RESUMO
OBJECTIVE: To evaluate the diagnostic performance of abbreviated breast MRI compared with mammography in women with a family history of breast cancer included in the Croatian National Breast Screening Program. METHODS: 178 women with a family history of breast cancer aged 50 to 69 underwent abbreviated breast MRI and mammography. Radiological findings for each method were categorized according to the BI-RADS classification. The gold standard for assessing the diagnostic accuracy of breast MRI and mammography, in terms of suspicious BI-RADS 4 and BI-RADS 5 findings, was the histopathological diagnosis. Performance measures, including cancer detection rates, specificity, sensitivity, and positive and negative predictive values, were calculated for both imaging methods. RESULTS: Twelve new cases of breast cancer were detected, with seven (58.3%) identified only by abbreviated breast MRI, four (33.3%) detected by both mammography and breast MRI, and one (8.3%) diagnosed only by mammography. Diagnostic accuracy parameters for abbreviated breast MRI were 91.67% sensitivity, 94.58% specificity, 55.0% positive predictive value (PPV), and 99.37% negative predictive value (NPV), while for mammography, the corresponding values were 41.67%, 96.39%, 45.46%, and 95.81%, respectively. CONCLUSIONS: Abbreviated breast MRI is a useful supplement to screening mammography in women with a family history of breast cancer. Considering the results of the conducted research, it is recommended to assess whether women with a family history of breast cancer have an increased risk and subsequently provide annual abbreviated breast MRI in addition to mammography for early detection of breast cancer.
RESUMO
BACKGROUND: Advanced imaging techniques play a pivotal role in oncology. A large variety of computed tomography (CT) scanners, scan protocols, and acquisition techniques have led to a wide range in image quality and radiation exposure. This study aims at implementing verifiable oncological imaging by quality assurance and optimization (i-Violin) through harmonizing image quality and radiation dose across Europe. METHODS: The 2year multicenter implementation study outlined here will focus on CT imaging of lung, stomach, and colorectal cancer and include imaging for four radiological indications: diagnosis, radiation therapy planning, staging, and follow-up. Therefore, 480 anonymized CT data sets of patients will be collected by the associated university hospitals and uploaded to a repository. Radiologists will determine key abdominopelvic structures for image quality assessment by consensus and subsequently adapt a previously developed lung CT tool for the objective evaluation of image quality. The quality metrics will be evaluated for their correlation with perceived image quality and the standardized optimization strategy will be disseminated across Europe. RESULTS: The results of the outlined study will be used to obtain European reference data, to build teaching programs for the developed tools, and to create a culture of optimization in oncological CT imaging. CONCLUSION: The study protocol and rationale for iViolin, a European approach for standardization and harmonization of image quality and optimization of CT procedures in oncological imaging, is presented. Future results will be disseminated across all EU member states, and iViolin is thus expected to have a sustained impact on CT imaging for cancer patients across Europe.
Assuntos
Neoplasias Induzidas por Radiação , Doses de Radiação , Exposição à Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Exposição à Radiação/efeitos adversos , Criança , Medição de Risco , Fatores de Risco , Proteção Radiológica/métodosRESUMO
OBJECTIVES: To develop an intuitive and generally applicable system for the reporting, assessment, and documentation of ADC to complement standard BI-RADS criteria. METHODS: This was a multicentric, retrospective analysis of 11 independently conducted institutional review board-approved studies from seven institutions performed between 2007 and 2019. Breast Apparent Diffusion coefficient (ADC-B) categories comprised ADC-B0 (ADC non-diagnostic), ADC-B1 (no enhancing lesion), and ADC-B2-5. The latter was defined by plotting ADC versus cumulative malignancy rates. Statistics comprised ANOVA with post hoc testing and ROC analysis. p values ≤ 0.05 were considered statistically significant. RESULTS: A total of 1625 patients (age: 55.9 years (± 13.8)) with 1736 pathologically verified breast lesions were included. The mean ADC (× 10-3 mm2/s) differed significantly between benign (1.45, SD .40) and malignant lesions (.95, SD .39), and between invasive (.92, SD .22) and in situ carcinomas (1.18, SD .30) (p < .001). The following ADC-B categories were identified: ADC-B0-ADC cannot be assessed; ADC-B1-no contrast-enhancing lesion; ADC-B2-ADC ≥ 1.9 (cumulative malignancy rate < 0.1%); ADC-B3-ADC 1.5 to < 1.9 (0.1-1.7%); ADC-B4-ADC 1.0 to < 1.5 (10-24.5%); and ADC-B5-ADC < 1.0 (> 24.5%). At the latter threshold, a positive predictive value of 95.8% (95% CI 0.94-0.97) for invasive versus non-invasive breast carcinomas was reached. CONCLUSIONS: The breast apparent diffusion coefficient system (ADC-B) provides a simple and widely applicable categorization scheme for assessment, documentation, and reporting of apparent diffusion coefficient values in contrast-enhancing breast lesions on MRI. CLINICAL RELEVANCE STATEMENT: The ADC-B system, based on diverse MRI examinations, is clinically relevant for stratifying breast cancer risk via apparent diffusion coefficient measurements, and complements BI-RADS for improved clinical decision-making and patient outcomes. KEY POINTS: ⢠The breast apparent diffusion coefficient category system (ADC-B) is a simple tool for the assessment, documentation, and reporting of ADC values in contrast-enhancing breast lesions on MRI. ⢠The categories comprise ADC-B0 for non-diagnostic examinations, ADC-B1 for examinations without an enhancing lesion, and ADC-B2-5 for enhancing lesions with an increasing malignancy rate. ⢠The breast apparent diffusion coefficient category system may be used to complement BI-RADS in clinical decision-making.
Assuntos
Neoplasias da Mama , Meios de Contraste , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Diagnóstico Diferencial , Mama/diagnóstico por imagem , Mama/patologia , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Neoplasias da Mama/patologia , Sensibilidade e EspecificidadeRESUMO
AIM: To assess the uptake of the Croatian National Breast Cancer Screening Program from 2006 to 2016. METHODS: The Croatian National Breast Cancer Screening Program, a biennial program targeting women aged 50-69, started in October 2006. From 2006 to 2016, four cycles were completed. One cycle lasted two years, with the exception of the first cycle, which lasted three years. To determine the number of detected cancers in each cycle, the screening program data were merged with the data of the Croatian National Cancer Registry. Our results were compared with the reference values from the European guidelines for quality assurance in breast cancer screening and diagnosis. RESULTS: Around 150 000 mammography exams were performed every year. The response rates for cycle 1, cycle 2, cycle 3, and cycle 4 were 63%, 57%, 60%, and 59%, respectively. Further assessment rate was 6.5%. Breast cancer was identified in 5583 women, with 4.8 cancers detected per 1000 mammography exams. CONCLUSION: The National Breast Cancer Screening Program in Croatia reached a substantial proportion of the target group. Yet, additional efforts are needed to reach at least 70% of the target population.
Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Croácia/epidemiologia , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Mamografia , Programas de RastreamentoRESUMO
PURPOSE: To investigate if second-look US using shear-wave elastography (SWE) can help to differentiate between benign and malignant changes in the postoperative breast after surgical treatment of breast carcinoma. MATERIALS AND METHODS: SWE and related sonographic features were reviewed in 90 female patients with a history of surgical treatment of breast carcinoma and a suspicious lesion detected on a follow-up MRI scan. A single experienced radiologist performed all second-look US exams with SWE measurements placing a circular region of interest measuring 2âmm in diameter over the stiffest part of the lesion. Tissue samples for histopathological analysis were obtained during the same US examination via core-needle biopsy. RESULTS: Out of 90 lesions, 39 were proven malignant on histopathological analysis. 50â% of malignant lesions had Elmax values ranging from 128 to 199 kPa, and 50â% of benign lesions had Elmax values ranging from 65 to 169 kPa. The cut-off value of 171.2 kPa for Elmax shows a sensitivity of 59â% and specificity of 78.4â% for carcinoma recurrence, area under the curve 0.706 (CI95â% 0.6-0.81), Pâ=â0.001. In univariate logistic models, restricted diffusion and stiffness on SWE, Elmax >â171.2 kPa, were shown as significant recurrence predictors. In the multivariate model, restricted diffusion remains significant independent recurrence predictor. With a recurrence prevalence of 43â%, the test sensitivity is 95â% (CI95â% 81-99â%) and the specificity is 75â% (CI95â% 60-85â%). CONCLUSION: Stiffer lesions should be considered suspicious on second-look US in the postoperative breast and SWE can be a helpful tool in identifying malignant lesions, especially if this is related to restricted diffusion on MRI exam. Lesion stiffness, however, should not be considered as an independent predictor of lesion malignancy in the postoperative breast, because of benign changes that can appear stiff on SWE, as well as carcinoma recurrences that may appear soft.
Assuntos
Neoplasias da Mama , Carcinoma , Técnicas de Imagem por Elasticidade , Mama/diagnóstico por imagem , Mama/patologia , Mama/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma/patologia , Diagnóstico Diferencial , Feminino , Humanos , Imageamento por Ressonância Magnética , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia MamáriaRESUMO
BACKGROUND Giant cell tumor is a rare tumor of mesenchymal origin. According to World Health Organization classification, it is considered a benign tumor with locally aggressive characteristics and the capacity to metastasize. The tumor typically occurs in the epiphyseal regions, most often of long bones after the completion of bone growth. The disease is characterized by severe pain and swelling of the affected area. Tumor growth is expansive but relatively slow. The tumor rarely metastasizes, but when it does, the lungs are primarily affected. CASE REPORT A 28-year-old man, otherwise healthy, presented with pain in the right wrist joint, limited range of motion, and spindle-shaped thickening/swelling in the same area, which he had noticed several months earlier. After a comprehensive diagnostic evaluation (wrist X-ray, computed tomography, magnetic resonance imaging, ultrasound-guided biopsy, and histopathological analysis), he was diagnosed with giant cell tumor of the right ulna. The tumor was surgically removed with good recovery, and the patient continued to be seen thereafter in regular followup. CONCLUSIONS The wide range of benign and malignant differential diagnostic entities requires a detailed diagnostic approach and comprehensive assessment, using different radiological modalities, as was done in this case. The final diagnosis was confirmed by histopathological analysis of core biopsy material.
Assuntos
Neoplasias Ósseas , Tumores de Células Gigantes , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Ulna/diagnóstico por imagem , PunhoRESUMO
Spontaneous pneumomediastinum (SPM), pneumothorax (PNX) and subcutaneous emphysema are rare complications of COVID-19 pneumonia. In this paper we describe 3 cases of COVID-19 pneumonia complicated by SPM with or without PNX. Patient 1 was a 56-year-old woman whose medical history was significant for chronic leukemia. She presented with typical clinical signs of COVID-19 pneumonia and after 2 weeks of hospitalization she developed SPM and subcutaneous emphysema. The management of pneumomediastinum (PNM) was conservative and follow-up computed tomography showed resolution of PNM. Patient 2 was a 67-year-old man presenting with fever, cough and dyspnea. Computed tomography pulmonary angiography was performed after 2 weeks of hospitalization and showed bilateral peripheral consolidations together with massive PNM and right-sided PNX. Thoracic drainage catheter was inserted in his right chest. Despite all supportive care, the patient succumbed to illness. Patient 3 was a 74-year-old man who was admitted to our hospital with COVID-19 pneumonia and spontaneous right-sided PNX. A thoracic drainage catheter was inserted immediately and then removed after ten days which has led to progression of subcutaneous emphysema, PNX and newly diagnosed PNM. Patient was carefully monitored for the next 2 weeks. Follow-up chest x-ray showed regression of PNM and PNX. SPM, PNX and subcutaneous emphysema are rare complications of COVID-19 pneumonia. Increased alveolar pressure and diffuse alveolar injury in severe COVID-19 pneumonia may make the alveoli more prone to rupturing which leads to gas dissemination along the peribronchovascular sheath to the mediastinum. Most cases of SPM and PNX resolve with conservative management.
RESUMO
Shear wave elastography (SWE) is a type of ultrasound elastography with which the elastic properties of breast tissues can be quantitatively assessed. The purpose of this study was to determine the impact of different regions of interest (ROI) and lesion size on the performance of SWE in differentiating malignant breast lesions. The study included 150 female patients with histopathologically confirmed malignant breast lesions. Minimal (Emin), mean (Emean), maximal (Emax) elastic modulus and elasticity ratio (e-ratio) values were measured using a circular ROI size of 2, 4 and 6 mm diameters and the lesions were divided into large (diameter ≥ 15 mm) and small (diameter < 15 mm). Highest Emin, Emean and e-ratio values and lowest variability were observed when using the 2 mm ROI. Emax values did not differ between different ROI sizes. Larger lesions had significantly higher Emean and Emax values, but there was no difference in e-ratio values between lesions of different sizes. In conclusion, when measuring the Emin, Emean and e-ratio of malignant breast lesions using SWE the smallest possible ROI size should be used regardless of lesion size. ROI size has no impact on Emax values while lesion size has no impact on e-ratio values.
RESUMO
PURPOSE: It was demonstrated that about 6% of patients with a ruptured Achilles tendon experience the rupture of contralateral tendon in the future; the aim of this study was to estimate the risk for rupture of contralateral tendon in patients who underwent surgical reconstruction of ruptured Achilles tendon by using subjective questionnaires and shear-wave elastography. METHODS: Twenty-four patients who underwent surgical repair of the ruptured Achilles tendon and twelve age-matched healthy controls were examined with ultrasound SWE. Functional outcomes were assessed with American Orthopedic Foot and Ankle Society (AOFAS) scoring system and subjective rating system which we introduced and validated. RESULTS: The elasticity of injured tendon was markedly decreased (by 42%) compared to the contralateral tendon of the patient, as expected. Both AOFAS score and our novel subjective assessment scale positively correlate with ultrasound SWE values in ruptured Achilles tendons. The elasticity of contralateral Achilles tendons in patients was 23% lower than among healthy individuals. CONCLUSION: Irrespective of the lack of difference in the subjective feeling assessed by AOFAS, the contralateral tendon in the patients with reconstructed Achilles tendon has significantly lower stiffness than healthy individuals. Therefore, contralateral tendons in patients who suffered from rupture are more prone to future ruptures.
Assuntos
Tendão do Calcâneo , Técnicas de Imagem por Elasticidade , Traumatismos dos Tendões , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/cirurgia , Humanos , Ruptura/diagnóstico por imagem , Ruptura/cirurgia , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/epidemiologia , UltrassonografiaRESUMO
AIM: To determine the relationship between breast stiffness assessed with sonoelastography (elasticity) and breast tissue density assessed with mammography (MG) and ultrasound (US). METHODS: This cross-sectional study involved 100 women who underwent MG, gray-scale US, and shear-wave sonoelastography during 2013. Mammographic density was categorized into four groups and sonographic density into three groups according to Breast Imaging-Reporting and Data System criteria. The stiffness of breast parenchymal and adipose tissue in all breast quadrants was quantified by shear-wave sonoelastography. Mean elastographic estimates were compared with MG- and US-derived density estimates. RESULTS: Parenchymal and adipose tissue elasticity positively correlated with MG- and US-derived breast density (for parenchyma: for MG Kendall's tau b 0.522; Jonckheere-Terpstra test P<0.001 and for US Kendall's tau b 0.533; Jonckheere-Terpstra test P<0.001); the higher was the breast density on MG and US, the higher was the elastographic stiffness. CONCLUSION: Sonoelastographic breast stiffness strongly positively correlated with breast density. Thus, sonoelastography may have a potential for estimating the breast cancer risk, which allows a novel application of this technique in routine clinical practice.
Assuntos
Tecido Adiposo/fisiologia , Densidade da Mama/fisiologia , Mama/diagnóstico por imagem , Mama/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Tecido Parenquimatoso/fisiologia , Ultrassonografia Mamária/métodos , Adulto , Idoso , Estudos Transversais , Elasticidade/fisiologia , Feminino , Humanos , Pessoa de Meia-Idade , UltrassonografiaRESUMO
Breast sonoelastography is a relatively novel ultrasound (US) method that enables estimation of tissue stiffness to estimate the elasticity of normal breast tissue and seek to correlate it with well-known breast cancer risk factors. Two hundred women of different age were included in the study and completed a questionnaire about personal, familiar, and reproductive history. Glandular and fatty tissue elasticity in all breast quadrants was measured by shear wave elastography (SWE). Mean elastographic values of breast tissue were calculated and compared to personal history risk factors. Elasticity of normal glandular tissue (66.4 kilopascals (kPa)) was higher than fatty tissue (26.1 kPa) in all breast quadrants and in both breasts. Lower outer quadrant (LOQ) had the lowest elasticity values of both parenchyma and fat. Higher elasticity values of breast tissue were confirmed in the left breast than in the right breast. Glandular and fat tissue elasticity negatively correlated with body mass index (BMI). Women with mastodynia had higher glandular elastographic values compared to subjects without breast pain. Nuliparity was also associated with higher elasticity of glandular breast tissue. The results of this study are promising and could, over time, contribute to a better understanding of glandular breast tissue elasticity as a potential risk factor for breast cancer.
RESUMO
We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion localisation under imaging guidance. After explaining why a preoperative diagnosis with a percutaneous biopsy is preferred to surgical biopsy, we illustrate the criteria used by radiologists for choosing the most appropriate combination of device type for sampling and imaging technique for guidance. Then, we describe the commonly used devices, from fine-needle sampling to tissue biopsy with larger needles, namely core needle biopsy and vacuum-assisted biopsy, and how mammography, digital breast tomosynthesis, ultrasound, or magnetic resonance imaging work for targeting the lesion for sampling or localisation. The differences among the techniques available for localisation (carbon marking, metallic wire, radiotracer injection, radioactive seed, and magnetic seed localisation) are illustrated. Type and rate of possible complications are described and the issue of concomitant antiplatelet or anticoagulant therapy is also addressed. The importance of pathological-radiological correlation is highlighted: when evaluating the results of any needle sampling, the radiologist must check the concordance between the cytology/pathology report of the sample and the radiological appearance of the biopsied lesion. We recommend that special attention is paid to a proper and tactful approach when communicating to the woman the need for tissue sampling as well as the possibility of cancer diagnosis, repeat tissue sampling, and or even surgery when tissue sampling shows a lesion with uncertain malignant potential (also referred to as "high-risk" or B3 lesions). Finally, seven frequently asked questions are answered.
RESUMO
The aim of this study was to evaluate the quantitative sonoelastographic values recorded on shear-wave sonoelastography (SWE) of high-risk breast lesions and ductal carcinoma in situ (DCIS). We retrospectively analyzed histopathologic and SWE data (quantitative maximum, minimum and mean stiffness, lesion-to-fat ratio (E-ratio), lesion size) of 228 women referred to our Department for core needle breast biopsy during a four-year period. Among 230 lesions, histopathologic findings showed 34 high-risk breast lesions and 29 DCIS, which were compared with 167 ductal invasive carcinomas. High-risk lesions had lower values of all sonoelastographic features than ductal in situ and invasive carcinoma, however, only E-ratio showed a statistically significant difference in comparison to DCIS (3.7 vs. 6, p<0.001). All sonoelastographic features showed significant difference between in situ and invasive carcinoma. There was a significant correlation between lesion size and stiffness (r=0.36; p<0.001). Stiffness measured by SWE is an effective predictor of the histopathologic severity of sonographically detectable breast lesions. Elasticity values of high-risk lesions are significantly lower than those of malignant lesions. Furthermore, we showed that along with the sonographic appearance, which in most cases shows typical microcalcifications, DCIS had significantly different elasticity parameters than invasive carcinoma.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Neoplasias da Mama/patologia , Calcinose/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Estudos RetrospectivosRESUMO
BACKGROUND: A definitive diagnosis of malignant pleural effusion (MPE) is reached by cytological or histological assessment, but thorough analysis of the ultrasound features of the effusion as well as pleural thickening or nodularity can also be of significant diagnostic help. OBJECTIVE: To assess the relationship of specific ultrasound characterisctics and macroscopic features of confirmed malignant pleural effusion, thus increasing the diagnostic potential of thoracic ultrasound. METHODS: The findings of thoracic ultrasonography performed prior to initial thoracentesis in 104 patients with subsequently confirmed malignant pleural effusion were analyzed with regard to the macroscopic features of the pleural effusion. RESULTS: Distribution in terms of frequency of hemorrhagic/sanguinolent (n=64) in relation to nonhemorrhagic transparent/opaque (n=40) MPE, regardless of their ultrasound characteristics, did not yield a statistically significant correlation (p=0.159). Conversely, the frequency distribution of hemorrhagic pleural effusions (n=8) in relation to nonhemorrhagic effusions (n=1), in the group of septated MPE, showed a statistically significant difference (p<0.001). The least number of patients (0.96%) had a complex septated MPE combined with the macroscopic appearance of a serous/transparent nonhemorrhagic effusion, which suggests that this combination is a sporadic occurrence and may have a diagnostic significance for this patient group. CONCLUSION: The incidence of specific combinations of the ultrasound characteristics and macroscopic appearance of MPEs showed different frequency distributions, which may improve the diagnostic value of thoracic ultrasound in this patient population.
Assuntos
Derrame Pleural Maligno/diagnóstico por imagem , Derrame Pleural Maligno/patologia , Idoso , Biópsia por Agulha , Feminino , Hemorragia/patologia , Humanos , Biópsia Guiada por Imagem , Masculino , Estudos Retrospectivos , UltrassonografiaRESUMO
BACKGROUND: The capability of diffusion-weighted imaging (DWI) for morphological analysis of breast lesions is underexplored. PURPOSE: To evaluate the utility of DWI for assessment of morphological features of breast cancer by comparing DWI and dynamic contrast-enhanced (DCE) MRI findings to determine intermethod and interobserver agreement. STUDY TYPE: Retrospective. POPULATION: Seventy-eight women with pathohistologically proven breast cancer. FIELD STRENGTH/SEQUENCE: 1.5T. DWI and DCE images. ASSESSMENT: Diffusion-weighted and DCE images were placed in two separate case sets. Three radiologists, blinded to all other information, independently evaluated each case set on two separate occasions. Lesions were interpreted according to the fifth edition of the ACR BI-RADS lexicon. STATISTICAL ANALYSIS: Kappa (κ) statistics were calculated in order to assess intermethod and interobserver agreement. RESULTS: For values that attained statistical significance (P < 0.05), intermethod agreement ranged from fair (κ = 0.22) for nonmass internal patterns to significant (κ = 0.8) for lesion type. On DWI, interobserver agreement varied from fair (κ = 0.34) for mass shape to significant (κ = 0.75) for lesion type. On DCE MRI, interobserver agreement varied from fair (κ = 0.27) for irregular vs. spiculated mass margin to perfect (κ = 1) for circumscribed vs. noncircumscribed mass margin. DATA CONCLUSION: On the whole, there was moderate intermethod agreement. The values of interobserver agreement were mostly similar between DWI and DCE MRI. This suggests that DWI is applicable for morphological assessment of breast cancer, notwithstanding substantially inferior spatial resolution compared to DCE MRI. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2019;49:1381-1390.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
PURPOSE: The aim of this study was to assess diagnostic accuracies of ultrasonography (US) and magnetic resonance imaging (MRI) in lesions that manifest as mammographic BI-RADS 4 and 5 microcalcifications, in the setting of conjoined use of mammography, US, and MRI. METHODS: Patients with mammographic BI-RADS 4 or 5 microcalcifications, without additional findings, were included in this prospective study. All patients subsequently underwent breast US and MRI. Histopathologic diagnosis, obtained by US-guided core-needle biopsy or surgical excision, served as a reference standard. Diagnostic accuracies of US and MRI were calculated, and positive predictive value for different MRI BI-RADS imaging features were determined. RESULTS: The study group consisted of 113 women with 125 areas of suspicious microcalcifications. MRI reached sensitivity, specificity, positive predictive value 3 (PPV3), and negative predictive value (NPV) of 100%, 70.1%, 67.6%, and 100%, respectively. Statistically significant differences in MRI morphologic features and kinetic enhancement curves were observed between malignant and benign microcalcifications. Sensitivity, specificity, PPV3, and NPV for US were: 85.4%, 66.2%, 61.2%, and 87.9%. There was statistically significant difference in presentation of malignant and benign microcalcifications at US. CONCLUSION: In the setting of conjoined use of mammography, US, and MRI, MRI can reliably exclude malignancy in suspicious microcalcifications. Thus, negative MRI findings may influence the decision to biopsy the microcalcifications.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Calcinose/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Calcinose/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sistemas de Informação em Radiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de DoençaRESUMO
The aim of the study was to quantify the total coronary atherosclerotic burden in patients with suspected coronary artery disease (CAD) defined by coronary computed tomography adapted Leaman score (CT-LeSc) and to estimate its cut-off level for high coronary atherosclerotic burden. We enrolled 434 consecutive patients referred to coronary computed tomography angiography, of which 261 patients fulfilled the study inclusion criteria. Demographic and clinical characteristics, as well as CAD risk factors were obtained. CAD pre-test probabilities were estimated by the Diamond-Forrester model and Morise score. The coronary atherosclerotic burden was estimated using CT-LeSc. As a cut-off for a high coronary atherosclerotic burden, we used 3rd tercile (Tc3) (CT-LeSc ≥ 5.52). We evaluated the association of clinical characteristics and risk factors with Tc3 in univariate and multivariate analysis. There were 60.9% males and 39.1% females, 81% of patients had above-normal weight, 68.2% hypertension, 54.0% dyslipidemia, 15.3% diabetes mellitus, 12.3% positive smoking history and 11.9% had a family history of CAD. According to the Diamond-Forrester model and Morise score the majority of patients had intermediate risk, 59.7 and 52.8%, followed by the high-risk group, 36.0 and 34.4%, respectively. Age, dyslipidemia, hypertension and pre-test risk scores in the univariate analysis significantly predicted Tc3. In the multivariate analysis, male sex (p = 0.004), dyslipidemia (p = 0.002) and coronary calcium score (< 0.001) were identified as predictors of Tc3. CT-LeSc quantified the total coronary atherosclerotic burden and showed an association of risk factors and pre-test probabilities with Tc3.