RESUMO
Background and Purpose: Intravoxel-incoherent-motion (IVIM) magnetic-resonance-imaging (MRI) and positron-emission-tomography (PET) have been investigated independently but not voxel-wise to evaluate tumor microenvironment in cervical carcinoma patients. Whether regionally combined information of IVIM and PET offers additional predictive benefit over each modality independently has not been explored. Here, we investigated parametric-response-mapping (PRM) of co-registered PET and IVIM in cervical cancer patients to identify sub-volumes that may predict tumor shrinkage to concurrent-chemoradiation-therapy (CCRT). Materials and Methods: Twenty cervical cancer patients (age: 63[41-85]) were retrospectively evaluated. Diffusion-weighted-images (DWIs) were acquired on 3.0 T MRIs using a free-breathing single-shot-spin echo-planar-imaging (EPI) sequence. Pre- and on-treatment (â¼after four-weeks of CCRT) MRI and pre-treatment FDG-PET/CT were acquired. IVIM model-fitting on the DWIs was performed using a Bayesian-fitting simplified two-compartment model. Three-dimensional rigidly-registered maps of PET/CT standardized-uptake-value (SUV) and IVIM diffusion-coefficient (D) and perfusion-fraction (f) were generated. Population-means of PET-SUV, IVIM-D and IVIM-f from pre-treatment-scans were calculated and used to generate PRM via a voxel-wise joint-histogram-analysis to classify voxels as high/low metabolic-activity and with high/low (hi/lo) cellular-density. Similar PRM maps were generated for SUV and f. Results: Tumor-volume (p < 0.001) significantly decreased, while IVIM-f (p = 0.002) and IVIM-D (p = 0.03) significantly increased on-treatment. Pre-treatment tumor-volume (r = -0.45,p = 0.04) and PRM-SUVhi D lo (r = -0.65,p = 0.002) negatively correlated with ΔGTV, while pre-treatment IVIM-D (r = 0.64,p = 0.002), PRM-SUVlo f hi (r = 0.52,p = 0.02), and PRM-SUVlo D hi (r = 0.74,p < 0.001) positively correlated with ΔGTV. Conclusion: IVIM and PET was performed on cervical cancer patients undergoing CCRT and we observed that both IVIM-f and IVIM-D increased during treatment. Additionally, PRM was applied, and sub-volumes were identified that were related to ΔGTV.
RESUMO
BACKGROUND: Adverse radiation effect (ARE) following stereotactic radiosurgery (SRS) for brain metastases is challenging to distinguish from tumor progression. This study characterizes the clinical implications of radiologic uncertainty (RU). METHODS: Cases reviewed retrospectively at a single-institutional, multi-disciplinary SRS Tumor Board between 2015-2022 for RU following SRS were identified. Treatment history, diagnostic or therapeutic interventions performed upon RU resolution, and development of neurologic deficits surrounding intervention were obtained from the medical record. Differences in lesion volume and maximum diameter at RU onset versus resolution were compared with paired t-tests. Median time from RU onset to resolution was estimated using the Kaplan-Meier method. Univariate and multivariate associations between clinical characteristics and time to RU resolution were assessed with Cox proportional-hazards regression. RESULTS: Among 128 lesions with RU, 23.5% had undergone ≥ 2 courses of radiation. Median maximum diameter (20 vs. 16 mm, p < 0.001) and volume (2.7 vs. 1.5 cc, p < 0.001) were larger upon RU resolution versus onset. RU resolution took > 6 and > 12 months in 25% and 7% of cases, respectively. Higher total EQD2 prior to RU onset (HR = 0.45, p = 0.03) and use of MR perfusion (HR = 0.56, p = 0.001) correlated with shorter time to resolution; larger volume (HR = 1.05, p = 0.006) portended longer time to resolution. Most lesions (57%) were diagnosed as ARE. Most patients (58%) underwent an intervention upon RU resolution; of these, 38% developed a neurologic deficit surrounding intervention. CONCLUSIONS: RU resolution took > 6 months in > 25% of cases. RU may lead to suboptimal outcomes and symptom burden. Improved characterization of post-SRS RU is needed.
Assuntos
Neoplasias Encefálicas , Lesões por Radiação , Radiocirurgia , Humanos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Resultado do Tratamento , Estudos Retrospectivos , Incerteza , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/patologia , Lesões por Radiação/diagnóstico por imagem , Lesões por Radiação/etiologia , Lesões por Radiação/cirurgiaRESUMO
PURPOSE: Surface-guided radiation-therapy (SGRT) systems are being adopted into clinical practice for patient setup and motion monitoring. However, commercial systems remain cost prohibitive to resource-limited clinics around the world. Our aim is to develop and validate a smartphone-based application using LiDAR cameras (such as on recent Apple iOS devices) for facilitating SGRT in low-resource centers. The proposed SGRT application was tested at multiple institutions and validated using phantoms and volunteers against various commercial systems to demonstrate feasibility. METHODS AND MATERIALS: An iOS application was developed in Xcode and written in Swift using the Augmented-Reality (AR) Kit and implemented on an Apple iPhone 13 Pro with a built-in LiDAR camera. The application contains multiple features: 1) visualization of both the camera and depth video feeds (at a â¼60Hz sample-frequency), 2) region-of-interest (ROI) selection over the patient's anatomy where motion is measured, 3) chart displaying the average motion over time in the ROI, and 4) saving/exporting the motion traces and surface map over the ROI for further analysis. The iOS application was tested to evaluate depth measurement accuracy for: 1) different angled surfaces, 2) different field-of-views over different distances, and 3) similarity to a commercially available SGRT systems (Vision RT AlignRT and Varian IDENTIFY) with motion phantoms and healthy volunteers across 3 institutions. Measurements were analyzed using linear-regressions and Bland-Altman analysis. RESULTS: Compared with the clinical system measurements (reference), the iOS application showed excellent agreement for depth (r = 1.000, P < .0001; bias = -0.07±0.24 cm) and angle (r = 1.000, P < .0001; bias = 0.02±0.69°) measurements. For free-breathing traces, the iOS application was significantly correlated to phantom motion (institute 1: r = 0.99, P < .0001; bias =-0.003±0.03 cm; institute 2: r = 0.98, P < .0001; bias = -0.001±0.10 cm; institute 3: r = 0.97, P < .0001; bias = 0.04±0.06 cm) and healthy volunteer motion (institute 1: r = 0.98, P < .0001; bias = -0.008±0.06 cm; institute 2: r = 0.99, P < .0001; bias = -0.007±0.12 cm; institute 3: r = 0.99, P < .0001; bias = -0.001±0.04 cm). CONCLUSIONS: The proposed approach using a smartphone-based application provides a low-cost platform that could improve access to surface-guided radiation therapy accounting for motion.
Assuntos
Radioterapia Guiada por Imagem , Smartphone , Humanos , Radioterapia Guiada por Imagem/métodos , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador/métodosRESUMO
PURPOSE: Lung blocks for total-body irradiation are commonly used to reduce lung dose and prevent radiation pneumonitis. Currently, molten Cerrobend containing toxic materials, specifically lead and cadmium, is poured into molds to construct blocks. We propose a streamlined method to create 3-dimensional (3D)-printed lung block shells and fill them with tungsten ball bearings to remove lead and improve overall accuracy in the block manufacturing workflow. METHODS AND MATERIALS: 3D-printed lung block shells were automatically generated using an inhouse software, printed, and filled with 2 to 3 mm diameter tungsten ball bearings. Clinical Cerrobend blocks were compared with the physician drawn blocks as well as our proposed tungsten filled 3D-printed blocks. Physical and dosimetric comparisons were performed on a linac. Dose transmission through the Cerrobend and 3D-printed blocks were measured using point dosimetry (ion-chamber) and the on-board Electronic-Portal-Imaging-Device (EPID). Dose profiles from the EPID images were used to compute the full-width-half-maximum and to compare with the treatment-planning-system. Additionally, the coefficient-of-variation in the central 80% of full-width-half-maximum was computed and compared between Cerrobend and 3D-printed blocks. RESULTS: The geometric difference between treatment-planning-system and 3D-printed blocks was significantly lower than Cerrobend blocks (3D: -0.88 ± 2.21 mm, Cerrobend: -2.28 ± 2.40 mm, P = .0002). Dosimetrically, transmission measurements through the 3D-printed and Cerrobend blocks for both ion-chamber and EPID dosimetry were between 42% to 48%, compared with the open field. Additionally, coefficient-of-variation was significantly higher in 3D-printed blocks versus Cerrobend blocks (3D: 4.2% ± 0.6%, Cerrobend: 2.6% ± 0.7%, P < .0001). CONCLUSIONS: We designed and implemented a tungsten filled 3D-printed workflow for constructing total-body-irradiation lung blocks, which serves as an alternative to the traditional Cerrobend based workflow currently used in clinics. This workflow has the capacity of producing clinically useful lung blocks with minimal effort to facilitate the removal of toxic materials from the clinic.
RESUMO
PURPOSE: The RefleXion X1 is a novel radiotherapy machine designed for image-guided radiotherapy (IGRT) and biology-guided radiotherapy (BgRT). Its treatment planning system (TPS) generates IMRT and SBRT plans for a 6MV-FFF beam delivered axially via 50 firing positions with the couch advancing every 2.1 mm. The purpose of this work is to report the TPS commissioning results for the first clinical installation of RefleXion™ X1. METHODS: CT images of multiple phantoms were imported into the RefleXion TPS to evaluate the accuracy of data transfer, anatomical modeling, plan evaluation, and dose calculation. Comparisons were made between the X1, Eclipse™, and MIM™. Dosimetric parameters for open static fields were evaluated in water and heterogeneous slab phantoms. Representative clinical IMRT and SBRT cases were planned and verified with ion chamber, film, and ArcCHECK@ measurements. The agreement between TPS and measurements for various clinical plans was evaluated using Gamma analysis with a criterion of 3%/2 mm for ArcCHECK@ and film. End-to-end (E2E) testing was performed using anthropomorphic head and lung phantoms. RESULTS: The average difference between the TPS-reported and known HU values was -1.4 ± 6.0 HU. For static fields, the agreements between the TPS-calculated and measured PDD10 , crossline profiles, and inline profiles (FWHM) were within 1.5%, 1.3%, and 0.5 mm, respectively. Measured output factors agreed with the TPS within 1.3%. Measured and calculated dose for static fields in heterogeneous phantoms agreed within 2.5%. The ArcCHECK@ mean absolute Gamma passing rate was 96.4% ± 3.4% for TG 119 and TG 244 plans and 97.8% ± 3.6% for the 21 clinical plans. E2E film analysis showed 0.8 mm total targeting error for isocentric and 1.1 mm for off-axis treatments. CONCLUSIONS: The TPS commissioning results of the RefleXion X1 TPS were within the tolerances specified by AAPM TG 53, MPPG 5.a, TG 119, and TG 148. A subset of the commissioning tests has been identified as baseline data for an ongoing QA program.
Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Biologia , Humanos , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodosRESUMO
PURPOSE: To determine whether functional lung avoidance based on 3He magnetic resonance imaging (MRI) improves quality of life (QOL) for patients undergoing concurrent chemoradiotherapy (CCRT) for advanced non-small cell lung cancer. METHODS AND MATERIALS: Patients with stage III non-small cell lung cancer (or oligometastatic disease treated with curative intent) undergoing CCRT with at least a 10 pack-year smoking history were eligible. Patients underwent pretreatment 3He MRI to measure lung ventilation and had 2 radiation therapy (RT) plans created before randomization: a standard plan, which did not make use of the 3He MRI, and an avoidance plan, preferentially sparing well-ventilated lung. All participants were masked to assignment except the physicist responsible for exporting the selected plan. The primary end point was patient-reported QOL measured at 3-months post-RT by the FACT-L lung cancer subscale (LCS); secondary end points included other QOL metrics, toxicity, and survival outcomes. Target accrual was 64. RESULTS: Twenty-seven patients were randomized before the trial was closed due to slower-than-expected accrual, with 11 randomized to the standard arm and 16 to the avoidance arm. Baseline patient characteristics were well-balanced. At 3 months post-RT, the mean ± SD LCS scores were 17.4 ± 2.8 versus 17.3 ± 6.1 for the standard and avoidance arms, respectively (Pâ¯=â¯.485). A clinically meaningful, prespecified decline of ≥3 points in the LCS score was observed in 50% (4/8) in the standard arm and 33% (4/12) in the avoidance arm (Pâ¯=â¯.648). Two patients in each arm developed grade ≥2 radiation pneumonitis, with no grade ≥4 toxicities. CONCLUSIONS: Although this trial did not reach full accrual, QOL scores were very similar between arms. Due to the scarcity of 3He MRI, other, more commonly available methods to measure functional lung, such as 4-dimensional computed tomography ventilation mapping, may be considered in the assessment of functional lung avoidance RT, and a larger, multicenter approach would be needed to accrue sufficient patients to test such approaches.
Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Quimiorradioterapia/métodos , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/radioterapia , Masculino , Qualidade de VidaRESUMO
Purpose: The first clinical biology-guided radiation therapy (BgRT) system-RefleXionTM X1-was installed and commissioned for clinical use at our institution. This study aimed at evaluating the treatment plan quality and delivery efficiency for IMRT/SBRT cases without PET guidance. Methods: A total of 42 patient plans across 6 cancer sites (conventionally fractionated lung, head, and neck, anus, prostate, brain, and lung SBRT) planned with the EclipseTM treatment planning system (TPS) and treated with either a TrueBeam® or Trilogy® were selected for this retrospective study. For each Eclipse VMAT plan, 2 corresponding plans were generated on the X1 TPS with 10 mm jaws (X1-10mm) and 20 mm jaws (X1-20mm) using our institutional planning constraints. All clinically relevant metrics in this study, including PTV D95%, PTV D2%, Conformity Index (CI), R50, organs-at-risk (OAR) constraints, and beam-on time were analyzed and compared between 126 VMAT and RefleXion plans using paired t-tests. Results: All but 3 planning metrics were either equivalent or superior for the X1-10mm plans as compared to the Eclipse VMAT plans across all planning sites investigated. The Eclipse VMAT and X1-10mm plans generally achieved superior plan quality and sharper dose fall-off superior/inferior to targets as compared to the X1-20mm plans, however, the X1-20mm plans were still considered acceptable for treatment. On average, the required beam-on time increased by a factor of 1.6 across all sites for X1-10mm compared to X1-20mm plans. Conclusions: Clinically acceptable IMRT/SBRT treatment plans were generated with the X1 TPS for both the 10 mm and 20 mm jaw settings.
Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Biologia , Humanos , Masculino , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos RetrospectivosRESUMO
This study reports the beam commissioning results for the first clinical RefleXion Linac. METHODS: The X1 produces a 6 MV photon beam and the maximum clinical field size is 40 × 2 cm2 at source-to-axis distance of 85 cm. Treatment fields are collimated by a binary multileaf collimator (MLC) system with 64 leaves with width of 0.625 cm and y-jaw pairs to provide either a 1 or 2 cm opening. The mechanical alignment of the radiation source, the y-jaw, and MLC were checked with film and ion chambers. The beam parameters were characterized using a diode detector in a compact water tank. In-air lateral profiles and in-water percentage depth dose (PDD) were measured for beam modeling of the treatment planning system (TPS). The lateral profiles, PDDs, and output factors were acquired for field sizes from 1.25 × 1 to 40 × 2 cm2 field to verify the beam modeling. The rotational output variation and synchronicity were tested to check the gantry angle, couch motion, and gantry rotation. RESULTS: The source misalignments were 0.049 mm in y-direction, 0.66% out-of-focus in x-direction. The divergence of the beam axis was 0.36 mm with a y-jaw twist of 0.03°. Clinical off-axis treatment fields shared a common center in y-direction were within 0.03 mm. The MLC misalignment and twist were 0.57 mm and 0.15°. For all measured fields ranging from the size from 1.25 × 1 to 40 × 2 cm2 , the mean difference between measured and TPS modeled PDD at 10 cm depth was -0.3%. The mean transverse profile difference in the field core was -0.3% ± 1.1%. The full-width half maximum (FWHM) modeling was within 0.5 mm. The measured output factors agreed with TPS within 0.8%. CONCLUSIONS: This study summarizes our specific experience commissioning the first novel RefleXion linac, which may assist future users of this technology when implementing it into their own clinics.
Assuntos
Aceleradores de Partículas , Radiometria , Biologia , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , ÁguaRESUMO
PURPOSE: Our purpose was to evaluate the incidence of acute and late esophageal toxicity in patients with thoracic tumors near or abutting the esophagus treated with SABR. METHODS AND MATERIALS: Among patients with thoracic tumors treated with SABR, we identified those with tumors near or abutting the esophagus. Using the linear-quadratic model with an α/ß ratio of 10, we determined the correlation between dosimetric parameters and esophageal toxicity graded using the Common Terminology Criteria for Adverse Events, version 5.0. RESULTS: Out of 2200 patients treated with thoracic SABR, 767 patients were analyzable for esophageal dosimetry. We identified 55 patients with tumors near the esophagus (52 evaluable for esophagitis grade) and 28 with planning target volume (PTV) overlapping the esophagus. Dose gradients across the esophagus were consistently sharp. Median follow-up and overall survival were 16 and 23 months, respectively. Thirteen patients (25%) developed temporary grade 2 acute esophageal toxicity, 11 (85%) of whom had PTV overlapping the esophagus. Symptoms resolved within 1 to 3 months in 12 patients and 6 months in all patients. No grade 3 to 5 toxicity was observed. Only 3 patients (6%) developed late or persistent grade 2 dysphagia or dyspepsia of uncertain relationship to SABR. The cumulative incidence of acute esophagitis was 15% and 25% at 14 and 60 days, respectively. Acute toxicity correlated on univariate analysis with esophageal Dmax, D1cc, D2cc, Dmax/Dprescription, and whether the PTV was overlapping the esophagus. Esophageal Dmax (BED10) <62 Gy, D1cc (BED10) <48 Gy, D2cc (BED10) <43 Gy, and Dmax/Dprescription <85% were associated with <20% risk of grade 2 acute esophagitis. Only 2 local recurrences occurred. CONCLUSIONS: Although 25% of patients with tumors near the esophagus developed acute esophagitis (39% of those with PTV overlapping the esophagus), these toxicities were all grade 2 and all temporary. This suggests the safety and efficacy of thoracic SABR for tumors near or abutting the esophagus when treating with high conformity and sharp dose gradients.
Assuntos
Esofagite , Neoplasias Pulmonares , Radiocirurgia , Neoplasias Torácicas , Esofagite/etiologia , Humanos , Neoplasias Pulmonares/patologia , Radiocirurgia/métodos , Dosagem Radioterapêutica , Neoplasias Torácicas/complicaçõesRESUMO
Ultra-short echo-time (UTE) magnetic resonance imaging (MRI) provides enhanced visualization of pulmonary structural and functional abnormalities and has shown promise in phenotyping lung disease. Here, we describe the development and evaluation of a lung segmentation approach to facilitate UTE MRI methods for patient-based imaging. The proposed approach employs a k-means algorithm in kernel space for pair-wise feature clustering and imposes image domain continuous regularization, coined as continuous kernel k-means (CKKM). The high-order CKKM algorithm was simplified through upper bound relaxation and solved within an iterative continuous max-flow framework. We combined the CKKM with U-net and atlas-based approaches and comprehensively evaluated the performance on 100 images from 25 patients with asthma and bronchial pulmonary dysplasia enrolled at Robarts Research Institute (Western University, London, Canada) and Centre Hospitalier Universitaire (Sainte-Justine, Montreal, Canada). For U-net, we trained the network five times on a mixture of five different images with under-annotations and applied the model to 64 images from the two centres. We also trained a U-net on five images with full and brush annotations from one centre, and tested the model on 32 images from the other centre. For an atlas-based approach, we employed three atlas images to segment 64 target images from the two centres through straightforward atlas registration and label fusion. We applied the CKKM algorithm to the baseline U-net and atlas outputs and refined the initial segmentation through multi-volume image fusion. The integration of CKKM substantially improved baseline results and yielded, with minimal computational cost, segmentation accuracy, and precision that were greater than some state-of-the-art deep learning models and similar to experienced observer manual segmentation. This suggests that deep learning and atlas-based approaches may be utilized to segment UTE MRI datasets using relatively small training datasets with under-annotations.
Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagemRESUMO
Purpose. Radiation dose delivered to targets located near the upper-abdomen or in the thorax are significantly affected by respiratory-motion. Relatively large-margins are commonly added to compensate for this motion, limiting radiation-dose-escalation. Internal-surrogates of target motion, such as a radiofrequency (RF) tracking system, i.e. Calypso®System, are used to overcome this challenge and improve normal-tissue sparing. RF tracking systems consist of implanting transponders in the vicinity of the tumor to be tracked using radiofrequency-waves. Unfortunately, although the manufacture provides a universal quality-assurance (QA) phantom, QA-phantoms specifically for lung-applications are limited, warranting the development of alternative solutions to fulfil the tests mandated by AAPM's TG142. Accordingly, our objective was to design and develop a motion-phantom to evaluate Calypso for lung-applications that allows the Calypso®Beacons to move in different directions to better simulate truelung-motion.Methods and Materials.A Calypso lung QA-phantom was designed, and 3D-printed. The design consists of three independent arms where the transponders were attached. A pinpoint-chamber with a buildup-cap was also incorporated. A 4-axis robotic arm was programmed to drive the motion-phantom to mimic breathing. After acquiring a four-dimensional-computed-tomography (4DCT) scan of the motion-phantom, treatment-plans were generated and delivered on a Varian TrueBeam®with Calypso capabilities. Stationary and gated-treatment plans were generated and delivered to determine the dosimetric difference between gated and non-gated treatments. Portal cine-images were acquired to determine the temporal-accuracy of delivery by calculating the difference between the observed versus expected transponders locations with the known speed of the transponders' motion.Results.Dosimetric accuracy is better than the TG142 tolerance of 2%. Temporal accuracy is greater than, TG142 tolerance of 100 ms for beam-on, but less than 100 ms for beam-hold.Conclusions.The robotic QA-phantom designed and developed in this study provides an independent phantom for performing Calypso lung-QA for commissioning and acceptance testing of Calypso for lung treatments.
Assuntos
Procedimentos Cirúrgicos Robóticos , Humanos , Pulmão/diagnóstico por imagem , Neonicotinoides , Imagens de Fantasmas , Impressão Tridimensional , TiazinasRESUMO
Prior-image-based reconstruction (PIBR) methods are powerful tools for reducing radiation doses and improving the image quality of low-dose computed tomography (CT). Apart from anatomical changes, prior and current images can also have different attenuations because they originated from different scanners or from the same scanner but with different x-ray beam qualities (e.g., kVp settings, beam filters) during data acquisition. In such scenarios, with attenuation-mismatched priors, PIBR is challenging. In this work, we investigate a specific PIBR method, called statistical image reconstruction, using normal-dose image-induced nonlocal means regularization (SIR-ndiNLM), to address PIBR with such attenuation-mismatched priors and achieve quantitative low-dose CT imaging. We propose two corrective schemes for the original SIR-ndiNLM method, (1) a global histogram-matching approach and (2) a local attenuation correction approach, to account for the attenuation differences between the prior and current images in PIBR. We validate the efficacy of the proposed schemes using images acquired from dual-energy CT scanners to simulate attenuation mismatches. Meanwhile, we utilize different CT slices to simulate anatomical mismatches or changes between the prior and the current low-dose image. We observe that the original SIR-ndiNLM introduces artifacts to the reconstruction when an attenuation-mismatched prior is used. Furthermore, we find that a larger attenuation mismatch between the prior and current images results in more severe artifacts in the SIR-ndiNLM reconstruction. Our two proposed corrective schemes enable SIR-ndiNLM to effectively handle the attenuation mismatch and anatomical changes between the two images and successfully eliminate the artifacts. We demonstrate that the proposed techniques permit SIR-ndiNLM to leverage the attenuation-mismatched prior and achieve quantitative low-dose CT reconstruction from both low-flux and sparse-view data acquisitions. This work permits robust and reliable PIBR for CT data acquired using different beam settings.
Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Algoritmos , Artefatos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Modelos Estatísticos , Distribuição de Poisson , Reprodutibilidade dos Testes , Raios XRESUMO
PURPOSE: The dosimetric properties of inverse Compton (IC) x-ray sources were investigated to determine their utility for stereotactic radiation therapy. METHODS: Monte Carlo simulations were performed using the egs brachy user code of EGSnrc. Nominal IC source x-ray energies of 80 and 150 keV were considered in this work. Depth-dose and lateral dose profiles in water were calculated, as was dose enhancement in the bone. Further simulations were performed for brain and spine treatment sites. The impact of gold nanoparticle doping was also investigated for the brain treatment site. Analogous dose calculations were performed in a clinical treatment planning system using a clinical 6 MV photon beam model and were compared to the Monte Carlo simulations. RESULTS: Both 80 and 150 keV IC beams were observed to have sharp 80-20 penumbra (i.e., < 0.1 mm) with broad low-dose tails in water. For reference, the calculated penumbra for the 6 MV clinical beam was 3 mm. Maximum dose enhancement factors in bone of 3.1, 1.4, and 1.1 were observed for the 80, 150 keV, and clinical 6 MV beams, respectively. The plan quality for the single brain metastasis case was similar between the IC beams and the 6 MV beam without gold nanoparticles. As the concentration of gold within the target increased, the V12 Gy to the normal brain tissue and D max within the target volume significantly decreased and the conformity significantly improved, which resulted in superior plan quality over the clinical 6 MV beam plan. In the spine cases, the sharp penumbra and enhanced dose to bone of the IC beams produced superior plan quality (i.e., better conformity, normal tissue sparing, and spinal cord sparing) as compared to the clinical 6 MV beam plans. CONCLUSIONS: The findings from this work indicate that inverse Compton x-ray sources are well suited for stereotactic radiotherapy treatments due to their sharp penumbra and dose enhancement around high atomic number materials. Future work includes investigating the properties of intensity-modulated inverse Compton x-ray sources to improve the homogeneity within the target tissue.
Assuntos
Nanopartículas Metálicas , Radiocirurgia , Ouro , Método de Monte Carlo , Radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Raios XRESUMO
Background Hyperpolarized noble gas MRI helps measure lung ventilation, but clinical translation remains limited. Free-breathing proton MRI may help quantify lung function using existing MRI systems without contrast material and may assist in providing information about ventilation not visible to the eye or easily extracted with segmentation methods. Purpose To explore the use of deep convolutional neural networks (DCNNs) to generate synthetic MRI ventilation scans from free-breathing MRI (deep learning [DL] ventilation MRI)-derived specific ventilation maps as a surrogate of noble gas MRI and to validate this approach across a wide range of lung diseases. Materials and Methods In this secondary analysis of prospective trials, 114 paired noble gas MRI and two-dimensional free-breathing MRI scans were obtained in healthy volunteers with no history of chronic or acute respiratory disease and in study participants with a range of different obstructive lung diseases, including asthma, bronchiectasis, chronic obstructive pulmonary disease, and non-small-cell lung cancer between September 2013 and April 2018 (ClinicalTrials.gov identifiers: NCT03169673, NCT02351141, NCT02263794, NCT02282202, NCT02279329, and NCT02002052). A U-Net-based DCNN model was trained to map free-breathing proton MRI to hyperpolarized helium 3 (3He) MRI ventilation and validated using a sixfold validation. During training, the DCNN ventilation maps were compared with noble gas MRI scans using the Pearson correlation coefficient (r) and mean absolute error. DCNN ventilation images were segmented for ventilation and ventilation defects and were compared with noble gas MRI scans using the Dice similarity coefficient (DSC). Relationships were evaluated with the Spearman correlation coefficient (rS). Results One hundred fourteen study participants (mean age, 56 years ± 15 [standard deviation]; 66 women) were evaluated. As compared with 3He MRI, DCNN model ventilation maps had a mean r value of 0.87 ± 0.08. The mean DSC for DL ventilation MRI and 3He MRI ventilation was 0.91 ± 0.07. The ventilation defect percentage for DL ventilation MRI was highly correlated with 3He MRI ventilation defect percentage (rS = 0.83, P < .001, mean bias = -2.0% ± 5). Both DL ventilation MRI (rS = -0.51, P < .001) and 3He MRI (rS = -0.61, P < .001) ventilation defect percentage were correlated with the forced expiratory volume in 1 second. The DCNN model required approximately 2 hours for training and approximately 1 second to generate a ventilation map. Conclusion In participants with diverse pulmonary pathologic findings, deep convolutional neural networks generated ventilation maps from free-breathing proton MRI trained with a hyperpolarized noble-gas MRI ventilation map data set. The maps showed correlation with noble gas MRI ventilation and pulmonary function measurements. © RSNA, 2020 See also the editorial by Vogel-Claussen in this issue.
Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Pneumopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Ventilação Pulmonar , Adulto , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , PrótonsRESUMO
PURPOSE: Radiation dose delivered to targets located near the upper abdomen or thorax are significantly affected by respiratory motion, necessitating large margins, limiting dose escalation. Surrogate motion management devices, such as the Real-time Position Management (RPM™) system (Varian Medical Systems, Palo Alto, CA), are commonly used to improve normal tissue sparing. Alternative to current solutions, we have developed and evaluated the feasibility of a real-time position management system that leverages the motion data from the onboard hardware of Apple iOS devices to provide patients with visual coaching with the potential to improve the reproducibility of breathing as well as improve patient compliance and reduce treatment delivery time. METHODS AND MATERIALS: The iOS application, coined the Instant Respiratory Feedback (IRF) system, was developed in Swift (Apple Inc., Cupertino, CA) using the Core-Motion library and implemented on an Apple iPhone® devices. Operation requires an iPhone®, a three-dimensional printed arm, and a radiolucent projector screen system for feedback. Direct comparison between IRF, which leverages sensor fusion data from the iPhone®, and RPM™, an optical-based system, was performed on multiple respiratory motion phantoms and volunteers. The IRF system and RPM™ camera tracking marker were placed on the same location allowing for simultaneous data acquisition. The IRF surrogate measurement of displacement was compared to the signal trace acquired using RPM™ with univariate linear regressions and Bland-Altman analysis. RESULTS: Periodic motion shows excellent agreement between both systems, and subject motion shows good agreement during regular and irregular breathing motion. Comparison of IRF and RPM™ show very similar signal traces that were significantly related across all phantoms, including those motion with different amplitude and frequency, and subjects' waveforms (all r > 0.9, P < 0.0001). We demonstrate the feasibility of performing four-dimensional cone beam computed tomography using IRF which provided similar image quality as RPM™ when reconstructing dynamic motion phantom images. CONCLUSIONS: Feasibility of an iOS application to provide real-time respiratory motion is demonstrated. This system generated comparable signal traces to a commercially available system and offers an alternative method to monitor respiratory motion.
Assuntos
Radioterapia (Especialidade) , Algoritmos , Biorretroalimentação Psicológica , Tomografia Computadorizada Quadridimensional , Humanos , Movimento , Imagens de Fantasmas , Reprodutibilidade dos Testes , Respiração , SmartphoneRESUMO
Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel brain SRS integrated phantom was developed and validated to enable SRS QA with a single phantom to facilitate implementation of a frameless single-isocenter, multitarget SRS program. This phantom combines the independent verification of each positioning system, the Winston-Lutz, off-axis accuracy evaluation (i.e. off-axis Winston-Lutz), and the dosimetric accuracy utilizing both point dose measurements as well as film measurement, without moving the phantom. A novel 3D printed phantom, coined OneIso, was designed with a movable insert which can switch between the Winston-Lutz test target and dose measurement without moving the phantom itself. For dose verification, ten brain SRS clinical treatment plans with 10 MV flattening-filter-free beams were delivered on a Varian TrueBeam with a high-definition multileaf collimator (HD-MLC). Radiochromic film and pinpoint ion chamber comparison measurements were made between the OneIso and solid water (SW) phantom setups. For the off-axis Winston-Lutz measurements, a row of off-axis ball bearings (BBs) was integrated into the OneIso. To quantify the spatial accuracy versus distance from the isocenter, two-dimensional displacements were calculated between the planned and delivered BB locations relative to their respective MLC defined field border. OneIso and the SW phantoms agree within 1%, for both film and point dose measurements. OneIso identified a reduction in spatial accuracy further away from the isocenter. Differences increased as distance from the isocenter increased, exceeding recommended SRS accuracy tolerances at 7 cm away from the isocenter. OneIso provides a streamlined, single-setup workflow for single-isocenter multitarget frameless linac-based SRS QA. Additionally, with the ability to quantify off-axis spatial discrepancies, we can determine limitations on the maximum distance between targets to ensure a single-isocenter multitarget SRS program meets recommended guidelines.
Assuntos
Imagens de Fantasmas/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiocirurgia/normas , Algoritmos , Humanos , Aceleradores de Partículas , Impressão Tridimensional , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Dosagem RadioterapêuticaRESUMO
PURPOSE: To identify subvolumes that may predict treatment response to definitive concurrent chemoradiation therapy using parametric response mapping (PRM) of coregistered positron emission tomography (PET) and dynamic contrast-enhanced (DCE) computed tomography (CT) in locally advanced cervical carcinoma. METHODS AND MATERIALS: Pre- and midtreatment (after 23 ± 4 days of concurrent chemoradiation therapy) DCE CT and PET imaging were performed on 21 patients with cervical cancer who were enrolled in a pilot study to evaluate the prognostic value of CT perfusion for primary cervical cancer (NCT01805141). Three-dimensional coregistered maps of PET/CT standardized uptake value (SUV) and DCE CT blood flow (BF) were generated. PRM was performed using voxel-wise joint histogram analysis to classify voxels within the tumor as highly metabolic and perfused (SUVhiBFhi), highly metabolic and hypoxic (SUVhiBFlo), low metabolic activity and hypoxic (SUVloBFlo), or low metabolic activity and perfused (SUVloBFhi) tissue based on thresholds determined from population means of pretreatment PET SUV and DCE CT BF. Relationships between baseline pretreatment imaging metrics and relative changes in metabolic tumor volume (ΔMTV), calculated from before treatment and during treatment imaging, were determined using univariable and multivariable linear regression models. RESULTS: The relative volume of three PRM subvolumes significantly changed during treatment (SUVhiBFhi: P = .04; SUVhiBFlo: P = .0008; SUVloBFhi: P = .02), whereas SUVloBFlo did not (P = .9). Pretreatment PET SUVmax (r = -.58, P = .006), PET SUVmean (ρ = -.59, P = .005), DCE CT BFmean (r = -.50, P = .02), tumor volume (ρ = -.65, P = .001) and PRM SUVhiBFhi (ρ = -.59, P = .004) were negatively correlated with ΔMTV, whereas PRM SUVloBFlo was positively related to ΔMTV (r = .77, P < .0001). In a multivariable model that predicted ΔMTV, PRM SUVloBFlo, which combines both PET/CT and DCE CT, was the only significant variable (ß = 1.825, P = .03), dominating both imaging modalities independently. CONCLUSIONS: PRM was applied in locally advanced cervical carcinoma treated definitively with chemoradiation, and radioresistant subvolumes were identified that correlated with changes in MTV and predicted treatment response. Identification of these subvolumes may assist in clinical decision making to tailor therapies, such as brachytherapy, in an effort to improve patient outcomes.
Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tolerância a Radiação , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Pessoa de Meia-Idade , Razão Sinal-Ruído , Neoplasias do Colo do Útero/diagnóstico por imagemRESUMO
RATIONALE AND OBJECTIVES: In patients with severe emphysema and poor quality of life, bronchoscopic lung volume reduction (BLVR) may be considered and guided based on lobar emphysema severity. In particular, x-ray computed tomography (CT) emphysema measurements are used to identify the most diseased and the second-most diseased lobes as BLVR targets. Inhaled gas magnetic resonance imaging (MRI) also provides chronic obstructive pulmonary disease (COPD) biomarkers of lobar emphysema and ventilation abnormalities. Our objective was to retrospectively evaluate CT and MRI biomarkers of lobar emphysema and ventilation in patients with COPD eligible for BLVR. We hypothesized that MRI would provide complementary biomarkers of emphysema and ventilation that help determine the most appropriate lung lobar targets for BLVR in patients with COPD. MATERIALS AND METHODS: We retrospectively evaluated 22 BLVR-eligible patients from the Thoracic Imaging Network of Canada cohort (diffusing capacity of the lung for carbon monoxide = 37 ± 12%predicted, forced expiratory volume in 1 second = 34 ± 7%predicted, total lung capacity = 131 ± 17%predicted, and residual volume = 216 ± 36%predicted). Lobar CT emphysema, measured using a relative area of <-950 Hounsfield units (RA950) and MRI ventilation defect percent, was independently used to rank lung lobe disease severity. RESULTS: In 7 of 22 patients, there were different CT and MRI predictions of the most diseased lobe. In some patients, there were large ventilation defects in lobes not targeted by CT, indicative of a poorly ventilated lung. CT and MRI classification of the most diseased and the second-most diseased lobes showed a fair-to-moderate intermethod reliability (Cohen κ = 0.40-0.59). CONCLUSIONS: In this proof-of-concept retrospective analysis, quantitative MRI ventilation and CT emphysema measurements provided different BLVR targets in over 30% of the patients. The presence of large MRI ventilation defects in lobes next to CT-targeted lobes might also change the decision to proceed or to guide BLVR to a different lobar target.
Assuntos
Imageamento por Ressonância Magnética , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/cirurgia , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/cirurgia , Tomografia Computadorizada por Raios X , Idoso , Biomarcadores , Broncoscopia , Feminino , Volume Expiratório Forçado , Humanos , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Pneumonectomia , Estudo de Prova de Conceito , Capacidade de Difusão Pulmonar , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Enfisema Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Volume Residual , Estudos Retrospectivos , Índice de Gravidade de DoençaRESUMO
Pulmonary ventilation may be visualized and measured using hyperpolarized (3)He magnetic resonance imaging (MRI) while emphysema and its distribution can be quantified using thoracic computed tomography (CT). Our objective was to phenotype ex-smokers with COPD based on the apical-to-basal distribution of ventilation abnormalities and emphysema to better understand how these phenotypes change regionally as COPD progresses. We evaluated 100 COPD ex-smokers who provided written informed consent and underwent spirometry, CT and (3)He MRI. (3)He MRI ventilation imaging was used to quantify the ventilation defect percent (VDP) for whole-lung and individual lung lobes. Regional VDP was used to generate the apical-lung (AL)-to-basal-lung (BL) difference (ΔVDP); a positive ΔVDP indicated AL-predominant and negative ΔVDP indicated BL-predominant ventilation defects. Emphysema was quantified using the relative-area-of-the-lung ≤-950HU (RA950) of the CT density histogram for whole-lung and individual lung lobes. The AL-to-BL RA950 difference (ΔRA950) was generated with a positive ΔRA950 indicating AL-predominant emphysema and a negative ΔRA950 indicating BL-predominant emphysema. Seventy-two ex-smokers reported BL-predominant MRI ventilation defects and 71 reported AL-predominant CT emphysema. BL-predominant ventilation defects (AL/BL: GOLD I = 18%/82%, GOLD II = 24%/76%) and AL-predominant emphysema (AL/BL: GOLD I = 84%/16%, GOLD II = 72%/28%) were the major phenotypes in mild-moderate COPD. In severe COPD there was a more uniform distribution for ventilation defects (AL/BL: GOLD III = 40%/60%, GOLD IV = 43%/57%) and emphysema (AL/BL: GOLD III = 64%/36%, GOLD IV = 43%/57%). Basal-lung ventilation defects predominated in mild-moderate GOLD grades, and a more homogeneous distribution of ventilation defects was observed in more advanced grade COPD; these differences suggest that over time, regional ventilation abnormalities become more homogenously distributed during disease progression.
Assuntos
Enfisema/diagnóstico por imagem , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Volume Expiratório Forçado , Hélio , Humanos , Isótopos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Fenótipo , Pletismografia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Ventilação Pulmonar , Volume Residual , Abandono do Hábito de FumarRESUMO
PURPOSE: To directly compare magnetic resonance (MR) imaging and computed tomography (CT) parametric response map (PRM) measurements of gas trapping and emphysema in ex-smokers both with and without chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS: Participants provided written informed consent to a protocol that was approved by a local research ethics board and Health Canada and was compliant with the HIPAA (Institutional Review Board Reg. #00000940). The prospectively planned study was performed from March 2014 to December 2014 and included 58 ex-smokers (mean age, 73 years ± 9) with (n = 32; mean age, 74 years ± 7) and without (n = 26; mean age, 70 years ± 11) COPD. MR imaging (at functional residual capacity plus 1 L), CT (at full inspiration and expiration), and spirometry or plethysmography were performed during a 2-hour visit to generate ventilation defect percent (VDP), apparent diffusion coefficient (ADC), and PRM gas trapping and emphysema measurements. The relationships between pulmonary function and imaging measurements were determined with analysis of variance (ANOVA), Holm-Bonferroni corrected Pearson correlations, multivariate regression modeling, and the spatial overlap coefficient (SOC). RESULTS: VDP, ADC, and PRM gas trapping and emphysema (ANOVA, P < .001) measurements were significantly different in healthy ex-smokers than they were in ex-smokers with COPD. In all ex-smokers, VDP was correlated with PRM gas trapping (r = 0.58, P < .001) and with PRM emphysema (r = 0.68, P < .001). VDP was also significantly correlated with PRM in ex-smokers with COPD (gas trapping: r = 0.47 and P = .03; emphysema: r = 0.62 and P < .001) but not in healthy ex-smokers. In a multivariate model that predicted PRM gas trapping, the forced expiratory volume in 1 second normalized to the forced vital capacity (standardized coefficients [ßS] = -0.69, P = .001) and airway wall area percent (ßS = -0.22, P = .02) were significant predictors. PRM emphysema was predicted by the diffusing capacity for carbon monoxide (ßS = -0.29, P = .03) and VDP (ßS = 0.41, P = .001). Helium 3 ADC values were significantly elevated in PRM gas-trapping regions (P < .001). The spatial relationship for ventilation defects was significantly greater with PRM gas trapping than with PRM emphysema in patients with mild (for gas trapping, SOC = 36% ± 28; for emphysema, SOC = 1% ± 2; P = .001) and moderate (for gas trapping, SOC = 34% ± 28; for emphysema, SOC = 7% ± 15; P = .006) COPD. For severe COPD, the spatial relationship for ventilation defects with PRM emphysema (SOC = 64% ± 30) was significantly greater than that for PRM gas trapping (SOC = 36% ± 18; P = .01). CONCLUSION: In all ex-smokers, ADC values were significantly elevated in regions of PRM gas trapping, and VDP was quantitatively and spatially related to both PRM gas trapping and PRM emphysema. In patients with mild to moderate COPD, VDP was related to PRM gas trapping, whereas in patients with severe COPD, VDP correlated with both PRM gas trapping and PRM emphysema.