Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 623
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Cancers (Basel) ; 16(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38893214

RESUMO

Microwave ablation (MWA) of liver tumors presents challenges like under- and over-ablation, potentially leading to inadequate tumor destruction and damage to healthy tissue. This study aims to develop personalized three-dimensional (3D) models to simulate MWA for liver tumors, incorporating patient-specific characteristics. The primary objective is to validate the predicted ablation zones compared to clinical outcomes, offering insights into MWA before therapy to facilitate accurate treatment planning. Contrast-enhanced CT images from three patients were used to create 3D models. The simulations used coupled electromagnetic wave propagation and bioheat transfer to estimate the temperature distribution, predicting tumor destruction and ablation margins. The findings indicate that prolonged ablation does not significantly improve tumor destruction once an adequate margin is achieved, although it increases tissue damage. There was a substantial overlap between the clinical ablation zones and the predicted ablation zones. For patient 1, the Dice score was 0.73, indicating high accuracy, with a sensitivity of 0.72 and a specificity of 0.76. For patient 2, the Dice score was 0.86, with a sensitivity of 0.79 and a specificity of 0.96. For patient 3, the Dice score was 0.8, with a sensitivity of 0.85 and a specificity of 0.74. Patient-specific 3D models demonstrate potential in accurately predicting ablation zones and optimizing MWA treatment strategies.

2.
J Gastrointest Surg ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38754809

RESUMO

BACKGROUND: Liver-directed treatments - ablative therapy (AT), surgical resection (SR), liver transplantation (LT), and transarterial chemoembolization (TACE) - improve the overall survival of patients with early-stage hepatocellular carcinoma (HCC). Although racial and socioeconomic disparities affect access to liver-directed therapies, the temporal trends for the curative-intent treatment of HCC remain to be elucidated. METHODS: This study performed chi-square, logistic regression, and temporal trends analyses on data from the Nationwide Inpatient Sample from 2011 to 2019. The outcome of interest was the rate of AT, SR, LT (curative-intent treatments), and TACE utilization, and the primary predictors were racial/ethnic group and socioeconomic status (SES; insurance status). RESULTS: African American and Hispanic patients had lower odds of receiving AT (African American: odds ratio [OR], 0.78; P < .001; Hispanic: OR, 0.84; P = .005) and SR (African American: OR, 0.71; P < .001; Hispanics: OR, 0.64; P < .001) than White patients. Compared with White patients, the odds of LT was lower in African American patients (OR, 0.76; P < .001) but higher in Hispanic patients (OR, 1.25; P = .001). Low SES was associated with worse odds of AT (OR, 0.79; P = .001), SR (OR, 0.66; P < .001), and LT (OR, 0.84; P = .028) compared with high SES. Although curative-intent treatments showed significant upward temporal trends among White patients (10.6%-13.9%; P < .001) and Asian and Pacific Islander/other patients (14.4%-15.7%; P = .007), there were nonsignificant trends among African American patients (10.9%-10.1%; P = .825) or Hispanic patients (12.2%-13.7%; P = .056). CONCLUSION: Our study demonstrated concerning disparities in the utilization of curative-intent treatment for HCC based on race/ethnicity and SES. Moreover, racial/ethnic disparities have widened rather than improved over time.

3.
Talanta ; 275: 126154, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38703477

RESUMO

Additive manufacturing is a technique that allows the construction of prototypes and has evolved a lot in the last 20 years, innovating industrial fabrication processes in several areas. In chemistry, additive manufacturing has been used in several functionalities, such as microfluidic analytical devices, energy storage devices, and electrochemical sensors. Theophylline and paracetamol are important pharmaceutical drugs where overdosing can cause adverse effects, such as tachycardia, seizures, and even renal failure. Therefore, this paper aims at the development of miniaturized electrochemical sensors using 3D printing and polylactic acid-based conductive carbon black commercial filament for theophylline and paracetamol detection. Electrochemical characterizations of the proposed sensor were performed to prove the functionality of the device. Morphological characterizations were carried out, in which chemical treatment could change the surface structure, causing the improvement of the analytical signal. Thus, the detection of theophylline at a linear range of 5.00-150 µmol L-1 with a limit of detection of 1.2 µmol L-1 was attained, and the detection of paracetamol at a linear range of 1.00-200 µmol L-1 with a limit of detection of 0.370 µmol L-1 was obtained, demonstrating the proposed sensor effectively detected pharmaceutical drugs.


Assuntos
Acetaminofen , Técnicas Eletroquímicas , Poliésteres , Fuligem , Teofilina , Acetaminofen/análise , Fuligem/química , Técnicas Eletroquímicas/métodos , Teofilina/análise , Poliésteres/química , Limite de Detecção , Impressão Tridimensional , Miniaturização
5.
Cancers (Basel) ; 16(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38791894

RESUMO

BACKGROUND: Our purpose is to evaluate the long-term oncologic efficacy and survival rates of MRI-guided cryoablation for patients with biopsy-proven cT1a renal cell carcinoma (RCC). MATERIALS AND METHODS: We retrospectively reviewed our renal ablation database between January 2007 and June 2021 and only included patients with solitary-biopsy-proven cT1a RCC (≤4 cm) who underwent MRI-guided cryoablation. We excluded patients with genetic syndromes, bilateral RCC, recurrent RCC or benign lesions, those without pathologically proven RCC lesions and patients who underwent radiofrequency ablation or CT-guided cryoablation. For each patient, we collected the following: age, sex, lesion size, right- or left-sided, pathology, ablation zone tumor recurrence, development of new tumor in the kidney other than ablation zone, development of metastatic disease, patient alive or not, date and cause of death. We used the Kaplan and Meier product limit estimator to estimate the survival outcomes. RESULTS: Twenty-nine patients (median age 70 years) met our inclusion criteria. Twenty-nine MRI-guided cryoablation procedures were performed for twenty-nine tumor lesions with a median size of 2.2 cm. A Clavien-Dindo grade III complication developed in one patient (3.4%). Clear cell RCC was the most reported histology (n = 19). The median follow up was 4.5 years. No tumor recurrence or metastatic disease developed in any of the patients. Two patients developed new renal lesions separate from the ablation zone. The 5- and 10-year OS were 72% and 55.6%, respectively. The 5- and 10-year DFS were 90.5% and the 5-year and 10-year LRFS, MFS and CSS were all 100%. CONCLUSIONS: MRI-guided cryoablation is a safe treatment with a low complication rate. Long-term follow-up data revealed long-standing oncologic control.

6.
J Vasc Interv Radiol ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38719091

RESUMO

The purpose of this study was to evaluate the technical success, effectiveness, and safety of transarterial embolization for acute bleeding management with a shear-thinning conformable embolic. This single-center retrospective study evaluated outcomes after embolization using Obsidio conformable embolic (OCE). Technical success was defined as performing transarterial embolization within the target vessel to complete stasis of antegrade flow. Treatment effectiveness was defined as cessation of bleeding for patients. Eleven patients underwent 11 embolization procedures. A total of 16 arteries were embolized. Indications for embolization were spontaneous tumor bleeding (6/11), hematuria (2/11), active duodenal bleeding (1/11), portal hypertensive bleeding (1/11), and rectus sheath hematoma (1/11). The technical success rate was 100%. The median vessel diameter was 2 mm (range, 1-3 mm). There were no adverse events or off-target embolization. OCE demonstrated technical success and treatment effectiveness with a short-term safety profile for transarterial embolization interventions.

7.
Cancer ; 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642369

RESUMO

PURPOSE: To evaluate outcomes following percutaneous image-guided ablation of soft tissue sarcoma metastases to the liver. MATERIALS AND METHODS: A single-institution retrospective analysis of patients with a diagnosis of metastatic soft tissue sarcoma who underwent percutaneous image-guided ablation of hepatic metastases between January 2011 and December 2021 was performed. Patients with less than 60 days of follow-up after ablation were excluded. The primary outcome was local tumor progression-free survival (LPFS). Secondary outcomes included overall survival, liver-specific progression-free survival. and chemotherapy-free survival. RESULTS: Fifty-five patients who underwent percutaneous ablation for 84 metastatic liver lesions were included. The most common histopathological subtypes were leiomyosarcoma (23/55), followed by gastrointestinal stromal tumor (22/55). The median treated liver lesions was 2 (range, 1-8), whereas the median size of metastases were 1.8 cm (0.3-8.7 cm). Complete response at 2 months was achieved in 90.5% of the treated lesions. LPFS was 83% at 1 year and 80% at 2 years. Liver-specific progression-free survival was 66% at 1 year and 40% at 2 years. The overall survival at 1 and 2 years was 98% and 94%. The chemotherapy-free holiday from the start of ablation was 71.2% at 12 months. The complication rate was 3.6% (2/55); one of the complications was Common Terminology Criteria for Adverse Events grade 3 or higher. LPFS subgroup analysis for leiomyosarcoma versus gastrointestinal stromal tumor suggests histology-agnostic outcomes (2 years, 89% vs 82%, p = .35). CONCLUSION: Percutaneous image-guided liver ablation of soft tissue sarcoma metastases is safe and efficacious.

8.
J Am Coll Surg ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661145

RESUMO

BACKGROUND: The direct association between procedure risk and outcomes in elderly emergency general surgery (EGS) patients has not been analyzed. Studies only highlight the importance of frailty. A comprehensive analysis of relevant risk factors and their association with outcomes in elderly EGS patients is lacking. We hypothesized that procedure risk has a stronger association with relevant outcomes in elderly EGS patients compared to frailty. STUDY DESIGN: Elderly patients (age > 65) undergoing emergency general surgery operative procedures were identified in the NSQIP) database (2018 to 2020) and stratified based on the presence of frailty calculated by the Modified 5 Item Frailty Index (mFI-5; mFI 0 Non-Frail, mFI 1-2 Frail, and mFI ≥3 Severely Frail) and based on procedure risk. Multivariable regression models and Receiving Operative Curve (ROC) analysis were used to determine risk factors associated with outcomes. RESULTS: A total of 59,633 elderly EGS patients were classified into non-frail (17,496; 29.3%), frail (39,588; 66.4%), and severely frail (2,549; 4.3%). There were 25,157 patients in the low-risk procedure group and 34,476 in the high-risk group.Frailty and procedure risk were associated with increased mortality, complications, failure to rescue, and readmissions. Differences in outcomes were greater when patients were stratified according to procedure risk compared to frailty stratification alone. Procedure risk had a stronger association with relevant outcomes in elderly EGS patients compared to frailty. CONCLUSIONS: Assessing frailty in the elderly EGS patient population without adjusting for the type of procedure or procedure risk ultimately presents an incomplete representation of how frailty impacts patient-related outcomes.

9.
J Gastrointest Surg ; 28(5): 766-775, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38519362

RESUMO

BACKGROUND: Postoperative hepatic insufficiency (PHI) is the most feared complication after hepatectomy. Volume of the future liver remnant (FLR) is one objectively measurable indicator to identify patients at risk of PHI. In this review, we summarized the development and rationale for the use of liver volumetry and liver-regenerative interventions and highlighted emerging tools that could yield new advancements in liver volumetry. METHODS: A review of MEDLINE/PubMed, Embase, and Cochrane Library databases was conducted to identify literature related to liver volumetry. The references of relevant articles were reviewed to identify additional publications. RESULTS: Liver volumetry based on radiologic imaging was developed in the 1980s to identify patients at risk of PHI and later used in the 1990s to evaluate grafts for living donor living transplantation. The field evolved in the 2000s by the introduction of standardized FLR based on the hepatic metabolic demands and in the 2010s by the introduction of the degree of hypertrophy and kinetic growth rate as measures of the FLR regenerative and functional capacity. Several liver-regenerative interventions, most notably portal vein embolization, are used to increase resectability and reduce the risk of PHI. In parallel with the increase in automation and machine assistance to physicians, many semi- and fully automated tools are being developed to facilitate liver volumetry. CONCLUSION: Liver volumetry is the most reliable tool to detect patients at risk of PHI. Advances in imaging analysis technologies, newly developed functional measures, and liver-regenerative interventions have been improving our ability to perform safe hepatectomy.


Assuntos
Hepatectomia , Regeneração Hepática , Fígado , Humanos , Hepatectomia/métodos , Tamanho do Órgão , Fígado/diagnóstico por imagem , Fígado/cirurgia , Insuficiência Hepática/etiologia , Embolização Terapêutica/métodos , Complicações Pós-Operatórias/etiologia , Transplante de Fígado/métodos , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia
10.
Cancers (Basel) ; 16(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38539527

RESUMO

With the rapidly evolving field of image-guided tumor ablation, there is an increasing demand and need for tools to optimize treatment success. Known factors affecting the success of (non-)thermal liver ablation procedures are the ability to optimize tumor and surrounding critical structure visualization, ablation applicator targeting, and ablation zone confirmation. A recent study showed superior local tumor progression-free survival and local control outcomes when using transcatheter computed tomography hepatic angiography (CTHA) guidance in percutaneous liver ablation procedures. This pictorial review provides eight clinical cases from three institutions, MD Anderson (Houston, TX, USA), Gustave Roussy (Paris, France), and Amsterdam UMC (Amsterdam, The Netherlands), with the intent to demonstrate the added value of real-time CTHA guided tumor ablation for primary liver tumors and liver-only metastatic disease. The clinical illustrations highlight the ability to improve the detectability of the initial target liver tumor(s) and identify surrounding critical vascular structures, detect 'vanished' and/or additional tumors intraprocedurally, differentiate local tumor progression from non-enhancing scar tissue, and promptly detect and respond to iatrogenic hemorrhagic events. Although at the cost of adding a minor but safe intervention, CTHA-guided liver tumor ablation minimizes complications of the actual ablation procedure, reduces the number of repeat ablations, and improves the oncological outcome of patients with liver malignancies. Therefore, we recommend adopting CTHA as a potential quality-improving guiding method within the (inter)national standards of practice.

11.
Eur Radiol ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334762

RESUMO

PURPOSE: To investigate the correlation of minimal ablative margin (MAM) quantification using biomechanical deformable (DIR) versus intensity-based rigid image registration (RIR) with local outcomes following colorectal liver metastasis (CLM) thermal ablation. METHODS: This retrospective single-institution study included consecutive patients undergoing thermal ablation between May 2016 and October 2021. Patients who did not have intraprocedural pre- and post-ablation contrast-enhanced CT images for MAM quantification or follow-up period less than 1 year without residual tumor or local tumor progression (LTP) were excluded. DIR and RIR methods were used to quantify the MAM. The registration accuracy was compared using Dice similarity coefficient (DSC). Area under the receiver operating characteristic curve (AUC) was used to test MAM in predicting local tumor outcomes. RESULTS: A total of 72 patients (mean age 57; 44 men) with 139 tumors (mean diameter 1.5 cm ± 0.8 (SD)) were included. During a median follow-up of 29.4 months, there was one residual unablated tumor and the LTP rate was 17% (24/138). The ranges of DSC were 0.96-0.98 and 0.67-0.98 for DIR and RIR, respectively (p < 0.001). When using DIR, 27 (19%) tumors were partially or totally registered outside the liver, compared to 46 (33%) with RIR. Using DIR versus RIR, the corresponding median MAM was 4.7 mm versus 4.0 mm, respectively (p = 0.5). The AUC in predicting residual tumor and 1-year LTP for DIR versus RIR was 0.89 versus 0.72, respectively (p < 0.001). CONCLUSION: Ablative margin quantified on intra-procedural CT imaging using DIR method outperformed RIR for predicting local outcomes of CLM thermal ablation. CLINICAL RELEVANCE STATEMENT: The study supports the role of biomechanical deformable image registration as the preferred image registration method over rigid image registration for quantifying minimal ablative margins using intraprocedural contrast-enhanced CT images. KEY POINTS: • Accurate and reproducible image registration is a prerequisite for clinical application of image-based ablation confirmation methods. • When compared to intensity-based rigid image registration, biomechanical deformable image registration for minimal ablative margin quantification was more accurate for liver registration using intraprocedural contrast-enhanced CT images. • Biomechanical deformable image registration outperformed intensity-based rigid image registration for predicting local tumor outcomes following colorectal liver metastasis thermal ablation.

12.
Radiol Imaging Cancer ; 6(2): e230099, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38363196

RESUMO

CT during hepatic arteriography (CTHA) is a highly sensitive imaging method for detecting colorectal liver metastases (CLMs), which supports its use during percutaneous thermal liver ablation. In contrast to its high sensitivity, its specificity for incidental small CLMs not detected at preablation cross-sectional imaging is believed to be low given the absence of specific imaging signatures and the common presence of pseudolesions. In this retrospective study of 22 patients (mean age, 55 years ± 10.6 [SD]; 63.6% male, 36.4% female) with CLMs undergoing CTHA-guided microwave percutaneous thermal ablation between November 2017 and October 2022, the authors provided a definition of incidental ring-hyperenhancing liver micronodules (RHLMs) and investigated whether there is a correlation of RHLMs with histologic analysis or intrahepatic tumor progression at imaging follow-up after applying a biomechanical deformable image registration method. The analysis revealed 25 incidental RHLMs in 41.7% (10 of 24) of the CTHA images from the respective guided ablation sessions. Of those, four RHLMs were ablated. Among the remaining 21 RHLMs, 71.4% (15 of 21) were confirmed to be CLM with either histology (n = 3) or imaging follow-up (n = 12). The remaining 28.6% (six of 21) of RHLMs were not observed at follow-up imaging. This suggests that RHLMs at CTHA may be an early indicator of incidental small CLMs. Keywords: Colorectal Neoplasms, Liver, Angiography, CT, Incidental Findings, Ablation Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Colorretais/diagnóstico por imagem , Angiografia/métodos , Tomografia Computadorizada por Raios X/métodos
13.
Eur Radiol ; 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38400904

RESUMO

OBJECTIVES: To evaluate the technical success and outcomes of renal biopsies performed under magnetic resonance imaging (MRI) using a closed-bore, 1.5-Tesla MRI unit. MATERIALS AND METHODS: We retrospectively reviewed our institutional biopsy database and included 150 consecutive MRI-guided biopsies for renal masses between November 2007 and March 2020. We recorded age, sex, BMI, tumor characteristics, RENAL nephrometry score, MRI scan sequence, biopsy technique, complications, diagnostic yield, pathologic outcome, and follow-up imaging. Univariate logistic regression was used to assess the association between different parameters and the development of complications. McNemar's test was used to assess the association between paired diagnostic yield measurements for fine-needle aspiration and core samples. RESULTS: A total of 150 biopsies for 150 lesions were performed in 150 patients. The median tumor size was 2.7 cm. The median BMI was 28.3. The lesions were solid, partially necrotic/cystic, and predominantly cystic in 137, eight, and five patients, respectively. Image guidance using fat saturation steady-state free precession sequence was recorded in 95% of the biopsy procedures. Samples were obtained using both fine-needle aspiration (FNA) and cores in 99 patients (66%), cores only in 40 (26%), and FNA only in three (2%). Tissue sampling was diagnostic in 144 (96%) lesions. No major complication developed following any of the biopsy procedures. The median follow-up imaging duration was 8 years and none of the patients developed biopsy-related long-term complication or tumor seeding. CONCLUSIONS: MRI-guided renal biopsy is safe and effective, with high diagnostic yield and no major complications. CLINICAL RELEVANCE STATEMENT: Image-guided renal biopsy is safe and effective, and should be included in the management algorithm of patients with renal masses. Core biopsy is recommended. KEY POINTS: • MRI-guided biopsy is a safe and effective technique for sampling of renal lesions. • MRI-guided biopsy has high diagnostic yield with no major complications. • Percutaneous image-guided biopsy plays a key role in the management of patients with renal masses.

14.
Sci Rep ; 14(1): 4678, 2024 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409252

RESUMO

Manual delineation of liver segments on computed tomography (CT) images for primary/secondary liver cancer (LC) patients is time-intensive and prone to inter/intra-observer variability. Therefore, we developed a deep-learning-based model to auto-contour liver segments and spleen on contrast-enhanced CT (CECT) images. We trained two models using 3d patch-based attention U-Net ([Formula: see text] and 3d full resolution of nnU-Net ([Formula: see text] to determine the best architecture ([Formula: see text]. BA was used with vessels ([Formula: see text] and spleen ([Formula: see text] to assess the impact on segment contouring. Models were trained, validated, and tested on 160 ([Formula: see text]), 40 ([Formula: see text]), 33 ([Formula: see text]), 25 (CCH) and 20 (CPVE) CECT of LC patients. [Formula: see text] outperformed [Formula: see text] across all segments with median differences in Dice similarity coefficients (DSC) ranging 0.03-0.05 (p < 0.05). [Formula: see text], and [Formula: see text] were not statistically different (p > 0.05), however, both were slightly better than [Formula: see text] by DSC up to 0.02. The final model, [Formula: see text], showed a mean DSC of 0.89, 0.82, 0.88, 0.87, 0.96, and 0.95 for segments 1, 2, 3, 4, 5-8, and spleen, respectively on entire test sets. Qualitatively, more than 85% of cases showed a Likert score [Formula: see text] 3 on test sets. Our final model provides clinically acceptable contours of liver segments and spleen which are usable in treatment planning.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Baço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
15.
Mikrochim Acta ; 191(2): 96, 2024 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-38225436

RESUMO

The combination of multi-walled carbon nanotubes (MWCNT) and carbon black (CB) is presented to produce a high-performance electrically conductive recycled additive manufacturing filament. The filament and subsequent additively manufactured electrodes were characterised by TGA, XPS, Raman, and SEM and showed excellent low-temperature flexibility. The MWCNT/CB filament exhibited an improved electrochemical performance compared to an identical in-house produced bespoke filament using only CB. A heterogeneous electrochemical rate constant, [Formula: see text] of 1.71 (± 0.19) × 10-3 cm s-1 was obtained, showing an almost six times improvement over the commonly used commercial conductive CB/PLA. The filament was successfully tested for the simultaneous determination of acetaminophen and phenylephrine, producing linear ranges of 5-60 and 5-200 µM, sensitivities of 0.05 µA µM-1 and 0.14 µA µM-1, and limits of detection of 0.04 µM and 0.38 µM, respectively. A print-at-home device is presented where a removable lid comprised of rPLA can be placed onto a drinking vessel and the working, counter, and reference components made from our bespoke MWCNT/CB filament. The print-at-home device was successfully used to determine both compounds within real pharmaceutical products, with recoveries between 87 and 120% over a range of three real samples. This work paves the way for fabricating new highly conductive filaments using a combination of carbon materials with different morphologies and physicochemical properties and their application to produce additively manufactured electrodes with greatly improved electrochemical performance.


Assuntos
Acetaminofen , Nanotubos de Carbono , Acetaminofen/análise , Nanotubos de Carbono/química , Fuligem , Fenilefrina , Técnicas Eletroquímicas
16.
Appl Radiat Isot ; 205: 111181, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38244325

RESUMO

PURPOSE: Body composition analysis using computed tomography (CT) is proposed as a predictor of cancer mortality. An association between subcutaneous adipose tissue radiodensity (SATr) and cancer-specific mortality was established, while gender effects and equipment bias were estimated. METHODS: 7,475 CT studies were selected from 17 cohorts containing CT images of untreated cancer patients who underwent follow-up for a period of 2.1-118.8 months. SATr measures were collected from published data (n = 6,718) or calculated according to CT images using a deep-learning network (n = 757). The association between SATr and mortality was ascertained for each cohort and gender using the p-value from either logistic regression or ROC analysis. The Kruskal-Wallis test was used to analyze differences between gender distributions, and automatic segmentation was evaluated using the Dice score and five-point Likert quality scale. Gender effect, scanner bias and changes in the Hounsfield unit (HU) to detect hazards were also estimated. RESULTS: Higher SATr was associated with mortality in eight cancer types (p < 0.05). Automatic segmentation produced a score of 0.949 while the quality scale measurement was good to excellent. The extent of gender effect was 5.2 HU while the scanner bias was 10.3 HU. The minimum proposed HU change to detect a patient at risk of death was between 5.6 and 8.3 HU. CONCLUSIONS: CT imaging provides valuable assessments of body composition as part of the staging process for several cancer types, saving both time and cost. Gender specific scales and scanner bias adjustments should be carried out to successfully implement SATr measures in clinical practice.


Assuntos
Neoplasias , Humanos , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Gordura Subcutânea/diagnóstico por imagem , Tecido Adiposo
17.
Leukemia ; 38(1): 58-66, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37935977

RESUMO

Prior experience indicated that use of higher doses of cytarabine during induction for acute myeloid leukemia (AML) with a histone deacetylase inhibitor resulted in high response rates. S1203 was a randomized multicenter trial for previously untreated patients aged 18-60 with AML which compared daunorubicin and cytarabine (DA), idarubicin with higher dose cytarabine (IA) and IA with vorinostat (IA + V). The primary endpoint was event free survival (EFS). 738 patients were randomized: 261 to each DA and IA arms and 216 to the IA + V arm. 96, 456, and 150 patients had favorable-, intermediate-, and unfavorable-risk cytogenetics, respectively. 152 were NPM1 and 158 FLT3 mutated. The overall remission rate was 77.5% including 62.5% CR and 15.0% CRi. No differences in remission, EFS, or overall survival were observed among the 3 arms except for the favorable cytogenetics subset who had improved outcomes with DA and postremission high dose cytarabine. A trend towards increased toxicity was observed with the IA and IA + V arms. The use of higher dose cytarabine during induction therapy in younger patients with AML, with or without vorinostat, does not result in improved outcomes. (Funded by the US National Institutes of Health and others, ClinicalTrials.gov number, NCT01802333.).


Assuntos
Citarabina , Leucemia Mieloide Aguda , Humanos , Vorinostat/uso terapêutico , Daunorrubicina , Idarubicina/uso terapêutico , Indução de Remissão , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos
18.
Cancer Chemother Pharmacol ; 93(4): 329-339, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38036720

RESUMO

PURPOSE: Eftozanermin alfa is a second-generation tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) receptor agonist that enhances death receptor 4/5 clustering on tumor cells to induce apoptosis. We report the pharmacokinetics and immunogenicity of eftozanermin alfa administered intravenously to 153 adults with previously-treated solid tumors or hematologic malignancies from the first-in-human, open-label, dose-escalation and dose-optimization study. METHODS: Dose escalation evaluated eftozanermin alfa monotherapy 2.5-15 mg/kg on Day 1 or Days 1/8 of a 21-day cycle. Dose optimization evaluated eftozanermin alfa monotherapy or combination therapy with either oral venetoclax 400-800 mg daily (eftozanermin alfa 1.25-7.5 mg/kg Days 1/8/15 of a 21-day cycle) or chemotherapy (eftozanermin alfa 3.75 or 7.5 mg/kg Days 1/8/15/22 of a 28-day cycle and FOLFIRI regimen [leucovorin, 5-fluorouracil, and irinotecan] with/without bevacizumab on Days 1/15 of a 28-day cycle). RESULTS: Systemic exposures (maximum observed concentration [Cmax] and area under the concentration-time curve [AUC]) of eftozanermin alfa were approximately dose-proportional across the entire dose escalation range with minimal to no accumulation in Cycle 3 versus Cycle 1 exposures. Comparable exposures and harmonic mean half-lives (35.1 h [solid tumors], 31.3 h [hematologic malignancies]) were observed between malignancy types. Exposures (dose-normalized Cmax and AUC) in Japanese subjects were similar to non-Japanese subjects. Furthermore, eftozanermin alfa/venetoclax combination therapy did not have an impact on the exposures of either agent. Treatment-emergent anti-drug antibodies were observed in 9.4% (13/138) of subjects. CONCLUSIONS: The study results, including a pharmacokinetic profile consistent with weekly dosing and low incidence of immunogenicity, support further investigation of eftozanermin alfa. TRIAL REGISTRATION ID: NCT03082209.


Assuntos
Antineoplásicos , Compostos Bicíclicos Heterocíclicos com Pontes , Neoplasias Hematológicas , Neoplasias , Adulto , Humanos , Antineoplásicos/efeitos adversos , Neoplasias/tratamento farmacológico , Neoplasias/patologia , Sulfonamidas , Neoplasias Hematológicas/tratamento farmacológico
19.
Invest Radiol ; 59(4): 314-319, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812469

RESUMO

OBJECTIVES: The aim of this study was to investigate the prognostic value of 3-dimensional minimal ablative margin (MAM) quantified by intraprocedural versus initial follow-up computed tomography (CT) in predicting local tumor progression (LTP) after colorectal liver metastasis (CLM) thermal ablation. MATERIALS AND METHODS: This single-institution, patient-clustered, tumor-based retrospective study included patients undergoing microwave and radiofrequency ablation between 2016 and 2021. Patients without intraprocedural and initial follow-up contrast-enhanced CT, residual tumors, or with follow-up less than 1 year without LTP were excluded. Minimal ablative margin was quantified by a biomechanical deformable image registration method with segmentations of CLMs on intraprocedural preablation CT and ablation zones on intraprocedural postablation and initial follow-up CT. Prognostic value of MAM to predict LTP was tested using area under the curve and competing-risk regression model. RESULTS: A total of 68 patients (mean age ± standard deviation, 57 ± 12 years; 43 men) with 133 CLMs were included. During a median follow-up of 30.3 months, LTP rate was 17% (22/133). The median volume of ablation zone was 27 mL and 16 mL segmented on intraprocedural and initial follow-up CT, respectively ( P < 0.001), with corresponding median MAM of 4.7 mm and 0 mm, respectively ( P < 0.001). The area under the curve was higher for MAM quantified on intraprocedural CT (0.89; 95% confidence interval [CI], 0.83-0.94) compared with initial follow-up CT (0.66; 95% CI, 0.54-0.76) in predicting 1-year LTP ( P < 0.001). An MAM of 0 mm on intraprocedural CT was an independent predictor of LTP with a subdistribution hazards ratio of 11.9 (95% CI, 4.9-28.9; P < 0.001), compared with 2.4 (95% CI, 0.9-6.0; P = 0.07) on initial follow-up CT. CONCLUSIONS: Ablative margin quantified on intraprocedural CT significantly outperformed initial follow-up CT in predicting LTP and should be used for ablation endpoint assessment.


Assuntos
Ablação por Cateter , Neoplasias Colorretais , Neoplasias Hepáticas , Masculino , Humanos , Seguimentos , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Colorretais/patologia
20.
Ann Surg Oncol ; 31(4): 2547-2556, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38148351

RESUMO

BACKGROUND: Early recurrence following hepatectomy for colorectal liver metastases (CLM) is associated with worse survival; yet, impact of further local therapy is unclear. We sought to evaluate whether local therapy benefits patients with early recurrence following hepatectomy for CLM. METHODS: Clinicopathologic and survival outcomes of patients managed with hepatectomy for CLM (1/2001-12/2020) were queried from a prospectively maintained database. Timing of recurrence was stratified as early (recurrence-free survival [RFS] < 6 months), intermediate (RFS 6-12 months), and later (RFS > 12 months). Local therapy was defined as ablation, resection, or radiation. RESULTS: Of 671 patients, 541 (81%) recurred with 189 (28%) early, 180 (27%) intermediate, and 172 (26%) later recurrences. Local therapy for recurrence resulted in improved survival, regardless of recurrence timing (early 78 vs. 32 months, intermediate 72 vs. 39 months, later 132 vs. 65 months, all p < 0.001). Following recurrence, treatment with local therapy (hazard ratio [HR] = 0.24), liver and extrahepatic recurrence (HR = 1.81), RAS + TP53 co-mutation (HR = 1.52), and SMAD4 mutation (HR = 1.92) were independently associated with overall survival (all p ≤ 0.002). Among patients with recurrence treated by local therapy, patients older than 65 years (HR 1.79), liver and extrahepatic recurrence (HR 2.05), primary site or other recurrence (HR 1.90), RAS-TP53 co-mutation (HR 1.63), and SMAD4 mutation (HR 2.06) had shorter post-local therapy survival (all p ≤ 0.04). CONCLUSIONS: While most patients recur after hepatectomy for CLM, local therapy may result in long-term survival despite early recurrence. Somatic mutational profiling may help to guide the multidisciplinary consideration of local therapy after recurrence.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Prognóstico , Neoplasias Colorretais/patologia , Hepatectomia , Modelos de Riscos Proporcionais , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/genética , Recidiva Local de Neoplasia/patologia , Taxa de Sobrevida , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA