Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Children (Basel) ; 9(5)2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35626853

RESUMO

Cor triatriatum dexter (CTD) is an extremely uncommon and underreported congenital cardiac anomaly in which the persistence of the embryonic right venous valve separates the right atrium into two chambers with varying degrees of obstruction to antegrade flow and variable degree of right to left shunt at atrial level. Depending on the size of the valves, clinical manifestations vary from absence of symptoms to severe hypoxia, requiring urgent surgical correction. We herein describe the diagnostic difficulties in a case of neonatal CTD, who developed increasingly severe and unresponsive cyanosis, first interpreted as postnatal maladjustment with pulmonary hypertension. The failure to respond to oxygen and pulmonary vasodilators led us to reconsider a different diagnosis. The use of contrast echocardiography improved the diagnostic performance of transthoracic echocardiogram (TTE) and revealed a massive right-to-left shunt secondary to the presence of an atrial membrane that required urgent surgery.

2.
J Ultrasound Med ; 41(5): 1187-1194, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34423855

RESUMO

OBJECTIVES: To assess reproducibility and accuracy of left ventricular output (LVO) quantifications in neonates, when left ventricular outflow tract diameter (LVOTD) was measured at the hinges of the aortic valve (AV), at the aortic sinus (AS), and at the sinotubular junction (STJ). METHODS: This was an observational study. In the first cohort of very preterm neonates, we assessed intraobserver and interobserver repeatability of LVOTD measured at the AV, AS, and STJ and of the corresponding LVO. In the second cohort of older neonates, we compared paired LVO measurements by echo and magnetic resonance imaging (MRI). RESULTS: In the first cohort of 48 neonates, mean (standard deviation) weight and age at scan were 1046 (302) g and 28.1 (2.7) weeks. Interobserver bias (95% limits of agreement [LOA]) for LVOTD at the AV, AS, and STJ was 0 (-0.3 to 0.3) mm, 0 (-0.7 to 0.7) mm, and 0 (-0.8 to 0.7) mm, respectively. Interobserver bias (95% LOA) for the corresponding LVO was -1.3 (-31 to 33) ml/kg/min, -0.5 (-88 to 87) ml/kg/min, and -7.2 (-83 to 69) ml/kg/min, respectively. In the second cohort of 10 neonates, median (range) weight and age at scan were 1942 (970-3640) g and 37.2 (31.7-39.8) weeks. LVO measured at the AV showed stronger agreement with MRI: bias (LOA) -10.6 (-74 to 52) ml/kg/min, compared to LVO measured at AS and STJ: 194 (-0.5 to 388) ml/kg/min and 43 (-72 to 159) ml/kg/min respectively. CONCLUSIONS: Reproducibility and accuracy of LVO quantification by echo were better when aortic diameter was measured at AV.


Assuntos
Ecocardiografia , Ventrículos do Coração , Valva Aórtica/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Recém-Nascido , Variações Dependentes do Observador , Reprodutibilidade dos Testes
3.
J Pediatr ; 166(6): 1488-92, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25882876

RESUMO

OBJECTIVE: To assess whether the duration and magnitude of the shunt with patent ductus arteriosus (PDA) are related to a higher incidence of bronchopulmonary dysplasia (BPD) or death. STUDY DESIGN: A total of 242 infants ≤ 28 weeks gestational age were evaluated retrospectively between 2007 and 2012; 105 (43.3%) developed BPD or died (group 1) and 137 (56.6%) did not (group 2). A review of all echocardiographic evaluations performed from birth up to 36 weeks of postconceptional age or final ductal closure was carried out, to detect the presence of PDA, and estimate the severity of ductal shunt through the "PDA staging system" proposed by McNamara and Sehgal. RESULTS: Group 1 presented with a hemodynamically significant ductus arteriosus (DA) (E3 and/or E4-PDA) for a longer period of time vs group 2: 4.8 vs 2.3 days, respectively (P < .001). Persistence of a nonsignificant DA (E2) was not associated with development of BPD (P = .16). Each week of a hemodynamically significant DA represented an added risk for BPD (OR 1.7), and the duration of a small, nonsignificant DA (E2) did not. Surgical ligation of PDA itself was not found to be an independent risk factor for BPD. In the subgroup of patients who received ligation, a later ligation (33 vs 23 days) and a prolonged PDA were the only factors associated to BPD or death. CONCLUSIONS: A shared scoring system of the severity of ductal shunt is helpful to correctly evaluate the association between PDA morbidities, to compare scientific studies, and to guide treatment.


Assuntos
Displasia Broncopulmonar/etiologia , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/fisiopatologia , Hemodinâmica , Displasia Broncopulmonar/epidemiologia , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA