Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Fr Ophtalmol ; 47(9): 104098, 2024 Aug 28.
Artigo em Francês | MEDLINE | ID: mdl-39208602

RESUMO

The surgical treatment of glaucoma has been and is still based on filtering surgeries, commonly used for about half a century. The safety and efficacy of these techniques have been well described, as it has also been done for cyclophotocoagulation and valves or tubes, indicated in France mostly for refractory glaucoma. Minimally invasive glaucoma surgeries have emerged in recent decades, increasing the number of therapeutic options, and allowing treatment decisions to be as patient-centered as possible. Most of these techniques have now been studied for more than five years. Since glaucoma is a chronic, progressive optic neuropathy, the sustainability of each surgery's results is essential. The amount of available data concerning long-term efficacy and safety of glaucoma surgeries is increasing, so we have decided to describe it through this review of the literature.

2.
J Fr Ophtalmol ; 47(8): 104260, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39067375

RESUMO

PURPOSE: The goal of this study was to assess the efficacy and safety of inferior implantation of the Xen Gel 45® Stent in a cohort of refractory glaucoma patients who had undergone multiple failed procedures and lacked healthy superior conjunctiva. PATIENTS AND METHODS: We retrospectively included individuals with refractory glaucoma who underwent implantation of a Xen 45® in the inferior quadrants of the conjunctiva. At the 12-month mark, two success criteria were assessed: "Complete" success, defined as an intraocular pressure (IOP)≤21mmHg with a≥20% reduction in IOP without additional IOP-lowering medications, the absence of a requirement for additional filtering surgery, and the absence of chronic hypotony; and "Qualified" success, which consisted of patients meeting the same criteria but requiring glaucoma medications postoperatively. Safety was also monitored throughout the 12-month follow-up. RESULTS: A total of 35 patients who underwent inferior Xen implantation were assessed. After 12months, 20 patients (57.1%) achieved qualified success, with twelve patients (34.3%) attaining complete success. Excluding five patients who underwent additional filtering surgery during follow-up, the mean IOP decreased significantly from 30.73±9.7mmHg to 16.49±7.9mmHg, representing a mean decrease of 14.24±12.13mmHg (46.5%; P<0.0001). The mean number of medications at 12months decreased from 3.43±1.6 to 1.53±1.52 (-55.4%; P<0.0001). The mean number of needlings was 1.29±1.2. Implant exposure was observed in two patients during the first postoperative month. CONCLUSIONS: Inferior placement of Xen appears to be a viable treatment option for patients with refractory glaucoma and a history of multiple failed glaucoma procedures. It demonstrates both significant efficacy and acceptable safety.

3.
J Fr Ophtalmol ; 46(3): 287-299, 2023 Mar.
Artigo em Francês | MEDLINE | ID: mdl-36759249

RESUMO

The corneal epithelium is one of the first tissue barriers of the eye against the environment. In recent years, many studies provided better knowledge of its healing, its behavior and its essential role in the optical system of the eye. At the crossroads of basic science and clinical medicine, the study of the mechanical stresses applied to the cornea makes it possible to learn the behavior of epithelial cells and better understand ocular surface disease. We describe herein the current knowledge about the adhesion systems of the corneal epithelium and their resistance to mechanical stress. We will also describe the involvement of these mechanisms in corneal healing and their role in epithelial dynamics. Adhesion molecules of the epithelial cells, especially hemidesmosomes, allow the tissue cohesion required to maintain the integrity of the corneal epithelium against the shearing forces of the eyelids as well as external forces. Their regeneration after a corneal injury is mandatory for the restoration of a healthy epithelium. Mechanotransduction plays a significant role in regulating epithelial cell behavior, and the study of the epithelium's response to mechanical forces helps to better understand the evolution of epithelial profiles after refractive surgery. A better understanding of corneal epithelial biomechanics could also help improve future therapies, particularly in the field of tissue engineering.


Assuntos
Lesões da Córnea , Epitélio Corneano , Humanos , Fenômenos Biomecânicos , Mecanotransdução Celular , Córnea/fisiologia , Epitélio Corneano/fisiologia , Cicatrização/fisiologia , Lesões da Córnea/terapia
4.
J Fr Ophtalmol ; 43(8): 779-793, 2020 Oct.
Artigo em Francês | MEDLINE | ID: mdl-32807552

RESUMO

Glaucoma is a blinding optic neuropathy, the main risk factor for which is increased intraocular pressure (IOP). The trabecular meshwork, located within the iridocorneal angle, is the main pathway for drainage of aqueous humor (AH) out of the eye, and its dysfunction is responsible for the IOP elevation. The trabecular meshwork is a complex, fenestrated, three-dimensional structure composed of trabecular meshwork cells (TMC) interdigitated into a multilayered organization within the extracellular matrix (ECM). The purpose of this literature review is to provide an overview of current understanding of the trabecular meshwork and its pathophysiology in glaucoma. Thus, we will present the main anatomical and cellular bases for the regulation of aqueous humor outflow resistance, the pathophysiological mechanisms involved in trabecular dysfunction in the various types of glaucoma, as well as current and future therapeutic strategies targeting the trabecular meshwork.


Assuntos
Glaucoma/etiologia , Malha Trabecular/química , Malha Trabecular/fisiologia , Glaucoma/patologia , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Doenças do Nervo Óptico/patologia , Doenças do Nervo Óptico/fisiopatologia , Malha Trabecular/citologia , Malha Trabecular/patologia
5.
J Fr Ophtalmol ; 43(7): e217-e230, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32561029

RESUMO

Glaucoma is a blinding optic neuropathy, the main risk factor for which is increased intraocular pressure (IOP). The trabecular meshwork, located within the iridocorneal angle, is the main pathway for drainage of aqueous humor (AH) out of the eye, and its dysfunction is responsible for the IOP elevation. The trabecular meshwork is a complex, fenestrated, three-dimensional structure composed of trabecular meshwork cells (TMC) interdigitated into a multilayered organization within the extracellular matrix (ECM). The purpose of this literature review is to provide an overview of current understanding of the trabecular meshwork and its pathophysiology in glaucoma. Thus, we will present the main anatomical and cellular bases for the regulation of aqueous humor outflow resistance, the pathophysiological mechanisms involved in trabecular dysfunction in the various types of glaucoma, as well as current and future therapeutic strategies targeting the trabecular meshwork.


Assuntos
Glaucoma/etiologia , Malha Trabecular/química , Malha Trabecular/fisiologia , Humor Aquoso/química , Humor Aquoso/fisiologia , Glaucoma/classificação , Glaucoma/fisiopatologia , Glaucoma/cirurgia , Humanos , Pressão Intraocular/fisiologia , Doenças do Nervo Óptico/patologia , Doenças do Nervo Óptico/fisiopatologia , Doenças do Nervo Óptico/cirurgia , Malha Trabecular/patologia , Malha Trabecular/cirurgia , Trabeculectomia/métodos
6.
J Fr Ophtalmol ; 42(4): 391-403, 2019 Apr.
Artigo em Francês | MEDLINE | ID: mdl-30879831

RESUMO

PURPOSE: The purpose of this study was to analyze the change in intraocular pressure (IOP) and glaucoma medications using the XEN® Gel Stent as a solo procedure or in association with phacoemulsification in patients with chronic open angle glaucoma (OAG). METHODS: We included cohort studies with at least one year of follow-up in patients with primary open angle glaucoma (POAG), pseudo-exfoliative glaucoma (PXG) or pigmentary glaucoma (PG) who received a XEN® gel stent. The main outcome measure was IOP reduction at 12 months follow-up. Secondary outcomes were the decrease in glaucoma medications 12 months after surgery, frequency and type of postoperative interventions and complication rate. RESULTS: A total of 8 case series published between 2016 and 2018 were included; six were prospective studies, and two were retrospective. There was no randomized controlled trial. The data concerned a total of 958 eyes of 777 patients. The various studies showed a mean IOP at 12 months between 13 and 16mmHg, which represented an IOP reduction between 25 and 56% (mean: 42%). This decrease was associated with a reduction in glaucoma medications in all studies. The decrease in IOP was significantly greater in XEN® implantation as a stand-alone procedure (44%) than in combined surgery (32%) (P<0.05). Transient hypotony (<1 month) (3%), choroidal detachment or choroidal folds (1.5%), hyphema (1.9%), bleb leak (1.1%) and shallow anterior chamber (1.1%) were the most frequent complications. As for severe complications, four cases of malignant glaucoma (0.4%) and one case of retinal detachment have been reported. In the follow-up period, needling has been required in 32% of cases, and a total of 55 eyes (5.7%) required repeat filtering surgery or cyclodestructive procedure. CONCLUSION: XEN® Gel Stent appears effective for reducing IOP and the number of medications in OAG patients within 1 year postoperatively with an acceptable safety profile. However, vigilant postoperative follow-up and frequent postoperative maneuvers are required.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Stents , Doença Crônica , Terapia Combinada , Cirurgia Filtrante/métodos , Humanos , Pressão Intraocular/fisiologia , Facoemulsificação/métodos , Desenho de Prótese , Tonometria Ocular , Resultado do Tratamento
7.
J Fr Ophtalmol ; 42(2): e37-e46, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30683533

RESUMO

PURPOSE: The purpose of this study was to analyze the change in intraocular pressure (IOP) and glaucoma medications using the XEN® Gel Stent as a solo procedure or in association with phacoemulsification in patients with chronic open angle glaucoma (OAG). METHODS: We included cohort studies with at least one year of follow-up in patients with primary open angle glaucoma (POAG), pseudo-exfoliative glaucoma (PXG) or pigmentary glaucoma (PG) who received a XEN® gel stent. The main outcome measure was IOP reduction at 12 months follow-up. Secondary outcomes were the decrease in glaucoma medications 12 months after surgery, frequency and type of postoperative interventions and complication rate. RESULTS: A total of 8 case series published between 2016 and 2018 were included; six were prospective studies, and two were retrospective. There was no randomized controlled trial. The data concerned a total of 958 eyes of 777 patients. The various studies showed a mean IOP at 12 months between 13 and 16mmHg, which represented an IOP reduction between 25 and 56% (mean: 42%). This decrease was associated with a reduction in glaucoma medications in all studies. The decrease in IOP was significantly greater in XEN® implantation as a stand-alone procedure (44%) than in combined surgery (32%) (P<0.05). Transient hypotony (< 1 month) (3%), choroidal detachment or choroidal folds (1.5%), hyphema (1.9%), bleb leak (1.1%) and shallow anterior chamber (1.1%) were the most frequent complications. As for severe complications, four cases of malignant glaucoma (0.4%) and one case of retinal detachment have been reported. In the follow-up period, needling has been required in 32% of cases, and a total of 55 eyes (5.7%) required repeat filtering surgery or cyclodestructive procedure. CONCLUSION: XEN® Gel Stent appears effective for reducing IOP and the number of medications in OAG patients within 1 year postoperatively with an acceptable safety profile. However, vigilant postoperative follow-up and frequent postoperative maneuvers are required.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/terapia , Stents , Doença Crônica , Estudos de Coortes , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma de Ângulo Aberto/patologia , Humanos , Facoemulsificação , Desenho de Prótese , Stents/efeitos adversos , Resultado do Tratamento
8.
J Fr Ophtalmol ; 40(9): e315-e321, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28987446

RESUMO

PURPOSE: Pigment dispersion syndrome (PDS) is characterized by a structural abnormality of the posterior surface of the iris causing contact with the zonular fibers. It can lead to an open-angle glaucoma secondary to pigment dispersion into the trabecular meshwork. Laser peripheral iridotomy (PI) has been proposed as a treatment for pigmentary glaucoma (PG) and pigment dispersion syndrome (PDS) by reducing the dispersion of pigment. The goal of this review was to assess the effects of PI for PDS and PG. METHODS: We included six randomized controlled trials and two cohort studies (286 eyes of 218 participants). Four trials included participants with PG, and 4 trials enrolled participants with PDS with or without elevated intraocular pressure (IOP). RESULTS: Among patients with PG, at an average of 9 months of follow-up, the mean difference in IOP between groups was 2.69mm Hg less in the PI group (95% CI: -6.05 to 0.67; 14 eyes). In patients with PDS, the average IOP was statistically lower after PI as compared to baseline (Student test t=11.49, P<0.01, 38 eyes). With regard to visual field progression in participants with PG, after an average follow-up of 28 months, the risk of progression was not influenced by PI (RR 1.00 95% CI: 0.16 to 6.25; 32 eyes). No trials that enrolled patients with PDS showed a diminution of the risk of glaucoma conversion at mid- and long-terms. CONCLUSION: PI decreases the biomechanical factor causing contact between the iris and zonular fibers and may lower IOP over the long-term. Nevertheless, the effects of PI on visual field changes or progression have not been established in PG and PDS. There is no scientific evidence as of yet to advocate PI as a treatment for PDS or PG.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Terapia a Laser/métodos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Estudos de Coortes , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
9.
J Fr Ophtalmol ; 40(10): 889-897, 2017 Dec.
Artigo em Francês | MEDLINE | ID: mdl-29050926

RESUMO

PURPOSE: Pigment dispersion syndrome (PSD) is characterized by a structural abnormality of the posterior surface of the iris causing contact with the zonular fibers. It can lead to an open-angle glaucoma secondary to pigment dispersion into the trabecular meshwork. Laser peripheral iridotomy (PI) has been proposed as a treatment for pigmentary glaucoma (PG) and pigment dispersion syndrome (PDS) by reducing the dispersion of pigment. The goal of this review was to assess the effects of PI for PSD and PG. METHODS: We included six randomized controlled trials and two cohort studies (286 eyes of 218 participants). Four trials included participants with PG, and 4 trials enrolled participants with PSD with or without elevated intraocular pressure (IOP). RESULTS: Among patients with PG, at an average of 9 months of follow-up, the mean difference in IOP between groups was 2.69mmHg less in the PI group (95 % CI: -6.05 to 0.67; 14 eyes). In patients with PDS, the average IOP was statistically lower after PI as compared to baseline (Student test, t=11.49, P<0.01). With regard to visual field progression in participants with GP, after an average follow-up of 28 months, the risk of progression was not influenced by PI (RR 1.00 95 %: CI 0.16 to 6.25; 32 eyes). No trials that enrolled patients with PSD showed a diminution of the risk of glaucoma conversion at mid- and long-term. CONCLUSION: PI decreases the biomechanical factor causing contact between the iris and zonular fibers and may lower IOP over the long-term. Nevertheless, the effects of PI on visual field changes or progression have not been established in PG and PDS. There is no scientific evidence as of yet to advocate PI as a treatment for PDS or PG.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Iris/cirurgia , Terapia a Laser/métodos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Síndrome de Exfoliação/complicações , Síndrome de Exfoliação/epidemiologia , Síndrome de Exfoliação/cirurgia , Glaucoma de Ângulo Aberto/epidemiologia , Humanos , Terapia a Laser/efeitos adversos , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA