Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 64(2): 025006, 2019 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-30618412

RESUMO

The purpose of this study was to investigate breathing-motion induced interplay effects for stereotactic body radiotherapy (SBRT) of liver tumours treated with flattening-filter free (FFF) volumetric modulated arc therapy (VMAT). Ten patients previously treated with liver SBRT were included in this study. All patients had four-dimensional computed tomography (4DCT) scans acquired prior to treatment. The 4DCT was sorted into 8-10 phases covering an equal time interval. A FFF VMAT plan was created for one fraction in the mid-ventilation phase for each patient. To generate dose distributions including both interplay effects and dose blurring, a sub-plan was calculated for each phase. The total dose distributions were accumulated to the mid-ventilation phase using the deformed vector fields (DVF) from deformable image registration between the corresponding CT and the mid-ventilation phase CT. A blurred dose distribution, not including interplay effects, was also obtained by distributing the delivery of the whole plan uniformly on all phases, and was similarly accumulated to the mid-ventilation phase. To isolate interplay effects, this blurred dose distribution was subtracted from the total dose distribution with interplay effects. The near minimum dose (D 98%), mean dose (D mean), heterogeneity index (HI), and the near minimum dose difference (ΔD 98%) between the accumulated dose distributions with and without interplay effects were calculated within the gross tumour volume (GTV) for each patient. Comparing the accumulated dose distributions with and without interplay effects, the D 98% decreased for nine of the ten patients and the HI increased for all patients. The median and minimum differences in D 98% were -2.1% and -5.0% (p = 0.006), respectively, and the median HI significantly increased from 6.2% to 12.2% (p = 0.002). The median ΔD 98% was -4.0% (range -7% to -1.5%). In conclusion, statistically significant breathing-induced interplay effects were observed for a single fraction of FFF VMAT liver SBRT, resulting in heterogeneous dose distributions within the GTV.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Hepáticas/cirurgia , Movimento , Órgãos em Risco/efeitos da radiação , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Respiração , Simulação por Computador , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
2.
Phys Med Biol ; 53(20): N387-96, 2008 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-18827319

RESUMO

Following the implementation of advanced treatment procedures in radiotherapy, there is a need for dynamic dose verification in 3D. Gel dosimetry could potentially be used for such measurements. However, recently published data show that certain types of gels have a dose rate and fractionation dependence. The aim of this study was to investigate the feasibility of using a polymer gel dosimeter for dose verification of dynamic radiotherapy. To investigate the influence of dose rate dependence during respiratory-like motion in and out of the beam, a respiration robot together with two types of gel systems (normoxic methacrylic acid gel (nMAG) and normoxic polyacrylamide gel (nPAG)) were used. Reference measurements were obtained using a linear diode array (LDA). Expected results, if there was no influence of the dose rate variation, were calculated by convolving the static irradiated gel data with the motion function controlling the robot. To investigate the fractionation dependence, the gels were irradiated using gated and ungated deliveries. Magnetic resonance imaging was used to evaluate the absorbed dose response of the gel. The measured gel data coincided well with the LDA data. Also, the calculated data agreed well with the measured dynamic gel data, i.e. no dose rate dependence due to motion was observed. The difference in the R2 response for the gels receiving ungated and gated, i.e. fractionated, deliveries was less than 1% for the nPAG and 4% for the nMAG, for absorbed doses up to 2 Gy. The maximum difference was 1.2% for the nPAG and 9% for the nMAG, which occurred at the highest given dose (4 Gy). The investigated gels were found to be feasible detectors for dose measurements under respiratory-like motion. For dose verification of dynamic RT involving gated delivery, e.g. breathing-adapted radiotherapy, relative absorbed dose evaluation should be used in order to minimize the effects of fractionated irradiation.


Assuntos
Géis/química , Géis/efeitos da radiação , Radiometria/métodos , Radioterapia Conformacional/métodos , Mecânica Respiratória , Relação Dose-Resposta à Radiação , Estudos de Viabilidade , Humanos , Teste de Materiais , Movimento (Física) , Doses de Radiação , Radiometria/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA