J Hand Surg Eur Vol ; : 17531934241249919, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780046

RESUMO

Total wrist arthroplasty (TWA) aims to restore pain-free motion to diseased joints. One such TWA, the Motec, has demonstrated good results with acceptable complication rates. It has recently been suggested that the metal-on-carbon fibre reinforced poly ether ether ketone (Mo-CFR-PEEK) version of the Motec TWA be implanted instead of the metal-on-metal version. An explant analysis was undertaken on seven Motec Mo-CFR-PEEK TWAs, revised for a variety of reasons, after a mean time of 2 years in vivo. Compared to a new Motec implant, five of the explanted metal heads and three of the CFR-PEEK cups became smoother in vivo, suggesting self-polishing and negative skewness, indicating some material loss in vivo. Two explanted cups showed indentation marks on their rims and one of these was from component impingement with embedded metallic debris. In the short-term, the articulating surfaces of Motec Mo-CFR-PEEK TWAs did not show major damage.Level of evidence: IV.

2.
J Hand Surg Eur Vol ; 49(1): 34-39, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37666215

RESUMO

We present five cases of osteolysis in the Motec total wrist prosthesis, three around the radial implant, one around the metacarpal implant and one around both. Three of these were progressive and required revision, and biomechanical explant analyses of these revised prostheses were performed. Ex vivo testing of the contact points of the Motec implants was also performed at maximum extension. Here, impingement occurs between the metacarpal screw and the dorsal rim of the cup (non-articulating surfaces) with the short-necked prosthesis, leading to metacarpal screw damage, titanium debris formation and osteolysis. An analysis of three previously published cases suggests that this may have been the likely mode of failure in those cases. This complication is preventable by avoiding use of the short-neck prosthesis.Level of evidence: IV.


Assuntos
Artroplastia de Substituição , Prótese Articular , Osteólise , Humanos , Osteólise/etiologia , Osteólise/cirurgia , Punho , Artroplastia de Substituição/efeitos adversos , Prótese Articular/efeitos adversos , Falha de Prótese , Desenho de Prótese
3.
J Hand Surg Eur Vol ; 49(1): 103-105, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37684020

RESUMO

We examined the learning curve of Motec total wrist arthroplasty (TWA) of six experienced surgeons in their first 30 cases. Three times more complications/revisions were encountered in the first half of the study compared with the second half. Motec TWA surgery should be concentrated in a smaller number of centres performing higher volumes.


Assuntos
Artroplastia de Substituição , Curva de Aprendizado , Humanos , Estudos de Coortes , Punho/cirurgia , Fatores de Tempo , Articulação do Punho/cirurgia
4.
J Hand Surg Eur Vol ; 49(1): 27-33, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37684024

RESUMO

The aim of this study was to analyse the short- and medium-term complications of the Motec total wrist arthroplasty (TWA). Identifying exact modes of failure and their causes should allow surgeons to avoid or mitigate these risks in the future. Retrospective analysis of prospectively collected data from six hand surgeons at five international centres provided details of 171 Motec TWAs. The mean follow-up was 5.8 years (range 18 months to 12 years). There were 33 (19%) complications within our cohort, with a revision rate of 8.2% (14 revisions). There was no difference in complication rates between metal-on-metal and metal-on-polymer articulations. Failure of osseointegration was the most common complication. Problems with soft tissue balancing, implant impingement related osteolysis, bony impingement and metacarpal fracture were found to be other preventable causes of failure in this series. Elimination of these preventable complications will improve survival rates for this implant.Level of evidence: IV.


Assuntos
Artroplastia de Substituição , Punho , Humanos , Estudos de Coortes , Estudos Retrospectivos , Desenho de Prótese , Artroplastia de Substituição/efeitos adversos , Reoperação , Falha de Prótese
5.
J Hand Surg Eur Vol ; : 17531934231220251, 2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38069841

RESUMO

The ReMotion wrist replacement has good short- to medium-term survival with an acceptable complication profile as we previously reported in a cohort of patients with rheumatoid arthritis. We now report the long-term results of the same cohort and details of explant analysis of revisions undertaken for aseptic loosening. A total of 16 wrists were reviewed. Seven prostheses remain in situ with no obvious signs of wear or radiological loosening at a mean follow-up of 15.5 years. Three wrists had been revised: one for infection and two for aseptic loosening. Five patients (six wrists) died 2-9 years after operation from unrelated causes. Explant analysis demonstrated relatively minor wear compared with the published results of the Universal-2 prosthesis. We hypothesize that this may be explained by differences in polyethylene sterilization and prosthetic design. The ReMotion wrist replacement has favourable long-term results in patients with rheumatoid arthritis with a 16-year survival rate of 78%-86%.Level of evidence: IV.

6.
Mil Med ; 188(9-10): 3086-3094, 2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-35446424

RESUMO

BACKGROUND: The majority of critical care air transport (CCAT) flights are regulated, meaning that a theater-validating flight surgeon has confirmed that the patient is medically cleared for flight and that evacuation is appropriate. If the conditions on the ground do not allow for this process, the flight is unregulated. Published data are limited regarding CCAT unregulated missions to include the period of troop drawdown at the end of the Afghanistan conflict. The objective of our study was to characterize the unregulated missions within Afghanistan during troop drawdown and compare them to regulated missions during the same timeframe. STUDY DESIGN: We performed a retrospective review of all CCAT medical records of patients transported via CCAT within Afghanistan between January 2017 and December 2019. We abstracted data from the records, including mission characteristics, patient demographics, injury descriptors, preflight military treatment facility procedures, CCAT procedures, in-flight CCAT treatments, in-flight events, and equipment issues. Following descriptive and comparative analysis, a Cochran-Armitage test was performed to evaluate the statistical significance of the trend in categorical data over time. Multivariable regression was used to assess the association between vasopressors and preflight massive transfusions, preflight surgical procedures, injury patterns, and age. RESULTS: We reviewed 147 records of patients transported via CCAT: 68 patients were transported in a regulated fashion and 79 on an unregulated flight. The number of patients evacuated increased year-over-year (n = 22 in 2017, n = 57 in 2018, and n = 68 in 2019, P < .001), and the percentage of missions that were unregulated grew geometrically (14%, n = 3 in 2017; 37%, n = 21 in 2018; and 81%, n = 55 in 2019, P < .001). During the time studied, CCAT teams were being used more to decompress forward surgical teams (FST) and, therefore, they were transporting patients just hours following initial damage control surgery in an unregulated fashion. In 2 instances, CCAT decompressed an FST following a mass casualty, during which aeromedical evacuation (AE) crews assisted with patient care. For the regulated missions, the treatments that were statistically more common were intravenous fluids, propofol, norepinephrine, any vasopressors, and bicarbonate. During unregulated missions, the statistically more common treatments were ketamine, fentanyl, and 3% saline. Additional analysis of the mechanically ventilated patient subgroup revealed that vasopressors were used twice as often on regulated (38%) vs. unregulated (13%) flights. Multivariable regression analysis demonstrated that traumatic brain injury (TBI) was the only significant predictor of in-flight vasopressor use (odds ratio = 3.53, confidence interval [1.22, 10.22], P = .02). CONCLUSION: During the troop drawdown in Afghanistan, the number of unregulated missions increased geometrically because the medical footprint was decreasing. During unregulated missions, CCAT providers used ketamine more frequently, consistent with Tactical Combat Casualty Care guidelines. In addition, TBI was the only predictor of vasopressor use and may reflect an attempt to adhere to unmonitored TBI clinical guidelines. Interoperability between CCAT and AE teams is critical to meet mass casualty needs in unregulated mission environments and highlights a need for joint training. It remains imperative to evaluate changes in mission requirements to inform en route combat casualty care training.


Assuntos
Resgate Aéreo , Lesões Encefálicas Traumáticas , Ketamina , Militares , Humanos , Afeganistão , Estudos Retrospectivos , Cuidados Críticos/métodos
7.
J Anim Sci ; 100(6)2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35696612

RESUMO

Crossbreeding is a common practice among commercial sheep producers to improve animal performance. However, genetic evaluation of U.S. sheep is performed within breed type (terminal sire, semi-prolific, and western range). While incorporating crossbred records may improve assessment of purebreds, it requires accounting for heterotic and breed effects in the evaluation. The objectives of this study were to: 1) describe the development of a paternal composite (PC) line, 2) determine the effect of direct and maternal heterosis on growth traits of crossbred lambs, 3) estimate (co)variance components for direct and maternal additive, and uncorrelated maternal environmental, effects, and 4) provide an interpretation of the estimates of random effects of genetic groups, and to use those solutions to compare the genetic merit of founding breed subpopulations. Data included purebred and crossbred records on birth weight (BN; n = 14,536), pre-weaning weight measured at 39 or 84 d (WN; n = 9,362) depending on year, weaning weight measured at 123 d (WW; n = 9,297), and post-weaning weight measured at 252 d (PW; n = 1,614). Mean (SD) body weights were 5.3 (1.1), 16.8 (3.9) and 28.0 (7.6), 39.1 (7.2), and 54.2 (8.7) kg for BN, WN (at the two ages), WW, and PW, respectively. In designed experiments, the Siremax, Suffolk, Texel, Polypay, Columbia, Rambouillet, and Targhee breeds were compared within the same environment. Estimates of heterotic effects and covariance components were obtained using a multiple trait animal model. Genetic effects based on founders' breeds were significant and included in the model. Percent estimates of direct heterosis were 2.89 ± 0.61, 2.60 ± 0.65, 4.24 ± 0.56, and 6.09 ± 0.86, and estimates of maternal heterosis were 1.92 ± 0.87, 4.64 ± 0.80, 3.95 ± 0.66, and 4.04 ± 0.91, for BN, WN, WW, and PW, respectively. Correspondingly, direct heritability estimates were 0.17 ± 0.02, 0.13 ± 0.02, 0.17 ± 0.02, and 0.46 ± 0.04 for BN, WN, WW, and PW. Additive maternal effects accounted for trivial variation in PW. For BN, WN, and WW, respectively, maternal heritability estimates were 0.16 ± 0.02, 0.10 ± 0.02, and 0.07 ± 0.01. Uncorrelated maternal environmental effects accounted for little variation in any trait. Direct and maternal heterosis had considerable impact on growth traits, emphasizing the value of crossbreeding and the need to account for heterosis, in addition to breed effects, if crossbred lamb information is included in genetic evaluation.


Crossbreeding is common in commercial sheep enterprises. It allows breeds with different attributes to be combined to generate crossbred progeny tailored to production environments and customer preferences. Additionally, crossbreds often benefit from heterosis, performing at levels above the average of their parental breeds. Over two decades, body weights were collected at birth and at pre-weaning, weaning, and post-weaning ages on purebred and crossbred lambs from semi-prolific (Polypay), western range (Columbia, Rambouillet, Targhee), and terminal sire (Siremax, Suffolk, Texel) breeds at the U.S. Sheep Experiment Station. When combined, the value of direct heterosis­that due to a lamb being crossbred­and maternal heterosis­that due to the lamb's dam being crossbred­increased birth (5%) and post-natal (up to 10%) weights in crossbred lambs. This highlights the value of crossbreeding to the U.S. sheep industry, especially in western range production systems. Genetic variation between and within breeds also was detected for the purebred parental breeds. Such heterotic and breed effects must be accounted for if crossbred performance is to be incorporated in genetic evaluation of purebreds. Therefore, these results provide the foundation for utilizing crossbred information in the evaluation and selection of purebred sheep in the United States.


Assuntos
Vigor Híbrido , Carneiro Doméstico , Animais , Peso ao Nascer/genética , Cruzamentos Genéticos , Vigor Híbrido/genética , Fenótipo , Ovinos/genética , Carneiro Doméstico/genética , Desmame
9.
J Hand Surg Eur Vol ; 46(8): 901-902, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34544308
11.
J Hand Surg Eur Vol ; 46(5): 482-487, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33554712

RESUMO

Reported pin site infection rates in Kirschner wire fixation in the hand and wrist vary from 2% to 35%. In our unit we follow a strict pin site management protocol adapted from the Russian Ilizarov Scientific Centre. This study aims to identify if our current protocol reduces the incidence of pin site infection in hand and wrist surgery, and improves wire survival rates, to a level where exposed wires can be used safely. A retrospective review of 200 patients, treated with 369 percutaneous wires, in our hand surgery department over a 6-year period was carried out. Nine patients (4.5%) were diagnosed with a pin site infection with a wire survival rate of 99.5%.In our unit using our current protocol, results support the safe use of exposed wires with appropriate pin site care initiated in theatre. Adherence to this protocol allows wires to remain in-situ throughout treatment with minimal complications.Level of evidence: IV.


Assuntos
Fixação Interna de Fraturas , Mãos , Fios Ortopédicos , Mãos/cirurgia , Humanos , Incidência , Estudos Retrospectivos
12.
J Hand Surg Eur Vol ; 46(2): 167-171, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32791875

RESUMO

With the introduction of the anterior locking plate in the early part of this century, there was a large change in how distal radial fractures were treated. Early articles about the techniques reported tendon ruptures occurring in as many as 10%, although studies from our unit reported rates closer to 2%. Subsequent refinements in surgical technique and improvements in plate design have been made with the aim of reducing the number of ruptures. Despite this, the original articles and their rates continue to be quoted. In this retrospective study of 798 cases treated with anterior locking plates, tendon ruptures have been significantly reduced and are now as low as 0.5%. Contributing factors leading to this improvement are identified and discussed.Level of evidence: III.


Assuntos
Fraturas do Rádio , Placas Ósseas , Fixação Interna de Fraturas/efeitos adversos , Humanos , Incidência , Fraturas do Rádio/epidemiologia , Fraturas do Rádio/cirurgia , Estudos Retrospectivos , Ruptura/cirurgia , Tendões
13.
J Hand Surg Asian Pac Vol ; 25(4): 441-446, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33115352

RESUMO

Background: Ulnar shortening osteotomy (USO) is a well-established procedure for ulnar impaction syndrome. Various types of osteotomies have been described. Methods: A retrospective cohort study was conducted to compare the results of transverse osteotomy (TO) fixed with a small fragment dynamic compression plate (Synthes, Pennsylvania, USA), to oblique osteotomy (OO) fixed with a procedure specific plate and instrumentation system (Acumed LLC, Oregon, USA). A total of 39 patients underwent TO and 62 patients underwent OO between 2007 and 2016. The main outcomes compared were rate of union, duration of radiological healing, implant removal rate and other complications. Results: The two groups were comparable with regards to demographics, side operated and smoking status (p > 0.05). Amongst the TO group; 36 out of 39 patients (92.3%) achieved union, 3 patients (7.7%) developed non-union. Six out of the 36 healed TO (16.6%) required removal of hardware due to implant-related pain. No other complications were recorded amongst TO group needing surgical intervention. Amongst the OO group, 2 of the early cohort of 62 patients (3.2%) sustained acute failure of the metalwork due to technical error. One of the remaining 60 patients (1.6%) developed non-union giving an overall union rate of 95.2%. Two patients out of 59 healed OO (3.3%) required removal of hardware. Conclusions: Although there were 2 early failures, there was a trend towards improved union rate with OO, but this did not reach statistical significance (p > 0.05). There was a significantly higher hardware removal rate recorded in TO group (p = 0.023). The OO showed shorter duration for radiological healing than TO (p < 0.05). USO performed with an OO and fixed with procedure specific plate has lower implant removal rate, a shorter duration for radiological healing and comparable union rate to TO fixed with DCP, but needs careful attention to detail.


Assuntos
Placas Ósseas , Osteotomia/instrumentação , Osteotomia/métodos , Ulna/cirurgia , Adolescente , Adulto , Idoso , Estudos de Coortes , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Estudos Retrospectivos , Adulto Jovem
14.
J Plast Surg Hand Surg ; 47(6): 481-3, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23596990

RESUMO

This was a prospective study designed to determine what effect poor tolerance to tourniquet application and local anaesthesia infiltration in open carpal tunnel decompression has on overall patient satisfaction with the surgical procedure. Fifty patients were recruited into the study. Visual analogue scores (VAS) were recorded postoperatively for pain related to tourniquet application, local anaesthesia infiltration and the surgical procedure overall. In terms of the procedure, poor tolerance to the tourniquet and local anaesthetic showed no significant relationship to the overall patient satisfaction (Student t-test). The factors, which are related to satisfaction with carpal tunnel decompression, are discussed.


Assuntos
Anestesia Local , Síndrome do Túnel Carpal/cirurgia , Descompressão Cirúrgica , Satisfação do Paciente , Torniquetes , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestésicos Locais/uso terapêutico , Bupivacaína/análogos & derivados , Bupivacaína/uso terapêutico , Feminino , Humanos , Levobupivacaína , Lidocaína/uso terapêutico , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/prevenção & controle , Estudos Prospectivos , Escala Visual Analógica
15.
J Anal Toxicol ; 35(8): 545-50, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22004673

RESUMO

The United States Public Health Service Substance Abuse and Mental Health Services Administration is alerting medical professionals that a substantial percentage of cocaine imported into the United States is adulterated with levamisole, a veterinary pharmaceutical that can cause blood cell disorders such as severe neutropenia and agranulocytosis. Levamisole HCl is the active ingredient in a number of veterinary drugs approved to treat worm infestations in animals. Levamisole HCl was also the active ingredient in a human drug for oral administration approved on June 18, 1990, as adjuvant treatment in combination with fluorouracil after surgical resection in patients with Duke's stage C colon cancer. This drug was withdrawn from the U.S. market around 2000, and it has not been marketed in the U.S. since then. The objective of this study was to develop a method to determine the amount of levamisole in urine samples. The procedure will be provided to state health laboratories as needed to be used in the evaluation of patients that have developed neutropenia or agranulocytosis in the setting of recent cocaine use. A gas chromatography-mass spectrometry method was validated and tested at two different laboratories, and the method limit of detection for levamisole is 1 ng/mL in urine when using a 5-mL sample. Confirmation of the stereoisomer of levamisole was done by high-performance liquid chromatography using a chiral column.


Assuntos
Transtornos Relacionados ao Uso de Cocaína/diagnóstico , Cocaína/urina , Contaminação de Medicamentos , Cromatografia Gasosa-Espectrometria de Massas , Drogas Ilícitas/urina , Levamisol/urina , Detecção do Abuso de Substâncias/métodos , Drogas Veterinárias/urina , Agranulocitose/induzido quimicamente , Calibragem , Cocaína/química , Transtornos Relacionados ao Uso de Cocaína/urina , Cromatografia Gasosa-Espectrometria de Massas/normas , Humanos , Drogas Ilícitas/química , Levamisol/efeitos adversos , Limite de Detecção , Neutropenia/induzido quimicamente , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias/normas , Estados Unidos , Drogas Veterinárias/efeitos adversos
16.
Blood ; 116(18): 3669-76, 2010 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-20631377

RESUMO

The inflammatory response to ionizing radiation (IR) includes a proangiogenic effect that could be counterproductive in cancer but can be exploited for treating impaired wound healing. We demonstrate for the first time that IR stimulates hypoxia-inducible factor-1α (HIF-1α) up-regulation in endothelial cells (ECs), a HIF-1α-independent up-regulation of stromal cell-derived factor-1 (SDF-1), as well as endothelial migration, all of which are essential for angiogenesis. 5 Gray IR-induced EC HIF-1α and SDF-1 expression was greater when combined with hypoxia suggesting an additive effect. While small interfering RNA silencing of HIF-1α mRNA and abolition of HIF-1α protein induction down-regulated SDF-1 induction by hypoxia alone, it had little effect on SDF-1 induction by IR, demonstrating an independent pathway. SDF-1-mediated EC migration in hypoxic and/or radiation-treated media showed IR induced strong SDF-1-dependent migration of ECs, augmented by hypoxia. IR activates a novel pathway stimulating EC migration directly through the expression of SDF-1 independent of HIF-1α induction. These observations might be exploited for stimulation of wound healing or controlling tumor angiogenesis.


Assuntos
Quimiocina CXCL12/genética , Células Endoteliais/efeitos da radiação , Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Transdução de Sinais/efeitos da radiação , Regulação para Cima/efeitos da radiação , Hipóxia Celular , Linhagem Celular , Movimento Celular/efeitos da radiação , Quimiocina CXCL12/metabolismo , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Inativação Gênica , Humanos , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Neovascularização Fisiológica/efeitos da radiação , RNA Mensageiro/genética
17.
Plast Reconstr Surg ; 116(4): 1053-64; discussion 1065-7, 2005 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-16163094

RESUMO

BACKGROUND: Ischemia is a limiting factor during distraction osteogenesis. The authors sought to determine the extent of ischemia in the distraction zone and whether endothelial progenitor cells home to the distraction zone and participate in local vasculogenesis. METHODS: Laser Doppler imaging was used to assess the extent of blood flow in the distraction zone in gradually distracted, immediately distracted, and osteotomized rat mandibles during activation and consolidation. Animals (n = 50; 25 rats with unilateral gradual distraction and contralateral osteotomy as an internal control, and 25 rats with unilateral immediate distraction) were examined on postoperative days 4, 6, and 8 of activation, and after 1 and 2 weeks of consolidation. Endothelial progenitor cells isolated from human peripheral blood were labeled with fluorescent DiI dye, and 0.5 x 10 cells were injected intra-arterially under direct vision into each carotid artery at the start of activation in nude rats (n = 18) that then underwent the distraction protocol outlined above. RESULTS: Doppler flow analysis demonstrated relative ischemia during the activation period in the distraction osteogenesis group and increased blood flow in the osteotomized control group as compared with flow in a normal hemimandible [normal, 1 (standardized); distraction osteogenesis, 0.58 +/- 0.05; control, 2.58 +/- 0.21; p < 0.05 for both results]. We observed a significantly increased endothelial progenitor cell population at the generate site versus controls at midactivation and at 1 and 2 weeks of consolidation [25 +/- 1.9 versus 1 +/- 0.3 DiI-positive cells per high-power field (p < 0.05), 124 +/- 21 versus 8 +/- 4 DiI-positive cells per high-power field (p < 0.05), and 106 +/- 18 versus 9 +/- 3 DiI-positive cells per high-power field (p < 0.05), respectively]. CONCLUSIONS: These data suggest that the distraction zone becomes relatively ischemic during activation and that endothelial progenitor cells home to the ischemic generate site during the activation phase and remain during the consolidation phase. Selective expansion of these stem cells may be useful in overcoming ischemic limitations of distraction osteogenesis. Moreover, their homing capability may be used to effect site-specific transgene delivery to the generate.


Assuntos
Endotélio Vascular/citologia , Mandíbula/irrigação sanguínea , Mandíbula/cirurgia , Osteogênese por Distração , Osteogênese/fisiologia , Células-Tronco/fisiologia , Animais , Isquemia/diagnóstico , Isquemia/fisiopatologia , Fluxometria por Laser-Doppler , Osteogênese por Distração/métodos , Ratos , Ratos Sprague-Dawley , Fatores de Tempo
18.
Ann Plast Surg ; 55(1): 36-41; discussion 41-2, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15985789

RESUMO

Multiple techniques have been employed for the repair of abdominal incisional hernias with varying rates of success. Primary fascial apposition and prosthetic implantation have been associated with high rates of secondary recurrence, infection, and other complications, often due to insufficient alleviation of tension and implant intolerance. This study evaluates the repair of incisional and recurrent abdominal hernias with multilayered acellular dermal allograft (AlloDerm; LifeCell Corporation, Branchburg, NJ) and musculofascial separation. Patients with incisional or recurrent abdominal hernias were treated between January 2003 and March 2004. The surgical technique involved musculofascial release of the external oblique, followed by a double-layer implantation of dermal allograft. The primary allograft layer was placed as an "underlay" interposition, sutured under moderate tension beneath the fascial edges of the defect. When minimal tension remained, the native fascial margins of the defect were directly repaired. A second allograft layer was then placed and sutured to the superficial aspect of the ventral fascia to complete the repair. Data were reviewed retrospectively. Sixteen patients were treated. There were 10 males and 6 females, mean age 56 years (range 44--72 years). Fifteen patients (94%) had previous hernia repair procedures, and 6 patients (38%) had undergone 2 or more previous procedures. Nine patients (56%) were treated with hernia site infections or prosthetic exposure. Mean follow-up is 16 months (range 9 to 23 months). There were 2 seromas (13%). One patient (6%) developed a wound dehiscence with allograft exposure that healed by secondary intention. There were no recurrences. By minimizing tension and providing a durable biocompatible matrix for support, component separation with bilaminar acellular dermal allograft should be considered for the repair of complex and recurrent ventral hernias.


Assuntos
Colágeno/uso terapêutico , Hérnia Abdominal/cirurgia , Adulto , Idoso , Materiais Biocompatíveis/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Recidiva , Pele Artificial , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS