Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 50(12): 3647-3658, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37480369

RESUMO

BACKGROUND: Aim of this study was to define the prognostic value of stress myocardial perfusion imaging by cadmium zinc telluride (CZT) single-photon emission computed tomography (SPECT) for prediction of adverse cardiovascular events in patients with known or suspected coronary artery disease (CAD). METHODS AND RESULTS: Studies published until November 2022 were identified by database search. We included studies using stress myocardial perfusion imaging by CZT-SPECT to evaluate subjects with known or suspected CAD and providing primary data of adverse cardiovascular events. Total of 12 studies were finally included recruiting 36,415 patients. Pooled hazard ratio (HR) for the occurrence of adverse events was 2.17 (95% confidence interval, CI, 1.78-2.65) and heterogeneity was 66.1% (P = 0.001). Five studies reported data on adjusted HR for the occurrence of adverse events. Pooled HR was 1.69 (95% CI, 1.44-1.98) and heterogeneity was 44.9% (P = 0.123). Seven studies reported data on unadjusted HR for the occurrence of adverse events. Pooled HR was 2.72 (95% CI, 2.00-3.70). Nine studies reported data useful to calculate separately the incidence rate of adverse events in patients with abnormal and normal myocardial perfusion. Pooled incidence rate ratio was 2.38 (95% CI, 1.39-4.06) and heterogeneity was 84.6% (P < 0.001). The funnel plot showed no evidence of asymmetry (P = 0.517). At meta-regression analysis, we found an association between HR for adverse events and presence of angina symptoms and family history of CAD. CONCLUSIONS: Stress myocardial perfusion imaging by CZT-SPECT is a valuable noninvasive prognostic indicator for adverse cardiovascular events in patients with known or suspected CAD.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cádmio , Prognóstico , Tomografia Computadorizada de Emissão
2.
Diagn Interv Imaging ; 104(7-8): 323-329, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36797156

RESUMO

Myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) assessment with non-invasive techniques represent an important tool to evaluate both coronary artery disease severity and extent. Currently, cardiac positron emission tomography-computed tomography (PET-CT) is the "gold standard" for the assessment of coronary function and provides accurate estimations of baseline and hyperemic MBF and MFR. Nevertheless, due to the high cost and complexity, PET-CT is not widely used in clinical practice. The introduction of cardiac-dedicated cadmium-zinc-telluride (CZT) cameras has renewed researchers' interest on MBF quantitation by single-photon emission computed tomography (SPECT). Indeed, many studies evaluated MPR and MBF measurements by dynamic CZT-SPECT in different cohorts of patients with suspected or overt coronary artery disease. As well, many others have compared the values obtained by CZT-SPECT to the ones by PET-CT, showing good correlations in detecting significant stenosis, although with different and non-standardized cut-off values. Nevertheless, the lack of standardized protocol for acquisition, reconstruction and elaboration makes more difficult to compare different studies and to further assess the real advantages of MBF quantitation by dynamic CZT-SPECT in clinical routine. Many are the issues involved in the bright and dark sides of dynamic CZT-SPECT. They include different type of CZT cameras, different execution protocols, different tracers with different myocardial extraction fraction and distribution, different software packages with different tools and algorithms, often requiring manual post-processing elaboration. This review article provides a clear summary of the state of the art on MBF and MPR evaluation by dynamic CZT-SPECT and outlines the major issues to solve to optimize this technique.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cádmio , Imagem de Perfusão do Miocárdio/métodos
3.
Eur J Nucl Med Mol Imaging ; 47(7): 1705-1712, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31848673

RESUMO

BACKGROUND: We measured myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) by a dynamic low-dose CZT-SPECT protocol in patients with suspected or known coronary artery disease (CAD) and investigated the capability of dynamic data in predicting obstructive CAD. A total of 173 patients with suspected or known CAD underwent dynamic CZT-SPECT after the injection of 155 MBq and 370 MBq of 99mTc-sestamibi for rest and stress imaging, respectively. Standard rest and stress imaging were performed at the end of each dynamic scan. A total perfusion defect (TPD) < 5% were considered normal. Obstructive CAD was defined as ≥ 70% stenosis at coronary angiography. RESULTS: Global MPR was lower (p < 0.05) in patients with abnormal compared with those with normal MPI (2.40 ± 0.7 vs. 2.70 ± 0.8). A weak, albeit significant correlation between TPD and MPR (r = - 0.179, p < 0.05) was found. In 91 patients with available angiographic data, hyperemic MBF (2.59 ± 1.2 vs. 3.24 ± 1.1 ml/min/g) and MPR (1.96 ± 0.7 vs. 2.74 ± 0.9) were lower (both p < 0.05) in patients with obstructive CAD (n = 21) compared with those without (n = 70). At univariable analysis, TPD, hyperemic MBF, and MPR were significant predictors of obstructive CAD, whereas only MPR was independent predictor at multivariable analysis (p < 0.05). At per vessels analysis, regional hyperemic MBF (2.59 ± 1.2 vs. 3.24 ± 1.1 ml/min/g) and regional MPR (1.96 ± 0.7 vs. 2.74 ± 0.9) were lower in the 31 vessels with obstructive CAD compared with 242 vessels without (both p < 0.05). CONCLUSIONS: In patients with suspected or known CAD, MPR assessed by low-dose dynamic CZT-SPECT showed a good correlation with myocardial perfusion imaging findings and it could be useful to predict obstructive CAD.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/instrumentação , Imagem de Perfusão do Miocárdio/métodos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA