Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 37(2): 437-447, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36201093

RESUMO

We examined whether a semi-automated carbon monoxide (CO) rebreathing method accurately detect changes in blood volume (BV) and total hemoglobin mass (tHb). Furthermore, we investigated whether a supine position with legs raised reduced systemic CO dilution time, potentially allowing a shorter rebreathing period. Nineteen young healthy males participated. BV and tHb was quantified by a 10-min CO-rebreathing period in a supine position with legs raised before and immediately after a 900 ml phlebotomy and before and after a 900 ml autologous blood reinfusion on the same day in 16 subjects. During the first CO-rebreathing, arterial and venous blood samples were drawn every 2 min during the procedure to determine systemic CO equilibrium in all subjects. Phlebotomy decreased (P < 0.001) tHb and BV by 166 ± 24 g and 931 ± 247 ml, respectively, while reinfusion increased (P < 0.001) tHb and BV by 143 ± 21 g and 862 ± 250 ml compared to before reinfusion. After reinfusion BV did not differ from baseline levels while tHb was decreased (P < 0.001) by 36 ± 21 g. Complete CO mixing was achieved within 6 min in venous and arterial blood, respectively, when compared to the 10-min sample. On an individual level, the relative accuracy after donation for tHb and BV was 102-169% and 55-165%, respectively. The applied CO-rebreathing procedure precisely detect acute BV changes with a clinically insignificant margin of error. The 10-min CO-procedure may be reduced to 6 min with no clinical effects on BV and tHb calculation. Notwithstanding, individual differences may be of concern and should be investigated further.


Assuntos
Monóxido de Carbono , Hemoglobinas , Masculino , Humanos , Volume Sanguíneo , Veias , Cinética
2.
Am J Physiol Regul Integr Comp Physiol ; 321(2): R152-R161, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34160288

RESUMO

Current markers of iron deficiency (ID), such as ferritin and hemoglobin, have shortcomings, and hepcidin and erythroferrone (ERFE) could be of clinical relevance in relation to early assessment of ID. Here, we evaluate whether exposure to altitude-induced hypoxia (2,320 m) alone, or in combination with recombinant human erythropoietin (rHuEPO) treatment, affects hepcidin and ERFE levels before alterations in routine ID biomarkers and stress erythropoiesis manifest. Two interventions were completed, each comprising a 4-wk baseline, a 4-wk intervention at either sea level or altitude, and a 4-wk follow-up. Participants (n = 39) were randomly assigned to 20 IU·kg body wt-1 rHuEPO or placebo injections every second day for 3 wk during the two intervention periods. Venous blood was collected weekly. Altitude increased ERFE (P ≤ 0.001) with no changes in hepcidin or routine iron biomarkers, making ERFE of clinical relevance as an early marker of moderate hypoxia. rHuEPO treatment at sea level induced a similar pattern of changes in ERFE (P < 0.05) and hepcidin levels (P < 0.05), demonstrating the impact of accelerated erythropoiesis and not of other hypoxia-induced mechanisms. Compared with altitude alone, concurrent rHuEPO treatment and altitude exposure induced additive changes in hepcidin (P < 0.05) and ERFE (P ≤ 0.001) parallel with increases in hematocrit (P < 0.001), demonstrating a relevant range of both hepcidin and ERFE. A poor but significant correlation between hepcidin and ERFE was found (R2 = 0.13, P < 0.001). The findings demonstrate that hepcidin and ERFE are more rapid biomarkers of changes in iron demands than routine iron markers. Finally, ERFE and hepcidin may be sensitive markers in an antidoping context.


Assuntos
Doença da Altitude/sangue , Altitude , Epoetina alfa/administração & dosagem , Eritropoese/efeitos dos fármacos , Hematínicos/administração & dosagem , Hepcidinas/sangue , Ferro/sangue , Hormônios Peptídicos/sangue , Doença da Altitude/diagnóstico , Biomarcadores/sangue , Dinamarca , Método Duplo-Cego , Feminino , Homeostase , Humanos , Injeções Intravenosas , Masculino , Proteínas Recombinantes/administração & dosagem , Espanha , Fatores de Tempo
3.
Drug Test Anal ; 13(7): 1331-1340, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33739618

RESUMO

We investigated whether immature reticulocyte fraction (IRF) and immature reticulocytes to red blood cells ratio (IR/RBC) are sensitive biomarkers for low-dose recombinant human erythropoietin (rhEpo) treatment at sea level (SL) and moderate altitude (AL) and whether multi (FACS) or single (Sysmex-XN) fluorescence flow cytometry is superior for IRF and IR/RBC determination. Thirty-nine participants completed two interventions, each containing a 4-week baseline, a 4-week SL or AL (2,230 m) exposure, and a 4-week follow-up. During exposure, rhEpo (20 IU kg-1 ) or placebo (PLA) was injected at SL (SLrhEpo , n = 25, SLPLA n = 9) and AL (ALrhEpo , n = 12, ALPLA n = 27) every second day for 3 weeks. Venous blood was collected weekly. Sysmex measurements revealed that IRF and IR/RBC were up to ~70% (P < 0.01) and ~190% (P < 0.001) higher in SLrhEpo than SLPLA during treatment and up to ~45% (P < 0.001) and ~55% (P < 0.01) lower post-treatment, respectively. Compared with ALPLA , IRF and IR/RBC were up to ~20% (P < 0.05) and ~45% (P < 0.001) lower post-treatment in SLrhEpo , respectively. In ALrhEpo , IRF and IR/RBC were up to ~40% (P < 0.05) and ~110% (P < 0.001) higher during treatment and up to ~25% (P < 0.05) and ~40% (P < 0.05) lower post-treatment, respectively, compared with ALPLA . Calculated thresholds provided ~90% sensitivity for both biomarkers at SL and 33% (IRF) and 66% (IR/RBC) at AL. Specificity was >99%. Single-fluorescence flow cytometry coefficient of variation was >twofold higher at baseline (P < 0.001) and provided larger or similar changes compared to multi-fluorescence, albeit with smaller precision. In conclusion, IRF and IR/RBC were sensitive and specific biomarkers for low-dose rhEpo misuse at SL and AL.


Assuntos
Altitude , Epoetina alfa/farmacologia , Hematínicos/farmacologia , Reticulócitos/efeitos dos fármacos , Adulto , Biomarcadores/metabolismo , Método Duplo-Cego , Epoetina alfa/administração & dosagem , Contagem de Eritrócitos , Eritrócitos/citologia , Feminino , Citometria de Fluxo , Seguimentos , Hematínicos/administração & dosagem , Humanos , Masculino , Contagem de Reticulócitos , Reticulócitos/citologia , Adulto Jovem
4.
Clin Physiol Funct Imaging ; 38(2): 240-245, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28135764

RESUMO

INTRODUCTION: The carbon monoxide (CO) rebreathing method used for the determination of haemoglobin mass (Hbmass ) is associated with blood sample analysis (in this study: Radiometer ABL800). As an alternative hereto the aim of the present study was to evaluate the use of a portable and non-invasive CO pulse oximeter (Rad-57). METHOD: With simultaneous determination of CO in the circulation by ABL800 (%HbCO) and Rad-57 (SpCO), Hbmass and blood volume (BV) were determined in duplicates in 24 volunteers. Percentage of typical errors (%TE) within methods and linear correlations between the two procedures were computed. RESULTS: Hbmass (Rad-57 = 798 ± 230 g; ABL800 = 781 ± 192 g) and BV (Rad-57 = 5700 ± 1373 ml; ABL800 = 5581 ± 1096 ml) were similar between methods. However, the %TE for Hbmass was higher (P<0·001) for Rad-57 (5·84 ± 5·29%) than for ABL800 (1·35 ± 1·13%). Similarly, the %TE for BV was higher (P<0·001) for Rad-57 (6·06 ± 5·76%) than for ABL800 (1·48 ± 1·25%). Lower (P<0·05) correlation coefficients between the methods were found when Hbmass  > 905 g and BV > 6193 ml. CONCLUSION: Assessment of SpCO by Rad-57 resulted in considerably less precise determinations of Hbmass and BV, especially for high values. Thus, non-invasive assessment of Hbmass and BV cannot be recommended for scientific purposes, but may nonetheless be useful in clinical settings.


Assuntos
Determinação do Volume Sanguíneo/instrumentação , Volume Sanguíneo , Monóxido de Carbono/sangue , Hemoglobinas/metabolismo , Oximetria/instrumentação , Administração por Inalação , Adulto , Biomarcadores/sangue , Monóxido de Carbono/administração & dosagem , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Modelos Lineares , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA