Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Audiol Neurootol ; 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39182488

RESUMO

INTRODUCTION: Preservation of residual hearing, mainly the low frequencies, is the current main objective of cochlear implantation. New electrode arrays and the development of minimally invasive surgery have allowed electroacoustic stimulation. Over the past several years, robotic-assisted cochlear implant surgery aimed to improve the insertion process while respecting inner ear structures. However, the introduction of a foreign body inside the cochlea can lead to the development of fibrous tissue around the electrode array, or even induce osteogenesis. These histological changes disrupt the parameters of the cochlear implant, resulting in elevated impedance. In addition, long-term auditory performance can be affected, with a deterioration in word comprehension. We evaluated the potential impact of RobOtol® on impedance changes over time, leading to potentially positive functional outcomes. METHODS: Cochlear implant surgery with a round window approach was performed under general anesthesia. Fifteen Med-El Flex24 electrode arrays were inserted manually and 24 using RobOtol®. All subjects underwent pure-tone audiometry tests before the surgery and at regular intervals up to 1 year after the surgery. Based on the pure-tone average at the low frequencies from 250 to 1,000 Hz, we divided the patients according to the degree of auditory preservation (full preservation ≤ 15 dB, partial preservation 15 dB to 30 dB, significant loss > 30 dB). These different groups were compared in terms of impedance changes and auditory performance, specifically word recognition score. RESULTS: We found proportionally fewer patients who experienced significant low-frequency hearing loss after robotic insertion (53.33% in the manual group compared to 41.67% in the robot-assisted insertion group). Impedance changes at the apex of the electrode array, especially at the first electrode (p=0.04), after robotic surgery, with less overall variability, a continuous decreasing trend without secondary elevation, and lower values in cases of complete residual hearing preservation (for the three first electrodes: p = 0.017, p = 0.04, p = 0.045). The speech intelligibility amelioration over time showed favorable evolution in patients with complete residual hearing preservation regardless of the insertion method. However, in the absence of auditory preservation, the positive evolution continued more than 6 months after robotic surgery but stagnated after manual insertion (difference at 1 year, p = 0.038; median auditory capacity index 83% vs. 57%). CONCLUSION: Atraumatic electrode array insertion with consistent, slow speed and the assistance of RobOtol® minimizes disturbances in the delicate neurosensory structures of the inner ear and leads to better auditory performance.

2.
J Craniomaxillofac Surg ; 52(4): 420-431, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38461138

RESUMO

The study aimed to evaluate and discuss the use of an innovative PSI made of porous hydroxyapatite, with interconnected porosity promoting osteointegration, called MyBone Custom® implant (MBCI), for maxillofacial bone reconstruction. A multicentric cohort of 13 patients underwent maxillofacial bone reconstruction surgery using MBCIs for various applications, from genioplasty to orbital floor reconstruction, including zygomatic and mandibular bone reconstruction, both for segmental defects and bone augmentation. The mean follow-up period was 9 months (1-22 months). No infections, displacements, or postoperative fractures were reported. Perioperative modifications of the MBCIs were possible when necessary. Additionally, surgeons reported significant time saved during surgery. For patients with postoperative CT scans, osteointegration signs were visible at the 6-month postoperative follow-up control, and continuous osteointegration was observed after 1 year. The advantages and disadvantages compared with current techniques used are discussed. MBCIs offer new bone reconstruction possibilities with long-term perspectives, while precluding the drawbacks of titanium and PEEK. The low level of postoperative complications associated with the high osteointegration potential of MBCIs paves the way to more extensive use of this new hydroxyapatite PSI in maxillofacial bone reconstruction.


Assuntos
Implantes Dentários , Procedimentos de Cirurgia Plástica , Humanos , Durapatita/uso terapêutico , Tomografia Computadorizada por Raios X , Órbita
3.
Audiol Neurootol ; 29(3): 228-238, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38190808

RESUMO

INTRODUCTION: Cochlear implants (CIs) can restore binaural hearing in cases of single-sided deafness (SSD). However, studies with a high level of evidence in support of this phenomenon are lacking. The aim of this study is to analyze the effectiveness of CIs using several spatialized speech-in-noise tests and to identify potential predictors of successful surgery. METHODS: Ten cases underwent standard CI surgery (MEDEL-Flex24). The speech-in-noise test was used in three different spatial configurations. The noise was presented from the front (N0), toward the CI (NCI), and toward the ear (Near), while the speech was always from the front (S0). For each test, the speech-to-noise ratio at 50% intelligibility (SNR50) was evaluated. Seven different effects were assessed (summation, head shadow [HS], speech released of masking [SRM], and squelch for the CI and for the ear). RESULTS: A significant summation effect of 1.5 dB was observed. Contralateral PTA was positively correlated with S0N0-B and S0NCI-B (CIon and unplugged ear). S0N0-B results were positively correlated with S0N0-CIoff (p < 0.0001) and with S0Near-CIoff results (p = 0.004). A significant positive correlation was found between delay post-activation and HS gain for the CI (p = 0.005). Finally, the HS was negatively correlated with the squelch effect for the ear. CONCLUSION: CI benefits patients with SSD in noise and can improve the threshold for detecting low-level noise. Contralateral PTA could predict good postoperative results. Simple tests performed preoperatively can predict the likelihood of surgical success in reversing SSD.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Percepção da Fala , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/reabilitação , Perda Auditiva Unilateral/fisiopatologia , Adulto , Idoso , Localização de Som , Resultado do Tratamento , Ruído
4.
Front Endocrinol (Lausanne) ; 14: 1242588, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37711900

RESUMO

Introduction: Prolactinomas are the most frequent type of pituitary adenoma encountered in clinical practice. Dopamine agonists (DA) like cabergoline typically provide sign/ symptom control, normalize prolactin levels and decrease tumor size in most patients. DA-resistant prolactinomas are infrequent and can occur in association with some genetic causes like MEN1 and pathogenic germline variants in the AIP gene (AIPvar). Methods: We compared the clinical, radiological, and therapeutic characteristics of AIPvar-related prolactinomas (n=13) with unselected hospital-treated prolactinomas ("unselected", n=41) and genetically-negative, DA-resistant prolactinomas (DA-resistant, n=39). Results: AIPvar-related prolactinomas occurred at a significantly younger age than the unselected or DA-resistant prolactinomas (p<0.01). Males were more common in the AIPvar (75.0%) and DA- resistant (49.7%) versus unselected prolactinomas (9.8%; p<0.001). AIPvar prolactinomas exhibited significantly more frequent invasion than the other groups (p<0.001) and exhibited a trend to larger tumor diameter. The DA-resistant group had significantly higher prolactin levels at diagnosis than the AIPvar group (p<0.001). Maximum DA doses were significantly higher in the AIPvar and DA-resistant groups versus unselected. DA-induced macroadenoma shrinkage (>50%) occurred in 58.3% in the AIPvar group versus 4.2% in the DA-resistant group (p<0.01). Surgery was more frequent in the AIPvar and DA- resistant groups (43.8% and 61.5%, respectively) versus unselected (19.5%: p<0.01). Radiotherapy was used only in AIPvar (18.8%) and DA-resistant (25.6%) groups. Discussion: AIPvar confer an aggressive phenotype in prolactinomas, with invasive tumors occurring at a younger age. These characteristics can help differentiate rare AIPvar related prolactinomas from DA-resistant, genetically-negative tumors.


Assuntos
Neoplasias Hipofisárias , Prolactinoma , Humanos , Masculino , Agonistas de Dopamina , Células Germinativas , Neoplasias Hipofisárias/genética , Neoplasias Hipofisárias/terapia , Prolactina , Prolactinoma/tratamento farmacológico , Prolactinoma/genética , Receptores de Hidrocarboneto Arílico
6.
Ear Nose Throat J ; 101(2_suppl): 24S-30S, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33734883

RESUMO

OBJECTIVES: The aim of this study was to assess the predictive value of the Vandenberg and Kuse Mental Rotation Test (MRT) on performance of novice medical students for manipulation of a nasal endoscope on a cadaveric model. MATERIAL AND METHOD: We randomly selected 39 medical students who had never handled a nasal endoscope and subjected them to the MRT. General information including experience in manual, technical, or surgical activities and testing of anatomical knowledge were collected to exclude possible confounding factors. They were then asked to perform series of cadaveric model exercises using a nasal endoscope. Their cadaver performance was evaluated by 2 blinded observers, using a standardized scale. RESULTS: We found that medical students with higher mental rotation skills had significantly increased endoscopic sinus performance (P = .0002 using multivariate regression adjusted for specialty choice, previous surgical exposure, and anatomy knowledge). Higher anatomy knowledge was also associated with better endoscopic sinus performance (P = .0141). Other parameters had no impact on endoscopic sinus performance measured by the endoscopic scale (P > .05). CONCLUSION: The score obtained on the MRT was correlated with the practical performance of manipulating the nasal endoscope in cadaver. It could therefore be a useful spatial ability tool for directing targeted training in rhinology.


Assuntos
Seios Paranasais , Estudantes de Medicina , Cadáver , Endoscopia/educação , Humanos , Cavidade Nasal , Seios Paranasais/cirurgia
7.
Audiol Neurootol ; 26(5): 361-367, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33902040

RESUMO

INTRODUCTION: Cochlear implants (CIs) are commonly used for the rehabilitation of profound bilateral hearing loss. However, patients with substantial residual acoustic hearing are potential CI candidates. Because of both improvements in technology and advancements in surgical techniques, it may be possible to preserve hearing to some extent. For more than a decade, it has been suggested that robots are used to perform middle ear surgery. We evaluated the use of the RobOtol® otologic robot specifically to insert CI electrodes into the inner ear. METHODS: CI surgery with the conventional approach was performed under general anesthesia. The MED-El Flex 24-electrode array was inserted using RobOtol®. Video recordings were used to calculate the speed of insertion. The positions of the electrodes were evaluated using a cone beam CT. All subjects underwent pure-tone audiometry tests before and after surgery, and the pure-tone average (PTA) was calculated from 250 to 4,000 Hz. RESULTS: The robot inserted implants in 5 patients, and complete insertion of the electrode array was achieved. The speed of insertion of the electrode array was 0.88 ± 0.12 mm/s. The mean loss of the PTA for 5 frequencies (250, 500, 1,000, 2,000, and 4,000 Hz) was 13.60 ± 7.70 dB. Only 1 patient showed a loss of the PTA by >20 dB. For these 5 patients, the cone beam CT findings showed that all the electrode arrays were in the tympanic ramp and had a grade of 0. The results were compared with those obtained from a cohort of 17 patients who underwent manual implantation of a MED-El Flex 24-electrode array. CONCLUSION: To minimize disturbance to the cochlea while atraumatic electrode arrays are inserted, electrodes can be inserted at a constant, slow speed in the inner ear with the assistance of the RobOtol® robot in a normal clinical surgical setting.


Assuntos
Implante Coclear , Implantes Cocleares , Robótica , Audiometria de Tons Puros , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Eletrodos Implantados , Estudos de Viabilidade , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA