Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 84(2): 1000-1010, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31880346

RESUMO

PURPOSE: Inhomogeneous excitation at ultrahigh field strengths (7T and above) compromises the reliability of quantified dynamic contrast-enhanced breast MRI. This can hamper the introduction of ultrahigh field MRI into the clinic. Compensation for this non-uniformity effect can consist of both hardware improvements and post-acquisition corrections. This paper investigated the correctable radiofrequency transmit ( B1+ ) range post-acquisition in both simulations and patient data for 7T MRI. METHODS: Simulations were conducted to determine the minimum B1+ level at which corrections were still beneficial because of noise amplification. Two correction strategies leading to differences in noise amplification were tested. The effect of the corrections on a 7T patient data set (N = 38) with a wide range of B1+ levels was investigated in terms of time-intensity curve types as well as washin, washout and peak enhancement values. RESULTS: In simulations assuming a common amount of T1 saturation, the lowest B1+ level at which the SNR of the corrected images was at least that of the original precontrast image was 43% of the nominal angle. After correction, time-intensity curve types changed in 24% of included patients, and the distribution of curve types corresponded better to the distribution found in literature. Additionally, the overlap between the distributions of washin, washout, and peak enhancement values for grade 1 and grade 2 tumors was slightly reduced. CONCLUSION: Although the correctable range varies with the amount of T1 saturation, post-acquisition correction for inhomogeneous excitation was feasible down to B1+ levels of 43% of the nominal angle in vivo.


Assuntos
Mama , Imageamento por Ressonância Magnética , Mama/diagnóstico por imagem , Humanos , Aumento da Imagem , Ondas de Rádio , Reprodutibilidade dos Testes
2.
J Magn Reson Imaging ; 51(6): 1858-1867, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31854487

RESUMO

BACKGROUND: Previous studies have shown discrepancies between index and synchronous breast cancer in histology and molecular phenotype. It is yet unknown whether this observation also applies to the MRI phenotype. PURPOSE: To investigate whether the appearance of breast cancer on MRI (i.e. phenotype) is different from that of additional breast cancer (i.e. synchronous cancer), and whether such a difference, if it exists, is associated with prognosis. STUDY TYPE: Retrospective. POPULATION: In all, 464 consecutive patients with early-stage ER+/HER2- breast cancer were included; 34/464 (7.3%) had 44 synchronous cancers in total (34 ipsilateral, 10 contralateral). SEQUENCE: 1.5T, contrast-enhanced T1 -weighted. ASSESSMENT: We assessed imaging phenotype using 50 quantitative features from each cancer and applied principal component analysis (PCA) to identify independent properties. The degree of phenotype difference was assessed. An association between phenotype differences and prognosis in terms of the Nottingham Prognostic Index (NPI) and PREDICT score were analyzed. STATISTICAL TESTS: PCA; Wilcoxon rank sum test; Benjamini-Hochberg to control the false discovery rate. RESULTS: PCA identified eight components in patients with ipsilateral synchronous cancer. Six out of eight were significantly different between index and synchronous cancer. These components represented features describing texture (three components, P < 0.001, P < 0.001, P = 0.004), size (P < 0.001), smoothness (P < 0.001), and kinetics (P = 0.004). Phenotype differences in terms of the six components were split in tertiles. Larger phenotype differences in size, kinetics, and texture were associated with significantly worse prognosis in terms of NPI (P = 0.019, P = 0.045, P = 0.014), but not for the PREDICT score (P = 0.109, P = 0.479, P = 0.109). PCA identified six components in patients with contralateral synchronous cancer. None were significantly different from the index cancer (P = 0.178, P = 0.178, P = 0.178, P = 0.326, P = 0.739, P = 0.423). DATA CONCLUSION: The MRI phenotype of ER+/HER2- breast cancer was different from that of ipsilateral synchronous cancer and a large phenotype difference was associated with worse prognosis. No significant difference was found for synchronous contralateral cancer. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2020;51:1858-1867.


Assuntos
Neoplasias da Mama , Mama , Neoplasias da Mama/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Fenótipo , Prognóstico , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA