Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
MAGMA ; 30(6): 609-620, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28744673

RESUMO

OBJECTIVE: This research utilizes magnetic resonance angiography (MRA) to identify arterial locations during the parametric evaluation of concentration time curves (CTCs), and to prevent shape distortions in arterial input function (AIF). MATERIALS AND METHODS: We carried out cluster analysis with the CTC parameters of voxels located within and around the middle cerebral artery (MCA). Through MRA, we located voxels that meet the AIF criteria and those with distorted CTCs. To minimize partial volume effect, we re-scaled the time integral of CTCs by the time integral of venous output function (VOF). We calculated the steady-state value to area under curve ratio (SS:AUC) of VOF and used it as a reference in selecting AIF. CTCs close to this reference value (selected AIF) and those far from it were used (eliminated AIF) to compute cerebral blood flow (CBF). RESULTS: Eliminated AIFs were found to be either on or anterior to MCA, whereas selected AIFs were located superior, inferior, posterior, or anterior to MCA. If the SS:AUC of AIF was far from the reference value, CBF was either under- or over-estimated by a maximum of 41.1 ± 14.3 and 36.6 ± 19.2%, respectively. CONCLUSION: MRA enables excluding voxels on the MCA during cluster analysis, and avoiding the risk of shape distortions.


Assuntos
Circulação Cerebrovascular/fisiologia , Angiografia por Ressonância Magnética/métodos , Artéria Cerebral Média/diagnóstico por imagem , Imagem de Perfusão/métodos , Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/fisiopatologia , Análise por Conglomerados , Meios de Contraste , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética/estatística & dados numéricos , Artéria Cerebral Média/fisiologia , Imagem de Perfusão/estatística & dados numéricos
2.
Int J Oral Maxillofac Implants ; 31(1): 55-62, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26478979

RESUMO

PURPOSE: Fractal analysis is a mathematical method used to describe the internal architecture of complex structures such as trabecular bone. Fractal analysis of panoramic radiographs of implant recipient sites could help to predict the quality of the bone prior to implant placement. This study investigated the correlations between the fractal dimension values obtained from panoramic radiographs and the insertion torque and resonance frequency values of mandibular implants. MATERIALS AND METHODS: Thirty patients who received a total of 55 implants of the same brand, diameter, and length in the mandibular premolar and molar regions were included in the study. The same surgical procedures were applied to each patient, and the insertion torque and resonance frequency values were recorded for each implant at the time of placement. The radiographic fractal dimensions of the alveolar bone in the implant recipient area were calculated from preoperative panoramic radiographs using a box-counting algorithm. The insertion torque and resonance frequency values were compared with the fractal dimension values using the Spearman test. RESULTS: All implants were successful, and none were lost during the follow-up period. Linear correlations were observed between the fractal dimension and resonance frequency, between the fractal dimension and insertion torque, and between resonance frequency and insertion torque. CONCLUSION: These results suggest that the noninvasive measurement of the fractal dimension from panoramic radiographs might help to predict the bone quality, and thus the primary stability of dental implants, before implant surgery.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Fractais , Mandíbula/diagnóstico por imagem , Radiografia Panorâmica/estatística & dados numéricos , Adulto , Algoritmos , Processo Alveolar/diagnóstico por imagem , Densidade Óssea/fisiologia , Retenção em Prótese Dentária , Feminino , Seguimentos , Previsões , Humanos , Masculino , Mandíbula/cirurgia , Pessoa de Meia-Idade , Torque , Vibração
3.
Med Dosim ; 39(3): 266-71, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24933316

RESUMO

Radiation fluence changes caused by the dosimeter itself and poor spatial resolution may lead to lack of 3-dimensional (3D) information depending on the features of the dosimeter and quality assurance of dose distributions for high-dose rate (HDR) iridium-192 ((192)Ir) brachytherapy sources is challenging and experimental dosimetry methods used for brachytherapy sources are limited. In this study, we investigated 3D dose distributions of (192)Ir brachytherapy sources for irradiation with single and multiple dwell positions using a normoxic gel dosimeter and compared them with treatment planning system (TPS) calculations. For dose calibration purposes, 100-mL gel-containing vials were irradiated at predefined doses and then scanned in an magnetic resonance (MR) imaging unit. Gel phantoms prepared in 2 spherical glasses were irradiated with (192)Ir for the calculated dwell positions, and MR scans of the phantoms were obtained. The images were analyzed with MATLAB software. Dose distributions and profiles derived with 1-mm resolution were compared with TPS calculations. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. The x-, y-, and z-axes were defined as the sagittal, coronal, and axial planes, respectively, the sagittal and axial planes were defined parallel to the long axis of the source while the coronal plane was defined horizontally to the long axis of the source. The differences between measured and calculated profile widths of 3-cm source length and point source for 70%, 50%, and 30% isodose lines were evaluated at 3 dose levels using 18 profiles of comparison. The calculations for 3-cm source length revealed a difference of > 3mm in 1 coordinate at 50% profile width on the sagittal plane and 3 coordinates at 70% profile width and 2 coordinates at 50% and 30% profile widths on the axial plane. Calculations on the coronal plane for 3-cm source length showed > 3-mm difference in 1 coordinate at 50% and 70% and 2 coordinates at 30% profile widths. The point source measurements and calculations for 50% profile widths revealed a difference > 3mm in 1 coordinate on the sagittal plane and 2 coordinates on the axial plane. The doses of 3 coordinates on the sagittal plane and 4 coordinates on the axial plane could not be evaluated in 30% profile width because of low doses. There was good agreement between the gel dosimetry and TPS results. Gel dosimetry provides dose distributions in all 3 planes at the same time, which enables us to define the dose distributions in any plane with high resolution. It can be used to obtain 3D dose distributions for HDR (192)Ir brachytherapy sources and 3D dose verification of TPS.


Assuntos
Braquiterapia , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador , Ácido Ascórbico , Sulfato de Cobre , Gelatina , Humanos , Hidroquinonas , Metacrilatos , Polímeros , Radiometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA