Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Intern Emerg Med ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353879

RESUMO

D-dimer levels significantly increase with declining renal function and hence, renal function-adjusted D-dimer cutoffs to rule out pulmonary embolism were suggested. Aim of this study was to "post hoc" validate previously defined renal function-adjusted D-dimer levels to safely rule out pulmonary embolism in patients presenting to the emergency department. In this retrospective, observational analysis, all patients with low to intermediate pre-test probability receiving D-dimer measurement and computed tomography angiography (CTA) to rule out pulmonary embolism between January 2017 and December 2020 were included. Previously defined renal function-adjusted D-dimer cutoffs (1306 µg/l for moderate and 1663 µg/l for severe renal function impairment) were applied to determine sensitivity, specificity, negative and positive predictive values. One thousand, three hundred sixty-nine patients were included of which 229 (17%) were diagnosed with pulmonary embolism. The estimated glomerular filtration rate (eGFR) was ≥ 60 ml/min in 1079 (79%), 30-59 ml/min in 266 (19%) and < 30 ml/min in 24 (2%) patients. Only three patients (1.1%) with an eGFR < 60 ml/min had a D-dimer level < 500 µg/l. There was a significant correlation between D-dimer and eGFR (R = - 0.159, p < 0.001). Calculated on the standard D-dimer cutoff value of 500 µg/l, sensitivity of D-dimer testing was 97% for patients with an eGFR ≥ 60 ml/min and 100% for those with 30-60 ml/min, while specificity decreased in patients with renal function impairment. A negative predictive value of 0.99 as a premise to safely rule out pulmonary embolism was achieved by applying a D-dimer cutoff of 1480 µg/l for eGFR 30-59 ml/min and 1351 µg/l for eGFR < 30 ml/min. The findings of this study underline that application of renal function-adapted D-dimer levels in combination with a clinical prediction rule appears feasible to rule out pulmonary embolism. Out of the current dataset, renal function-adjusted D-dimer cutoffs to rule out pulmonary embolism were slightly different compared to previously defined cutoffs. Further studies on a larger scale are needed to validate possible renal function-adjusted D-dimer cutoffs.

2.
Am J Sports Med ; 52(2): 441-450, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38259113

RESUMO

BACKGROUND: Arthroscopic rotator cuff repair (ARCR) is among the most commonly performed orthopaedic procedures. Several factors-including age, sex, and tear severity-have been identified as predictors for outcome after repair. The influence of the tear etiology on functional and structural outcome remains controversial. PURPOSE: To investigate the influence of tear etiology (degenerative vs traumatic) on functional and structural outcomes in patients with supraspinatus tendon tears. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: Patients undergoing ARCR from 19 centers were prospectively enrolled between June 2020 and November 2021. Full-thickness, nonmassive tears involving the supraspinatus tendon were included. Tears were classified as degenerative (chronic shoulder pain, no history of trauma) or traumatic (acute, traumatic onset, no previous shoulder pain). Range of motion, strength, the Subjective Shoulder Value, the Oxford Shoulder Score (OSS), and the Constant-Murley Score (CMS) were assessed before (baseline) and 6 and 12 months after ARCR. The Subjective Shoulder Value and the OSS were also determined at the 24-month follow-up. Repair integrity after 12 months was documented, as well as additional surgeries up to the 24-month follow-up. Tear groups were compared using mixed models adjusted for potential confounding effects. RESULTS: From a cohort of 973 consecutive patients, 421 patients (degenerative tear, n = 230; traumatic tear, n = 191) met the inclusion criteria. The traumatic tear group had lower mean baseline OSS and CMS scores but significantly greater score changes 12 months after ARCR (OSS, 18 [SD, 8]; CMS, 34 [SD,18] vs degenerative: OSS, 15 [SD, 8]; CMS, 22 [SD, 15]) (P < .001) and significantly higher 12-month overall scores (OSS, 44 [SD, 5]; CMS, 79 [SD, 9] vs degenerative: OSS, 42 [SD, 7]; CMS, 76 [SD, 12]) (P≤ .006). At the 24-month follow-up, neither the OSS (degenerative, 44 [SD, 6]; traumatic, 45 [SD, 6]; P = .346) nor the rates of repair failure (degenerative, 14 [6.1%]; traumatic 12 [6.3%]; P = .934) and additional surgeries (7 [3%]; 7 [3.7%]; P = .723) differed between groups. CONCLUSION: Patients with degenerative and traumatic full-thickness supraspinatus tendon tears who had ARCR show satisfactory short-term functional results. Although patients with traumatic tears have lower baseline functional scores, they rehabilitate over time and show comparable clinical results 1 year after ARCR. Similarly, degenerative and traumatic rotator cuff tears show comparable structural outcomes, which suggests that degenerated tendons retain healing potential.


Assuntos
Lacerações , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Estudos de Coortes , Dor de Ombro/diagnóstico por imagem , Dor de Ombro/etiologia , Dor de Ombro/cirurgia , Resultado do Tratamento , Ruptura/cirurgia , Artroscopia/métodos , Amplitude de Movimento Articular , Estudos Retrospectivos , Imageamento por Ressonância Magnética
3.
J Craniomaxillofac Surg ; 49(7): 598-612, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34020871

RESUMO

OBJECTIVE: This retrospective study evaluates the occurrence and frequency of different fracture patterns in a series of computed tomography (CT) scans in terms of the AOCMF Trauma Classification (TC) orbit module and correlates the assigned defects with measurements of the fracture area in order to get an approximate guideline for fracture size predictions on the basis of the classification. MATERIAL AND METHODS: CT scans of patients with orbital floor fractures were evaluated using the AOCMFTC to determine the topographical subregions. The coding consisted of: W = orbital wall, 1 = anterior orbit, 2 = midorbit, i = inferior, m = medial. The 3-dimensional surface area size of the fractures was quantified by the "defect body" method (Brainlab, Munich, Germany). The fracture area size and its confidence and prediction interval within each topographical subregion was estimated by regression analysis. RESULTS: A total of 137 CT scans exhibited 145 orbital floor fractures, which were combined with 34 medial orbital wall fractures in 31 patients. The floor fractures - W1(i)2(i) (n = 86) and W1(i) (n = 19) were the most frequent patterns. Combined floor and medial wall fractures most frequently corresponded to the pattern W1 (im)2 (im) (n = 15) ahead of W1 (im) 2(i) (n = 10). The surface area size ranged from 0.11 cm2 to 6.09 cm2 for orbital floor and from 0.29 cm2 to 5.43 cm2 for medial wall fractures. The prediction values of the mean fracture area size within the subregions were computed as follows: W1(i) = 2.25 cm2, W2(i) = 1.64 cm2, W1(i)2(i) = 3.10 cm2, W1(m) = 1.36 cm2, W2(m) = 1.65 cm2, W1(m)2(m) = 2.98 cm2, W1 (im) = 3.35 cm2, W1 (im) 2(i) = 4.63 cm2, W1 (im)2(m) = 4.06 cm2 and W1 (im)2 (im) = 7.16 cm2. CONCLUSION: The AOCMFTC orbital module offers a suitable framework for topographical allocation of fracture patterns inside the infero-medial orbital cavity. The involvement of the subregions is of predictive value providing estimations of the mean 3-D fracture area size.


Assuntos
Órbita , Fraturas Orbitárias , Alemanha , Humanos , Órbita/diagnóstico por imagem , Fraturas Orbitárias/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
4.
Eur J Dent ; 12(3): 443-445, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30147414

RESUMO

Patients with plasma cell myeloma may initially present to their dentists or dental surgeons with toothache, loose teeth, or gingival masses. An X-ray of the jaw can reveal osteolyses. In addition, accumulation of monoclonal light chains in AL-amyloidosis can lead to macroglossia. It is prudent that the dentist or dental surgeon recognizes the underlying disease and refers the patient to the oncologist or hematologist for further workup to prevent the complications of plasma cell myeloma such as renal impairment, fractures, bone pain, infections, hypercalcemia, anemia, or heart failure. Another area where the dentist or dental surgeon is involved with patients suffering from plasma cell myeloma is prevention and therapy of osteonecrosis of the jaw, occurring after administration of bisphosphonates or denosumab for osteolytic bone disease. The case report presented here shows a patient complaining of toothache for whom recognition of a systemic disease by the dentist led to the diagnosis of plasma cell myeloma, highlighting the need for interdisciplinary cooperation. As recent years have seen many changes in the management of patients with plasma cell myeloma, an update for dentists and dental surgeons is warranted.

5.
J Shoulder Elbow Surg ; 24(12): 1894-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26163283

RESUMO

BACKGROUND: In wheelchair-dependent individuals, pain often develops because of rotator cuff tendon failure and/or osteoarthritis of the glenohumeral joint. The purposes of this study were to investigate (1) specific rotator cuff tear patterns, (2) structural healing, and (3) clinical outcomes after arthroscopic rotator cuff repair in a cohort of wheelchair-dependent patients. METHODS: Forty-six shoulders with a mean follow-up of 46 months (range, 24-82 months; SD, 13 months) from a consecutive series of 61 shoulders in 56 patients (46 men and 10 women) undergoing arthroscopic rotator cuff repair were available for analysis. Clinical outcome analysis was performed using the Constant-Murley score, the Subjective Shoulder Value, and the American Shoulder and Elbow Surgeons score. The integrity of the repair was analyzed by ultrasound. RESULTS: Of the shoulders, 87% had supraspinatus involvement, 70% had subscapularis involvement, and 57% had an anterosuperior lesion involving both the supraspinatus and subscapularis. Despite an overall structural failure rate of 33%, the patients showed improvements in the Constant-Murley score from 50 points (range, 22-86 points; SD, 16 points) preoperatively to 80 points (range, 40-98 points; SD, 12 points) postoperatively and in the American Shoulder and Elbow Surgeons score from 56 points (range, 20-92 points; SD, 20 points) preoperatively to 92 points (range, 53-100 points; SD, 10 points) postoperatively, with a mean postoperative Subjective Shoulder Value of 84% (range, 25%-100%; SD, 17%). CONCLUSION: Failure of the rotator cuff in weight-bearing shoulders occurs primarily anterosuperiorly. Arthroscopic rotator cuff repair leads to a structural failure rate of 33% but satisfactory functional results with high patient satisfaction at midterm follow-up.


Assuntos
Artroscopia/métodos , Manguito Rotador/cirurgia , Ombro/fisiopatologia , Traumatismos dos Tendões/cirurgia , Suporte de Carga , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Lesões do Manguito Rotador , Ombro/cirurgia , Lesões do Ombro , Traumatismos dos Tendões/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
6.
J Plast Surg Hand Surg ; 49(2): 95-101, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24909821

RESUMO

The free fibula osteoseptocutaneous flap is the standard for reconstruction of extensive mandibular defects. The procedure must be precise to achieve the required functional and aesthetic results. The aim of the present study was to calculate retrospectively the exact differences in surgical outcome based on preoperative and postoperative Computed Tomography data sets. Ten patients with unilateral reconstructions of the mandible with a fibula based on conventional planning were analyzed quantitatively, applying mirroring techniques with direct comparison of the theoretically optimum with the actual reconstruction. The results showed that there is a significant discrepancy between what is actually achieved and the theoretical optimum. The result of the present retrospective analysis shows that there is room for further improvement of the outcome in complex mandible reconstruction cases.


Assuntos
Transplante Ósseo/métodos , Carcinoma de Células Escamosas/cirurgia , Fíbula/transplante , Mandíbula/cirurgia , Neoplasias Mandibulares/cirurgia , Cirurgia Assistida por Computador , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica , Estudos Retrospectivos , Retalhos Cirúrgicos/irrigação sanguínea , Tomografia Computadorizada por Raios X
7.
Clin Implant Dent Relat Res ; 16(4): 540-51, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23167722

RESUMO

PURPOSE: The aim of the present study was to evaluate deviations between virtually planned and placed implants by the use of skeletally supported stereolithographic templates. MATERIALS AND METHODS: Ten consecutive patients were selected for virtual three-dimensional implant planning using the Facilitate(TM) software (Astra Tech AB, Mölndal, Sweden). Computer tomography images were obtained in the pre- and postoperative phase. Four deviation parameters (i.e. global, angular, depth, and lateral deviation) were defined and calculated between the planned and the placed implants, using the coordinates of their respective apical and coronal points. RESULTS: Deviations at the coronal positions appeared to be smaller (95% confidence interval: 0.15-1.0) as compared with apical positions (95% confidence interval: 0.14-1.1). But only the difference with regard to lateral measurements appeared to be statistically significant (p = .03). Except for depth (p = .01), no significant association between mesial or more distal locations could be detected concerning global (p = .07), lateral (p = .87), and angular (p = .56) values in mixed model analyses. Overall, there was a slight tendency for higher values for more distal locations. CONCLUSION: As slight deviations between planned and placed implants especially may occur even with skeletal-supported templates, the clinician should be aware not to overestimate advocated surgical safety by using static navigation tools.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Precisão da Medição Dimensional , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Software
8.
Curr Opin Otolaryngol Head Neck Surg ; 20(6): 443-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23086262

RESUMO

PURPOSE OF REVIEW: Multidetector computed tomography (MDCT) is the examination of choice for laryngeal imaging in benign and malignant lesions. This review gives an overview of the MDCT scanning technique and discusses the advantages and disadvantages in investigation of benign lesions of the larynx. RECENT FINDINGS: MDCT is not the primary diagnostic method for benign lesions on the vocal folds. However, CT is indispensable for the diagnostic investigation of immobility of the vocal fold, for laryngoceles, and for laryngeal trauma, and may allow the exact delineation of extension and nature of benign laryngeal disease. The improved spatial resolution with consecutive high-quality two-dimensional (2D) and three-dimensional (3D) reconstructions using thin-slice MDCT allows a better detection of laryngeal anatomic structures and benign pathologies. SUMMARY: The investigation of choice in diagnosing the cause of hoarseness is laryngoscopy and/or laryngostroboscopy, respectively. Nevertheless, thin-slice MDCT with multiplanar 2D and 3D volume-rendered reconstructions is essential for exact anatomic definition and extension and diagnosis of subtle benign laryngeal diseases.


Assuntos
Doenças da Laringe/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Humanos , Laringocele/diagnóstico por imagem , Laringe/lesões , Tomografia Computadorizada Multidetectores/métodos , Ultrassonografia , Prega Vocal/diagnóstico por imagem
9.
J Craniomaxillofac Surg ; 37(6): 305-11, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19264499

RESUMO

PURPOSE: A comprehensive classification based on high resolution computed tomography (CT) of the whole craniofacial region was correlated with clinical findings of combined skull base and maxillofacial fractures. MATERIAL AND METHODS: In a study of two clinical centres, 70 patients with such injuries were admitted at the Universities of Basel (n=29) and Uppsala (n=41). Clinical signs (rhinorrhoea, periorbital haematoma and pneumencephalus) and surgical versus conservative treatment were correlated with a cranio-maxillofacial injury severity score (CMF-ISS) calculated from the classification system. Fracture classifications were decided in consensus on the basis of CT and semiautomatic classification software. The classification system defined 3 fracture types (A, B, C), 3 groups (A1, A2, A3), and 3 subgroups (A1.1, A1.2, A1.3) with increasing severity from A1.1 (lowest) to C3.3 (highest). RESULTS: Of 70 patients, 43 were operated upon and 27 conservatively treated. The operated patients had significantly higher severity scores than non-operated. Patients with or without periorbital haematoma do not differ significantly in the severity score. The severity of the CMF-ISS score was significantly associated (two sample T-test P<0.01) with the occurrence of pneumencephalus, rhinorrhoea and treatment approach. CONCLUSION: Based on our present results, this system seems to be clinical useful for operative decisions and interventions.


Assuntos
Fixação de Fratura/métodos , Traumatismos Maxilofaciais/classificação , Base do Crânio/lesões , Fraturas Cranianas/classificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Rinorreia de Líquido Cefalorraquidiano/patologia , Criança , Pré-Escolar , Feminino , Hematoma/patologia , Humanos , Escala de Gravidade do Ferimento , Modelos Logísticos , Masculino , Traumatismos Maxilofaciais/diagnóstico por imagem , Traumatismos Maxilofaciais/cirurgia , Pessoa de Meia-Idade , Doenças Orbitárias/patologia , Pneumocefalia/patologia , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Base do Crânio/cirurgia , Fraturas Cranianas/diagnóstico por imagem , Fraturas Cranianas/cirurgia , Software , Tomografia Computadorizada por Raios X , Adulto Jovem
10.
Eur J Nucl Med Mol Imaging ; 34(9): 1388-95, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17265035

RESUMO

PURPOSE: Substance P is the main ligand of neurokinin type 1 (NK-1) receptors, which are consistently overexpressed in malignant gliomas. The peptidic vector 111In/90Y-DOTAGA-substance P binds to these receptors and can be used for local treatment of brain tumours. Dosimetry for this interstitial brachytherapy has mainly been done using geometrical models; however, they often do not faithfully reproduce the in vivo biodistribution of radiopharmaceuticals, which is indispensable to correlate the deposited energy with clinical response. The aim of this study was to establish a reproducible dosimetry protocol for intratumoural radiopeptide therapy. METHODS: For test and therapeutic injections, 2 MBq of 111In-substance P and 370-3,330 MBq of 90Y-substance P, respectively, were applied in 12 patients with malignant gliomas. Over a period of 24 h, serial SPECT scans were performed on a dual-head SPECT camera. The scans were acquired in a double-energy window technique together with 99mTc-ECD in order to co-register the dose distributions with a separately acquired, contrast-enhanced CT scan. Quantitative voxelwise dose distribution maps (in Gy/GBq) were computed from these data using a mono-exponential decay approach. Pre- and post-therapeutic values were compared. RESULTS: Agreement between pre- and post-therapeutic dosimetry was very good and delivered absolute dose values in Gy per injected GBq. In all patients, the pretherapeutic test injection together with the CT overlay technique could predict the precise localisation of dose deposition in an anatomical context. CONCLUSION: This protocol allows a precise pretherapeutic computation of the expected three-dimensional dose distribution and is clearly superior to the previously used dosimetry based on planar scintigraphic images. It has become an indispensable tool for planning intratumoural radiopeptide therapy in glioma patients.


Assuntos
Neoplasias Encefálicas/radioterapia , Glioma/radioterapia , Radiometria/métodos , Substância P/química , Radioisótopos de Ítrio , Adulto , Idoso , Antígenos de Neoplasias/metabolismo , Encéfalo/patologia , Neoplasias Encefálicas/patologia , Moléculas de Adesão Celular/metabolismo , Molécula de Adesão da Célula Epitelial , Feminino , Glioma/patologia , Humanos , Ligantes , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Modelos Teóricos , Radioterapia/métodos , Análise de Regressão , Tomografia Computadorizada por Raios X
11.
Eur Arch Otorhinolaryngol ; 263(1): 69-74, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15971032

RESUMO

We present a case study of a 49-year-old patient with an 8-year history of hypersensitivity to sound produced by intrinsic but not extrinsic sources. Findings that indicated an organic problem were: a supranormal bone conduction threshold of -25 to -15 dB HL from 0.25 to 1 kHz with an air-bone gap of 15 to 45 dB HL, a lower threshold and larger amplitude for vestibular-evoked myogenic potentials, eye movement reactions to sound and trunk pitch sway in response to sound. Results of immitance audiometry and otoacoustic emission testing were within normal limits and indicative of intact middle ear conductance. A high-resolution CT scan of the temporal bone demonstrated a dehiscence of bone overlying the superior semicircular canal. These findings support previous research indicating that auditory energy reaches the cochleo-vestibular receptor systems more easily via transmission through cerebrospinal fluid than through bone. Therefore, a dehiscence of the bone overlying the superior semicircular canal may lead to hypersensitivity to intrinsic sound. We recommend that similar findings in other patients be followed up with an evaluation of middle ear function and the temporal bone with high-resolution CT scan.


Assuntos
Hiperacusia/etiologia , Canais Semicirculares/patologia , Osso Temporal/patologia , Condução Óssea , Humanos , Hiperacusia/patologia , Doenças do Labirinto/patologia , Doenças do Labirinto/fisiopatologia , Masculino , Pessoa de Meia-Idade
12.
J Endovasc Ther ; 10(1): 141-6, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12751946

RESUMO

PURPOSE: To report stent implantation for a malignant obstruction within the pulmonary artery (PA) caused by a recurrent leiomyosarcoma in the pulmonary trunk. CASE REPORT: A 62-year-old man with a non-metastatic primary leiomyosarcoma of the right PA underwent pneumectomy of the right lung and postoperative radiotherapy in 1994. Six years later, he presented with symptoms of progressive right ventricular dysfunction. Computed tomography (CT) identified a high-grade stenosis of the left PA due to recurrent tumor within the pulmonary trunk extending into the left PA. Transthoracic ultrasound documented severe pulmonary hypertension with a high pressure gradient across the stenosis. A stent was deployed percutaneously, successfully establishing PA patency. Pressure measurements showed a significantly reduced gradient across the stented area. In follow-up, the patient reported subjective improvement of symptoms; CT scans revealed a fully patent stent. His status remained stable 11 months after stent implantation. CONCLUSIONS: PA leiomyosarcoma is a rare and highly malignant tumor. In most cases, surgery can only prolong survival for the short term. Palliative interventional PA stenting performed under local anesthesia can offer improvement in quality of life by reducing excessive pulmonary hypertension.


Assuntos
Leiomiossarcoma/complicações , Artéria Pulmonar/patologia , Artéria Pulmonar/cirurgia , Stents , Neoplasias Vasculares/complicações , Constrição Patológica , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA