Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Surg Orthop Adv ; 27(1): 6-9, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29762108

RESUMO

Glenoid component aseptic loosening is the most common source of total shoulder arthroplasty (TSA) revision. Divergent pegged glenoids may improve fixation. Thirty-four patients underwent divergent peg TSA. Data were reviewed for component loosening. Failure was defined as the need for revision after loosening. The last postoperative radiographs were graded on a Lazarus glenoid lucency scale. Mean follow-up was 5.6 years ± 2.44 (range, 2-10 years). Radiolucency around one or fewer pegs was noted in 14/20 patients. Six glenoids had complete radiolucency around two pegs; one shoulder had gross loosening. No secondary surgery was performed. Improvements were seen in active elevation and internal rotation. The mean Shoulder Pain and Disability Index (SPADI) score decreased by 48.1 points (p = .039). Shoulder elevation, internal rotation, and SPADI scores significantly improved at final follow-up. No patients underwent revision for glenoid loosening. There were, however, a significant number of patients with radiolucency around two pegs. (Journal of Surgical Orthopaedic Advances 27(1):6-9, 2018).


Assuntos
Artroplastia do Ombro/métodos , Osteoartrite/cirurgia , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos
2.
J Orthop ; 12(2): 92-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25972700

RESUMO

PURPOSE: This pilot study tested whether FiberWire provides similar protection to steel wire against repair displacement in patella fractures. METHODS: Thirteen cadaver knees were cyclically loaded with 10 cycles (0-90° flexion) and fracture displacement was recorded. Fixation methods were also tested in load to failure (>3 mm displacement). RESULTS: There was no difference between wire types in fracture displacement (1.4 mm ± 0.33 mm vs 1.2 mm ± 0.34 mm, respectively; p = 0.418) or in the load to failure (714.7 N ± 110.9 N vs 744.5 N ± 92.8 N, respectively; p = 0.360). CONCLUSION: FiberWire provides similar protection to steel wire against repair displacement after fixation of patellar fractures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA