Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Mater Sci Eng C Mater Biol Appl ; 33(1): 317-26, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25428078

RESUMO

The aim of this study is to compare the biocompatibility of the two magnesium based alloys LAE442 and LANd442 with that of titanium. For this purpose, cylindrical implants were introduced into the medullary cavity of rabbit's tibiae for 4 and 8 weeks. Animals without any implant served as a control. In the follow-up, clinical, X-ray and µCT-investigations were performed to evaluate the reactions of the bone towards the implanted materials. After euthanasia, ex vivo µCT- and histological investigations were performed to verify the results of the in vivo tests. It could be shown that all materials induce changes in the bone. Whereas LANd442 caused the most pronounced reactions, such as increasing bone volume and bone porosity and decreasing bone density, titanium showed the most bone-implant contact by forming trabeculae. The tibiae of rabbits without implants also reacted by forming cavities, it is therefore assumed that the surgery method itself influences the bone.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Magnésio/química , Titânio/química , Implantes Absorvíveis , Animais , Materiais Biocompatíveis/farmacologia , Densidade Óssea/efeitos dos fármacos , Regeneração Óssea/efeitos dos fármacos , Modelos Animais de Doenças , Magnésio/farmacologia , Microscopia de Fluorescência , Porosidade , Coelhos , Tíbia/diagnóstico por imagem , Tíbia/patologia , Tomografia Computadorizada por Raios X
2.
J Biomed Mater Res A ; 100(11): 2881-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22623368

RESUMO

A small animal model was established to evaluate the potential of iron as a degradable implant material. After insertion into the tail of mice, the implants gradually degraded over a clinically relevant time period of several months. Histological analysis and gene expression data from whole-genome microarray analyses indicated a limited inflammatory reaction. No evidence of cellular responses to excess iron ions was detected, suggesting that the iron degradation products were metabolically inactive. Iron-rich compounds could be detected in the vicinity of the implant and in individual cells distant from the implantation site. These results demonstrate that the mouse model could be useful for the primary in vivo evaluation of novel implant materials and that iron degradation products can accumulate in diverse organs of the body.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis/metabolismo , Ferro/metabolismo , Animais , Materiais Biocompatíveis/química , Corrosão , Feminino , Perfilação da Expressão Gênica , Ferro/química , Teste de Materiais , Camundongos , Camundongos Endogâmicos BALB C , Cicatrização
3.
Biomed Eng Online ; 11: 14, 2012 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-22429539

RESUMO

BACKGROUND: Most studies on biodegradable magnesium implants published recently use magnesium-calcium-alloys or magnesium-aluminum-rare earth-alloys.However, since rare earths are a mixture of elements and their toxicity is unclear, a reduced content of rare earths is favorable. The present study assesses the in vivo biocompatibility of two new magnesium alloys which have a reduced content (ZEK100) or contain no rare earths at all (AX30). METHODS: 24 rabbits were randomized into 4 groups (AX30 or ZEK100, 3 or 6 months, respectively) and cylindrical pins were inserted in their tibiae. To assess the biodegradation µCT scans and histological examinations were performed. RESULTS: The µCT scans showed that until month three ZEK100 degrades faster than AX30, but this difference is leveled out after 6 months. Histology revealed that both materials induce adverse host reactions and high numbers of osteoclasts in the recipient bone. The mineral apposition rates of both materials groups were high. CONCLUSIONS: Both alloys display favorable degradation characteristics, but they induce adverse host reactions, namely an osteoclast-driven resorption of bone and a subsequent periosteal formation of new bone. Therefore, the biocompatibility of ZEK100 and AX30 is questionable and further studies, which should focus on the interactions on cellular level, are needed.


Assuntos
Ligas/metabolismo , Ligas/toxicidade , Magnésio/metabolismo , Magnésio/toxicidade , Teste de Materiais/métodos , Modelos Animais , Animais , Medula Óssea/diagnóstico por imagem , Medula Óssea/efeitos dos fármacos , Medula Óssea/metabolismo , Minerais/metabolismo , Próteses e Implantes/efeitos adversos , Coelhos , Coloração e Rotulagem , Cloreto de Tolônio/metabolismo , Microtomografia por Raio-X
4.
Acta Biomater ; 7(3): 1421-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21050898

RESUMO

The aim of this study was to compare the biomechanical properties of degradable magnesium calcium alloy (MgCa0.8) screws and commonly used stainless steel (S316L) screws and to assess the in vivo degradation behavior of MgCa0.8. MgCa0.8 screws (n=48) and S316L screws (n=32) were implanted into both tibiae of 40 adult rabbits for a follow-up of 2, 4, 6 and 8 weeks. This resulted in a testing group of MgCa0.8 (n=12) and S316L (n=8) screws for each follow-up. Uniaxial pull-out tests were carried out in an MTS 858 Mini Bionix at a rate of 0.1 mm s(-1). For degradation analysis of MgCa0.8 in vivo micro-computed tomography (µCT) was performed to determine the volume of metal alloy remaining. Retrieved MgCa0.8 screws were analysed for degradation by determination of weight changes, scanning electron microscopy and energy dispersive X-ray analyses. No significant differences could be noted between the pull-out forces of MgCa0.8 and S316L 2 weeks after surgery (P=0.121). Six weeks after surgery the pull-out force of MgCa0.8 decreased slightly. In contrast, the S316L pull-out force increased with time. Thus, significantly higher pull-out values were detected for S316L from 4 weeks on (P<0.001). The volume and weight of MgCa0.8 gradually reduced. A corrosion layer, mainly composed of oxygen, magnesium, calcium and phosphorus, formed on the implants. Since MgCa0.8 showed good biocompatibility and biomechanical properties, comparable with those of S316L in the first 2-3 weeks of implantation, its application as a biodegradable implant is conceivable.


Assuntos
Ligas , Fenômenos Biomecânicos , Cálcio/química , Magnésio/química , Animais , Coelhos , Tomografia/métodos
5.
Biomaterials ; 31(14): 3878-84, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20170953

RESUMO

The osteoinductivity of human growth-and-differentiation factor-5 (GDF-5) is well established, but a reduced amount of ectopic bone is formed compared to other members of the bone morphogenetic protein (BMP) family like BMP-2. We hypothesized that swap of two BMP-receptor-interacting residues of GDF-5 to amino acids present in BMP-2 (methionine to valine at the sites 453 and 456) may improve the bone formation capacity of the mutant GDF-5. Heterotopic bone formation of a mutant GDF-5 coated beta-TCP carrier was compared to carriers coated with similar amounts (10 microg) of GDF-5 and BMP-2 in SCID mice. Four week explants revealed 6-fold higher ALP activity in the mutant GDF-5 versus the wild type GDF-5 group (p < 0.0001) and 1.4-fold higher levels compared to BMP-2 (p < 0.006). Bone area in histology was significantly higher in mutant GDF-5 versus all other groups at 4 weeks; however, at 8 weeks BMP-2 reached a similar neo-bone formation like mutant GDF-5. Micro-CT evaluation confirmed higher values in the mutant GDF-5 and BMP-2 groups compared to wild type GDF-5. In conclusion, the mutant GDF-5 showed superior bone formation capacity than GDF-5, and a faster induction at similar final outcome as BMP-2. Mutant GDF-5 thus represents a promising new GDF-5 variant for bone regeneration possibly acting via an increased binding affinity to the BMP-type I receptor.


Assuntos
Fosfatos de Cálcio/química , Coristoma/patologia , Fator 5 de Diferenciação de Crescimento/genética , Fator 5 de Diferenciação de Crescimento/farmacologia , Osteogênese/efeitos dos fármacos , Mutação Puntual/genética , Alicerces Teciduais/química , Fosfatase Alcalina/metabolismo , Animais , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/efeitos dos fármacos , Osso e Ossos/enzimologia , Osso e Ossos/patologia , Ativação Enzimática/efeitos dos fármacos , Fator 5 de Diferenciação de Crescimento/química , Fator 5 de Diferenciação de Crescimento/metabolismo , Humanos , Camundongos , Camundongos SCID , Estrutura Secundária de Proteína , Proteínas Recombinantes/química , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Proteínas Recombinantes/farmacologia , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA