Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Ann Rheum Dis ; 83(7): 847-857, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38443140

RESUMO

OBJECTIVES: To assess, in spondyloarthritis (SpA), the discriminative value of the Outcome Measures in Rheumatology (OMERACT) ultrasound lesions of enthesitis and their associations with clinical features in this population. METHODS: In this multicentre study involving 20 rheumatology centres, clinical and ultrasound examinations of the lower limb large entheses were performed in 413 patients with SpA (axial SpA and psoriatic arthritis) and 282 disease controls (osteoarthritis and fibromyalgia). 'Active enthesitis' was defined as (1) power Doppler (PD) at the enthesis grade ≥1 plus entheseal thickening and/or hypoechoic areas, or (2) PD grade >1 (independent of the presence of entheseal thickening and/or hypoechoic areas). RESULTS: In the univariate analysis, all OMERACT lesions except enthesophytes/calcifications showed a significant association with SpA. PD (OR=8.77, 95% CI 4.40 to 19.20, p<0.001) and bone erosions (OR=4.75, 95% CI 2.43 to 10.10, p<0.001) retained this association in the multivariate analysis. Among the lower limb entheses, only the Achilles tendon was significantly associated with SpA (OR=1.93, 95% CI 1.30 to 2.88, p<0.001) in the multivariate analyses. Active enthesitis showed a significant association with SpA (OR=9.20, 95% CI 4.21 to 23.20, p<0.001), and unlike the individual OMERACT ultrasound lesions it was consistently associated with most clinical measures of SpA disease activity and severity in the regression analyses. CONCLUSIONS: This large multicentre study assessed the value of different ultrasound findings of enthesitis in SpA, identifying the most discriminative ultrasound lesions and entheseal sites for SpA. Ultrasound could differentiate between SpA-related enthesitis and other forms of entheseal pathology (ie, mechanical enthesitis), thus improving the assessment of entheseal involvement in SpA.


Assuntos
Entesopatia , Espondilartrite , Ultrassonografia Doppler , Humanos , Feminino , Masculino , Entesopatia/diagnóstico por imagem , Adulto , Pessoa de Meia-Idade , Ultrassonografia Doppler/métodos , Espondilartrite/diagnóstico por imagem , Espondilartrite/complicações , Artrite Psoriásica/diagnóstico por imagem , Artrite Psoriásica/complicações , Índice de Gravidade de Doença , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/patologia , Estudos de Casos e Controles
2.
Semin Arthritis Rheum ; 65: 152406, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38401294

RESUMO

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.

3.
Semin Arthritis Rheum ; 63: 152259, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37660536

RESUMO

OBJECTIVES: In the ULTIMATE study with an open label extension, we assessed the long-term effect of secukinumab at tissue level on synovitis and enthesitis, and across all psoriatic arthritis (PsA) manifestations, using both clinical evaluations and power Doppler ultrasonography (PDUS). METHODS: This randomised, placebo-controlled, Phase 3 study (ULTIMATE) included biologic-naïve patients with PsA with active PDUS synovitis and clinical enthesitis, and inadequate response to conventional synthetic disease-modifying antirheumatic drugs. The study consisted of 3 treatment periods; in the first period (baseline to week 12) patients were randomised to receive subcutaneous secukinumab (150 mg or 300 mg according to severity of skin psoriasis) or placebo every week until week 4 and once every 4 weeks up to week 12. In the second period (weeks 12-24) all patients received open-label secukinumab with placebo patients switching to secukinumab (150 mg or 300 mg). The third period (weeks 24-52) was an extended open-label treatment period. The long-term responsiveness of the Global EULAR-OMERACT Synovitis Score (GLOESS), clinical enthesitis and global PDUS-detected enthesitis score (using two candidate definitions of activity) at patient level, together with clinical efficacy across key manifestations of PsA and safety were assessed. RESULTS: Of the 166 patients enrolled, 144 completed week 52. A significant reduction in GLOESS was demonstrated in the secukinumab group vs placebo at week 12, followed by a stable reduction of synovitis until week 52 in the secukinumab group while placebo switchers from week 12 reached a similar level of reduction at week 24 with stability thereafter. Likewise, a significant reduction in the Spondyloarthritis Research Consortium of Canada (SPARCC) enthesitis index was shown in the secukinumab group vs placebo at week 12 with sustained improvement to week 52. Global OMERACT PDUS enthesitis scores were numerically lower in secukinumab vs placebo switchers in the first two treatment periods, with some stability in the third period in both groups. Improvements in clinical responses were also observed across all key domains of PsA up to week 52 in both treatment groups with no new or unexpected safety signals. CONCLUSIONS: ULTIMATE showed consistent improvements in clinically and ultrasound-assessed synovitis and enthesitis and sustained clinical efficacy through week 52 in patients with PsA treated with secukinumab and placebo switched to secukinumab.


Assuntos
Antirreumáticos , Artrite Psoriásica , Entesopatia , Sinovite , Humanos , Artrite Psoriásica/complicações , Artrite Psoriásica/diagnóstico por imagem , Artrite Psoriásica/tratamento farmacológico , Anticorpos Monoclonais Humanizados/efeitos adversos , Antirreumáticos/efeitos adversos , Sinovite/diagnóstico por imagem , Sinovite/tratamento farmacológico , Sinovite/induzido quimicamente , Entesopatia/diagnóstico por imagem , Entesopatia/tratamento farmacológico , Resultado do Tratamento , Método Duplo-Cego
4.
Lancet Rheumatol ; 5(8): e474-e482, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38251579

RESUMO

BACKGROUND: The Calcium Pyrophosphate Deposition (CPPD) subgroup of the Outcome Measures in Rheumatology (OMERACT) Ultrasound working group was established to validate ultrasound as an outcome measure instrument for CPPD, and in 2017 has developed and validated standardised definitions for elementary lesions for the detection of calcium pyrophosphate crystals in joints. The aim of this study was to develop and evaluate the reliability of a consensus-based ultrasound scoring system for CPPD extent, representing the next phase in the OMERACT methodology. METHODS: In this study the novel scoring system for CPPD was developed through a stepwise process, following an established OMERACT ultrasound methodology. Following a previous systematic review to gather available evidence on existing scoring systems for CPPD, the novel scoring system was developed through a Delphi survey based on the expert opinion of the members of the OMERACT Ultrasound working group-CPPD subgroup. The reliability of the scoring system was then tested on a web-based and patient-based exercise. Intra-reader and inter-reader reliability of the new scoring system was assessed using weighted Light's κ coefficients. FINDINGS: The four-grade semiquantitative scoring system consisted of: grade 0 (no findings consistent with CPPD), grade 1 (≤3 single spots or 1 small deposit), grade 2 (>3 single spots or >1 small deposit or ≥1 larger deposit occupying ≤50% of the structure under examination in the reference image-ie, the scanning view with the highest grade of depositions), and grade 3 (deposits that occupy more than 50% of the structure under examination in the reference image). The score should be applied to the knee (menisci and hyaline cartilage) and the triangular fibrocartilage complex of the wrist. The intra-reader and inter-reader reliabilities on static images were almost perfect (κ 0·90 [95% CI 0·79-1·00] and κ 0·84 [0·79-0·88]), and on the eight patients recruited (four [50%] female and four [50%] male) were substantial (κ 0·72 [95% CI 0·47 to 0·96] and 0·66 [0·61 to 0·71]). INTERPRETATION: This OMERACT ultrasound scoring system for CPPD was reliable on both static images and patients. The scoring system might be a valuable tool for ensuring valid and comparable results in clinical trials and could help monitor the extent of crystal deposition in patients with CPPD in clinical practice. FUNDING: The Italian Ministry of Health - Ricerca Corrente.


Assuntos
Calcinose , Pirofosfato de Cálcio , Humanos , Feminino , Masculino , Reprodutibilidade dos Testes , Difosfatos , Ultrassonografia
5.
Rheumatology (Oxford) ; 61(12): 4863-4874, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-35293988

RESUMO

OBJECTIVES: To investigate the reliability of the OMERACT US Task Force definition of US enthesitis in SpA. METHODS: In this web exercise, based on the evaluation of 101 images and 39 clips of the main entheses of the lower limbs, the elementary components included in the OMERACT definition of US enthesitis in SpA (hypoechoic areas, entheseal thickening, power Doppler signal at the enthesis, enthesophytes/calcifications, bone erosions) were assessed by 47 rheumatologists from 37 rheumatology centres in 15 countries. Inter- and intra-observer reliability of the US components of enthesitis was calculated using Light's kappa, Cohen's kappa, Prevalence And Bias Adjusted Kappa (PABAK) and their 95% CIs. RESULTS: Bone erosions and power Doppler signal at the enthesis showed the highest overall inter-reliability [Light's kappa: 0.77 (0.76-0.78), 0.72 (0.71-0.73), respectively; PABAK: 0.86 (0.86-0.87), 0.73 (0.73-0.74), respectively], followed by enthesophytes/calcifications [Light's kappa: 0.65 (0.64-0.65), PABAK: 0.67 (0.67-0.68)]. This was moderate for entheseal thickening [Light's kappa: 0.41 (0.41-0.42), PABAK: 0.41 (0.40-0.42)], and fair for hypoechoic areas [Light's kappa: 0.37 (0.36-0.38); PABAK: 0.37 (0.37-0.38)]. A similar trend was observed in the intra-reliability exercise, although this was characterized by an overall higher degree of reliability for all US elementary components compared with the inter-observer evaluation. CONCLUSIONS: The results of this multicentre, international, web-based study show a good reliability of the OMERACT US definition of bone erosions, power Doppler signal at the enthesis and enthesophytes/calcifications. The low reliability of entheseal thickening and hypoechoic areas raises questions about the opportunity to revise the definition of these two major components for the US diagnosis of enthesitis.


Assuntos
Entesopatia , Humanos , Reprodutibilidade dos Testes , Entesopatia/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia Doppler/métodos , Internet
6.
Rev. argent. reumatol ; 28(1): 17-27, 2017. grafs
Artigo em Espanhol | LILACS | ID: biblio-911965

RESUMO

Objetivo: El objetivo de nuestro estudio fue evaluar la prevalencia de entesopatía subclínica en pacientes con psoriasis cutánea (Ps) utilizando un score ultrasonográfico (US) como herramienta diagnóstica en la práctica diaria y evaluar la habilidad de dicho score para discriminar pacientes con Ps y Artritis Psoriásica (APs). Material y Métodos: Se estudiaron pacientes con diagnóstico de Ps (según diagnóstico por dermatólogo), APs (según criterios CASPAR) y controles sanos (CS). Se evaluaron diez sitios de entesis (de manera bilateral): inserción del tendón del cuádriceps, tendón proximal y distal del ligamento patelar, tendón de Aquiles y fascia plantar. La US identificó los siguientes hallazgos: engrosamiento tendinoso, erosión ósea, entesofito, bursitis y señal Power Doppler (PD). Se calculó el score US para entesitis GUESS. El desempeño del score para discriminar entre APs y Ps se evaluó utilizando curvas ROC. Resultados: Se incluyeron 51 sujetos: APs=16, Ps=15 y CS=20. La edad media fue de 42±13 años y el 39% eran mujeres. La mitad de los pacientes con APs presentaron entesopatía clínica en comparación con ninguno de los otros grupos. Se evaluaron un total de 510 sitios de entesis (APs=160, Ps=150, HC=200). Los pacientes con Ps mostraron significativamente una mayor frecuencia de entesofitos, erosiones y PD que los CS. La puntuación media del score GUESS fue diferente entre los grupos (media±DE): APs=13±4, Ps=8±4, CS=3±2 (p<0,01). El área bajo la curva (ABC) para el diagnóstico de APs fue de 0,79 (IC95%=0,63 a 0,95). Conclusiones: Los pacientes con Ps mostraron una alta frecuencia de entesopatía subclínica en la evaluación US. El score GUESS mostró una alta sensibilidad y moderada especificidad para discriminar entre los pacientes con APs y Ps


Assuntos
Psoríase , Artrite Psoriásica , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA