1.
J Arthroplasty ; 24(1): 33-7, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18534441

RESUMO

A prospective randomized trial comparing hydroxyapatite (HA)-coated and non-HA-coated femoral total hip arthroplasty components was conducted. Sixty-one consecutive patients undergoing primary hip arthroplasty were randomized to receive an identical femoral component with or without HA. Forty-eight hips were available for review at an average of 13 years and 5 months after surgery. The only femoral stem revised was secondary to femoral fracture after mitral valve area. All femoral stems were well fixed on x-ray with no evidence of loosening. There was no statistically significant difference in the revision rates or in the Harris hip score between the HA vs non-HA-coated groups. This study suggests there is no clinical advantage to the use of a hydroxyapatite coating on the femoral component of this design for primary total hip arthroplasty.


Assuntos
Artroplastia de Quadril/instrumentação , Durapatita , Fêmur , Prótese de Quadril , Adulto , Artroplastia de Quadril/métodos , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Reoperação , Resultado do Tratamento