Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
JACC Cardiovasc Interv ; 16(12): 1437-1447, 2023 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-37380225

RESUMO

Mitral regurgitation is the most common valvular disease and is estimated to affect over 5 million Americans. Real-world data collection contributes to safety and effectiveness evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, and clinical best practice research. We aimed to establish a minimum core data set in mitral interventions to promote efficient, reusable real-world data collection for all of these purposes. Two expert task forces separately evaluated and reconciled a list of candidate elements derived from: 1) 2 ongoing transcatheter mitral trials; and 2) a systemic literature review of high-impact mitral trials and U.S multicenter, multidevice registries. From 703 unique data elements considered, unanimous consensus agreement was achieved on 127 "core" data elements, with the most common reasons for exclusion from the minimum core data set being burden or difficulty in accurate assessment (41.2%), duplicative information (25.0%), and low likelihood of affecting outcomes (19.6%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established and implemented into the national Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapies Registry 127 interoperable, reusable core data elements to support more efficient, consistent, and informative transcatheter mitral device evidence for regulatory submissions, safety surveillance, best practice development, and hospital quality assessments.


Assuntos
Cardiologia , Medicare , Idoso , Humanos , Estados Unidos , Resultado do Tratamento , Catéteres , Centers for Medicare and Medicaid Services, U.S. , Estudos Multicêntricos como Assunto
2.
Curr Gastroenterol Rep ; 25(6): 115-121, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37204654

RESUMO

PURPOSE OF REVIEW: The aim of this paper is to review and assess the appropriateness of eradication of nondysplastic Barrett's esophagus. Dysplasia in Barrett's esophagus is a known predictor for the development of esophageal cancer, and is currently the best marker in aiding the decision making regarding treatment options. Current data supports endoscopic eradication therapy for most patients with dysplastic Barrett's. The controversy, however, lies in the management of nondysplastic Barrett's and when to recommend ablation versus ongoing surveillance. RECENT FINDINGS: There have been increasing efforts to identify factors that can help predict which patients with nondysplastic Barrett's esophagus are at increased risk for cancer progression, and to quantify that risk. While there is currently varying data and literature supporting this, a more objective risk score is likely to soon become available and accepted, in an effort to differentiate between low and high risk nondysplastic Barrett's, and better aid in decision making regarding surveillance versus endoscopic eradication. This article reviews the current data on Barrett's esophagus and its risk for cancer progression, and it outlines several factors which impact progression that should be considered in the management approach to nondysplastic Barrett's esophagus.


Assuntos
Adenocarcinoma , Esôfago de Barrett , Neoplasias Esofágicas , Humanos , Esôfago de Barrett/complicações , Esôfago de Barrett/cirurgia , Adenocarcinoma/etiologia , Esofagoscopia , Neoplasias Esofágicas/etiologia , Fatores de Risco
3.
Am J Respir Crit Care Med ; 208(1): 79-97, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37219236

RESUMO

Rationale: Immature control of breathing is associated with apnea, periodic breathing, intermittent hypoxemia, and bradycardia in extremely preterm infants. However, it is not clear if such events independently predict worse respiratory outcome. Objectives: To determine if analysis of cardiorespiratory monitoring data can predict unfavorable respiratory outcomes at 40 weeks postmenstrual age (PMA) and other outcomes, such as bronchopulmonary dysplasia at 36 weeks PMA. Methods: The Prematurity-related Ventilatory Control (Pre-Vent) study was an observational multicenter prospective cohort study including infants born at <29 weeks of gestation with continuous cardiorespiratory monitoring. The primary outcome was either "favorable" (alive and previously discharged or inpatient and off respiratory medications/O2/support at 40 wk PMA) or "unfavorable" (either deceased or inpatient/previously discharged on respiratory medications/O2/support at 40 wk PMA). Measurements and Main Results: A total of 717 infants were evaluated (median birth weight, 850 g; gestation, 26.4 wk), 53.7% of whom had a favorable outcome and 46.3% of whom had an unfavorable outcome. Physiologic data predicted unfavorable outcome, with accuracy improving with advancing age (area under the curve, 0.79 at Day 7, 0.85 at Day 28 and 32 wk PMA). The physiologic variable that contributed most to prediction was intermittent hypoxemia with oxygen saturation as measured by pulse oximetry <90%. Models with clinical data alone or combining physiologic and clinical data also had good accuracy, with areas under the curve of 0.84-0.85 at Days 7 and 14 and 0.86-0.88 at Day 28 and 32 weeks PMA. Intermittent hypoxemia with oxygen saturation as measured by pulse oximetry <80% was the major physiologic predictor of severe bronchopulmonary dysplasia and death or mechanical ventilation at 40 weeks PMA. Conclusions: Physiologic data are independently associated with unfavorable respiratory outcome in extremely preterm infants.


Assuntos
Displasia Broncopulmonar , Lactente Extremamente Prematuro , Lactente , Recém-Nascido , Humanos , Estudos Prospectivos , Respiração Artificial , Hipóxia
4.
Nat Commun ; 13(1): 7732, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36513638

RESUMO

Chromosome segregation is initiated by cohesin degradation, which is driven by anaphase-promoting complex/cyclosome (APC/C). Chromosome cohesin is removed by activated separase, with the degradation of securin and cyclinB1. Dynamin-related protein 1 (DRP1), a component of the mitochondrial fission machinery, is related to cyclin dynamics in mitosis progression. Here, we show that DRP1 is recruited to the kinetochore by centromeric Centromere protein F (CENP-F) after nuclear envelope breakdown in mouse oocytes. Loss of DRP1 during prometaphase leads to premature cohesin degradation and chromosome segregation. Importantly, acute DRP1 depletion activates separase by initiating cyclinB1 and securin degradation during the metaphase-to-anaphase transition. Finally, we demonstrate that DRP1 is bound to APC2 to restrain the E3 ligase activity of APC/C. In conclusion, DRP1 is a CENP-F-dependent atypical spindle assembly checkpoint (SAC) protein that modulates metaphase-to-anaphase transition by controlling APC/C activity during meiosis I in oocytes.


Assuntos
Segregação de Cromossomos , Meiose , Animais , Camundongos , Ciclossomo-Complexo Promotor de Anáfase/metabolismo , Proteínas de Ciclo Celular/metabolismo , Dinaminas/metabolismo , Cinetocoros/metabolismo , Oócitos/metabolismo , Securina/genética , Securina/metabolismo , Separase/metabolismo
5.
Sci Adv ; 8(24): eabl8070, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35704569

RESUMO

Eggs contain about 200,000 mitochondria that generate adenosine triphosphate and metabolites essential for oocyte development. Mitochondria also integrate metabolism and transcription via metabolites that regulate epigenetic modifiers, but there is no direct evidence linking oocyte mitochondrial function to the maternal epigenome and subsequent embryo development. Here, we have disrupted oocyte mitochondrial function via deletion of the mitochondrial fission factor Drp1. Fission-deficient oocytes exhibit a high frequency of failure in peri- and postimplantation development. This is associated with altered mitochondrial function, changes in the oocyte transcriptome and proteome, altered subcortical maternal complex, and a decrease in oocyte DNA methylation and H3K27me3. Transplanting pronuclei of fertilized Drp1 knockout oocytes to normal ooplasm fails to rescue embryonic lethality. We conclude that mitochondrial function plays a role in establishing the maternal epigenome, with serious consequences for embryo development.


Assuntos
Desenvolvimento Embrionário , Oócitos , Citoplasma/metabolismo , Dinaminas/genética , Dinaminas/metabolismo , Desenvolvimento Embrionário/genética , Feminino , Humanos , Mitocôndrias/metabolismo , Oócitos/metabolismo , Gravidez
6.
Ann Thorac Surg ; 113(5): 1730-1742, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35367049

RESUMO

Transcatheter aortic valve replacement (TAVR) is the standard of care for severe, symptomatic aortic stenosis. Real-world TAVR data collection contributes to benefit/risk assessment and safety evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, as well as clinical research and real-world implementation through appropriate use criteria. The essential minimum core dataset for these purposes has not previously been defined but is necessary to promote efficient, reusable real-world data collection supporting quality, regulatory, and clinical applications. The authors performed a systematic review of the published research for high-impact TAVR studies and U.S. multicenter, multidevice registries. Two expert task forces, one from the Predictable and Sustainable Implementation of National Cardiovascular Registries/Heart Valve Collaboratory and another from The Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry convened separately and then met to reconcile a final list of essential data elements. From 276 unique data elements considered, unanimous consensus agreement was achieved on 132 "core" data elements, with the most common reasons for exclusion from the minimum core dataset being burden or difficulty in accurate assessment (36.9%), duplicative information (33.3%), and low likelihood of affecting outcomes (10.7%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established 132 interoperable, reusable essential core data elements essential to supporting more efficient, consistent, and informative TAVR device evidence for regulatory submissions, safety surveillance, best practice, and hospital quality assessments.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Medicare , Estudos Multicêntricos como Assunto , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
7.
J Am Heart Assoc ; 11(6): e023848, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35243902

RESUMO

Background The practice pattern and outcome of medical devices following their regulatory approval may differ by country. The aim of this study is to compare postapproval national clinical registry data on transcatheter aortic valve replacement between the United States and Japan on patient characteristics, periprocedural outcomes, and the variability of outcomes as a part of a partnership program (Harmonization-by-Doing) between the 2 countries. Methods and Results The patient-level data were extracted from the US Society of Thoracic Surgeons /American College of Cardiology Transcatheter Valve Therapy (STS/ACC TVT) and the J-TVT (Japanese Transcatheter Valvular Therapy) registry, respectively, to analyze transcatheter aortic valve replacement outcomes between 2013 and 2019. Data entry for these registries was mandated by the federal regulators, and the majority of variable definitions were harmonized to allow direct data comparison. A total of 244 722 transcatheter aortic valve replacements from 646 institutions in the United States and 26 673 transcatheter aortic valve replacements from 171 institutions in Japan were analyzed. Median volume per site was 65 (interquartile range, 45-97) in the United States and 28 (interquartile range, 19-41) in Japan. Overall, patients in J-TVT were older (United States: mean-age, 80.1±8.7 versus Japan: 84.4±5.2; P<0.001), were more frequently women (45.9% versus 68.1%; P<0.001), and had higher median Society of Thoracic Surgeons Predicted Risk of Mortality (5.27% versus 6.20%; P<0.001) than patients in the United States. Japan had lower unadjusted 30-day mortality (1.3% versus 3.2%; P<0.001) and composite outcomes of death, stroke, and bleeding (17.5 versus 22.5%; P<0.001) but had higher conversion to open surgery (0.94% versus 0.56%; P<0.001). Conclusions This collaborative analysis between the United States and Japan demonstrated the feasibility of international comparison using the national registries coded under mutual variable definitions. Both countries obtained excellent outcomes, although the Japanese had lower 30-day mortality and major morbidity. Harmonization-by-Doing is one of the key steps needed to build global-level learning to improve patient outcomes.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Cirurgiões , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Humanos , Japão/epidemiologia , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estados Unidos/epidemiologia
9.
Surg Endosc ; 36(7): 5136-5143, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34845554

RESUMO

BACKGROUND: With growing application of endoscopic therapy for early-stage esophageal cancer, we sought to review our experience of endoscopic mucosal resections (EMRs). The aim of our study was to understand the natural course of these patients, especially with positive margins. METHODS: A prospectively maintained database of all patients undergoing endoscopic therapies at Georgetown University Hospital for esophageal cancer was used for the analysis between 2010 and 2020. RESULTS: Of 80 patients in the EMR database, 35 were performed as index cases for esophageal adenocarcinoma. Majority (74.3%) had a pre-treatment ultrasound confirming absence of regional adenopathy. There were no post-EMR bleeding or perforation events requiring re-intervention. Complete R0 resection was achieved in 22/35 (62.9%) after initial EMR. Thirteen patients had positive margins. Of these 13 patients, only 7 patients underwent repeat endoscopic resection, 2 underwent subsequent esophagectomy, 2 received definitive radiation given poor surgical candidacy, and 2 were lost to follow-up. Overall and 5-year survival of all patients undergoing EMR was 67.9 months and 85%, respectively. Subset analysis of the 13 patients with R1 resection demonstrated an overall survival of 49.2 months and 60% 5-year survival vs overall survival of 78.9 months and 93% 5-year survival for R0 resection. At a median follow-up of 60.5 months, cancer recurrence occurred in 3 patients. All of them were successfully managed with repeat EMR. CONCLUSIONS: Endoscopic resections represent a safe and effective treatment for early-stage esophageal cancer. Patients with high-risk features should be counseled to undergo an esophagectomy if they are operable candidates.


Assuntos
Adenocarcinoma , Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Adenocarcinoma/patologia , Ressecção Endoscópica de Mucosa/efeitos adversos , Neoplasias Esofágicas/patologia , Esofagectomia/efeitos adversos , Humanos , Recidiva Local de Neoplasia/cirurgia , Estadiamento de Neoplasias , Estudos Retrospectivos , Resultado do Tratamento
10.
Ann Thorac Surg ; 113(1): 337-365, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34711394

RESUMO

Data for nearly all patients undergoing transcatheter edge-to-edge repair (TEER) and transcatheter mitral valve replacement (TMVR) with an approved device in the United States is captured in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. All data submitted for TEER or TMVR between 2014 and March 31, 2020, are reported. A total of 37,475 patients underwent a mitral transcatheter procedure, including 33,878 TEER and 3,597 TMVR. Annual procedure volumes for TEER have increased from 1,152 per year in 2014 to 10,460 per year in 2019 at 403 sites and for TMVR from 84 per year to 1,120 per year at 301 centers. Mortality rates have decreased for TEER at 30 days (5.6%-4.1%) and 1 year (27.4%-22.0%). Early off-label use data on TMVR in mitral valve-in-valve therapy led to approval by the U.S. Food and Drug Administration in 2017, and the 2019 30-day mortality rate was 3.9%. Overall improvements in outcomes over the last 6 years are apparent. (STS/ACC TVT Registry Mitral Module; NCT02245763).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Sistema de Registros , Estados Unidos
11.
Ann Thorac Surg ; 114(4): 1299-1306, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34785247

RESUMO

BACKGROUND: The relationship between institutional volume and operative mortality after surgical aortic valve replacement (SAVR) remains unclear. METHODS: From January 2013 to June 2018, 234 556 patients underwent isolated SAVR (n = 144 177) or SAVR with coronary artery bypass grafting (CABG) (n = 90 379) within the Society of Thoracic Surgeons Adult Cardiac Surgery Database. The association between annualized SAVR volume (group 1 [1-25 SAVRs], group 2 [26-50 SAVRs], group 3 [51-100 SAVRs], and group 4 [>100 SAVRs]) and operative mortality and composite major morbidity or mortality was assessed. Random effects models were used to evaluate whether historical (2013-2015) SAVR volume or risk-adjusted outcomes explained future (2016-2018) risk-adjusted outcomes. RESULTS: The annualized median number of SAVRs per site was 35 (interquartile range, 22-59; isolated aortic valve replacement [AVR], 20; AVR with CABG, 13). Among isolated SAVR cases, the mean operative mortality and composite morbidity or mortality were 1.5% and 9.7%, respectively, at the highest-volume sites (group 4), with significantly higher rates among progressively lower-volume groups (P trend < .001). After adjustment, lower-volume centers had increased odds of operative mortality (group 1 vs group 4 [reference]: adjusted odds ratio [AOR] for SAVR, 2.24 [95% CI, 1.91-2.64]; AOR for SAVR with CABG, 1.96 [95% CI, 1.67-2.30]) and major morbidity or mortality (AOR for SAVR, 1.53 [95% CI, 1.39-1.69]; AOR for SAVR with CABG, 1.46 [95% CI, 1.32-1.61]) compared with the highest-volume institutions. Substantial variation in outcomes was observed across hospitals within each volume category, and prior outcomes explained a greater proportion of hospital operative outcomes than did prior volume. CONCLUSIONS: Operative outcomes after SAVR with or without CABG is inversely associated with institutional procedure volumes; however, prior outcomes are more predictive of future outcomes than is prior volume. Given the excellent outcomes observed at many lower-volume hospitals, procedural outcomes may be preferable to procedural volumes as a quality metric.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
J Am Coll Cardiol ; 78(23): 2326-2353, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34711430

RESUMO

Data for nearly all patients undergoing transcatheter edge-to-edge repair (TEER) and transcatheter mitral valve replacement (TMVR) with an approved device in the United States is captured in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. All data submitted for TEER or TMVR between 2014 and March 31, 2020, are reported. A total of 37,475 patients underwent a mitral transcatheter procedure, including 33,878 TEER and 3,597 TMVR. Annual procedure volumes for TEER have increased from 1,152 per year in 2014 to 10,460 per year in 2019 at 403 sites and for TMVR from 84 per year to 1,120 per year at 301 centers. Mortality rates have decreased for TEER at 30 days (5.6%-4.1%) and 1 year (27.4%-22.0%). Early off-label use data on TMVR in mitral valve-in-valve therapy led to approval by the U.S. Food and Drug Administration in 2017, and the 2019 30-day mortality rate was 3.9%. Overall improvements in outcomes over the last 6 years are apparent. (STS/ACC TVT Registry Mitral Module; NCT02245763).


Assuntos
Cateterismo Cardíaco/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Sistema de Registros , Cirurgia Torácica/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Insuficiência da Valva Mitral/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
13.
Curr Cardiol Rep ; 23(9): 122, 2021 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-34269898

RESUMO

PURPOSE OF REVIEW: Given the low occurrence of clinically important paravalvular leak (PVL), there are no large registries or trials in this space to investigate management strategies. This review integrates newer evidence, particularly in imaging guidance for these complex procedures, novel techniques and approaches that our group has taken, as well as approaches to more complex PVL plugging reported in case reports. RECENT FINDINGS: Perhaps the largest area of growth in the management of PVL is the use of advanced imaging in both pre-procedure evaluation and intra-procedural guidance with gated cardiac CT, 3D TEE, and fluoroscopy fusion technologies. Outside the USA, a new device, the Occlutech PLD, has become available with early data indicating high success rates. There remains little randomized data to support the efficacy of percutaneous PVL closure. Gated cardiac CT has become key to the pre-procedure evaluation for transcatheter closure as it allows for increased procedural efficiency and more accurate pre-procedure planning, particularly when combined with 3D printing. Intra-procedural TEE-fluoro fusion allows for more rapid crossing of defects by providing a visual target for interventionalists. The advent of purpose-built devices for PVL closure may further increase the efficacy and efficiency of percutaneous closure, but significant barriers remain for approval of these devices in the USA.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Fluoroscopia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Reoperação , Resultado do Tratamento
14.
JACC Cardiovasc Interv ; 14(14): 1538-1548, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-34020928

RESUMO

OBJECTIVES: This study reports 2-year outcomes from the multicenter, prospective, single-arm CLASP study with functional mitral regurgitation (FMR) and degenerative MR (DMR) analysis. BACKGROUND: Transcatheter repair is a favorable option to treat MR. Long-term prognostic impact of the PASCAL transcatheter valve repair system in patients with clinically significant MR remains to be established. METHODS: Patients had clinically significant MR ≥3+ as evaluated by the echocardiographic core laboratory and were deemed candidates for transcatheter repair by the heart team. Assessments were performed by clinical events committee to 1 year (site-reported thereafter) and core laboratory to 2 years. RESULTS: A total of 124 patients (69% FMR, 31% DMR) were enrolled with a mean age of 75 years, 56% were male, 60% were New York Heart Association functional class III to IVa, and 100% had MR ≥3+. At 2 years, Kaplan-Meier estimates showed 80% survival (72% FMR, 94% DMR) and 84% freedom from heart failure (HF) hospitalization (78% FMR, 97% DMR), with 85% reduction in annualized HF hospitalization rate (81% FMR, 98% DMR). MR ≤1+ was achieved in 78% of patients (84% FMR, 71% DMR) and MR ≤2+ was achieved in 97% (95% FMR, 100% DMR) (all p < 0.001). Left ventricular end-diastolic volume decreased by 33 ml (p < 0.001); 93% of patients were in New York Heart Association functional class I to II (p < 0.001). CONCLUSIONS: The PASCAL repair system demonstrated sustained favorable outcomes at 2 years in FMR and DMR patients. Results showed high survival and freedom from HF rehospitalization rates with a significantly reduced annualized HF hospitalization rate. Durable MR reduction was achieved with evidence of left ventricular reverse remodeling and significant improvement in functional status. The CLASP IID/IIF randomized pivotal trial is ongoing.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Resultado do Tratamento
15.
Innovations (Phila) ; 16(1): 3-16, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33491539

RESUMO

OBJECTIVE: There is an increasing amount of evidence supporting use of transcatheter aortic valve replacement (TAVR) for treatment of aortic stenosis in patients at low or intermediate risk for surgical aortic valve replacement (SAVR). TAVR is now approved for use in all patient cohorts. Despite this, there remains debate about the relative efficacy of TAVR compared with SAVR in lower-risk cohorts and various subgroups of patients. We performed a systematic review and meta-analysis of randomized controlled trials (RCTs) and propensity-matched trials to guide a consensus among expert cardiologists and surgeons. METHODS: Studies comparing TAVR and SAVR in low- and intermediate-risk patients were identified by a thorough search of the major databases. Mortality, stroke, and other perioperative outcomes were assessed at 30 days and 1 year. RESULTS: Early mortality was lower in TAVR compared to SAVR in RCTs, but not propensity-matched studies in low-risk cohorts (0.66% vs 1.5%; odds ratio [OR] = 0.44, 95% confidence interval [CI] 0.20 to 0.98, I2 = 0%). No difference in mortality between TAVR and SAVR was identified in intermediate-risk patients at early or later time points. Incidence of perioperative stroke in 3 low-risk RCTs was significantly lower in TAVR (0.4%) than SAVR (1.4%; OR = 0.33, 95% CI 0.13 to 0.81, I2 = 0%). There was no difference in stroke for intermediate-risk patients between TAVR and SAVR. The expert panel of cardiologists and cardiac surgeons provided recommendations for TAVR and SAVR in various clinical scenarios. CONCLUSIONS: In RCTs comparing TAVR and SAVR in low-risk patients, early mortality and stroke were lower in TAVR, but did not differ at 1 year. There was no difference in mortality and stroke in intermediate-risk patients. The Multidisciplinary Heart Team must consider individual patient characteristics and preferences when recommending TAVR or SAVR. The decision must consider the long-term management of each patient's aortic valve disease.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Consenso , Humanos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
16.
Ann Thorac Surg ; 111(2): 701-722, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33213826

RESUMO

The STS-ACC TVT Registry (Society of Thoracic Surgeons-American College of Cardiology Transcatheter Valve Therapy Registry) from 2011 to 2019 has collected data on 276,316 patients undergoing transcatheter aortic valve replacement (TAVR) at sites in all U.S. states. Volumes have increased every year, exceeding surgical aortic valve replacement in 2019 (72,991 vs. 57,626), and it is now performed in all U.S. states. TAVR now extends from extreme- to low-risk patients. This is the first presentation on 8,395 low-risk patients treated in 2019. In 2019, for the entire cohort, femoral access increased to 95.3%, hospital stay was 2 days, and 90.3% were discharged home. Since 2011, the 30-day mortality rate has decreased (7.2% to 2.5%), stroke has started to decrease (2.75% to 2.3%), but pacemaker need is unchanged (10.9% to 10.8%). Alive with acceptable patient-reported outcomes is achieved in 8 of 10 patients at 1 year. The Registry is a national resource to improve care and analyze TAVR's evolution. Real-world outcomes, site performance, and the impact of coronavirus disease 2019 will be subsequently studied. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528).


Assuntos
Sistema de Registros , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Ponte Cardiopulmonar , Feminino , Nível de Saúde , Humanos , Tempo de Internação , Masculino , Marca-Passo Artificial , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estados Unidos/epidemiologia
17.
Respir Care ; 65(12): 1791-1799, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32636274

RESUMO

BACKGROUND: The transition from an ICU ventilator to a portable home ventilator (PHV) for children requiring long-term mechanical ventilation is a crucial step in preparing for discharge home and may not be successful on the first attempt. A review of this process at our institution revealed that some children required multiple trials before they were able to tolerate a PHV. A protocol was developed to standardize the transition process and reduce the number of failed attempts. Key features of the protocol included a transition readiness assessment and criteria for changing to the PHV. METHODS: A retrospective chart review was completed to evaluate the process of changing to a PHV before and after the protocol was in place during the time period of 2011-2018. Primary outcome measures included the number of transition attempts and the length of time to achieve successful transition. A successful transition attempt was defined as the ability to tolerate a PHV for 14 d. RESULTS: The study included 56 children ≤ 3 y old with a tracheostomy who required long-term ventilator support. The majority of subjects were from the neonatal ICU and had a diagnosis of bronchopulmonary dysplasia. There was a significant decrease in the number of attempts (P = .005) and in the length of time (P = .01) to successfully transition to a PHV for those who underwent the protocol. CONCLUSIONS: The process of changing from an ICU ventilator to a PHV in children requiring long-term mechanical ventilation was improved through the use of a standardized protocol. Both the number of failed attempts and the length of time to achieve successful transition were reduced when the protocol was applied. Further study is needed to evaluate other medical and nonmedical factors that may affect successful transition to a PHV.


Assuntos
Serviços de Assistência Domiciliar , Ventiladores Mecânicos , Criança , Humanos , Unidades de Terapia Intensiva , Respiração Artificial , Estudos Retrospectivos , Desmame do Respirador
18.
JACC Cardiovasc Interv ; 13(13): 1515-1525, 2020 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-32535005

RESUMO

OBJECTIVES: This study sought to report the largest series of patients receiving a surgical reoperation after transcatheter aortic valve replacement (TAVR) using the Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database. BACKGROUND: TAVR has become an effective means of treating aortic stenosis. As TAVR is used in progressively lower-risk cohorts, management of device failure will become increasingly important. METHODS: The STS Adult Cardiac Surgery Database was queried for patients with a history of prior TAVR undergoing surgical aortic valve replacement from 2011 to 2015. Observed-to-expected (O/E) mortality ratios were determined to facilitate comparison across reoperative indications and timing from index TAVR procedure. RESULTS: A total of 123 patients met inclusion criteria (median age 77 years) with an STS Predicted Risk of Mortality of 4%, 4% to 8%, and >8% in 17%, 24%, and 59%, respectively. Median time to reoperation was 2.5 (interquartile range: 0.7 to 13.0) months, and the operative mortality rate was 17.1%. Common indications for reoperation included early TAVR device failures such as paravalvular leak (15%), structural prosthetic deterioration (11%), failed repair (11%), sizing or position issues (11%), and prosthetic valve endocarditis (10%). All pre-operative risk categories were associated with an increased O/E mortality ratio (Predicted Risk of Mortality <4%: O/E 5.5; 4% to 8%: O/E 1.7; >8%: O/E 1.2). CONCLUSIONS: SAVR following early failure of TAVR, while rare, is associated with worse-than-expected outcomes as compared with similar patients initially undergoing SAVR. Continued experience with this developing technology is needed to reduce the incidence of early TAVR failure and further define optimal treatment of failed TAVR prostheses.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/cirurgia , Falha de Prótese , Reoperação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bases de Dados Factuais , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Reoperação/efeitos adversos , Reoperação/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
19.
JACC Case Rep ; 2(7): 1084-1088, 2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-34317420

RESUMO

An 87-year-old woman with a history of trastuzumab-induced left ventricular dysfunction underwent the MitraClip (Abbott Vascular, Santa Clara, California) procedure for myxomatous mitral regurgitation. She presented a month later with severe intravascular hemolytic anemia, attributed to the MitraClip. She underwent surgical mitral valve replacement and had resolution of hemolysis. (Level of Difficulty: Advanced.).

20.
Redox Biol ; 28: 101318, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31546169

RESUMO

Aurora A kinase is a master mitotic regulator whose functions are controlled by several regulatory interactions and post-translational modifications. It is frequently dysregulated in cancer, making Aurora A inhibition a very attractive antitumor target. However, recently uncovered links between Aurora A, cellular metabolism and redox regulation are not well understood. In this study, we report a novel mechanism of Aurora A regulation in the cellular response to oxidative stress through CoAlation. A combination of biochemical, biophysical, crystallographic and cell biology approaches revealed a new and, to our knowledge, unique mode of Aurora A inhibition by CoA, involving selective binding of the ADP moiety of CoA to the ATP binding pocket and covalent modification of Cys290 in the activation loop by the thiol group of the pantetheine tail. We provide evidence that covalent CoA modification (CoAlation) of Aurora A is specific, and that it can be induced by oxidative stress in human cells. Oxidising agents, such as diamide, hydrogen peroxide and menadione were found to induce Thr 288 phosphorylation and DTT-dependent dimerization of Aurora A. Moreover, microinjection of CoA into fertilized mouse embryos disrupts bipolar spindle formation and the alignment of chromosomes, consistent with Aurora A inhibition. Altogether, our data reveal CoA as a new, rather selective, inhibitor of Aurora A, which locks this kinase in an inactive state via a "dual anchor" mechanism of inhibition that might also operate in cellular response to oxidative stress. Finally and most importantly, we believe that these novel findings provide a new rationale for developing effective and irreversible inhibitors of Aurora A, and perhaps other protein kinases containing appropriately conserved Cys residues.


Assuntos
Aurora Quinase A/química , Aurora Quinase A/metabolismo , Coenzima A/administração & dosagem , Animais , Coenzima A/química , Coenzima A/farmacologia , Cristalografia por Raios X , Células HEK293 , Células Hep G2 , Humanos , Camundongos , Modelos Moleculares , Estresse Oxidativo , Fosforilação , Conformação Proteica , Fuso Acromático/efeitos dos fármacos , Fuso Acromático/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA