Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Neurointerv Surg ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38503510

RESUMO

BACKGROUND: The frequency of clinically symptomatic and asymptomatic diffusion-weighted imaging (DWI) hyperintense lesions and their correlation with the transradial artery (TRA) approach is unclear. OBJECTIVE: To assess the frequency of abnormal diffusion restriction foci on DWI following cerebral angiography (digital subtraction angiography (DSA)) with the TRA or transfemoral artery (TFA) approach and identify predictors of DWI restriction foci. METHODS: We analysed data from consecutive diagnostic cerebral angiograms obtained between January 2021 and October 2023 at a single tertiary center. MRI DWI was performed 2 hours after DSA. Patients underwent neurological assessment periprocedurally, as well as prior to discharge. RESULTS: 500 patients were analysed; 277 (55%) procedures were performed via TRA and 223 (45%) via TFA. Overall, 74 (14.8%) patients had abnormal findings in the postprocedure MRI DWI. A higher incidence of positive DWI findings was noted in the TRA group, with 46 (16.6%) patients, compared with 28 (12.6%) in the TFA group (P=0.21). Symptomatic events occurred in seven (2.5%) of the TRA group and in two (0.9%) of the TFA cohort (P=0.31). At 60 days, the neurological deficit rate was one (0.4%) for the TRA group and one (0.4%) for the TFA group. Procedure time was the only significant predictor of DWI restriction (OR=1.04 per minute; P=0.0001). CONCLUSION: Although there were more symptomatic or asymptomatic embolic events with TRA than with the TFA approach following elective cerebral angiography, this was not significantly different. We recommend the choice of vascular access based on patient anatomy and characteristics, aimed at improving care through enhanced safety.

2.
J Neurointerv Surg ; 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38253378

RESUMO

BACKGROUND: Half of patients who achieve successful recanalization following endovascular thrombectomy (EVT) for acute ischemic stroke experience poor functional outcome. We aim to investigate whether the use of adjunctive intra-arterial antithrombotic therapy (AAT) during EVT is safe and efficacious compared with standard therapy (ST) of EVT with or without prior intravenous thrombolysis. METHODS: Electronic databases were searched (PubMed/MEDLINE, Embase, Cochrane Library) from 2010 until October 2023. Data were pooled using a random-effects model and reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Risk of bias was assessed using ROBINS-I and ROB-2. The primary outcome was functional independence (modified Rankin Scale (mRS) 0-2) at 3 months. Secondary outcomes were successful recanalization (modified Thrombolysis In Cerebral Infarction (TICI) 2b-3), symptomatic intracranial hemorrhage (sICH), and 90-day mortality. RESULTS: 41 randomized and non-randomized studies met the eligibility criteria. Overall, 15 316 patients were included; 3296 patients were treated with AAT during EVT and 12 020 were treated with ST alone. Compared with ST, patients treated with AAT demonstrated higher odds of functional independence (46.5% AAT vs 42.6% ST; OR 1.22, 95% CI 1.07 to 1.40, P=0.004, I2=48%) and a lower likelihood of 90-day mortality (OR 0.71, 95% CI 0.61 to 0.83, P<0.0001, I2=20%). The rates of sICH (OR 1.00, 95% CI 0.82 to 1.22,P=0.97, I2=13%) and successful recanalization (OR 1.09, 95% CI 0.84 to 1.42, P=0.52, I2=76%) were not significantly different. CONCLUSION: The use of AAT during EVT may improve functional outcomes and reduce mortality rates compared with ST alone, without an increased risk of sICH. These findings should be interpreted with caution pending the results from ongoing phase III trials to establish the efficacy and safety of AAT during EVT.

3.
J Neurointerv Surg ; 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38171607

RESUMO

BACKGROUND: The Pipeline Embolization Device has proven to be a safe and effective device for the treatment of intracranial aneurysms. The Pipeline Vantage Flow Diverter (PVFD) with Shield Technology is the new fourth generation of this implant, with modifications made compared to previous iterations. We aimed to evaluate the mechanical properties and clinical safety and efficacy of this device. METHODS: Vanguard is a single arm, single center, prospective study. Between April 2021 and April 2023, all consecutive patients with an unruptured aneurysm treated with Pipeline Vantage flow-diverting stents were included. There were no aneurysm size or location exclusion criteria. Safety (neurological serious adverse events) and efficacy (device deployment and aneurysm occlusion) were independently reviewed. Imaging follow-up data, and immediate, early (<30 days), and delayed (>30 days) neurological serious adverse events were independently assessed. RESULTS: 101 consecutive patients with a total of 115 aneurysms were included. The aneurysms were situated in the anterior (90.4%) or posterior (9.6%) circulations. A total of 124 devices were implanted. The deployment success rate was 100%. In four (4.0%) cases post-deployment angioplasty was required to optimize device wall apposition. Occlusion rates at 1 month were 54.7%, at 3 months 72.1%, and at 6 months 81.7%. Morbidity and mortality were 4.9% and 0%, respectively, at 6 months. Eight cases (6.9%) demonstrated in-stent stenosis, four of which had 'fish mouth' deformity. CONCLUSION: Initial results of the new generation PVFD for unruptured intracranial aneurysm treatment demonstrate overall satisfactory device performance, safety profile, and effectiveness.

5.
J Neurointerv Surg ; 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37355257

RESUMO

BACKGROUND: Physician variablity in preoperative planning of endovascular implant deployment and associated inaccuracies have not been documented. This study aimed to quantify the variability in accuracy of physician flow diverter (FD) planning and directly compares it with PreSize Neurovascular (Oxford Heartbeat Ltd) software simulations. METHODS: Eight experienced neurointerventionalists (NIs), blinded to procedural details, were provided with preoperative 3D rotational angiography (3D-RA) volumetric data along with images annotated with the distal landing location of a deployed Surpass Evolve (Stryker Neurovascular) FD from 51 patient cases. NIs were asked to perform a planning routine reflecting their normal practice and estimate the stent's proximal landing using volumetric data and the labeled dimensions of the FD used. Equivalent deployed length estimation was performed using PreSize software. NI- and software-estimated lengths were compared with postprocedural observed deployed stent length (control) using Bland-Altman plots. NI assessment agreement was assessed with the intraclass correlation coefficient (ICC). RESULTS: The mean accuracy of NI-estimated deployed FD length was 81% (±15%) versus PreSize's accuracy of 95% (±4%), demonstrating significantly higher accuracy for the software (p<0.001). The mean absolute error between estimated and control lengths was 4 mm (±3.5 mm, range 0.03-30.2 mm) for NIs and 1 mm (±0.9 mm, range 0.01-3.9 mm) for PreSize. No discernable trends in accuracy among NIs or across vasculature and aneurysm morphology (size, vessel diameter, tortuousity) were found. CONCLUSIONS: The study quantified experienced physicians' significant variablity in predicting an FD deployment with current planning approaches. In comparison, PreSize-simulated FD deployment was consistently more accurate and reliable, demonstrating its potential to improve standard of practice.

6.
J Neurointerv Surg ; 15(7): 723-727, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35868855

RESUMO

BACKGROUND: The radial artery approach has become popular as a 'radial first' strategy for arterial access in neuroangiography and neurointerventions. Recent studies have shown that transradial arterial access (TRA) for cerebral angiography has been associated with reduced access site complication rates and improved patient satisfaction compared with transfemoral access (TFA). The goal of this study was to evaluate the presence of abnormal MRI diffusion weighted imaging (DWI) foci following DSA and correlate their frequency with TRA or TFA. METHODS: We prospective analyzed 200 consecutive adult DSAs performed from January 2021 to January 2022, at a single tertiary center. RESULTS: Of the 200 consecutive diagnostic cerebral angiograms, 51% were performed via TRA and 49% were performed via TFA. Of the TRA cerebral angiograms, 17.5% demonstrated at least one hyperintense focus on MRI DWI. Of the TFA procedures, 5.2% were considered positive. One patient (0.5%) in the TRA group experienced a minor neurologic deficit postoperatively that had not completely resolved at 90 days after the procedure and no neurologic deficits occurred in the TFA group. CONCLUSIONS: Despite the proven benefit of TRA over TFA in neurointervention, the number of MRI DWI restriction foci were significantly more frequent during cerebral angiography when TRA was selected. Although the number of clinically symptomatic events were minimal, the widespread use of the technique may become clinically relevant. Further studies contrasting the TRA and TFA techniques will be beneficial for cerebral angiography.


Assuntos
Cateterismo Periférico , Artéria Femoral , Adulto , Humanos , Angiografia Cerebral/métodos , Estudos Prospectivos , Artéria Femoral/diagnóstico por imagem , Artéria Radial/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Resultado do Tratamento , Estudos Retrospectivos , Cateterismo Periférico/métodos
7.
J Med Imaging Radiat Oncol ; 62(1): 39-42, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28508466

RESUMO

INTRODUCTION: More than half of the patients with an impalpable malignant breast lesion have a mammographically detected and imaged-guided localisation, which can be technically challenging for the breast surgeon. Specimen imaging is used to confirm successful excision of the localised index lesion and has improved the operating list efficiency resulting in a higher number of excisions per surgical list. The aim of this study was to evaluate whether introducing IDSM (intra-operative digital specimen mammography) saved operation time for localised breast surgery. METHODS: A single-centre retrospective review was undertaken to compare the operation time (from incision to wound closure) taken for excision of 114 consecutive image-guided localised impalpable breast lesions, performed using departmental specimen radiography (DSR), 6 months prior to the introduction of IDSM (Hologic, Trident® ) in March 2013, with the theatre time taken for excision of 121 consecutive image-guided localised impalpable breast lesions in the 6 months following introduction of IDSM. RESULTS: There was no significant difference in mean surgical time, which were 47.8 (±27.3) minutes in the CSR group and 48.8 (±25.7) minutes in the IDSM group. CONCLUSION: We were expecting to confirm a reduction in theatre time with the introduction of IDSM. Surprisingly, no difference in operating times was demonstrated. Factors that influenced the impact of IDSM included the proximity of the imaging department to the operating theatre.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mamografia/métodos , Mastectomia/métodos , Duração da Cirurgia , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA