1.
Braz. dent. j ; 34(1): 12-18, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420578

RESUMO

Abstract This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular cross-section and manufactured from Blue and Gold thermal treatments were used (n=20). The torsional test was performed in the 3 mm from the tip of the instrument according to ISO 3630-1. The torsional test evaluated the torsional strength and angular deflection to failure at room temperature (21°C ± 1° C) and body temperature (36°C ±1°C). The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using an unpaired t test for inter and intra-group comparison and the level of significance was set at 5%. The results showed that the body temperature did not affect the torsional strength and angular deflection of the instruments when compared with room temperature (P>0.05). However, at body temperature, the Blue NiTi instruments presented significantly lower angular deflection in comparison with Gold NiTi instruments (P<0.05). There was no significant difference regarding the torsional strength of the instruments at body temperature (P>0.05). The temperature did not affect the torsional strength of the instruments manufactured from Blue and Gold technology. However, the Blue NiTi instruments presented significantly lower angular deflection than Gold instruments at 36°C temperature.


Resumo O objetivo deste estudo foi avaliar a influência da temperatura nas propriedades de torção (resistência à torção e deflexão angular) de dois instrumentos rotatórios experimentais de NiTi fabricados com secção triangu.ar e tratamentos térmicos Blue e Gold. Quarenta instrumentos experimentais de NiTi 25.06 com tratamento térmico Blue e Gold foram usados (n= 20). Foi avaliada a resistência torcional e a deflexão angular até a fratura na temperatura ambiente (21°C ± 1°C) e corporal (36°C ± 1°C). O teste torcional foi realizado nos 3 mm da ponta dos instrumentos de acordo com a ISO 3630-1. A superfície fraturada de cada instrumento foi observada pelo microscópio eletrônico de varredura (MEV). Os dados foram analisados por meio do teste t não pareado para a comparação inter e intragrupos e o nível de significância à 5%. Os resultados demonstraram que a temperatura corporal não afetou a resistência a torção e deflexão angular quando comparada com a temperatura ambiente (P>0.05). No entanto, na temperatura de 36°C o instrumento com tratamento térmico Blue apresentou menor deflexão angular quando comparado com o Gold (P<0.05). Não houve diferença significante entre os dois instrumentos em relação a resistência à torção. A temperatura corporal não modificou a resistência torcional dos instrumentos fabricados com tecnologia Blue e Gold. No entanto, os instrumentos com NiTi Blue apresentaram menor deflexão angular do que o Gold a 36°C.

2.
J. appl. oral sci ; 31: e20230005, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1440411

RESUMO

Abstract Irrigation solutions might affect dentin surface characteristics and, consequently, endodontic sealers adhesion. Objective This study analyzed the effect of different final irrigation protocols on push-out bond strength (BS) of AH Plus to dentin seven days and 20 months after obturation. Scanning electron micrographs were obtained from the dentin surface of one sample/group after final irrigation. Methodology Canals of bovine incisors were instrumented and received final irrigation with (n=21): G1 - 2.5% sodium hypochlorite (NaOCl) + distilled water; G2 - 2.5% NaOCl + 17% EDTA; G3 - 2.5% NaOCl + 17% EDTA + 2.5% NaOCl; G4 - 2.5% NaOCl + 17% EDTA + 2% chlorhexidine (CHX); G5 - mixture 5% NaOCl + 18% etidronate (HEDP); and G6 - mixture 5% NaOCl + 10% tetrasodium EDTA (Na4EDTA). After irrigation, one root/group was split and images were obtained by scanning electron microscopy (SEM). The other 20 roots/group were filled with only AH Plus sealer. Three slices/root were used for push-out assessment seven days and 20 months after obturation. One-way analysis of variance and Tukey (α<0.05) were used to compare the results among experimental groups, and unpaired t-test (α<0.05) was used to compare the results of the same group over time. Results The photomicrographs showed that, excepting G1, all groups completely removed the smear layer from the samples. In G2 and G4, the opening of the dentin tubules enlarged. In G3, erosion was observed in the peritubular and intertubular dentin. Values of the BS in the seven days were G2=G3=G4=G5>G6=G1 and in the 20 months were G3=G5>G6=G4>G1=G2. G3, G5, and G6 presented values of BS in 20 months similar to the values of seven days (P>0.05). Conclusions The final irrigation protocols tested produced dentin surfaces with different characteristics. Only G3 and G5 presented high BS values that were stable over time.

3.
Braz Oral Res ; 36: e085, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35703710

RESUMO

The aim of this study was to evaluate the quality of curved root canal preparation, torsional fatigue, and cyclic fatigue of rotary systems manufactured with different NiTi alloys. Ninety single-rooted canals with curvatures of 15° to 30o were scanned and divided into three groups according to the rotary system used: BT-Race (BTR) - 10.06, 35.00, 35.04; SequenceRotaryFile (SRF) - 15.04, 25.06, 35.04; and ProDesignLogic (PDL) - 25.01, 25.06, 35.05. Each system was used on three specimens. The teeth were prepared, scanned, and analyzed to assess increase in volume, transportation, and centering ability of the root canal. Torsional fatigue of glide path instruments (BTR 10.06, SRF 15.04 and PDL 25.01) and cyclic fatigue of the finishing instrument (BTR 35.04, SRF 35.04 and PDL 35.05) were obtained by analyzing completely new instruments (n = 10) and instruments after they had been used three times (n = 10). After the torsional and cyclic fatigue tests, the fractured surface of the new and used instruments were examined by scanning electron microscopy. Increase in volume, canal transportation, and centering ability showed no significant differences among the groups (p > 0.05). The torsional test showed that SRF 15.04 produced the highest torque values for both new and used instruments, followed by PDL 25.01 and BTR 10.06 (p < 0.05). PDL 25.01, both new and used, exhibited higher values of angular deflection followed by SRF 15.04 and BTR 10.06 (p < 0.05). As regards cyclic fatigue, use of PDL 35.05, both new and used, required a longer time and larger number of cycles than did SRF 35.04 and BTR 35.04 (p < 0.05). Clinical use affected the torsional fatigue of BTR; however, cyclic fatigue was not significantly affected (p < 0.05). All rotary systems were able to prepare the curved canals satisfactorily and were used safely on the three specimens. Relative to torsional fatigue, SRF 15.04 exhibited a higher torque, and PDL 25.01, higher angular deflection. BTR 10.06 was the most affected by clinical use. PDL 35.05 showed greater resistance to cyclic fatigue.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Níquel , Estresse Mecânico , Titânio , Torção Mecânica
4.
J. res. dent ; 10(2): 16-20, apr.-jun2022.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1395878

RESUMO

Internal inflammatory root resorption (IIRR) can occur as a serious complication of dental trauma which leads to progressive loss of the root structure. An early diagnosis could influence the therapeutic approach, but endodontic treatment becomes a challenge with a doubtful prognosis. The present report described an unusual clinical presentation of an IIRR with perforation resulting from a trauma four years previous. A 15-year-old female patient was presented to our service with pain in the maxillary incisor region. Intraoral radiography revealed a large radioloucent area compatible with IIRR, communicating with the periodontium in the middle third on the distal root face of the right central incisor. The root canal of the right central incisor was chemo-mechanically prepared. The calcium hydroxide (CH) intracanal medication was used and renewed periodically four times. The root canal was filled only in the cervical region to the level of resorption by the inverted gutta-percha cone technique. Clinically and radiographically, all follow-up examinations revealed an asymptomatic tooth, evidencing periapical tissue repair and new bone formation. The tooth remained asymptomatic 3 years afterwards. The present case report supports the idea of executing satisfactory intracanal decontamination by chemo-mechanical preparation, thus creating a favourable environment for tissue repair.


Assuntos
Humanos , Feminino , Tratamento do Canal Radicular , Necrose da Polpa Dentária , Reabsorção da Raiz , Hidróxido de Cálcio
5.
Braz. oral res. (Online) ; 36: e085, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1384205

RESUMO

Abstract The aim of this study was to evaluate the quality of curved root canal preparation, torsional fatigue, and cyclic fatigue of rotary systems manufactured with different NiTi alloys. Ninety single-rooted canals with curvatures of 15° to 30o were scanned and divided into three groups according to the rotary system used: BT-Race (BTR) - 10.06, 35.00, 35.04; SequenceRotaryFile (SRF) - 15.04, 25.06, 35.04; and ProDesignLogic (PDL) - 25.01, 25.06, 35.05. Each system was used on three specimens. The teeth were prepared, scanned, and analyzed to assess increase in volume, transportation, and centering ability of the root canal. Torsional fatigue of glide path instruments (BTR 10.06, SRF 15.04 and PDL 25.01) and cyclic fatigue of the finishing instrument (BTR 35.04, SRF 35.04 and PDL 35.05) were obtained by analyzing completely new instruments (n = 10) and instruments after they had been used three times (n = 10). After the torsional and cyclic fatigue tests, the fractured surface of the new and used instruments were examined by scanning electron microscopy. Increase in volume, canal transportation, and centering ability showed no significant differences among the groups (p > 0.05). The torsional test showed that SRF 15.04 produced the highest torque values for both new and used instruments, followed by PDL 25.01 and BTR 10.06 (p < 0.05). PDL 25.01, both new and used, exhibited higher values of angular deflection followed by SRF 15.04 and BTR 10.06 (p < 0.05). As regards cyclic fatigue, use of PDL 35.05, both new and used, required a longer time and larger number of cycles than did SRF 35.04 and BTR 35.04 (p < 0.05). Clinical use affected the torsional fatigue of BTR; however, cyclic fatigue was not significantly affected (p < 0.05). All rotary systems were able to prepare the curved canals satisfactorily and were used safely on the three specimens. Relative to torsional fatigue, SRF 15.04 exhibited a higher torque, and PDL 25.01, higher angular deflection. BTR 10.06 was the most affected by clinical use. PDL 35.05 showed greater resistance to cyclic fatigue.

6.
Dent. press endod ; 11(3): 83-86, Sept-Dec.2021. Ilus
Artigo em Inglês | LILACS | ID: biblio-1379839

RESUMO

Introdução: Muitas substâncias têm sido utilizadas como irrigantes e curativos intracanal nos tratamentos de dentes com rizogênese incompleta, visando obter a regeneração pulpar. A clorexidina a 2% em associação com hidróxido de cálcio P.A. pode ser uma alternativa. Métodos: No presente caso clínico, o dente #45 com periodontite apical, em um paciente com 13 anos de idade, foi tratado com solução de clorexidina a 2% como irrigante. A clorexidina na forma de gel a 2% foi utilizada como auxiliar da instrumentação e, em associação com o hidróxido de cálcio, foi utilizada como curativo durante 14 dias. Após esse período, o canal foi irrigado com solução fisiológica e, sob anestesia alveolar mandibular, uma lima K #70 foi utilizada ultrapassando levemente o ápice, para causar sangramento. Após observar que o sangue dentro dos canais alcançou a porção cervical, o cimento biocerâmico MTA Branco foi colocado na porção cervical do canal. Resultados: A apicificação e o desenvolvimento da raiz em comprimento e largura puderam ser observados já no controle de três meses, e continuaram até a última revisão, no controle de um ano. Alterações de cor não foram observadas nese período de acompanhamento. Conclusões: A clorexidina associada ao hidróxido de cálcio pode ser uma alternativa aos procedimentos de regeneração pulpar (AU).


Introduction: Many substances have been used as irrigating solutions to promote pulp regeneration and root development in teeth with incomplete rhizogenesis. The use of 2% chlorhexidine as an irrigating solution in association with Calcium Hydroxide could be an alternative. Methods: In the case of the patient, a 13-year-old boy, here presented, tooth 45 with apical periodontitis was treated with 2% Chlorhexidine solution as irrigant adjuvant to instrumentation, in association with Calcium Hydroxide used as a dressing for 14 days. After this period, the canal was cleaned with a physiological solution and under mandibular alveolar anesthesia, a # 70 K file was used slightly over the apex to cause bleeding. After observing that blood inside the canals had reached the cervical portion. White MTA was placed in the cervical portion of the canal. Results: Induced apexification and development of increasing root length and width could already be observed in the three-month control exam, and this continued until the last review in the one-year control exam. No color changes were observed in this follow-up period. Conclusions: Chlorhexidine and calcium hydroxide could be used as an alternative to pulp regeneration procedures (AU).


Assuntos
Humanos , Periodontite Periapical , Hidróxido de Cálcio , Clorexidina , Endodontia Regenerativa , Relatório de Pesquisa
7.
J Endod ; 46(11): 1771-1775, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32818567

RESUMO

INTRODUCTION: The aim of this study was to evaluate the cyclic fatigue resistance of different heat-treated nickel-titanium reciprocating instruments in 2 different situations: new and used instruments after preparing 3 curved canals. METHODS: A total sample of 60 nickel-titanium instruments of 3 systems (n = 20 per system) were used in this study: ProDesign R (tip 25, 0.06 taper; Easy Dental Equipment, Belo Horizonte, Brazil), Reciproc Blue (tip 25, 0.08v taper; VDW, Munich, Germany), and WaveOne Gold (tip 25, 0.07v taper; Dentsply Sirona, Ballaigues, Switzerland). Thirty new instruments (n = 10 per system) were used to prepare 90 curved single-rooted mandibular premolars (n = 30). Each instrument was used to prepare 3 root canals, and after each canal preparation the instrument was ultrasonic cleaned and submitted to autoclave sterilization procedures. The other 30 instruments (n = 10 per system) were kept without use. Then, the new and used instruments were subjected to the cyclic fatigue test in an artificial canal with a 30° angle and a 5-mm radius of curvature. The time and number of cycles to fatigue were recorded. Data were analyzed using the unpaired t test for intragroup comparison. For intergroup comparison, analysis of variance and the Tukey test for multiple comparisons were used. RESULTS: The intergroup comparison of new instruments showed that ProDesign R had the highest cyclic fatigue resistance followed by Reciproc Blue and WaveOne Gold (P < .05). Regarding the used instruments, WaveOne Gold had the lowest cyclic fatigue resistance (P < .05). The intragroup comparison between new and used instruments showed that WaveOne Gold and ProDesign R presented a significant reduction in the cyclic fatigue resistance after simulated clinical use (P < .05); no difference was found with the Reciproc Blue instruments (P > .05). CONCLUSIONS: ProDesign R had the highest cyclic fatigue resistance, whereas WaveOne Gold had the lowest for new and used instruments. Simulated clinical use affected the cyclic fatigue resistance of ProDesign R and WaveOne Gold but not of Reciproc Blue instruments.


Assuntos
Níquel , Titânio , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento
8.
Dent. press endod ; 10(1): 38-42, Jan-Apr2020. Tab, Ilus
Artigo em Inglês | LILACS | ID: biblio-1344157

RESUMO

Avaliar, em micro-CT, diferentes métodos de inserção da pasta de hidróxido de cálcio para preenchimento de canais laterais simulados em blocos de acrílico. Métodos: Foram utilizados 72 blocos de acrílico com canais laterais simuladas nas porções cervical, média e apical, os quais foram preenchidos com a pasta de hidróxido de cálcio de acordo com os seguintes métodos (n=12): Grupo 1 - lima tipo K #30; Grupo 2 - espiral de Lentulo; Grupo 3 - agitação ultrassônica; Grupo 4 - agitação sônica com EndoActivator; Grupo 5 - seringa + Capillari TIPS; e Grupo 6 - agitação com EasyClean em baixa rotação. Para os grupos que receberam agitação, o canal principal foi preenchido com a pasta utilizando seringa e Capillari Tips. Antes e após o preenchimento, os dentes foram escaneados em micro-CT (SkyScan 1174) e as imagens obtidas foram comparadas utilizando-se o software CTan. O volume de medicação intracanal no interior dos canais simulados foi mensurado e, em seguida, obtida a porcentagem de penetração. Os dados foram submetidos à comparação estatística (p<0,05). Resultados: Os grupos EndoActivator e ultrassom apresentaram resultados significativamente melhores do que a lima #30 nos três níveis analisados, assim como o EasyClean nos terços cervical e médio, e a Lentulo no terço apical, em relação ao Grupo 1 (p <0,05). Nas demais comparações e na análise intragrupos, não houve diferenças significativas (p>0,05). Conclusão: Os métodos de agitação da medicação intracanal, especialmente o ultrassom, proporcionaram uma maior porcentagem de penetração dela em canais laterais simulados (AU).


Objective: The objective of this study was to analyze, in micro-CT, the capacity of different methods for insertion of calcium hydroxide paste in the filling of lateral canals simulated in blocks of acrylic. Methods: A total of 72 acrylic blocks with lateral canals simulated in the coronal, middle and apical portions, were used and filled with calcium hydroxide paste, according to the following methods (n = 12): Group 1 - #30 K-file; Group 2 - Lentulo spiral; Group 3 - Ultrasonic agitation; Group 4 - Sonic agitation with EndoActivator; Group 5 - Syringe + Capillary Tips; Group 6 - Agitation with Easy Clean at low speed. For the groups that received agitation, the blocks were filled with the aid of a syringe and Capillary Tips. Each sample was scanned with SkyScan 1174, before and after the filling procedures, and the volume of calcium hydroxide was measured using CTAN software. The percentage of penetration of intracanal medication inside the simulated canals was calculated. Data were statistically compared (p < 0.05). Results: The agitation with EndoActivator and ultrasonic insert promoted a greater penetration of paste with significant statistical differences in relation to the #30 K-file group in the 3 levels analyzed (p < 0.05). Other statistical differences occurred in the comparison between the Easy Clean group and #30 K-file group in the coronal and middle thirds and in the comparison between Lentulo spiral group and #30 K-file group in the apical (p < 0.05). Conclusion: Methods which use agitation devices , such as ultrasonic insert, promoted higher filling of calcium hydroxide in simulated lateral canals (AU).


Assuntos
Pulpite , Técnicas In Vitro , Hidróxido de Cálcio , Ultrassonografia , Equipamentos e Provisões
9.
Dent. press endod ; 9(2): 71-75, maio 2019. Ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1024858

RESUMO

Objetivo: o objetivo deste artigo é relatar um caso clínico em que um instrumento fraturado e a guta-percha extravasada foram removidos via canal. Relato de caso: paciente do sexo masculino, com 38 anos de idade, foi encaminhado para avaliação do incisivo lateral superior direito (dente #12). O paciente apresentava dor à palpação na região apical e ausência de sintomatologia espontânea. O exame radiográfico revelou a presença de cone de guta-percha extravasado, uma espiral de Lentulo fraturada, além de lesão periapical no dente #12. O retratamento endodôntico foi o procedimento de escolha, na tentativa de remover os dois materiais. A espiral de Lentulo foi removida com Masserann Endokit; e o cone de guta-percha, utilizando limas Hedstroen. Após realizar a instrumentação e o preenchimento do conduto com pasta de hidróxido de cálcio com iodofórmio, constatou- se a presença de reabsorção no terço apical. Depois de dois meses, observou-se redução da lesão; utilizou-se, então, MTA na região da reabsorção, e o conduto foi obturado com cone de guta-percha e cimento endodôntico Sealer 26. Conclusão: controles clínicos e radiográficos foram realizados após dois, quatro e oito anos, demonstrando reparo na região apical e ausência de sintomatologia (AU).


The objective of this article was to report a clinical case of finding a fractured instrument and over-extended guttapercha of a tooth, which were removed via the canal. The patient, a 38-year-old man, was referred for treatment of the right maxillary lateral incisor (tooth 7). The patient presented pain on palpation at the apical level and absence of spontaneous symptomatology. Radiographic examination revealed the presence of a over-extended gutta-percha cone, a fractured Lentulo spiral and periapical lesion in tooth 7. Endodontic retreatment was the chosen procedure in an attempt to remove both materials. The Lentulo spiral was removed by means of the Masserann Endokit, and the gutta-percha cone by using Hedstroen files. While performing instrumentation, and filling the canal with calcium hydroxide with iodoform, the presence of resorption in the apical third was verified. After 2 months, reduction of the lesion was observed, thus MTA was placed in the area of resorption and the remainder of the canal was filled with a gutta-percha cone and Sealer 26 cement. Clinical and radiographic controls performed after 2, 5 and 7 years showed repair of the area and absence of symptomatology (AU).


Assuntos
Humanos , Masculino , Adulto , Periodontite Periapical , Materiais Restauradores do Canal Radicular , Preparo de Canal Radicular , Guta-Percha , Hidróxido de Cálcio , Retratamento , Pinos Dentários
10.
Dent. press endod ; 8(1): 34-40, Apr-Jun. 2018. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-883679

RESUMO

Objetivo: o objetivo do presente trabalho é discutir a importância da variação do ângulo vertical na radiografía periapical, em algumas situações clínicas especiais. Métodos: foram consultadas algumas fontes com o intuito de analisar a utilidade dessa técnica na Endodontia. Resultados: a variação do ângulo vertical na radiografía periapical pode ser empregada em diversas situações clínicas na Endodontia, tais como: a sobreposição do arco zigomático sobre os ápices dos molares superiores, para visualizar ápices muito finos, em casos de fraturas radiculares transversais, para evitar sobreposições das asas dos grampos do isolamento absoluto sobre os ápices dos dentes, durante o tratamento endodôntico. Também, poder ser útil para a detecção de obstruções cervicais do canal radicular e pinos intrarradiculares curtos, em dentes portadores de coroas metálicas, onde é difícil sua visualização. Conclusões: o uso adequado da variação na angulação vertical pode auxiliar na resolução satisfatória desses casos.


Assuntos
Humanos , Masculino , Feminino , Endodontia , Padrões de Prática Odontológica , Radiografia Dentária/métodos , Radiologia
12.
Clin Oral Investig ; 22(4): 1865-1871, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29224061

RESUMO

OBJECTIVES: The aim of this study was to evaluate the cyclic and torsional fatigue resistance of the reciprocating single-file systems Reciproc Blue 25.08 (VDW GmbH, Munich, Germany), Prodesign R 25.06 (Easy Dental Equipment, Belo Horizonte, Brazil), and WaveOne Gold 25.07 (Dentsply/Tulsa Dental Specialties, Tulsa, OK, USA). MATERIALS AND METHODS: Sixty reciprocating instruments of the systems Reciproc Blue R25 (RB #25 .08 taper), Prodesign R (PDR #25 .06 taper), and WaveOne Gold (WOG #25 .07 taper) (n = 20) were used. Cyclic fatigue resistance testing was performed by measuring the time to failure in an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius located 5 mm from the tip (n = 10). The torsional test (ISO 3630-1) evaluated the torque and angle of rotation at failure of new instruments (n = 10) in the portion 3 mm from the tip. The fractured surface of each fragment was also observed using scanning electron microscopy (SEM). In addition, a supplementary examination was performed to measure the cross-sectional area of each instrument 3 and 5 mm from the tip. The data were analyzed using one-way ANOVA and Tukey's test, and the level of significance was set at 5%. RESULTS: The cyclic fatigue resistance values of PDR 25.06 were significantly higher (P < 0.05). RB 25.08 showed higher fatigue resistance than WOG 25.07 (P < 0.05). The torsional test showed that PDR 25.06 had lower torsional strength (P < 0.05). No differences were observed between RB 25.08 and WOG 25.07 (P > 0.05). PDR 25.06 showed higher angular rotation values than RB 25.08 and WOG 25.07 (P < 0.05). RB 25.08 presented higher angular rotation than WOG 25.07 (P < 0.05). The cross-sectional area analysis showed that PDR 25.06 presented the smallest cross-sectional areas at 3 and 5 mm from the tip (P < 0.05). CONCLUSION: PDR 25.06 presented the highest cyclic fatigue resistance and angular rotation until fracture compared to RB 25.08 and WOG 25.07. In addition, RB 25.08 and WOG 25.07 had higher torsional strength than PDR 25.06. CLINICAL RELEVANCE: In endodontic practice, thermally treated reciprocating instruments have been used for the root canal preparation of curved and constricted canals; therefore, these instruments should present high flexibility and suitable torsional strength to minimize the risk of instrument fracture.


Assuntos
Ligas Dentárias/química , Instrumentos Odontológicos , Análise de Falha de Equipamento , Níquel/química , Titânio/química , Desenho de Equipamento , Temperatura Alta , Teste de Materiais , Microscopia Eletrônica de Varredura , Torque , Torção Mecânica
13.
J. appl. oral sci ; 26: e2017115, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893690

RESUMO

Abstract Objective This study aimed to analyze the following physicochemical properties: radiopacity, final setting time, calcium release, pH change, solubility, water sorption, porosity, surface morphology, and apatite-forming ability of two calcium silicate-based materials. Material and methods We tested MTA Repair HP and MTA Vitalcem in comparison with conventional MTA, analyzing radiopacity and final setting time. Water absorption, interconnected pores and apparent porosity were measured after 24-h immersion in deionized water at 37°C. Calcium and pH were tested up to 28 d in deionized water. We analyzed data using two-way ANOVA with Student-Newman-Keuls tests (p<0.05). We performed morphological and chemical analyses of the material surfaces using ESEM/EDX after 28 d in HBSS. Results MTA Repair HP showed similar radiopacity to that of conventional MTA. All materials showed a marked alkalinizing activity within 3 h, which continued for 28 d. MTA Repair HP showed the highest calcium release at 28 d (p<0.05). MTA Vitalcem showed statistically higher water sorption and solubility values (p<0.05). All materials showed the ability to nucleate calcium phosphate on their surface after 28 d in HBSS. Conclusions MTA Repair HP and MTA Vitalcem had extended alkalinizing activity and calcium release that favored calcium phosphate nucleation. The presence of the plasticizer in MTA HP might increase its solubility and porosity. The radiopacifier calcium tungstate can be used to replace bismuth oxide.


Assuntos
Óxidos/química , Silicatos/química , Compostos de Cálcio/química , Compostos de Alumínio/química , Valores de Referência , Solubilidade/efeitos dos fármacos , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo , Teste de Materiais , Fosfatos de Cálcio/química , Água/química , Cálcio/química , Reprodutibilidade dos Testes , Análise de Variância , Porosidade/efeitos dos fármacos , Estatísticas não Paramétricas , Combinação de Medicamentos , Concentração de Íons de Hidrogênio
14.
J. appl. oral sci ; 25(6): 641-649, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893677

RESUMO

Abstract The aim of this study was evaluate the influence of ultrasonic activation (UA) of AH Plus to improve canal and isthmus filing, and analyse the antimicrobial effect against Enterococcus faecalis within dentinal tubules. Material and Methods: Thirty mesial roots of mandibular first molars were selected and divided into 2 groups (n = 15): with and without UA of the sealer. Then the root canals were filled by using the single cone technique, and the specimens were sectioned at 2, 4 and 6 mm from the apex for stereomicroscope and confocal laser scanner microscopy (CLSM) analysis. In addition, 30 bovine incisors were contaminated with Enterococcus faecalis and divided into 3 groups (n = 10). The specimens were obturated by using the single cone technique with (G1) and without (G2) UA of the sealer and G3 as the control group. All were sectioned into 6 mm-long cylinders and stained with LIVE/DEAD to assess bacterial viability by CLSM. Results: The UA of the sealer significantly reduced the presence of unfilled areas in the canal and isthmus area in all sections (p<0.05), and there was a significant increase in sealer penetration in both canals and isthmuses (p<0.05). As regards gaps, a significant reduction was found at 2 and 6 mm in the isthmus area of the UA group (p<0.05). Moreover, UA of the sealer significantly reduced bacterial viability in the superficial dentine when compared with the other groups (p<0.05). Conclusion: Ultrasonic activation of the AH Plus sealer promoted a better quality of root canal filling and increased the intratubular penetration of sealer, especially in the isthmus area. Additionally, ultrasonic activation of the sealer increased the intradentinal antimicrobial action against Enterococcus faecalis, mainly in the superficial dentine of the root canal.


Assuntos
Humanos , Materiais Restauradores do Canal Radicular/farmacologia , Obturação do Canal Radicular/métodos , Ultrassom , Enterococcus faecalis/efeitos dos fármacos , Cavidade Pulpar/microbiologia , Resinas Epóxi , Microscopia Confocal
15.
Dent. press endod ; 7(1): 20-25, Jan-Apr. 2017. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-846721

RESUMO

A presença de uma alteração óssea periapical na região anterior da maxila, mais precisamente entre os incisivos superiores, pode ser erroneamente confundida com uma periodontite apical (AP) ou um cisto do ducto nasopalatino (CDNP). O diagnóstico diferencial é de suma importância para definir o tratamento adequado. O exame clínico, mais especificamente o teste de sensibilidade pulpar, é de suma importância, pois dentes portadores de periodontite apical não respondem ao teste, diferentemente dos casos de cisto do ducto nasopalatino. Uma paciente com 48 anos de idade, sexo feminino, compareceu à clínica de Endodontia com inchaço na região de palato e fundo de sulco anterior, relatando dor aguda ao redor dos incisivos centrais, sendo submetida a exames clínicos e radiográficos. Os exames clínicos mostraram ausência de vitalidade pulpar e as radiografias evidenciaram uma área radiolúcida simétrica na região de linha média, que poderia ser uma lesão endodôntica ou um CDNP. Durante o tratamento endodôntico, foi observada comunicação entre o canal radicular e a lesão periapical, sugerindo uma lesão de origem endodôntica. O tratamento endodôntico foi realizado e, após oito meses de acompanhamento, foi possível observar regressão da lesão. Este caso evidencia a importância de um diagnóstico diferencial preciso entre PA e CDNP, para planejar o tratamento adequado e favorecer o reparo dos tecidos periodontais.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Diagnóstico Bucal , Endodontia , Cistos não Odontogênicos , Doenças Periapicais , Periodontite Periapical
16.
Rev. Salusvita (Online) ; 36(1): 123-140, 2017. tab
Artigo em Português | LILACS | ID: biblio-876191

RESUMO

Introdução: a irrigação é uma das etapas essenciais no preparo biomecânico e, buscando aumentar a eficiência desta, novos métodos vem sendo empregados no intuito de melhorar a ação e o alcance das soluções irrigadoras. Objetivo: analisar a eficácia do sistema EndoActivator em várias etapas do tratamento endodôntico. Resultados e discussão: apesar de diferenças de metodologias na literatura, o EndoActivator apresentou bons resultados em comparação com a irrigação convencional quando empregado em diferentes fases do tratamento endodôntico. Conclusão: o sistema EndoActivator é seguro e eficaz durante o preparo biomecânico, porém, assim como outros dispositivos de agitação mecânica da solução irrigante, não é capaz de promover completa limpeza dos canais radiculares.


Introduction: the irrigation is an essential part of biomechanical preparation and seeking increase the efficiency of this, new methods have been used in order to expand the effect of irrigating solutions, and promote the reach for areas with difficult access. Objective: the objective of this literature review was to analyze the effectiveness of the EndoActivator system in several stages of endodontic treatment. Results and Discussion: despite differences in methodologies in the literature, the EndoActivator presented good results in comparison to conventional irrigation when used in different phases of endodontic treatment. Conclusion: the EndoActivator system is safe and effective during biomechanical preparation, but, like other mechanical agitation devices of the irrigating solution, it is not able to promote complete cleaning to root canals.


Assuntos
Irrigantes do Canal Radicular/análise , Tratamento do Canal Radicular/tendências , Preparo de Canal Radicular/instrumentação , Literatura de Revisão como Assunto , Camada de Esfregaço , Endodontia/instrumentação
17.
RGO (Porto Alegre) ; 64(4): 382-386, Oct.-Dec. 2016. tab
Artigo em Inglês | LILACS | ID: biblio-842350

RESUMO

ABSTRACT Objective: This study was aimed at evaluating the influence of cervical preflaring using LA-Axxes No. 1 bur (SybronEndo, Glendora, USA) or S1 and SX ProTaper files (Dentsply Maillefer, Ballaigues, Switzerland) on the accuracy of the Electronic Apex Locators (EALs): Root ZX mini (J. Morita Corporation, Tokyo, Japan), and Joypex 5 (Denjoy, Changsha, China). Methods: Thirty mandibular incisors were accessed, and the root canal length (RCL) was determined with a K-file #15, with the aid of a stereo microscope. Afterwards, the specimens were divided into 2 groups (n = 15) referring to the cervical preflaring with LA-Axxess or ProTaper files. The teeth were embedded in alginate and the RCL was determined by the EALs before and after preflaring. Data were classified into: accurate, if the difference in RCL measurement were ≤0.05 mm; and inaccurate, if the difference were >0.5 mm or beyond the RCL. Results: McNemar's test (α<0.05) was used to detect differences in the accuracy of the EALs before and after each preflaring with different instruments, and to detect difference in accuracy among devices. No differences were found concerning the accuracy of the EALs (P > 0.05) after the cervical preflaring, regardless of the used instrument. Conclusion: The preflaring procedure increased the number of accurate measurements for both EALs, with statistical difference for Joypex 5 when the preflaring was performed with LA-Axxess. However, after the cervical preflaring, the EALs showed similar accuracy, regardless of the used instrument.


RESUMO Objetivo: Avaliar a influência do preparo cervical utilizando a broca LA-Axxess nº 1 (SybronEndo, Glendora, EUA) ou os instrumentos ProTaper S1 e SX (Dentsply Maillefer, Ballaigues, Suíça) na precisão dos Localizadores Apicais Eletrônicos (LAEs): Root ZX mini (J. Morita Corporation, Tóquio, Japão) e Joypex 5 (Denjoy, Changsha, China). Métodos: Trinta incisivos inferiores foram acessados e o comprimento do canal radicular (CCR) determinado com uma lima K #15 com o auxílio de um estereomicroscópio. Em seguida, os dentes foram distribuídos em dois grupos (n=15) referentes ao preparo cervical com LA-Axxess ou instrumentos ProTaper. Os dentes foram incluídos em alginato e o CCR determinado pelos LAEs antes e após o preparo cervical. Os dados foram classificados em: precisos, se a diferença na medida do CCR era ≤ 0,05 mm; e imprecisos, se a diferença era >0,5 mm ou estava além do CCR. Resultados: O teste de McNemar (α<0.05) foi utilizado para detectar diferenças na precisão dos LAEs antes e após o preparo com os diversos instrumentos, e para detectar diferenças na precisão entre os aparelhos. Não foram identificadas diferenças na precisão entre os dois LAEs (P>0,05) após o preparo cervical, indiferente do instrumento utilizado. Conclusão: O preparo cervical aumentou o número de medições precisas dos LAEs, com diferença estatística para Joypex 5 após o uso da LA-Axxess, contudo os aparelhos apresentaram precisão similar após o preparo cervical, indiferente do instrumento utilizado.

18.
J. appl. oral sci ; 24(5): 535-542, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-797979

RESUMO

ABSTRACT The knowledge of the internal anatomy of three-rooted mandibular molars may help clinicians to diagnose and plan the root canal treatment in order to provide adequate therapy when this variation is present. Objectives: To determine the prevalence of three-rooted mandibular molars in a Brazilian population using cone beam computed tomography (CBCT) and to analyze the anatomy of mandibular first molars with three roots through micro-CT. Material and Methods: CBCT images of 116 patients were reviewed to determine the prevalence of three-rooted first mandibular molars in a Brazilian subpopulation. Furthermore, with the use of micro-CT, 55 extracted three-rooted mandibular first molars were scanned and reconstructed to assess root length, distance between canal orifices, apical diameter, Vertucci's classification, presence of apical delta, number of foramina and furcations, lateral and accessory canals. The distance between the orifice on the pulp chamber floor and the beginning of the curvature and the angle of canal curvature were analyzed in the distolingual root. Data were compared using the Kruskal-Wallis test (α=0.05). Results: The prevalence of three-rooted mandibular first molars was of 2.58%. Mesial roots showed complex distribution of the root canal system in comparison to the distal roots. The median of major diameters of mesiobuccal, mesiolingual and single mesial canals were: 0.34, 0.41 and 0.60 mm, respectively. The higher values of major diameters were found in the distobuccal canals (0.56 mm) and the lower diameters in the distolingual canals (0.29 mm). The lowest orifice distance was found between the mesial canals (MB-ML) and the highest distance between the distal root canals (DB-DL). Almost all distal roots had one root canal and one apical foramen with few accessory canals. Conclusions: Distolingual root generally has short length, severe curvature and a single root canal with low apical diameter.


Assuntos
Humanos , Masculino , Feminino , Raiz Dentária/anatomia & histologia , Mandíbula/anatomia & histologia , Dente Molar/anatomia & histologia , Valores de Referência , Raiz Dentária/diagnóstico por imagem , Brasil , Estatísticas não Paramétricas , Anatomia Transversal , Imageamento Tridimensional , Polpa Dentária/anatomia & histologia , Polpa Dentária/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Variação Anatômica , Mandíbula/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Odontometria
19.
Braz. dent. j ; 27(5): 568-572, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828051

RESUMO

Abstract The aim of this study was to evaluate the influence of different passive ultrasonic irrigation protocols on the removal of debris in artificially created grooves in the cervical, middle and apical root thirds. Forty extracted bovine incisor roots were instrumented to 1 mm of the root apex with a R50 Reciproc instrument and irrigated with 2.5% sodium hypochlorite. The roots were then inserted in a muffle and cleaved into two hemisections. Grooves (3-mm long) were done at 2, 7 and 12 mm from the root apex in one hemisection and filled with dentinal debris. The hemisections were regrouped into the muffle and divided into 4 groups (n=10) according to the final irrigation protocol: Control group: 3x20 s using a #30 gauge needle without agitation of the irrigating solution; Group PUI-s (static passive ultrasonic irrigation): 3x20 s of passive ultrasonic irrigation with the tip of the insert maintained static on the apical third; Group PUI-t (passive ultrasonic irrigation per third): 20 s of PUI in each third; Group PUI-d (passive dynamic ultrasonic irrigation): 3x20 s of PUI dynamically moving the insert in the whole extent of the root canal. In all groups, was used a total of 6 mL of 2.5% sodium hypochlorite as irrigant. After these procedures, the grooves were analyzed with a stereomicroscope and assigned scores as regards removal of the debris. The data were analyzed statistically (a=0.05). The results showed a better cleaning in all the groups where the irrigating solution was agitated with ultrasonic device than in the control group (p<0.05). In the apical third, the PUI-d and PUI-s showed similar performance (p>0.05) and a better cleanness than PUI-t (p<0.05). The dynamic and static methods of agitation of the irrigating solution provided more effective cleaning. PUI-d provided the most completely clean grooves suggesting that its use is the most adequate in cases of teeth with complex canal anatomy.


Resumo O objetivo deste estudo foi avaliar a influência de diferentes protocolos de irrigação ultrassônica passiva na remoção de detritos em sulcos artificialmente criados nos terços radiculares cervical, médio e apical. Quarenta raízes de incisivos bovinos extraídos foram instrumentadas a 1 mm do ápice radicular com um instrumento R50 Reciproc e irrigadas com hipoclorito de sódio a 2,5%. As raízes foram então inseridas numa mufla e clivadas em duas hemisecções. Sulcos (3 mm de comprimento) foram feitos a 2, 7 e 12 mm do ápice radicular em uma hemisecção e preenchidos com detritos dentinários. As hemisecções foram reagrupadas na mufla e divididas em 4 grupos (n = 10) de acordo com o protocolo de irrigação final: Grupo controle: 3x20 s usando agulha de calibre #30 sem agitação da solução irrigadora; Grupo PUI-s (static passive ultrasonic irrigation): 3x20 s de irrigação ultra-sônica passiva com a ponta do inserto mantida estática no terço apical; Grupo PUI-t (Irrigação ultrassônica passiva por terço): 20 s de PUI em cada terço; Grupo PUI-d (Irrigação ultrassônica dinâmica): 3x20 s de PUI movendo dinamicamente o inserto em toda extensão do canal radicular. Em todos os grupos, foi utilizado um total de 6 mL de hipoclorito de sódio a 2,5% como irrigante. Após estes procedimentos, os sulcos foram analisadas com um estereomicroscópio e pontuações foram atribuídas quanto à remoção dos detritos. Os dados foram analisados estatisticamente (a=0.05). Os resultados mostraram uma melhor limpeza em todos os grupos onde a solução de irrigação foi agitada com dispositivo ultrassônico do que no grupo controle (p<0,05). No terço apical, o PUI-d e o PUI-s apresentaram performance semelhantes (p>0,05) e melhor limpeza do que o PUI-t (p<0,05). Os métodos dinâmico e estático de agitação da solução de irrigação proporcionaram uma limpeza mais eficaz. O PUID promoveu os sulcos mais completamente limpos sugerindo que seu uso é o mais adequado em casos de dentes com anatomia de canal complexa.


Assuntos
Animais , Bovinos , Dentina/química , Irrigação Terapêutica , Ultrassom
20.
J. appl. oral sci ; 24(3): 291-298, tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-787545

RESUMO

ABSTRACT Sodium hypochlorite (NaOCl) remains the most used irrigation solution during root canal preparation because of characteristics such as wide-spectrum antimicrobial activity and organic tissue dissolution capacity. However, these solutions can alter dentin composition and there is no consensus on the optimal concentration of NaOCl to be used. Objectives To determine the organic matter dissolution and changes in dentin chemical composition promoted by different concentrations of NaOCl over time. Material and Methods: Fragments of bovine muscle tissue were weighed before and after 5, 10, and 15 min of immersion in the groups (n=10): G1- 0.9% saline solution; G2- 1% NaOCl; G3- 2.5% NaOCl; and G4- 5% NaOCl. Bovine dentin fragments were subjected to the same irrigants and absorption spectra were collected by Attenuated Total Reflectance of Fourier Transform Infrared Spectroscopy (ATR-FTIR) before and after 0,5, 1, 2, 3, 5, 8, and 10 min of immersion in the solutions. The ratios of the amide III/phosphate and carbonate/phosphate absorption bands were determined. The tissue dissolution and carbonate/phosphate ratios were submitted to the two-way analysis of variance (ANOVA) with Tukey’s multiple-comparison test (α<0.05) and to the one-way analysis of variance with Tukey’s (α<0.05). The amide III/phosphate ratio was analyzed by Friedman test (α<0.05) and the Kruskal-Wallis test with Dunn’s post-hoc (α<0.05). Results The increase in NaOCl concentration and contact time intensified the dissolution of organic matter and dentin collagen with reduction in the amide III/phosphate ratio. Significant differences between all groups (p<0.05) were observed in the dissolution of organic matter at 10 min and in the amide III/phosphate ratio between the saline solution and 5% NaOCl at 5 min. The carbonate/phosphate ratio decreased significantly in G2, G3, and G4 after 0,5 min of immersion (p<0.05), but more alterations did not occur in the subsequent periods (p>0.05). Intergroup differences were not observed in this ratio (p>0.05). Conclusions The increase in the exposure time and in the concentration of NaOCl solution lead to an increase in the tissue dissolution and dentin collagen deproteination. Furthermore, some carbonate ions are removed from the dentin inorganic phase by the NaOCl.


Assuntos
Animais , Bovinos , Hipoclorito de Sódio/química , Dentina/efeitos dos fármacos , Dentina/química , Desinfetantes/química , Valores de Referência , Irrigantes do Canal Radicular/química , Solubilidade/efeitos dos fármacos , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo , Colágeno/efeitos dos fármacos , Espectroscopia de Infravermelho com Transformada de Fourier , Concentração de Íons de Hidrogênio , Imersão , Músculos/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS