1.
Magn Reson Med ; 71(5): 1670-5, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23798380

RESUMO

PURPOSE: The aims of this study were (i) to establish a robust and fast method to quantify hepatocellular phosphorus compounds in molar concentration on a 3T clinical scanner, (ii) to evaluate its reproducibility, and (iii) to test its feasibility for a use in large cohort studies. METHOD: Proton-decoupled (31) P magnetic resonance spectroscopy of liver (31) P compounds were acquired on 85 healthy subjects employing image selected in-vivo spectroscopy localization in 13 min of acquisition at 3T. Absolute quantification was achieved using an external reference and double-matching phantoms (inorganic phosphates and adenosine triphosphate (ATP) solutions). Reproducibility of the method was also examined. RESULTS: This method showed a high intra- and interday as well as inter- and intraobserver reproducibility (r > 0.98; P < 0.001), with a high signal to noise ratio (SNR) (i.e., mean SNR of γ-ATP: 16). The mean liver concentrations of 85 healthy subjects were assessed to be 1.99 ± 0.51 and 2.74 ± 0.55 mmol/l of wet tissue volume for Pi and γ-ATP, respectively. CONCLUSION: This method reliably quantified molar concentrations of liver (31) P compounds on 85 subjects with a short total examination time (∼25 min) on a 3T clinical scanner. Thus, the current method can be readily utilized for a clinical study, such as a large cohort study.


Assuntos
Fígado/metabolismo , Fosfatos/metabolismo , Espectroscopia de Prótons por Ressonância Magnética/instrumentação , Espectroscopia de Prótons por Ressonância Magnética/métodos , Estudos de Coortes , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Isótopos de Fósforo/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Invest Radiol ; 48(6): 477-84, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23462676

RESUMO

OBJECTIVES: The aims of our study were (1) to assess the feasibility, effectiveness, and safety of exclusively magnetic resonance (MR)-guided freehand percutaneous abscesses drainage using a 1.0-T open MR scanner and (2) to evaluate the optimal method to visualize drainage catheters in situ. MATERIAL AND METHODS: In vitro studies in a dedicated MR gelatin phantom were performed to assess visualization of 8 different sizes of drainage catheters after instillation of sole 0.9% sodium chloride (NaCl) and diluted (1.0%) or concentrated (12.0%) gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) using a T1-weighted (T1w) 2-dimensional fast field echo (FFE) and a T2-weighted single-shot (ssh) turbo spin-echo (TSE) fast dynamic sequence. The catheter artifacts were evaluated with regard to the contrast-to-noise ratio (CNR), the artifact width using the full width at half-maximum (FWHM) method, and the artifact intensity, being the product of the CNR and the FWHM. We used the general linear model procedure as the global test and the Tukey studentized range test for post hoc analysis. In vivo MR-guided freehand drainage was prospectively performed in patients with increased systemic inflammation markers and abdominal, retroperitoneal, and pelvic abscess collections. This study had been approved by the institutional review board. All patients provided written informed consent. Technical success was the primary efficacy variable. The secondary efficacy variables were visibility of the puncture needle and drainage catheter artifact, using a qualitative 5-point rating scale, intervention and procedure time, and rate of postinterventional complications. RESULTS: The FWHM, the CNR, and the artifact intensity of the drainage catheters filled with 0.9% NaCl or diluted or concentrated Gd-DTPA increased according to the drainage catheter size in an almost linear fashion in both image weighting (all P ≤ 0.006; all R(2) ≥ 0.73). The T1w FFE sequence yielded the highest FWHM, CNR, and artifact intensity of all groups, using 12.0% Gd-DTPA instillation (all P < 0.001), and the least FWHM and artifact intensity, using 1.0% Gd-DTPA instillation (all P < 0.022; all P < 0.009). The T2w ssh TSE yielded higher FWHM, using 12.0% Gd-DTPA instillation, whereas the CNR was higher for 0.9% NaCl instillation (all P < 0.001). Magnetic-resonance-guided abscess drainage was performed in 22 patients with 24 abdominal, retroperitoneal, or pelvic abscess collections. The technical success rate of in vivo MR-guided freehand drainage was 100%. Visibility of the puncture needle was excellent (≥4.4 [0.5] points). Visibility of the drainage catheters was rated with 3.9 (0.9) and 4.5 (0.8) points using T2w ssh TSE with 0.9% NaCl and 12.0% Gd-DTPA instillation as well as 4.8 (0.5) and 4.2 (0.8) points using T1w FFE with 1.0% and 12.0% Gd-DTPA instillation, respectively. The procedure and intervention time was 52.4 (16.4) minutes (range, 28-78 minutes) and 27.4 (7.2) minutes (range, 17-40 minutes). Two minor and no major complications were recorded. CONCLUSIONS: Magnetic-resonance-guided freehand percutaneous abscesses drainage using fast dynamic sequences in an open 1-T MR scanner is feasible, effective, and safe. Visualization of drainage catheters can be facilitated by instillation of 0.9% NaCl or diluted or concentrated contrast media.


Assuntos
Abscesso/patologia , Abscesso/cirurgia , Drenagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistemas Computacionais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
3.
Cardiovasc Intervent Radiol ; 34(1): 188-92, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20358370

RESUMO

The purpose of this study was to assess a new open system with a field-strength of 1.0 T for the feasibility of liver biopsy using the freehand technique with fast continuous imaging. Fifty patients with focal liver lesions measuring 5 to 30 mm in diameter were included in the study. Guidance and monitoring was performed using a 1.0-T open magnetic resonance (MR) scanner (Panorama HFO; Philips Healthcare, Best, The Netherlands). With fast continuous imaging using a T1-weighted (T1W) gradient echo (GRE) sequence after administration of gadolinium (Gd)-EOB-DTPA, the needle was placed into the lesion. An interface for interactive dynamic viewing in two perpendicular planes prevented needle deviations T2-weighted turbo spin echo (TSE) fat-suppressed sequence was added to rule out postinterventional hematoma or biloma. All lesions were visible on the interventional images. Biopsy was technically successful, and solid specimens were obtained in all cases. Forty-six patients showed a histopathologic pattern other than native liver tissue, thus confirming correct position of the needle. Time between determination of the lesion and performance of the control scan was on average 18 min. No major complications were recorded. MR guidance with the new 1-T open system must be considered an attractive alternative for liver punction. An interface for dynamic imaging of needle guidance and T1W-GRE imaging with administration of Gd-EOB-DTPA for contrast enhancement allows the pinpoint puncture of liver lesions.


Assuntos
Biópsia por Agulha/métodos , Hepatopatias/patologia , Imagem por Ressonância Magnética Intervencionista/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Software , Interface Usuário-Computador
4.
Cardiovasc Intervent Radiol ; 34(4): 857-63, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21161659

RESUMO

PURPOSE: The purpose of this study was to assess the safety and feasibility of MR-guided percutaneous nephrostomy (PCN) using a 1.0 Tesla open MR-scanner with fast dynamic imaging. METHODS: Twenty-five patients with failed ultrasonographic insertion due to various reasons, such as nondilated pelvic systems, obesity, and parapelvic cysts, were investigated. RESULTS: In summary, 35 nephrostomy procedures were performed; 15 patients received monolateral and 10 patients bilateral placement. For guidance and monitoring, fast T2w single-shot-TSE imaging in a fluoroscopic mode in two orthogonal planes was used to guide the insertion of the needle into a predetermined calyx in freehand technique. Nephrostomy was inserted via Seldinger-technique. The procedure was regarded as technically successful if the placement of the catheter provided adequate drainage of the collecting system. Demonstration of an intrapelvic position of the catheter was verified by antegrade pyelography using T1w GRE imaging after injection of diluted Gd-DTPA into the collecting system. Under the experimental conditions of the study, the time for the complete procedure was 30 (range, 23-39) min. Puncture and placement of the nephrostomy was performed in 5 (range, 3-10) min on average. CONCLUSIONS: Our results demonstrated a pinpoint puncture of the pelvic system in a reasonable timeframe even in patients with difficult conditions, suggesting that MR-guided PCN using the open 1 Tesla system can be assessed as a reliable, fast, and safe method applicable in the clinical routine setting.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Nefrostomia Percutânea/instrumentação , Cirurgia Assistida por Computador/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Drenagem/instrumentação , Estudos de Viabilidade , Feminino , Fluoroscopia/instrumentação , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Urografia/instrumentação , Adulto Jovem
5.
Eur Radiol ; 20(8): 1985-93, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20306080

RESUMO

OBJECTIVE: To determine the feasibility and safety of image-guided brachytherapy employing a modified open high-field MR system. METHODS: This is a follow-up study of a development project enabling technologies for interventional use of 1.0T open MRI. Modifications included coils and in-bore visualization, fluoroscopic sequences and user interfaces. We recruited 104 patients with 224 liver malignancies to receive MR-guided brachytherapy. Interventions were performed >20 min after Gd-EOB-DTPA. We recorded interventional parameters including the intervention time (from acquisition of the first scout until the final sequence for brachytherapy treatment planning). Two reviewers assessed MR-fluoroscopic images in comparison to plain CT as used in CT intervention, applying a rating scale of 1-10. Statistical analysis included Friedman and Kendall's W tests. RESULTS: We employed freehand puncture with interactive dynamic imaging for navigation. Technical success rate was 218 complete ablations in 224 tumours (97%). The median intervention time was 61 min. We recorded no adverse events related to the use of MRI. No major complications occurred. The rate of minor complications was 4%. Local control at 3 months was 96%. Superiority of MR-fluoroscopic, Gd-EOB-DTPA-enhanced images over plain CT was highly significant (P < 0.001). CONCLUSION: MR-guided brachytherapy employing open high-field MRI is feasible and safe.


Assuntos
Braquiterapia/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética/métodos , Radioterapia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento