Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 186(1): 78-82, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30806468

RESUMO

The treatment with high doses of ionizing radiation is prescribed for the terminal sterilization of many healthcare products. In order to check the product irradiation, it may be useful to develop suitable detection methods. The aim of this work was to verify the suitability of the thermoluminescence (TL) and electron paramagnetic resonance (EPR) techniques to reveal illegal omission of radiation sterilization in glass used for blood test tubes. In particular, this work reports the results of the analysis performed on two batches of glass tubes provided by the same manufacturer. The results indicated that both TL and EPR techniques could reveal the damage induced by high doses of ionizing radiation in the glass allowing the identification of the tubes which were irradiated at the manufacture stage. The study provided also some information about the chemical composition of the two-batch glass.


Assuntos
Produtos Biológicos/análise , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Vidro/química , Vidro/efeitos da radiação , Radiometria/métodos , Dosimetria Termoluminescente/métodos , Relação Dose-Resposta à Radiação , Humanos , Medições Luminescentes , Radiação Ionizante
2.
Radiat Prot Dosimetry ; 164(1-2): 42-5, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25205835

RESUMO

Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos/prevenção & controle , Emergências , Europa (Continente) , Humanos , Exposição à Radiação/prevenção & controle , Gestão da Segurança/organização & administração
3.
Radiat Prot Dosimetry ; 120(1-4): 226-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644956

RESUMO

In the implementation of a large-scale dosimetry intercomparison one of the main constraints is the availability of large number of dosemeters of the highest quality. Therefore, ISS tested the possibility of using commercially available dosemeters, alanine pellets and thermoluminescence (TL) dosimetry chips, for transfer dosimetry within the Italian intercomparison programme. In this work the characterisation of commercial alanine and TL dosemeters along with the ISS dose assessment procedure used in the Italian intercomparison are reported. Results demonstrate the feasibility of the ISS approach to transfer dosimetry since it is possible to measure 10 Gy with a combined uncertainty of 1% (1sigma) and 1 Gy with a combined uncertainty of 1.7% (1sigma) with alanine and TL dosemeters, respectively.


Assuntos
Alanina/química , Alanina/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Radioterapia/instrumentação , Dosimetria Termoluminescente/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Itália , Teste de Materiais , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA