Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Front Physiol ; 13: 825433, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35350681

RESUMO

Synchrotron radiation offers unique properties of coherence, utilized in phase-contrast imaging, and high flux as well as a wide energy spectrum which allow the selection of very narrow energy bands of radiation, used in K-edge subtraction imaging (KES) imaging. These properties extend X-ray computed tomography (CT) capabilities to quantitatively assess lung morphology, and to map regional lung ventilation, perfusion, inflammation, aerosol particle distribution and biomechanical properties, with microscopic spatial resolution. Four-dimensional imaging, allows the investigation of the dynamics of regional lung functional parameters simultaneously with structural deformation of the lung as a function of time. These techniques have proven to be very useful for revealing the regional differences in both lung structure and function which is crucial for better understanding of disease mechanisms as well as for evaluating treatment in small animal models of lung diseases. Here, synchrotron radiation imaging methods are described and examples of their application to the study of disease mechanisms in preclinical animal models are presented.

2.
Int J Radiat Oncol Biol Phys ; 112(3): 818-830, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34678432

RESUMO

PURPOSE: This study provides the first experimental application of multiscale 3-dimensional (3D) x-ray phase contrast imaging computed tomography (XPCI-CT) virtual histology for the inspection and quantitative assessment of the late-stage effects of radio-induced lesions on lungs in a small animal model. METHODS AND MATERIALS: Healthy male Fischer rats were irradiated with x-ray standard broad beams and microbeam radiation therapy, a high-dose rate (14 kGy/s), FLASH spatially fractionated x-ray therapy to avoid beamlet smearing owing to cardiosynchronous movements of the organs during the irradiation. After organ dissection, ex vivo XPCI-CT was applied to all the samples and the results were quantitatively analyzed and correlated to histologic data. RESULTS: XPCI-CT enables the 3D visualization of lung tissues with unprecedented contrast and sensitivity, allowing alveoli, vessel, and bronchi hierarchical visualization. XPCI-CT discriminates in 3D radio-induced lesions such as fibrotic scars and Ca/Fe deposits and allows full-organ accurate quantification of the fibrotic tissue within the irradiated organs. The radiation-induced fibrotic tissue content is less than 10% of the analyzed volume for all microbeam radiation therapy-treated organs and reaches 34% in the case of irradiations with 50 Gy using a broad beam. CONCLUSIONS: XPCI-CT is an effective imaging technique able to provide detailed 3D information for the assessment of lung pathology and treatment efficacy in a small animal model.


Assuntos
Terapia por Raios X , Animais , Pulmão/diagnóstico por imagem , Masculino , Ratos , Tomografia Computadorizada por Raios X/métodos , Raios X
3.
Cancers (Basel) ; 13(19)2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34638437

RESUMO

The purpose of this study is to use a multi-technique approach to detect the effects of spatially fractionated X-ray Microbeam (MRT) and Minibeam Radiation Therapy (MB) and to compare them to seamless Broad Beam (BB) irradiation. Healthy- and Glioblastoma (GBM)-bearing male Fischer rats were irradiated in-vivo on the right brain hemisphere with MRT, MB and BB delivering three different doses for each irradiation geometry. Brains were analyzed post mortem by multi-scale X-ray Phase Contrast Imaging-Computed Tomography (XPCI-CT), histology, immunohistochemistry, X-ray Fluorescence (XRF), Small- and Wide-Angle X-ray Scattering (SAXS/WAXS). XPCI-CT discriminates with high sensitivity the effects of MRT, MB and BB irradiations on both healthy and GBM-bearing brains producing a first-time 3D visualization and morphological analysis of the radio-induced lesions, MRT and MB induced tissue ablations, the presence of hyperdense deposits within specific areas of the brain and tumor evolution or regression with respect to the evaluation made few days post-irradiation with an in-vivo magnetic resonance imaging session. Histology, immunohistochemistry, SAXS/WAXS and XRF allowed identification and classification of these deposits as hydroxyapatite crystals with the coexistence of Ca, P and Fe mineralization, and the multi-technique approach enabled the realization, for the first time, of the map of the differential radiosensitivity of the different brain areas treated with MRT and MB. 3D XPCI-CT datasets enabled also the quantification of tumor volumes and Ca/Fe deposits and their full-organ visualization. The multi-scale and multi-technique approach enabled a detailed visualization and classification in 3D of the radio-induced effects on brain tissues bringing new essential information towards the clinical implementation of the MRT and MB radiation therapy techniques.

4.
Front Oncol ; 11: 554668, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34113554

RESUMO

Characterizing nanoparticles (NPs) distribution in multiple and complex metastases is of fundamental relevance for the development of radiological protocols based on NPs administration. In the literature, there have been advances in monitoring NPs in tissues. However, the lack of 3D information is still an issue. X-ray phase-contrast tomography (XPCT) is a 3D label-free, non-invasive and multi-scale approach allowing imaging anatomical details with high spatial and contrast resolutions. Here an XPCT qualitative study on NPs distribution in a mouse brain model of melanoma metastases injected with gadolinium-based NPs for theranostics is presented. For the first time, XPCT images show the NPs uptake at micrometer resolution over the full brain. Our results revealed a heterogeneous distribution of the NPs inside the melanoma metastases, bridging the gap in spatial resolution between magnetic resonance imaging and histology. Our findings demonstrated that XPCT is a reliable technique for NPs detection and can be considered as an emerging method for the study of NPs distribution in organs.

5.
Sci Rep ; 11(1): 4236, 2021 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-33608569

RESUMO

Mechanical ventilation can damage the lungs, a condition called Ventilator-Induced Lung Injury (VILI). However, the mechanisms leading to VILI at the microscopic scale remain poorly understood. Here we investigated the within-tidal dynamics of cyclic recruitment/derecruitment (R/D) using synchrotron radiation phase-contrast imaging (PCI), and the relation between R/D and cell infiltration, in a model of Acute Respiratory Distress Syndrome in 6 anaesthetized and mechanically ventilated New-Zealand White rabbits. Dynamic PCI was performed at 22.6 µm voxel size, under protective mechanical ventilation [tidal volume: 6 ml/kg; positive end-expiratory pressure (PEEP): 5 cmH2O]. Videos and quantitative maps of within-tidal R/D showed that injury propagated outwards from non-aerated regions towards adjacent regions where cyclic R/D was present. R/D of peripheral airspaces was both pressure and time-dependent, occurring throughout the respiratory cycle with significant scatter of opening/closing pressures. There was a significant association between R/D and regional lung cellular infiltration (p = 0.04) suggesting that tidal R/D of the lung parenchyma may contribute to regional lung inflammation or capillary-alveolar barrier dysfunction and to the progression of lung injury. PEEP may not fully mitigate this phenomenon even at high levels. Ventilation strategies utilizing the time-dependence of R/D may be helpful in reducing R/D and associated injury.


Assuntos
Microscopia/métodos , Lesão Pulmonar Induzida por Ventilação Mecânica/diagnóstico por imagem , Lesão Pulmonar Induzida por Ventilação Mecânica/patologia , Raios X , Animais , Biomarcadores , Análise de Dados , Modelos Animais de Doenças , Progressão da Doença , Respiração com Pressão Positiva , Coelhos , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/patologia , Tomografia Computadorizada por Raios X , Lesão Pulmonar Induzida por Ventilação Mecânica/etiologia , Lesão Pulmonar Induzida por Ventilação Mecânica/fisiopatologia
6.
Cureus ; 13(11): e19317, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35223216

RESUMO

Conventional radiotherapy is a widely used non-invasive form of treatment for many types of cancer. However, due to a low threshold in the lung for radiation-induced normal tissue damage, it is of less utility in treating lung cancer. For this reason, surgery is the preferred treatment for lung cancer, which has the detriment of being highly invasive. Non-conventional ultra-high dose rate (FLASH) radiotherapy is currently of great interest in the radiotherapy community due to demonstrations of reduced normal tissue toxicity in lung and other anatomy. This study investigates the effects of FLASH microbeam radiotherapy, which in addition to ultra-high dose rate incorporates a spatial segmentation of the radiation field, on the normal lung tissue of rats. With a focus on fibrotic damage, this work demonstrates that FLASH microbeam radiotherapy provides an order of magnitude increase in normal tissue radio-resistance compared to FLASH radiotherapy. This result suggests FLASH microbeam radiotherapy holds promise for much improved non-invasive control of lung cancer.

7.
Phys Med Biol ; 65(5): 055016, 2020 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-31995530

RESUMO

K-edge subtraction (KES) imaging is a technique able to map a specific element such as e.g. a contrast agent within the tissues, by exploiting the sharp rise of its absorption coefficient at the K-edge energy. Whereas mainly explored at synchrotron radiation sources, the energy discrimination properties of modern x-ray photon counting detectors (XPCDs) pave the way for an implementation of single-shot KES imaging with conventional polychromatic sources. In this work we present an x-ray CT imaging system based on the innovative Pixie-III detector and discrete reconstruction. The results reported here show that a reliable automatic localization of Barium (above a certain concentration) is possible with a few dozens of tomographic projections for a volume having an axial slice of 512 [Formula: see text] 512 pixels. The final application is a routine high-fidelity 3D mapping of a specific element ready for further morphological quantification by means of x-ray CT with potential promising applications in vivo.


Assuntos
Neoplasias da Mama/patologia , Processamento de Imagem Assistida por Computador/métodos , Fótons , Síncrotrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Animais , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Camundongos , Células Tumorais Cultivadas , Raios X , Ensaios Antitumorais Modelo de Xenoenxerto
8.
J Synchrotron Radiat ; 27(Pt 4): 1042-1048, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33566014

RESUMO

Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disorder affecting motor neurons. Pre-clinical studies drive the development of animal models that well mimic ALS disorder and enable both the dissection of disease processes and an early assessment of therapy efficacy. A comprehensive knowledge of neuronal and vascular lesions in the brain and spinal cord is an essential factor to understand the development of the disease. Spatial resolution and bidimensional imaging are important drawbacks limiting current neuroimaging tools, while neuropathology relies on protocols that may alter tissue chemistry and structure. In contrast, recent ex vivo studies in mice demonstrated that X-ray phase-contrast tomography enables study of the 3D distribution of both vasculature and neuronal networks, without sample sectioning or use of staining. Here we present our findings on ex vivo SOD1G93A ALS mice spinal cord at a micrometric scale. An unprecedented direct quantification of neuro-vascular alterations at different stages of the disease is shown.


Assuntos
Esclerose Lateral Amiotrófica/diagnóstico por imagem , Medula Espinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Modelos Animais de Doenças , Imageamento Tridimensional , Camundongos , Camundongos Transgênicos , Sensibilidade e Especificidade , Razão Sinal-Ruído
9.
RSC Adv ; 10(6): 3366-3370, 2020 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-35497736

RESUMO

An efficient nano-sized delivery system is presented here allowing the immobilized, picolinium-tethered organic ligand to be released by X-ray irradiation. A marked difference was observed in the fragmentation efficiency by using conventional Cs-137 vs. pulsed sources.

10.
Phys Med ; 66: 45-54, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31557625

RESUMO

The local dose deposition obtained in X-ray radiotherapy can be increased by the presence of metal-based compounds in the irradiated tissues. This finding is strongly enhanced if the radiation energy is chosen in the kiloelectronvolt energy range, due to the proximity to the absorption edge. In this study, we present a MC application developed with the toolkit Geant4 to investigate the dosimetric distribution of a uniform monochromatic X-ray beam, and benchmark it against experimental measurements. Two validation studies were performed, using a commercial PTW RW3 water-equivalent slab phantom for radiotherapy, and a custom-made PMMA phantom conceived to assess the influence of high atomic number compounds on the dose profile, such as iodine and gadolinium at different concentrations. An agreement within 9% among simulations and experimental data was found for the monochromatic energies considered, which were in the range of 30-140 keV; the agreement was better than 5% for depths <60 mm. A dose enhancement was observed in the calculations, corresponding to the regions containing the contrast agents. Dose enhancement factors (DEFs) were calculated, and the highest values were found for energies higher than the corresponding K-edges of iodine and gadolinium. The in-silico results are in line with the empirical findings, which suggest that Geant4 can be satisfactorily used as a tool for the calculation of the percentage depth dose (PDD) at the energies considered in this study in the presence of contrast agents.


Assuntos
Metais , Método de Monte Carlo , Terapia por Raios X , Benchmarking , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Incerteza , Água
11.
J Clin Med ; 8(8)2019 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-31357677

RESUMO

Modern ventilatory strategies are based on the assumption that lung terminal airspaces act as isotropic balloons that progressively accommodate gas. Phase contrast synchrotron radiation computed tomography (PCSRCT) has recently challenged this concept, showing that in healthy lungs, deflation mechanisms are based on the sequential de-recruitment of airspaces. Using PCSRCT scans in an animal model of acute respiratory distress syndrome (ARDS), this study examined whether the numerosity (ASnum) and dimension (ASdim) of lung airspaces change during a deflation maneuver at decreasing levels of positive end-expiratory pressure (PEEP) at 12, 9, 6, 3, and 0 cmH2O. Deflation was associated with significant reduction of ASdim both in the whole lung section (passing from from 13.1 ± 2.0 at PEEP 12 to 7.6 ± 4.2 voxels at PEEP 0) and in single concentric regions of interest (ROIs). However, the regression between applied PEEP and ASnum was significant in the whole slice (ranging from 188 ± 52 at PEEP 12 to 146.4 ± 96.7 at PEEP 0) but not in the single ROIs. This mechanism of deflation in which reduction of ASdim is predominant, differs from the one observed in healthy conditions, suggesting that the peculiar alveolar micromechanics of ARDS might play a role in the deflation process.

12.
Front Physiol ; 10: 719, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31231245

RESUMO

INTRODUCTION: The mechanisms of lung inflation and deflation are only partially known. Ventilatory strategies to support lung function rely upon the idea that lung alveoli are isotropic balloons that progressively inflate or deflate and that lung pressure/volume curves derive only by the interplay of critical opening pressures, critical closing pressures, lung history, and position of alveoli inside the lung. This notion has been recently challenged by subpleural microscopy, magnetic resonance, and computed tomography (CT). Phase-contrast synchrotron radiation CT (PC-SRCT) can yield in vivo images at resolutions higher than conventional CT. OBJECTIVES: We aimed to assess the numerosity (ASden) and the extension of the surface of airspaces (ASext) in healthy conditions at different volumes, during stepwise lung deflation, in concentric regions of the lung. METHODS: The study was conducted in seven anesthetized New Zealand rabbits. They underwent PC-SRCT scans (resolution of 47.7 µm) of the lung at five decreasing positive end expiratory pressure (PEEP) levels of 12, 9, 6, 3, and 0 cmH2O during end-expiratory holds. Three concentric regions of interest (ROIs) of the lung were studied: subpleural, mantellar, and core. The images were enhanced by phase contrast algorithms. ASden and ASext were computed by using the Image Processing Toolbox for MatLab. Statistical tests were used to assess any significant difference determined by PEEP or ROI on ASden and ASext. RESULTS: When reducing PEEP, in each ROI the ASden significantly decreased. Conversely, ASext variation was not significant except for the core ROI. In the latter, the angular coefficient of the regression line was significantly low. CONCLUSION: The main mechanism behind the decrease in lung volume at PEEP reduction is derecruitment. In our study involving lung regions laying on isogravitational planes and thus equally influenced by gravitational forces, airspace numerosity and extension of surface depend on the local mechanical properties of the lung.

13.
Int J Radiat Oncol Biol Phys ; 101(4): 965-984, 2018 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-29976510

RESUMO

PURPOSE: Experimental neuroimaging provides a wide range of methods for the visualization of brain anatomic morphology down to subcellular detail. Still, each technique-specific detection mechanism presents compromises among the achievable field-of-view size, spatial resolution, and nervous tissue sensitivity, leading to partial sample coverage, unresolved morphologic structures, or sparse labeling of neuronal populations and often also to obligatory sample dissection or other sample invasive manipulations. X-ray phase-contrast imaging computed tomography (PCI-CT) is an experimental imaging method that simultaneously provides micrometric spatial resolution, high soft-tissue sensitivity, and ex vivo full organ rodent brain coverage without any need for sample dissection, staining or labeling, or contrast agent injection. In the present study, we explored the benefits and limitations of PCI-CT use for in vitro imaging of normal and cancerous brain neuromorphology after in vivo treatment with synchrotron-generated x-ray microbeam radiation therapy (MRT), a spatially fractionated experimental high-dose radiosurgery. The goals were visualization of the MRT effects on nervous tissue and a qualitative comparison of the results to the histologic and high-field magnetic resonance imaging findings. METHODS AND MATERIALS: MRT was administered in vivo to the brain of both healthy and cancer-bearing rats. At 45 days after treatment, the brain was dissected out and imaged ex vivo using propagation-based PCI-CT. RESULTS: PCI-CT visualizes the brain anatomy and microvasculature in 3 dimensions and distinguishes cancerous tissue morphology, necrosis, and intratumor accumulation of iron and calcium deposits. Moreover, PCI-CT detects the effects of MRT throughout the treatment target areas (eg, the formation of micrometer-thick radiation-induced tissue ablation). The observed neurostructures were confirmed by histologic and immunohistochemistry examination and related to the micro-magnetic resonance imaging data. CONCLUSIONS: PCI-CT enabled a unique 3D neuroimaging approach for ex vivo studies on small animal models in that it concurrently delivers high-resolution insight of local brain tissue morphology in both normal and cancerous micro-milieu, localizes radiosurgical damage, and highlights the deep microvasculature. This method could assist experimental small animal neurology studies in the postmortem evaluation of neuropathology or treatment effects.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Encéfalo/diagnóstico por imagem , Encéfalo/efeitos da radiação , Glioblastoma/diagnóstico por imagem , Glioblastoma/radioterapia , Neurorradiografia/métodos , Microtomografia por Raio-X/métodos , Animais , Encéfalo/irrigação sanguínea , Encéfalo/patologia , Neoplasias Encefálicas/patologia , Glioblastoma/patologia , Imageamento por Ressonância Magnética , Masculino , Microvasos/diagnóstico por imagem , Ratos , Ratos Endogâmicos F344
14.
Phys Med Biol ; 63(17): 175020, 2018 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-29999497

RESUMO

Breast physical phantoms are a basic tool for the assessment and verification of performance standards in daily clinical practice of x-ray breast imaging modalities. They are also invaluable in testing and evaluation of new x-ray breast modalities to be potentially established, e.g. breast computed tomography, dual-energy breast CT and phase-contrast mammography and tomography. Nowadays, there is a lack or there are only a limited number of breast physical phantoms available for this purpose. The aim of this study is to explore a range of 3D printing materials such as resins, PLA, ABS, Nylon etc, to determine their attenuation and refractive properties, and to finally compare them to the properties of the breast tissues: adipose, glandular and skin. To achieve this goal, step-wedge phantoms were computationally modeled and then manufactured using stereolithographic and fused-deposition modeling technologies. X-ray images of the phantoms were acquired, using monochromatic beam at ID17, ESRF, Grenoble for three energies-30 keV, 45 keV and 60 keV. Experimental data were further processed to obtain the linear attenuation coefficients of these materials. Comparison with theoretical data for the linear attenuation coefficients and the refractive indexes for breast tissues was performed. From the studied materials, most of the resins, Nylon, Hybrid, PET-G show absorption properties close to the glandular tissue, while ABS shows absorption characteristics close to these of the adipose tissue. For phase-contrast imaging, it turns out that the ABS combined with resin-based materials to represent the adipose and glandular tissues, respectively may be a good combination for manufacturing of a phantom suitable for these studies. These results can be used for the design and the construction of a new physical anthropomorphic phantom of the breast with improved anatomical and radiological characteristics dedicated for advanced mammography imaging techniques implemented at higher photon energies.


Assuntos
Mama/diagnóstico por imagem , Mamografia/métodos , Imagens de Fantasmas , Impressão Tridimensional/instrumentação , Tomografia Computadorizada por Raios X/métodos , Tecido Adiposo/diagnóstico por imagem , Simulação por Computador , Feminino , Humanos , Pele/diagnóstico por imagem
15.
AJR Am J Roentgenol ; 210(6): 1317-1322, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29629804

RESUMO

OBJECTIVE: The aim of this study was to quantitatively assess hyaline cartilage and subchondral bone conditions in a fully preserved cadaveric human knee joint using high-resolution x-ray propagation-based phase-contrast imaging (PBI) CT and to compare the performance of the new technique with conventional CT and MRI. MATERIALS AND METHODS: A cadaveric human knee was examined using an x-ray beam of 60 keV, a detector with a 90-mm2 FOV, and a pixel size of 46 × 46 µm2. PBI CT images were reconstructed with both the filtered back projection algorithm and the equally sloped tomography method. Conventional 3-T MRI and CT were also performed. Measurements of cartilage thickness, cartilage lesions, International Cartilage Repair Society scoring, and detection of subchondral bone changes were evaluated. Visual inspection of the specimen akin to arthroscopy was conducted and served as a standard of reference for lesion detection. RESULTS: Loss of cartilage height was visible on PBI CT and MRI. Quantification of cartilage thickness showed a strong correlation between the two modalities. Cartilage lesions appeared darker than the adjacent cartilage on PBI CT. PBI CT showed similar agreement to MRI for depicting cartilage substance defects or lesions compared with the visual inspection. The assessment of subchondral bone cysts showed moderate to strong agreement between PBI CT and CT. CONCLUSION: In contrast to the standard clinical methods of MRI and CT, PBI CT is able to simultaneously depict cartilage and bony changes at high resolution. Though still an experimental technique, PBI CT is a promising high-resolution imaging method to evaluate comprehensive changes of osteoarthritic disease in a clinical setting.


Assuntos
Doenças das Cartilagens/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Algoritmos , Cadáver , Doenças das Cartilagens/patologia , Cartilagem Articular/patologia , Humanos , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos
16.
Sci Rep ; 8(1): 184, 2018 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-29317649

RESUMO

Synchrotron-generated microplanar beams (microbeams) provide the most stereo-selective irradiation modality known today. This novel irradiation modality has been shown to control seizures originating from eloquent cortex causing no neurological deficit in experimental animals. To test the hypothesis that application of microbeams in the hippocampus, the most common source of refractory seizures, is safe and does not induce severe side effects, we used microbeams to induce transections to the hippocampus of healthy rats. An array of parallel microbeams carrying an incident dose of 600 Gy was delivered to the rat hippocampus. Immunohistochemistry of phosphorylated γ-H2AX showed cell death along the microbeam irradiation paths in rats 48 hours after irradiation. No evident behavioral or neurological deficits were observed during the 3-month period of observation. MR imaging showed no signs of radio-induced edema or radionecrosis 3 months after irradiation. Histological analysis showed a very well preserved hippocampal cytoarchitecture and confirmed the presence of clear-cut microscopic transections across the hippocampus. These data support the use of synchrotron-generated microbeams as a novel tool to slice the hippocampus of living rats in a minimally invasive way, providing (i) a novel experimental model to study hippocampal function and (ii) a new treatment tool for patients affected by refractory epilepsy induced by mesial temporal sclerosis.


Assuntos
Hipocampo/efeitos da radiação , Radiocirurgia/efeitos adversos , Animais , Hipocampo/metabolismo , Hipocampo/fisiologia , Histonas/genética , Histonas/metabolismo , Masculino , Fosfoproteínas/genética , Fosfoproteínas/metabolismo , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Ratos , Ratos Wistar , Síncrotrons
17.
Sci Rep ; 7(1): 14290, 2017 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-29085040

RESUMO

Microbeam radiation therapy is a novel preclinical technique, which uses synchrotron-generated X-rays for the treatment of brain tumours and drug-resistant epilepsies. In order to safely translate this approach to humans, a more in-depth knowledge of the long-term radiobiology of microbeams in healthy tissues is required. We report here the result of the characterization of the rat sensorimotor cortex tolerance to microradiosurgical parallel transections. Healthy adult male Wistar rats underwent irradiation with arrays of parallel microbeams. Beam thickness, spacing and incident dose were 100 or 600 µm, 400 or 1200 µm and 360 or 150 Gy, respectively. Motor performance was carried over a 3-month period. Three months after irradiation rats were sacrificed to evaluate the effects of irradiation on brain tissues by histology and immunohistochemistry. Microbeam irradiation of sensorimotor cortex did not affect weight gain and motor performance. No gross signs of paralysis or paresis were also observed. The cortical architecture was not altered, despite the presence of cell death along the irradiation path. Reactive gliosis was evident in the microbeam path of rats irradiated with 150 Gy, whereas no increase was observed in rats irradiated with 360 Gy.


Assuntos
Neoplasias Encefálicas/radioterapia , Epilepsia/radioterapia , Córtex Sensório-Motor/efeitos da radiação , Raios X/efeitos adversos , Animais , Gliose/patologia , Masculino , Paralisia/patologia , Paresia/patologia , Desempenho Psicomotor/efeitos da radiação , Doses de Radiação , Ratos , Ratos Wistar , Córtex Sensório-Motor/metabolismo , Síncrotrons , Aumento de Peso/efeitos da radiação
18.
Phys Med Biol ; 61(24): 8750-8761, 2016 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-27893445

RESUMO

Since the breast is one of the most radiosensitive organs, mammography is arguably the area where lowering radiation dose is of the uttermost importance. Phase-based x-ray imaging methods can provide opportunities in this sense, since they do not require x-rays to be stopped in tissue for image contrast to be generated. Therefore, x-ray energy can be considerably increased compared to those usually exploited by conventional mammography. In this article we show how a novel, optimized approach can lead to considerable dose reductions. This was achieved by matching the edge-illumination phase method, which reaches very high angular sensitivity also at high x-ray energies, to an appropriate image processing algorithm and to a virtually noise-free detection technology capable of reaching almost 100% efficiency at the same energies. Importantly, while proof-of-concept was obtained at a synchrotron, the method has potential for a translation to conventional sources.


Assuntos
Mamografia/métodos , Doses de Radiação , Algoritmos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Mamografia/instrumentação , Pessoa de Meia-Idade , Razão Sinal-Ruído , Síncrotrons , Raios X
19.
Phys Med ; 32(12): 1779-1784, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27743707

RESUMO

High resolution Synchrotron-based X-ray Phase Contrast Tomography (XPCT) allows the simultaneous detection of three dimensional neuronal and vascular networks without using contrast agents or invasive casting preparation. We show and discuss the different features observed in reconstructed XPCT volumes of the ex vivo mouse spinal cord in the lumbo-sacral region, including motor neurons and blood vessels. We report the application of an intensity-based segmentation method to detect and quantitatively characterize the modification in the vascular networks in terms of reduction in experimental visibility. In particular, we apply our approach to the case of the experimental autoimmune encephalomyelitis (EAE), i.e. human multiple sclerosis animal model.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Medula Espinal/irrigação sanguínea , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Animais , Encefalomielite Autoimune Experimental/diagnóstico por imagem , Encefalomielite Autoimune Experimental/fisiopatologia , Feminino , Imageamento Tridimensional , Camundongos
20.
PLoS One ; 11(6): e0158306, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27362638

RESUMO

OBJECTIVES: Neoadjuvant chemotherapy is the state-of-the-art treatment in advanced breast cancer. A correct visualization of the post-therapeutic tumor size is of high prognostic relevance. X-ray phase-contrast computed tomography (PC-CT) has been shown to provide improved soft-tissue contrast at a resolution formerly restricted to histopathology, at low doses. This study aimed at assessing ex-vivo the potential use of PC-CT for visualizing the effects of neoadjuvant chemotherapy on breast carcinoma. MATERIALS AND METHODS: The analysis was performed on two ex-vivo formalin-fixed mastectomy samples containing an invasive carcinoma removed from two patients treated with neoadjuvant chemotherapy. Images were matched with corresponding histological slices. The visibility of typical post-therapeutic tissue changes was assessed and compared to results obtained with conventional clinical imaging modalities. RESULTS: PC-CT depicted the different tissue types with an excellent correlation to histopathology. Post-therapeutic tissue changes were correctly visualized and the residual tumor mass could be detected. PC-CT outperformed clinical imaging modalities in the detection of chemotherapy-induced tissue alterations including post-therapeutic tumor size. CONCLUSIONS: PC-CT might become a unique diagnostic tool in the prediction of tumor response to neoadjuvant chemotherapy. PC-CT might be used to assist during histopathological diagnosis, offering a high-resolution and high-contrast virtual histological tool for the accurate delineation of tumor boundaries.


Assuntos
Antineoplásicos/farmacologia , Neoplasias da Mama/tratamento farmacológico , Mama/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Antineoplásicos/uso terapêutico , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Terapia Neoadjuvante , Fixação de Tecidos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA