Ultraschall Med ; 41(6): 658-667, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31137051

RESUMO

PURPOSE: The objective of this study was to prove the efficacy of Doppler ultrasonography (US-Doppler) in the follow-up of patients with GD treated with radioactive iodine. METHODS: 97 patients (77 female and 20 male) with a mean age of 42 years (SD ±â€Š15) and with prior diagnosis of GD were treated with radioiodine. In total, 88.5 % achieved euthyroidism or hypothyroidism after treatment. The study was documented before treatment and one, three, and six months after treatment with radioactive iodine (131I) by a single investigator. The volume, echogenicity, echotexture and vascularization of the glands as well as the peak systolic velocity (PSV) of the inferior thyroid arteries were evaluated and compared with the laboratory data. RESULTS: Thyroid volume and PSV had a statistically significant correlation with hormone levels (p < 0.05). The mean pre-dose therapeutic thyroid volume was 43.01 ±â€Š3.88 cm3 and was 11.58 ±â€Š11.26 cm3 6 months after treatment. The mean PSV before 131I was 90.06 ±â€Š44.13 cm/s and decreased significantly over time (p < 0.001). Six months after the therapeutic dose, the mean PSV was 32.95 ±â€Š16.36 cm/s. However, the subjective parameters did not have a significant correlation with the normalization of the thyroid hormones. CONCLUSION: Doppler US was useful for monitoring the therapeutic response of GD patients after treatment with radioiodine by evaluating the thyroid volume and peak systolic velocity.


Assuntos
Doença de Graves , Neoplasias da Glândula Tireoide , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Seguimentos , Doença de Graves/diagnóstico por imagem , Doença de Graves/radioterapia , Humanos , Radioisótopos do Iodo , Masculino , Ultrassonografia Doppler em Cores
2.
Ultrasound Med Biol ; 45(1): 50-55, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30366607

RESUMO

We prospectively evaluated the effectiveness of contrast-enhanced ultrasonography (CEUS) for differentiation of benign versus malignant portal vein thrombosis (PVT). We studied a total of 43 patients with chronic liver disease, hepatocellular carcinoma-suggestive nodules and confirmed PVT, in whom the nature of the PVT was confirmed by follow-up imaging (US, computed tomography and/or magnetic resonance imaging) performed up to 6 mo after CEUS. PVT was assessed by US, Doppler US and CEUS with respect to vessel wall disruption and/or invasion, color Doppler vascularization, pulsed Doppler vascularization pattern and CEUS enhancement and vascularization pattern, and thrombi were classified as benign or malignant based on these findings. Follow-up studies revealed malignant PVT in 22 of the 43 patients (51%) and benign PVT in 21 patients (49%). CEUS findings were consistent with follow-up studies in 41 of the 43 patients (95%), with κ = 0.903 (p < 0.0001), sensitivity = 91% and specificity = 100%, indicating that CEUS can be confidently used to differentiate benign from malignant portal vein thrombosis in the setting of chronic liver disease.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Veia Porta/diagnóstico por imagem , Veia Porta/patologia , Ultrassonografia/métodos , Trombose Venosa/diagnóstico por imagem , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Trombose Venosa/patologia
3.
Ultrasound Int Open ; 4(1): E2-E15, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29423461

RESUMO

"How to perform contrast-enhanced ultrasound (CEUS)" provides general advice on the use of ultrasound contrast agents (UCAs) for clinical decision-making and reviews technical parameters for optimal CEUS performance. CEUS techniques vary between centers, therefore, experts from EFSUMB, WFUMB and from the CEUS LI-RADS working group created a discussion forum to standardize the CEUS examination technique according to published evidence and best personal experience. The goal is to standardise the use and administration of UCAs to facilitate correct diagnoses and ultimately to improve the management and outcomes of patients.

4.
J Clin Ultrasound ; 44(9): 587-594, 2016 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-27492569

RESUMO

PURPOSE: To select the best predictors of cervical lymph node malignancy based on gray-scale and power Doppler sonography using multivariate analysis. METHODS: We evaluated sonographically a total of 97 lymph nodes in the neck that were subjected to fine-needle aspiration biopsy. The gray-scale and power Doppler sonography parameters that we analyzed using multivariate logistic regression included size, shape, echogenicity, echotexture, margins, hilum, presence of microcalcifications or necrosis, vascularization, and resistance index (RI). RESULTS: The three variables with a diagnostic accuracy exceeding 80% were an altered vascularization, heterogeneous echotexture, and abnormal hilum. Malignant nodes exhibited higher RI and larger sizes than benign nodes, and the best cutoff values to distinguish malignant from benign lymph nodes were an RI of 0.77 and a short axis ≥ 0.9 cm. Altered vascularization, a short axis ≥ 0.9 cm, and abnormal hilum were the best predictors of malignancy. CONCLUSIONS: The best sonographic predictors of lymph node malignancy are, in descending order, an altered vascularization, a short axis ≥ 0.9 cm, an abnormal hilum, and a heterogeneous echotexture. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:587-594, 2016.


Assuntos
Carcinoma de Células Escamosas/patologia , Carcinoma/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Linfadenopatia/diagnóstico por imagem , Linfadenopatia/patologia , Neoplasias da Glândula Tireoide/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Carcinoma Papilar , Diagnóstico Diferencial , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Pescoço , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Câncer Papilífero da Tireoide , Ultrassonografia Doppler em Cores , Adulto Jovem
6.
Ultrasound Med Biol ; 39(2): 187-210, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23137926

RESUMO

Initially, a set of guidelines for the use of ultrasound contrast agents was published in 2004 dealing only with liver applications. A second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some non-liver applications. Time has moved on, and the need for international guidelines on the use of CEUS in the liver has become apparent. The present document describes the third iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS) using contrast specific imaging techniques. This joint WFUMB-EFSUMB initiative has implicated experts from major leading ultrasound societies worldwide. These liver CEUS guidelines are simultaneously published in the official journals of both organizing federations (i.e., Ultrasound in Medicine and Biology for WFUMB and Ultraschall in der Medizin/European Journal of Ultrasound for EFSUMB). These guidelines and recommendations provide general advice on the use of all currently clinically available ultrasound contrast agents (UCA). They are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.


Assuntos
Algoritmos , Meios de Contraste/normas , Aumento da Imagem/normas , Neoplasias Hepáticas/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Ultrassonografia/normas , Humanos , Internacionalidade
7.
J Clin Exp Hepatol ; 3(2): 96-101, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25755482

RESUMO

BACKGROUND/OBJECTIVE: The early detection of focal hepatic lesions using ultrasound scanning is challenging, and this challenge becomes even greater in the presence of diffuse parenchymal disease. This study aimed to evaluate the diagnostic performance of elastography and contrast-enhanced ultrasonography (CEUS) in the early detection of hepatocellular lesions in an experimental rat model of nonalcoholic steatohepatitis (NASH). METHODS: B-mode and Doppler ultrasonography was performed weekly in 30 rats divided into a NASH group (n = 20) and a group without liver disease (n = 10). The animals underwent elastography and CEUS and were then euthanized. Liver nodules were assessed by histopathology. RESULTS: Doppler mapping results of lesions with vascularization were considered indicative of malignancy, with a sensitivity of 29% before and 71% after contrast injection. The specificity was 71% before and 96% after CEUS. Elastograms of positive lesions showed areas of high stiffness, which were indicative of malignancy. This malignancy was confirmed by the histologic evaluation, with a sensitivity of 90% and a specificity of 60%. After CEUS analysis, 4 nodules were identified that were not observed on B-mode ultrasonography. Early wash-in was significantly associated with malignancy (sensitivity of 88% and specificity of 67%). CONCLUSIONS: Both techniques allow for the correct diagnosis of well-differentiated to moderately differentiated hepatocellular carcinomas with good accuracy in an experimental rat model of NASH.

8.
Arq. bras. endocrinol. metab ; 56(3): 173-177, Apr. 2012. tab
Artigo em Inglês | LILACS | ID: lil-626268

RESUMO

OBJECTIVES: To precisely classify the various forms of TD, and then to screen for mutations in transcription factor genes active in thyroid development. SUBJECTS AND METHODS: Patients underwent ultrasound, thyroid scan, and serum thyroglobulin measurement to accurately diagnose the form of TD. DNA was extracted from peripheral leukocytes. The PAX8, and NKX2.5 genes were evaluated in all patients, and TSH receptor (TSHR) gene in those with hypoplasia. RESULTS: In 27 nonconsanguineous patients with TD, 13 were diagnosed with ectopia, 11 with hypoplasia, and 3 with athyreosis. No mutations were detected in any of the genes studied. CONCLUSION: Sporadic cases of TD are likely to be caused by epigenetic factors, rather than mutations in thyroid transcription factors or genes involved in thyroid development.


OBJETIVOS: Classificar corretamente as várias formas de DT e depois rastrear por mutações em genes que participam no desenvolvimento da tireoide. SUJEITOS E MÉTODOS: Os pacientes realizaram ultrassonografia, cintilografia e tireoglobulina sérica para o diagnóstico preciso de DT. DNA foi extraído de leucócitos periféricos. Os genes PAX8 e NKX2.5 foram estudados em todos os pacientes e o gene do receptor do TSH (TSHR) foi estudado na hipoplasia. RESULTADOS: Avaliaram-se 27 pacientes sem consanguinidade com DT, dos quais 13 foram diagnosticados com ectopia, 11 com hipoplasia e 3 com atireose. Nenhuma mutação foi detectada nos genes estudados. CONCLUSÃO: Casos esporádicos de DT são provavelmente causados mais por fatores epigenéticos do que por mutações em fatores de transcrição ou genes envolvidos no desenvolvimento tireoidiano.


Assuntos
Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Adulto Jovem , Hipotireoidismo Congênito/genética , Proteínas de Homeodomínio/genética , Mutação , Fatores de Transcrição Box Pareados/genética , Disgenesia da Tireoide/genética , Tireotropina/genética , Fatores de Transcrição/genética , Disgenesia da Tireoide/diagnóstico
9.
J Feline Med Surg ; 13(6): 399-404, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21277819

RESUMO

Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m/s(2). The mean renal-interlobar artery ratio was 1.45±0.57. The RI values obtained in this study were similar to values reported in the literature. Some conditions that lead to a decrease in compliance and to an increase in vascular resistance can affect the Doppler spectral waveforms without changes in RI. To our knowledge, there are no studies that were directed toward to the normal ESA values of the renal vasculature in Persian cats. This study introduced a new ratio between the PSV of the RA and the IA. This index was developed based on the well-known effects of Doppler on the detection of stenosis, regardless of the cause. Further studies are necessary to verify the hemodynamic behavior of this index under pathological conditions in cats as well as the effect of aging, nephropathies and systemic pressure on Doppler velocimetric parameters.


Assuntos
Aorta Abdominal/fisiologia , Rim/irrigação sanguínea , Artéria Renal/fisiologia , Circulação Renal/fisiologia , Ultrassonografia Doppler em Cores/veterinária , Animais , Aorta Abdominal/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Gatos , Feminino , Rim/diagnóstico por imagem , Masculino , Valores de Referência , Artéria Renal/diagnóstico por imagem , Resistência Vascular
10.
Endocr J ; 57(7): 587-93, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20467163

RESUMO

Methods currently employed to establish the etiology of congenital hypothyroidism include thyroid ultrasound and scintigraphic exams. Thyroglobulin is a protein almost exclusively secreted by thyroid tissue and indirectly reflects the amount of follicular cells. Even though thyroglobulin is easy to measure, it has been not frequently used because of discordant results to distinguish mainly athyreosis and ectopy (dysgenesis). Knowing the differences in inheritance and prognosis of thyroid dysgenesis and dyshormonogenesis, it is important to define the etiology of CH, combining tools that are easy, fast and available in most medical centers. Our objective was to evaluate and compare color Doppler ultrasound and serum thyroglobulin with radionuclide scan to define the etiology of congenital hypothyroidism. We evaluated 38 children above 3 years-old off-treatment that performed serum thyroglobulin by immunofluorometric assay, color Doppler ultrasound and radionuclide study. On color Doppler ultrasound, 11 patients had athyreosis, 5 ectopic glands, being 1 associated to hemiagenesis. Twenty one had topic thyroid (3 goiters, 10 normal, 8 hypoplastic). Hemiagenesis and cystic lesion were not revealed by radionuclide scan. We observed substantial agreement between color Doppler ultrasound and radionuclide scan (kappa=0.745, p<0.0001). Serum thyroglobulin in athyreosis ranged from <1.0 to 18.7 micro g/L. Patients with ectopic glands showed wider thyroglobulin range (4.5 to 123 micro g/L, median 28.4 micro g/L). Only one patient showed thyroglobulin deficiency. By using color Doppler ultrasound and serum thyroglobulin levels as valuable combined tools, we established the etiology of congenital hypothyroidism limiting excessive and harmful exams in children, like radionuclide scan.


Assuntos
Hipotireoidismo Congênito/diagnóstico , Hipotireoidismo Congênito/etiologia , Técnicas de Diagnóstico Endócrino , Tireoglobulina/sangue , Glândula Tireoide/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Hipotireoidismo Congênito/sangue , Feminino , Humanos , Masculino , Cintilografia , Tireoglobulina/análise , Testes de Função Tireóidea , Ultrassonografia Doppler em Cores
SELEÇÃO DE REFERÊNCIAS