Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Neonatal Screen ; 9(1)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36975853

RESUMO

In 1963, Robert Guthrie's pioneering work developing a bacterial inhibition assay to measure phenylalanine in dried blood spots, provided the means for whole-population screening to detect phenylketonuria in the USA. In the following decades, NBS became firmly established as a part of public health in developed countries. Technological advances allowed for the addition of new disorders into routine programmes and thereby resulted in a paradigm shift. Today, technological advances in immunological methods, tandem mass spectrometry, PCR techniques, DNA sequencing for mutational variant analysis, ultra-high performance liquid chromatography (UPLC), iso-electric focusing, and digital microfluidics are employed in the NBS laboratory to detect more than 60 disorders. In this review, we will provide the current state of methodological advances that have been introduced into NBS. Particularly, 'second-tier' methods have significantly improved both the specificity and sensitivity of testing. We will also present how proteomic and metabolomic techniques can potentially improve screening strategies to reduce the number of false-positive results and improve the prediction of pathogenicity. Additionally, we discuss the application of complex, multiparameter statistical procedures that use large datasets and statistical algorithms to improve the predictive outcomes of tests. Future developments, utilizing genomic techniques, are also likely to play an increasingly important role, possibly combined with artificial intelligence (AI)-driven software. We will consider the balance required to harness the potential of these new advances whilst maintaining the benefits and reducing the risks for harm associated with all screening.

2.
Clin Chem Lab Med ; 61(2): 302-310, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36395058

RESUMO

OBJECTIVES: During 2020, the UK's Department of Health and Social Care (DHSC) established the Moonshot programme to fund various diagnostic approaches for the detection of SARS-CoV-2, the pathogen behind the COVID-19 pandemic. Mass spectrometry was one of the technologies proposed to increase testing capacity. METHODS: Moonshot funded a multi-phase development programme, bringing together experts from academia, industry and the NHS to develop a state-of-the-art targeted protein assay utilising enrichment and liquid chromatography tandem mass spectrometry (LC-MS/MS) to capture and detect low levels of tryptic peptides derived from SARS-CoV-2 virus. The assay relies on detection of target peptides, ADETQALPQRK (ADE) and AYNVTQAFGR (AYN), derived from the nucleocapsid protein of SARS-CoV-2, measurement of which allowed the specific, sensitive, and robust detection of the virus from nasopharyngeal (NP) swabs. The diagnostic sensitivity and specificity of LC-MS/MS was compared with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) via a prospective study. RESULTS: Analysis of NP swabs (n=361) with a median RT-qPCR quantification cycle (Cq) of 27 (range 16.7-39.1) demonstrated diagnostic sensitivity of 92.4% (87.4-95.5), specificity of 97.4% (94.0-98.9) and near total concordance with RT-qPCR (Cohen's Kappa 0.90). Excluding Cq>32 samples, sensitivity was 97.9% (94.1-99.3), specificity 97.4% (94.0-98.9) and Cohen's Kappa 0.95. CONCLUSIONS: This unique collaboration between academia, industry and the NHS enabled development, translation, and validation of a SARS-CoV-2 method in NP swabs to be achieved in 5 months. This pilot provides a model and pipeline for future accelerated development and implementation of LC-MS/MS protein/peptide assays into the routine clinical laboratory.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Pandemias , COVID-19/diagnóstico , Teste para COVID-19 , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Estudos Prospectivos , Técnicas de Laboratório Clínico/métodos , Sensibilidade e Especificidade , Peptídeos
3.
BMJ Open ; 10(12): e044755, 2020 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-33310815

RESUMO

OBJECTIVE: To explore current communication practices for positive newborn screening results from the newborn bloodspot screening (NBS) laboratory to clinicians to highlight differences, understand how the pathways are implemented in practice, identify barriers and facilitators and make recommendations for future practice and research. DESIGN: A qualitative exploratory design was employed using semi-structured interviews. SETTING: Thirteen NBS laboratories in England. PARTICIPANTS: Seventy-one clinicians; 22 NBS laboratory staff across 13 laboratories and 49 members of relevant clinical teams were interviewed. RESULTS: Assurance of quality and consistency was a priority for all NBS laboratories. Findings indicated variation in approaches to communicating positive NBS results from laboratories to clinical teams. This was particularly evident for congenital hypothyroidism and was largely influenced by local arrangements, resources and the fact individual laboratories had detailed standard operating procedures for how they work. Obtaining feedback from clinical teams to the laboratory after the child had been seen could be challenging and time-consuming for those involved. Pathways for communicating carrier results for cystic fibrosis and sickle cell disease could be ambiguous and inconsistent which in turn could hamper the laboratories efforts to obtain timely feedback regarding whether or not the result had been communicated to the family. Communication pathways for positive NBS results between laboratories and clinical teams could therefore be time-consuming and resource-intensive. CONCLUSION: The importance placed on ensuring positive NBS results were communicated effectively and in a timely fashion from the laboratory to the clinical team was evident from all participants. However, variation existed in terms of the processes used to report positive NBS results to clinical teams and the people involved. Variant practice identified may reflect local needs, but more often reflected local resources and a more consistent 'best practice' approach is required, not just in the UK but perhaps globally. TRIAL REGISTRATION NUMBER: ISRCTN15330120.


Assuntos
Anemia Falciforme , Fibrose Cística , Triagem Neonatal , Anemia Falciforme/diagnóstico , Comunicação , Fibrose Cística/diagnóstico , Inglaterra , Estudos de Avaliação como Assunto , Humanos , Recém-Nascido
4.
Clin Chem Lab Med ; 58(5): 758-768, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-31622240

RESUMO

Background Quantification of plasma amino acids is key to the diagnosis of inherited defects of amino acid synthesis, catabolism and transport, many of which present as clinical emergencies. The utility of this test is limited by the long analysis time and subsequent inability of laboratories to provide results in real-time. Traditionally, analysis has been performed by ion exchange chromatography (IEC) but recently there has been a move towards liquid chromatography tandem mass spectrometry (LC-MS/MS) which provides the potential for faster analysis. However, the necessity to derivatise the sample and/or utilise an ion-pair reagent, combined with lack of commercially available stable isotope internal standards (IS) has prevented laboratories fully exploiting the benefits of this methodology. We describe an underivatised LC-MS/MS method enabling patient results to be reported with an improved turnaround time (<1 h). Methods Methanolic IS was added to plasma (10 µL) to precipitate protein. Following centrifugation amino acids were analysed by LC-MS/MS using selected reaction monitoring (SRM) for each analyte and corresponding IS. Results Patient samples (n = 57) and external quality assessment (EQA) material (n = 11) were analysed and results compared with IEC. Comparable accuracy and precision were obtained with 15-min analysis time. Conclusions This method enables the analysis of a clinically comprehensive amino acid profile without the need for derivatisation/ion-pair reagents and benefitting from improved analytical quantitation through multipoint calibration and use of stable isotope IS. The analysis time is fast in comparison to IEC, improves efficiency of laboratory workflow and enables stat analysis of clinically urgent samples.


Assuntos
Aminoácidos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Aminoácidos/isolamento & purificação , Aminoácidos/normas , Precipitação Química , Cromatografia Líquida de Alta Pressão/normas , Cromatografia por Troca Iônica , Homocistinúria/patologia , Humanos , Marcação por Isótopo , Doença da Urina de Xarope de Bordo/patologia , Doença da Deficiência de Ornitina Carbomoiltransferase/patologia , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Estudos de Validação como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA