1.
Laryngoscope ; 132(11): 2148-2156, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-34894356

RESUMO

OBJECTIVES/HYPOTHESIS: To establish the utility of anatomic optical coherence tomography (aOCT) in evaluating internal nasal valve (INV). STUDY DESIGN: Anatomic specimen imaging study. METHODS: Fresh-harvested human specimen heads were evaluated using both computed tomography (CT) imaging as well as using aOCT. Scans were performed at three time points: 1) After septoplasty for cartilage harvest, 2) after placement of butterfly graft (BFG), and 3) after placement of bilateral spreader grafts (SG). Imaging data were then converted into 3D models of the nasal airway. CT- and aOCT-generated models were compared by both static volumetric analysis and computational fluid dynamics (CFD) to predict nasal resistance and pressure. RESULTS: Scans using aOCT showed comparable results to CT in terms of volumetric parameters both before and after intervention. Analysis of aOCT data by CFD demonstrated decrease in pressure after SG or BFG intervention. No statistically significant difference was observed when comparing CT- and aOCT-generated calculations of pressure or resistance. CONCLUSION: The INV can be imaged in a static fashion using aOCT technology. Advantages over traditional CT imaging include lack of exposure to radiation and rapid scan time. In addition, in-office use is possible as aOCT technology develops. Further investigation will be necessary to define the role of aOCT in the dynamic evaluation of this vital component of the nasal airway. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:2148-2156, 2022.


Assuntos
Obstrução Nasal , Rinoplastia , Humanos , Hidrodinâmica , Obstrução Nasal/cirurgia , Septo Nasal/diagnóstico por imagem , Septo Nasal/cirurgia , Nariz/cirurgia , Rinoplastia/métodos , Tomografia de Coerência Óptica/métodos , Tomografia Computadorizada por Raios X/métodos
2.
J Biomed Opt ; 25(1): 1-11, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31912688

RESUMO

Objective measurement of the nasal valve region is valuable for the assessment of functional rhinoplasty surgical outcomes. Anatomical optical coherence tomography (aOCT) is an imaging modality that may be used to obtain real-time, quantitative, and volumetric scans of the nasal airway. We aim to evaluate if volumetric aOCT imaging is useful for the examination of the nasal valve region before and after functional rhinoplasty procedures. aOCT scans of the nasal valves were performed on four cadaveric heads before and after spreader graft and butterfly graft procedures. The resulting aOCT images were compared against video endoscopy images, and the segmented volumes of the nasal airway obtained from aOCT scans were compared with computed tomography (CT) derived volumes acquired under the same conditions. The aOCT-derived volumes match the CT volumes closely, with a mean Dice similarity coefficient of 0.88 and a mean Hausdorff distance of 2.3 mm. Furthermore, the aOCT images were found to represent the shape of the nasal cavity accurately. Due to its ability to perform real-time, quantitative, and accurate evaluation of the nasal airway, aOCT imaging is a promising modality for the objective assessment of the nasal valves before and after functional rhinoplasty procedures.


Assuntos
Cavidade Nasal/anatomia & histologia , Cavidade Nasal/cirurgia , Cirurgia Endoscópica por Orifício Natural/métodos , Rinoplastia/métodos , Tomografia de Coerência Óptica/métodos , Humanos , Cavidade Nasal/diagnóstico por imagem , Retalhos Cirúrgicos , Tomografia Computadorizada por Raios X