Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Surg ; 24(1): 157, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755649

RESUMO

BACKGROUND: Fractures involving the posterior acetabulum with its rich vascular and neural supply present challenges in trauma orthopedics. This study evaluates the effectiveness of 3D printing technology with the use of custom-made metal plates in the treatment of posterior wall and column acetabular fractures. METHODS: A retrospective analysis included 31 patients undergoing surgical fixation for posterior wall and column fractures of the acetabulum (16 in the 3D printing group, utilizing 3D printing for a 1:1 pelvic model and custom-made plates based on preoperative simulation; 15 in the traditional group, using conventional methods). Surgical and instrument operation times, intraoperative fluoroscopy frequency, intraoperative blood loss, fracture reduction quality, fracture healing time, preoperative and 12-month postoperative pain scores (Numeric Rating Scale, NRS), hip joint function at 6 and 12 months (Harris scores), and complications were compared. RESULTS: The surgical and instrument operation times were significantly shorter in the 3D printing group (p < 0.001). The 3D printing group exhibited significantly lower intraoperative fluoroscopy frequency and blood loss (p = 0.001 and p < 0.001, respectively). No significant differences were observed between the two groups in terms of fracture reduction quality, fracture healing time, preoperative pain scores (NRS scores), and 6-month hip joint function (Harris scores) (p > 0.05). However, at 12 months, hip joint function and pain scores were significantly better in the 3D printing group (p < 0.05). Although the incidence of complications was lower in the 3D printing group (18.8% vs. 33.3%), the difference did not reach statistical significance (p = 0.433). CONCLUSION: Combining 3D printing with individualized custom-made metal plates for acetabular posterior wall and column fractures reduces surgery and instrument time, minimizes intraoperative procedures and blood loss, enhancing long-term hip joint function recovery. CLINICAL TRIAL REGISTRATION: 12/04/2023;Trial Registration No. ChiCTR2300070438; http://www.chictr.org.cn .


Assuntos
Acetábulo , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Impressão Tridimensional , Humanos , Estudos Retrospectivos , Acetábulo/cirurgia , Acetábulo/lesões , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Resultado do Tratamento , Fraturas Ósseas/cirurgia , Duração da Cirurgia , Adulto Jovem , Desenho de Prótese , Idoso
2.
Front Surg ; 11: 1383401, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38817945

RESUMO

Background: In recent years, 3D printing technology has made significant strides in the medical field. With the advancement of orthopedics, there is an increasing pursuit of high surgical quality and optimal functional recovery. 3D printing enables the creation of precise physical models of fractures, and customized personalized steel plates can better realign and more comprehensively and securely fix fractures. These technologies improve preoperative diagnosis, simulation, and planning for complex limb fractures, providing patients with better treatment options. Patients and methods: Five typical cases were selected from a pool of numerous patients treated with 3D printing technology combined with personalized custom steel plates at our hospital. These cases were chosen to demonstrate the entire process of printing 3D models and customizing individualized steel plates, including details of the patients' surgeries and treatment procedures. Literature reviews were conducted, with a focus on highlighting the application of 3D printing technology combined with personalized custom steel plates in the treatment of complex limb fractures. Results: 3D printing technology can produce accurate physical models of fractures, and personalized custom plates can achieve better fracture realignment and more comprehensive and robust fixation. These technologies provide patients with better treatment options. Conclusion: The use of 3D printing models and personalized custom steel plates can improve preoperative diagnosis, simulation, and planning for complex limb fractures, realizing personalized medicine. This approach helps reduce surgical time, minimize trauma, enhance treatment outcomes, and improve patient functional recovery.

3.
PLoS One ; 19(5): e0302839, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696506

RESUMO

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Assuntos
Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Cominutivas , Patela , Humanos , Masculino , Feminino , Adulto , Patela/cirurgia , Patela/lesões , Fraturas Cominutivas/cirurgia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Estudos Retrospectivos , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Resultado do Tratamento , Fraturas Ósseas/cirurgia , Consolidação da Fratura , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Adulto Jovem , Parafusos Ósseos , Âncoras de Sutura
4.
J Orthop Surg Res ; 18(1): 669, 2023 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-37689739

RESUMO

BACKGROUND: ue to the lack of consensus on the optimal surgical treatment for distal radius fractures (DRF) in elderly patients over 65 years old, the purpose of this study was to compare the efficacy of external fixation (EF) with Kirschner wires and volar locking plate (VLP) in the treatment of DRF through a retrospective cohort study. We hypothesized that there would be no significant difference in overall complications and functional recovery between the two methods. METHODS: We retrospectively analyzed 62 patients over 65 years old who underwent surgical treatment for C-type DRF between 2019 and 2022. Based on the different treatment methods, they were divided into the EF group and the VLP group. General data, inpatient data, and postoperative complications during follow-up were recorded. The X-ray images before surgery, after surgery, and at the last follow-up were analyzed, and the results of wrist motion range, Gartland-Werley wrist joint score, and DASH score were evaluated 6 months after surgery for both groups. RESULT: Thirty patients underwent closed reduction and external fixation combined with Kirschner wire fixation, while 32 underwent open reduction and VLP fixation. The EF group had significantly shorter operation time, intraoperative blood loss, injury-to-surgery time, and hospital stay compared to the VLP group (all p < 0.001). At the last follow-up, the radiographic parameters (ulnar variance and radial inclination) and wrist joint function (wrist dorsiflexion and forearm supination) were better in the VLP group than in the EF group (p = 0.04, p = 0.01, p = 0.001, p = 0.02, respectively). However, there was no significant difference in overall Gartland-Werley wrist joint score, DASH score, and incidence of postoperative complications between the two groups (p = 0.31, p = 0.25, p = 0.47, respectively). CONCLUSION: For patients aged 65 and above with distal radius fractures (DRF) of type C, VLP and external fixation with Kirschner wires yield comparable functional outcome and complications rate at the short term. However, VLP allowed restoration of better radiological parameters.


Assuntos
Fios Ortopédicos , Fraturas do Punho , Idoso , Humanos , Estudos Retrospectivos , Fixadores Externos , Fixação de Fratura , Complicações Pós-Operatórias
5.
BMC Surg ; 22(1): 276, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35840959

RESUMO

BACKGROUND: Accurate classification of femoral neck fracture (FNF) is crucial for treatment plan and therapeutic outcomes. Garden classification is commonly used in the clinic, but its stability and consistency remain controversial. The aim of this study was to evaluate the stability and consistency of Garden classification based on X and CT images, and to analyze whether it is valid for Garden I in the elderly. METHODS: X-ray and CT images from 886 elderly patients with FNF were collected, four orthopaedic surgeons and four radiologists evaluated these images independently, and determined the fracture type based on Garden classification. Three months later, The exercise was repeated and the results were compared based on 4 types Garden classification (I, II, III and IV) and 3 types Garden classification (I + II, III and IV). Kappa was used to measure inter- and intraobserver agreement. The patients with Garden I incomplete FNF confirmed by 8 observers together based on images combined with medical history were compared with the intraoperative results. RESULTS: Four types Garden classification, there was little consistency inter- and intraobservers (Kappa from 0.18 to 0.43) based on X-ray images, while professors consistency (0.56 to 0.76) was higher than residents (0.28 to 0.35) based on CT. 3 types Garden classification showed almost perfect agreement inter- and intraobservers, which ranged from 0.76 to 0.90. Totally 52 patients were diagnosed as Garden I, 38 of whom underwent arthroplasty. All surgical cases showed complete fracture during operation. CONCLUSIONS: There was low consistency and repeatability in 4 types Garden classification (I, II, III and IV), while 3 types Garden classification (I + II, III and IV) had high consistency among observers. In the elderly, all undisplaced femoral neck fracture may be Garden II, no Garden I.


Assuntos
Fraturas do Colo Femoral , Idoso , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Humanos , Radiografia
6.
J Orthop Surg Res ; 16(1): 256, 2021 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-33853657

RESUMO

BACKGROUND: Accurate femoral neck anteversion angle (FNA) measurement is of great significance in the diagnosis and treatment of developmental dysplasia of the hip (DDH) in children. The FNA measurement still remains a controversy. We aimed to verify the accuracy of our CT method by 3D printing technology and to evaluate its clinical value. METHODS: Sixty-eight children with unilateral DDH were enrolled, and their FNA was measured using 2D-CT and 3D-CT, respectively, by three observers. This procedure was repeated 3 months later. The above measurement outcomes were then compared with the results in the 3D-printed femur (3D-PF) model. The FNA in the 3D-PF model was measured by three observers (two radiologists and one orthopedist; all were professors) collectively through electronic angle instrument. RESULTS: The primary measurement of FNA at the affected hips by 2D-CT was 44.0 ± 6.1, 49.5 ± 8.9, and 52.8 ± 7.9°, respectively. On the 3D-CT, it was 47.6 ± 5.4, 49.3 ± 6.8, and 48.6 ± 6.2°. Three months later, the FNA on 2D-CT was 49.3 ± 10.5, 42.8 ± 7.4, and 45.1 ± 9.3°, and it was 48.0 ± 6.5, 48.9 ± 7.2, and 49.0 ± 5.7° on 3D-CT, respectively. The FNA in the 3D-PF model at the affected and unaffected hips was 48.5 ± 6.6 and 36.9 ± 13.1°. There were significant differences between 2D-CT and 3D-PF measurements, but no significant difference was found between 3D-CT and 3D-PF measurements. The results by 2D-CT showed significant differences among groups and between the groups. However, the results by 3D-CT had no significant differences among groups or between the groups. CONCLUSION: The results of our study showed that 3D-CT is a more precise, and reproducible method for FNA measurement in DDH. The FNA at the affected hips is 11.6° larger than the unaffected in DDH children aged 3-8 years.


Assuntos
Displasia do Desenvolvimento do Quadril/diagnóstico por imagem , Displasia do Desenvolvimento do Quadril/patologia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/patologia , Imageamento Tridimensional/métodos , Impressão Tridimensional , Tomografia Computadorizada por Raios X/métodos , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Medicine (Baltimore) ; 98(41): e17547, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31593135

RESUMO

RATIONALE: Leakage of bone cement from femoral medullary cavity is a rare complication after hip arthroplasty, and there is no report on the leaked bone cement entering into iliac vessels. PATIENT CONCERNS: An 89-year-old woman presented with a fracture in the right femoral neck. She had well-fixed right femoral head replacement after careful preoperative examinations, and no adverse reactions appeared. She was able to get off bed to walk at the 2nd day after surgery. DIAGNOSES: Postoperative radiograph showed leakage of bone cement into the joint through femoral medullary cavity entering into iliac vessels, but the patient complained no discomforts. She received a treatment with low-molecular weight heparin and rivaroxaban. OUTCOMES: The patient was able to walk with normal gait, without swelling in both lower extremities and discomfort in the hip. There was no other complication concerning intravascular foreign bodies. LESSONS: This case calls into the phenomenon of leakage of injected bone cement in femoral head replacement regardless of complete and nonfractured femur, which may be into the lower limb and pelvic veins, given that, dangerous consequences will not occur.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos/efeitos adversos , Cabeça do Fêmur/cirurgia , Veia Ilíaca/patologia , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Feminino , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Veia Ilíaca/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Radiografia/métodos , Rivaroxabana/uso terapêutico , Resultado do Tratamento
8.
J Pediatr Orthop ; 38(4): e180-e185, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29356794

RESUMO

BACKGROUND: One of the important pathologic changes in developmental dysplasia of the hip (DDH) is increased acetabular version angle (AA). Reasonable correction for excessive AA is an important step in the treatment of DDH, making accurate AA measurement very crucial. However, the results of different AA measurement methods vary. Thus, this study aimed to compare the difference in AA measurements between 2-dimensional computed tomography (2D-CT) and 3-dimensional computed tomography (3D-CT) in children with DDH and to identify the AA degree in children with DDH to guide treatment. METHODS: AA was measured by 2D-CT and 3D-CT in 186 children with DDH, and the measurement results were compared with the physical measurement result in the 3D-printed pelvis (3D-PP) model. The 3D-PP was a 1:1 model identical to the human pelvis. All patients were unilaterally affected. RESULTS: The results of AA measurement through 2D-CT, 3D-CT, and 3D-PP of normal hips were 14.0±6.6, 11.9±5.3, and 11.9±3.4 degrees, respectively, whereas those of the dislocated hips were 24.9±8.9, 19.8±5.2, and 19.5±4.3 degrees, respectively. In both the normal and dislocated hip groups, the results between 2D-CT and 3D-CT was significantly different (P<0.05), but there was no difference between the results of 3D-CT and 3D-PP (P>0.05). The AA of the normal and dislocated hips as measured by 3D-PP was 11.9±3.6 and 19.6±4.3 degrees, respectively, with statistically significant difference (P<0.05). In the dislocated hips, a significant positive correlation was found between age and AA (r=0.756, P<0.05) and between AA and degree of dislocation (r=0.837, P<0.05). CONCLUSIONS: 3D-CT is more accurate than 2D-CT for AA measurement, and compared with normal hips, AA in dislocated hips increased by ∼7.7 degrees on average. AA increases as age and degree of dislocation increase. LEVEL OF EVIDENCE: Level II.


Assuntos
Acetábulo/diagnóstico por imagem , Anteversão Óssea/diagnóstico por imagem , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação do Quadril/diagnóstico por imagem , Impressão Tridimensional , Tomografia Computadorizada por Raios X/métodos , Acetábulo/patologia , Anteversão Óssea/patologia , Criança , Feminino , Luxação do Quadril/patologia , Luxação Congênita de Quadril/patologia , Humanos , Imageamento Tridimensional/métodos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Estudos Retrospectivos
9.
J Int Med Res ; 45(1): 272-281, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28222640

RESUMO

Objective To evaluate the effect of dynamic long leg casting in paediatric patients with developmental dysplasia of hip (DDH) diagnosed at 12-18 months. Methods The adductor tenotomy, closed reduction, and dynamic long leg casting method was adopted to treat paediatric patients with DDH. The hips were divided into four groups according to the Tonnis radiographic dislocation classification. Groups were also classified according to the baseline acetabular index (AI): 30°-35°, 36°-40°, and > 40°. The outcomes of the reductions were evaluated according to McKay's hip function criteria and Severin's radiological criteria. Results A total of 246 patients (339 hips) had complete follow-up data. After 3 months of orthosis fixation, the results were satisfactory in 264 hips (77.88%). Hip function was rated as 'excellent' or 'good' in 43 of 51 (84.31%) Tonnis type 1 hips, 125 of 155 (80.65%) type 2 hips, 70 of 90 (77.78%) type 3 hips, and 34 of 43 (79.07%) type 4 hips. The higher the baseline AI, the lower the rates of 'excellent' and 'good' hip function. Favourable radiological results (Severin types I and II) were found in 266 of 339 (78.47) hips. Conclusions Dynamic long leg casting is an effective method for treating patients with DDH aged 12-18 months at diagnosis.


Assuntos
Moldes Cirúrgicos , Luxação Congênita de Quadril/cirurgia , Quadril/cirurgia , Aparelhos Ortopédicos , Tendões/cirurgia , Tenotomia/métodos , Feminino , Quadril/anormalidades , Luxação Congênita de Quadril/patologia , Humanos , Lactente , Masculino , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica/fisiologia , Estudos Retrospectivos , Tendões/anormalidades , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA