RESUMO

OBJECTIVES: This study sought to evaluate the durability of pulmonary vein isolation (PVI) after 2 different freeze durations by using time-to-effect guided (ICE-T) second generation cryoballoon (CB2) ablation strategy in patients with atrial fibrillation (AF) undergoing repeat procedure. BACKGROUND: CB2 represents a powerful technology for PVI. Recently, the ICE-T CB2 ablation strategy targeting a 240-s single freeze demonstrated fast and efficient PVI. To further optimize safety and efficacy, a shortened 3-min freeze duration has been suggested, but PVI durability remains unclear. METHODS: Between May 1, 2013 and December 31, 2017, all CB2 ablations followed the ICE-T concept (target freeze: 240 s or 180 s). Patients undergoing a second procedure for arrhythmia recurrence were analyzed. Two groups were defined based on the index freeze duration (group A: 240 s vs. group B: 180 s). In all repeat procedures a 3-dimensional left-atrial map was obtained. Durability of PVI and localization of conduction gaps were compared. RESULTS: Of 788 total patients, 106 (13%) underwent a second procedure (group A: 80 of 604 vs. group B: 26 of 184) after a mean of 377 days. There was no difference regarding PV occlusion and time-to-isolation in the index procedure between the 2 groups. No major complications occurred. During the second procedure, significantly more patients demonstrated durable isolation of all PV in group A (61% vs. 35%; p = 0.02) along with a significantly increased rate of PVI durability (88% vs. 69%, per vein; p < 0.001). Left-sided PV did significantly benefit from 240-s freeze (reconnection left superior PV: 6% vs. 27%; p = 0.004, left inferior PV: 14% vs. 39%; p = 0.006). CONCLUSIONS: The ICE-T ablation strategy is associated with a high rate of durable PVI in patients with arrhythmia recurrence. Target freeze duration of 240 s versus 180 s is associated with significantly increased lesion durability, particularly at left-sided PV, without increasing complications.


Assuntos
Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Criocirurgia/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA