Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
2.
Hong Kong Med J ; 25(1): 48-57, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30643038

RESUMO

BACKGROUND: Conventional treatment of deep vein thrombosis (DVT) of the lower extremities by anticoagulation alone has been proven to be insufficient to prevent recurrence and post-thrombotic syndrome (PTS). Early restoration of venous patency and preservation of valvular function by endovascular surgery has been advocated. The aim of this study was to review the efficacy and safety of percutaneous mechanical thrombectomy (PMT) against catheter-directed thrombolysis (CDT) in the treatment of acute iliofemoral DVT. METHODS: Three hundred sixty-nine articles were identified through screening of the PubMed, EMBASE, and Cochrane databases from January 2006 to December 2016. RESULTS: Fifteen retrospective studies and one prospective registry, totalling 1170 patients, were recruited for qualitative synthesis. The venous patency rate ranged from 75% to 100% with mean follow-up of 12.3 months. The rates of PTS and recurrent DVT were less than 17% and 15%, respectively. The overall mortality rate was 0.26%. Compared with CDT, PMT was shown to reduce PTS at 1 year (Villalta score: 2.1 ± 3.0 in the PMT group and 5.1 ± 4.1 in the CDT group, P=0.03) and bleeding complications (packed cells transfused: 0.2 ± 0.3 units in the pharmacomechanical thrombectomy group and 1.2 ± 0.7 units in the CDT group, P<0.05). CONCLUSION: Percutaneous mechanical thrombectomy is a safe and effective treatment for acute iliofemoral DVT in terms of restoration of venous patency, prevention of DVT recurrence, and PTS. Compared with CDT alone, PMT offers a lower risk of PTS and bleeding complications.


Assuntos
Extremidade Inferior/irrigação sanguínea , Trombólise Mecânica/efeitos adversos , Síndrome Pós-Trombótica/prevenção & controle , Terapia Trombolítica/efeitos adversos , Trombose Venosa/terapia , Doença Aguda , Fibrinolíticos/administração & dosagem , Fibrinolíticos/efeitos adversos , Humanos , Síndrome Pós-Trombótica/epidemiologia , Síndrome Pós-Trombótica/etiologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Trombose Venosa/fisiopatologia
3.
Asian Cardiovasc Thorac Ann ; 27(2): 80-86, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30563352

RESUMO

AIM: We present the clinical outcomes of patients who underwent delayed (>30 days) open surgical repair after endovascular aortic aneurysm repair. METHODS: All patients receiving delayed open repair of infrarenal and juxtarenal aortic aneurysms after endovascular repair from July 2001 to December 2017 were retrospectively reviewed. Patients' baseline characteristics, indications for delayed open conversion, and time between endovascular repair and open conversion are described. Early outcomes included operative approach, morbidity, and mortality. Midterm outcomes included survival. RESULTS: Twenty-two (3.3%) of 667 patients with prior infrarenal endovascular aortic aneurysm repair had delayed open conversion (20 elective and 2 emergency). The time from endovascular repair to open conversion was 60 ± 36 months. The indications were 6 (27%) type Ia endoleaks, 6 (27%) type II endoleaks with enlarging sac size, 2 (9%) endotensions, 7 (32%) unknown types of endoleak, and 1 (5%) graft infection. The 7 minutes unknown endoleaks were confirmed as lumbar leaks in 4 cases and fabric leaks in 3. Operative time was 222 ± 48 min with blood loss of 2211 ± 2057 mL. Hospital stay after conversion was 12 ± 8 days. There was no 30-day mortality. Estimated survival rates were 96%, 91%, 86%, 79% and 57% at 1, 2, 3, 4, and 5 years postoperatively. CONCLUSION: Delayed conversion to open surgery after endovascular aortic aneurysm repair by endograft explantation appears to be safe with good short- and mid-term outcomes. With careful preoperative assessment, open conversion remained a realistic and viable option in patients with failed endovascular treatment.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Conversão para Cirurgia Aberta , Endoleak/cirurgia , Procedimentos Endovasculares , Infecções Relacionadas à Prótese/cirurgia , Tempo para o Tratamento , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Conversão para Cirurgia Aberta/efeitos adversos , Conversão para Cirurgia Aberta/mortalidade , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Reoperação , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Fatores de Tempo , Falha de Tratamento
4.
Asian J Surg ; 41(5): 490-497, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29233598

RESUMO

BACKGROUND: The study aims to report outcomes of open repair (OR) and endovascular aneurysm repair (EVAR) in octogenarians. METHODS: Consecutive patients aged between 80 and 89 who underwent OR or EVAR were identified from a prospectively collected departmental database. Short-term outcomes included 30 days mortalities and perioperative complications; long-term outcomes included overall survival and re-intervention using the Kaplan-Meier method. Logistic regression was used to identify predictors for operative mortality and Cox regression analysis was used to identify predictors for long-term survival. RESULTS: From January 1999 to December 2013, 53 underwent open repairs (23 emergency and 30 elective) and 115 underwent endovascular repairs (11 emergency and 104 elective). For elective procedures, 30 days operative mortalities were 6.7% and 0% in OR and EVAR respectively (Chi square test, p = 0.049). For emergency procedures, 30 days mortalities were 39.1% and 27.2% respectively (Chi square test, p = 0.705). Overall 5 years survival rates were 40.4% and 36.7% after OR and EVAR respectively. Rupture of aneurysm (Odd ratio 18.8, 95% CI 3.4-104.5, p = 0.001) was the only predictor for 30 days mortality. Rupture of aneurysm (Hazard ratio 2.0, 95% CI 1.3-3.3, p = 0.003), history of lung disease (Hazard ratio 1.7, 95% CI 1.0-2.9, p = 0.039) and history of renal disease (Hazard ratio 2.1, 95% CI 1.4-3.1, p < 0.001) were independent predictors for long-term overall survival. CONCLUSION: Decision of AAA repair in octogenarians should not be based on age alone. Both elective OR and EVAR had acceptable perioperative risk, but emergency repair, lung disease and renal impairment predicted poor long-term survival.


Assuntos
Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Fatores Etários , Idoso de 80 Anos ou mais , Ruptura Aórtica , Procedimentos Cirúrgicos Eletivos , Emergências , Feminino , Previsões , Humanos , Estimativa de Kaplan-Meier , Nefropatias , Modelos Logísticos , Masculino , Modelos de Riscos Proporcionais , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
5.
Vascular ; 25(2): 184-189, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27357283

RESUMO

Background The study aims to conduct a review of the surgical management of carotid body tumor. Methods Consecutive patients with CBT who received surgical interventions from January 1994 to January 2014 at our institution were reviewed. Clinical, operative, pathological and follow up information were reported. Results Twenty patients (four males; median age was 36) with 21 CBT operations were recorded during the period. One patient undertook sequential operations for bilateral CBTs. Patients had 19 neck mass, 1 incidental finding and 1 facial nerve palsy. Six CBTs (28.6%) were Shamblin class I, ten (47.6%) were class II and five (23.8%) were class III. Nine CBTs had preoperative conjunctive embolization. Two operations required internal carotid artery resection and reconstruction. Four patients received subtotal resections, while 17 achieved complete resection. Complications included two major strokes, three hoarse voice and two Horner's syndrome. Shamblin class was significant predictor of operative time, blood loss, and whether complete resection accomplished, but could not predict postoperative complication. With median follow up period of 94 months, there was no tumor recurrence found in those had complete resection. Conclusions This small cohort showed that Shamblin class was significant in predicting technical difficulties but could not predict occurrence of complications.


Assuntos
Artérias Carótidas/cirurgia , Tumor do Corpo Carotídeo/cirurgia , Corpo Carotídeo/cirurgia , Procedimentos Cirúrgicos Vasculares , Adulto , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Corpo Carotídeo/diagnóstico por imagem , Corpo Carotídeo/patologia , Tumor do Corpo Carotídeo/classificação , Tumor do Corpo Carotídeo/diagnóstico por imagem , Tumor do Corpo Carotídeo/patologia , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Embolização Terapêutica , Feminino , Hong Kong , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica , Estudos Retrospectivos , Fatores de Risco , Veia Safena/transplante , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/métodos , Adulto Jovem
6.
Asian J Surg ; 40(5): 329-337, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26857853

RESUMO

BACKGROUND/OBJECTIVE: This study aims to examine the relationship between weather changes and acute aortic events in a subtropical territory. METHODS: A linear regression analysis was performed in a pan-territory epidemiological survey for a period of 10 years on the impacts of meteorological factors (ambient temperature, atmospheric pressure, relative humidity, amount of cloud, rainfall, number of lightning strikes, presence of typhoon, and thunderstorm warning) on the daily incidences of acute aortic dissections and ruptured aortic aneurysms. Meteorological variables were retrieved on a daily basis from a well-established observatory, and the daily incidences of aortic dissections and rupture of aortic aneurysms were retrieved from the Clinical Data Analysis and Reporting System. RESULTS: During the study period (January 2005 to December 2014), 3878 patients were identified as having acute aortic dissections, and 1174 patients had ruptured aortic aneurysms. Corresponding averaged daily incidences were 1.06 and 0.32, respectively. The incidences of aortic dissection and ruptured aortic aneurysm in a day could be predicted by ambient temperature in degrees Celsius using the following linear regression models: (1) incidence of aortic dissection = 1.548 - 0.021 × temperature; (2) incidence of ruptured aortic aneurysm = 0.564 - 0.010 × temperature. In addition, both high atmospheric pressure and absence of thunderstorm warning are positively associated with more aortic dissections. For rupture of aortic aneurysms, high atmospheric pressure and low relative humidity were positive predictors. In multiple regression analysis, however, ambient temperature was the only significant predictor for both acute aortic dissections and ruptured aortic aneurysms. CONCLUSION: This is the first pan-territory study to show an attributable effect of ambient temperature on acute aortic events. This paper confirms that even in a subtropical country, meteorological variables were important factors influencing acute aortic events.


Assuntos
Dissecção Aórtica/etiologia , Ruptura Aórtica/etiologia , Tempo (Meteorologia) , Dissecção Aórtica/epidemiologia , Ruptura Aórtica/epidemiologia , Inquéritos Epidemiológicos , Hong Kong/epidemiologia , Humanos , Incidência , Modelos Lineares , Estudos Longitudinais , Estudos Retrospectivos , Fatores de Risco , Estações do Ano
7.
Eur J Vasc Endovasc Surg ; 53(1): 133-139, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27908677

RESUMO

OBJECTIVE: This study aimed to investigate variation of blood flow to renal arteries in custom-made and pivot branch (p-branch) fenestrated endografting, using a computational fluid dynamics (CFD) technique. METHODS: Idealised models of custom-made and p-branch fenestrated grafting were constructed on a basis of a 26 mm stent graft. The custom-made fenestration was designed with a 6 mm diameter, while the 5 mm depth renal p-branch was created with a 6 mm inner and 15 mm outer fenestration. Two configurations (option A and option B) were constructed with different locations of p-branches. Option A had both renal p-branches at the same level, whereas option B contained two staggered p-branches at lower positions. The longitudinal stent orientation in both custom-made and p-branch models was represented by a takeoff angle (ToA) between the renal stent and distal stent graft centreline, varying from 55° to 125°. Computational simulations were performed with realistic boundary conditions governing the blood flow. RESULTS: In both custom-made and p-branch fenestrated models, the flow rate and wall shear stress (WSS) were generally higher and recirculation zones were smaller when the renal stent faced caudally. In custom-made models, the highest flow rate (0.390 L/min) was detected at 70° ToA and maximum WSS on vessel segment (16.8 Pa) was attained at 55° ToA. In p-branch models, option A and option B displayed no haemodynamic differences when having the same ToA. The highest flow rate (0.378 L/min) and maximum WSS on vessel segment (16.7 Pa) were both calculated at 55° ToA. The largest and smallest recirculation zones occurred at 90° and 55° ToA respectively in both custom-made and p-branch models. Custom-made fenestrated models exhibited consistently higher flow rate and shear stress and smaller recirculation zones in renal arteries than p-branch models at the same ToA. CONCLUSIONS: Navigating the renal stents towards caudal orientation can achieve better haemodynamic outcomes in both fenestrated devices. Custom-made fenestrated stent grafts are the preferred choice for elective patients. Further clinical evidence is required to validate the computational simulations.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Hemodinâmica , Desenho de Prótese , Artéria Renal/fisiologia , Artéria Renal/cirurgia , Stents , Aneurisma da Aorta Abdominal/fisiopatologia , Feminino , Humanos , Masculino , Resultado do Tratamento
8.
Hong Kong Med J ; 22(6): 538-45, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27779098

RESUMO

INTRODUCTION: The use of a proximal Palmaz stent is a well-recognised technique to treat proximal endoleak in endovascular aortic repair. This study aimed to report the effectiveness and safety of an intra-operative Palmaz stent for immediate type 1a endoleak in Hong Kong patients. METHODS: This case series was conducted at a tertiary hospital in Hong Kong. In a cohort of 494 patients who underwent infrarenal endovascular aortic repair from July 1999 to September 2015, 12 (2.4%) received an intra-operative proximal Palmaz stent for type 1a endoleak. Immediate and subsequent proximal endoleak on follow-up image was documented. RESULTS: Morphological review of the pre-repair aneurysm neck showed five conical, one funnel, five cylindrical and one undetermined short neck, with a median neck angle of 61 degrees (range, 19-109 degrees). Stent grafts used included seven Cook Zenith, one Cook Aorto-Uni-Iliac device, three Metronic Endurant, and one TriVascular Ovation. Eleven Palmaz stents were placed successfully as intended, but one of them was accidentally placed too low. Of the 12 type 1a endoleaks, postoperative imaging revealed immediate resolution of eight whilst four had improved. After a median follow-up of 16 (range, 1-59) months, none of the subsequent imaging showed a type 1a endoleak. The mean size of the aneurysm sac reduced from 7.4 cm preoperatively to 7.3 cm at 1 month, 6.9 cm at 6 months, 7.1 cm at 1 year, and 6.1 cm at 2 years postoperatively. None of these patients required aortic reintervention or had device-related early- or mid-term mortality. One patient required delayed iliac re-interventions for an occluded limb at 10 days post-surgery. CONCLUSION: In our cohort, Palmaz stenting was effective and safe in securing proximal sealing and fixation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Complicações Pós-Operatórias/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Feminino , Hong Kong , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
Eur J Vasc Endovasc Surg ; 51(5): 656-63, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26922108

RESUMO

OBJECTIVES: Despite technically successful thoracic endovascular stent graft repair (TEVAR) in patients with Stanford Type B aortic dissection (TBAD), long-term follow up studies have shown that the false lumen may continue to dilate. The aim of this study was to analyze the possible mechanisms leading to such changes from a hemodynamic perspective. METHODS: Twenty-eight ex vivo fresh porcine TBAD models (Mo A: 10; Model B: 12; Model C: 6) were established to simulate three clinical situations: Model A with patent false lumen (pre-TEVAR); Model B with distal re-entry only (post-TEVAR), and Model C with thrombus filling in the false lumen and a distal re-entry (chronic stage of post-TEVAR). Synchronous pressure waveforms were taken from both the true and the false lumen. True lumen and false lumen pressure differences were calculated for each model as four indices: systolic index (SI), diastolic index (DI), mean pressure index (MPI) and area under curve index (AUCI). These indices were compared between the three models. RESULTS: False lumen pressure and corresponding pressure-accumulating effects were significantly higher in Model A than in Model C: SI (99.9% vs. 189.4%; p < .001); MPI and AUCI (99.5% vs. 128.2%; 99.5% vs. 128%; p < .001). The SI, MPI, and AUCI were significantly higher in Model B compared with Model C. The differences between the four indices were not significant between Model A and B. The false lumen area under curve (AUC) in Model C was merely lowered by 20% compared with its true lumen (67.5 mmHg vs. 85.2 mmHg). CONCLUSION: The false lumen pressure remained unchanged in the non-thrombosed segment with patent blood flow after the primary entry tear sealed. Intraluminal pressure reduction in the thrombosed false lumen was significant. However, nearly 80% of the pressure remained in the thrombosed false lumen. If this high intra-thrombus pressure persists, it may contribute to delayed aneurysmal formation after endovascular treatment.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares/métodos , Stents , Implante de Prótese Vascular , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Humanos , Enxerto Vascular/métodos
10.
Eur J Vasc Endovasc Surg ; 51(3): 441-51, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26684597

RESUMO

BACKGROUND: Simulation training in endovascular surgery provides opportunities for trainees to practice and learn from non-patient based experience. Several types of endovascular simulators are available commercially. Previous studies on endovascular simulation training can be categorized into trials in which only a simulator was used when measuring performance metrics or "trials within simulation"; patient specific procedure rehearsals; and randomized, controlled trials (RCTs) or translational studies. OBJECTIVES: To examine whether endovascular simulation training can improve surgeon techniques and patient outcomes in real clinical settings. METHODS: A literature review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. All searches were done via PubMed and Embase. Review articles, and papers that were not related to endovascular surgery and not within the scope of interest were excluded. References of review articles were further screened according to the exclusion criteria. RESULTS: In total, 909 records were identified and 290 duplicates were removed. Thirty-one were included in the qualitative analysis. Twenty-three were trials within simulation and most of them found statistically significant improvements in procedure time, fluoroscopy time, and contrast volume. Five were patient specific procedure rehearsals and showed that simulation significantly affected the fluoroscopy angle and improved performance metrics. Three were RCTs and revealed mainly positive results on a Global Rating Scale and procedure specific rating scale. CONCLUSIONS: Contemporary evidence shows that performance metrics within endovascular simulations improve with simulation training. Successful translation to in vivo situations is observed in patient specific procedure rehearsals and RCTs on real procedures. However, there is no level I evidence to show that predictive validity of simulation can definitively improve patient outcomes. Current literature supports the idea that there is a beneficial role of simulation in endovascular training. Future studies are needed to confirm the efficacy of simulation in endovascular surgical training and to see if simulation is superior to traditional training in the operating theatre.


Assuntos
Simulação por Computador , Educação Médica Continuada/métodos , Procedimentos Endovasculares/educação , Competência Clínica , Humanos
11.
Allergy ; 70(10): 1269-77, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26109279

RESUMO

BACKGROUND: Research on the origins and development of human IgE-expressing (IgE(+) ) cells is required for understanding the pathogenesis of allergy and asthma. These studies have been thwarted by the rarity of IgE(+) cells in vivo and the low frequency of class switch recombination (CSR) to IgE ex vivo. To determine the main source of IgE(+) cells, we investigated the relation between the phenotypic composition of tonsil B cells and the CSR to IgE ex vivo. METHODS: Human tonsil B cells were analyzed by flow cytometry (FACS) and cultured with IL-4 and anti-CD40 to induce CSR to IgE. Naïve, germinal center (GC), early GC (eGC), and memory tonsil B cells were isolated by FACS, and their capacities for IL-4 and anti-CD40 signaling, cell proliferation, and de novo class switching to IgE were analyzed by RT-PCR and FACS. RESULTS: B cells from different tonsils exhibited varying capacities for CSR to IgE ex vivo. This was correlated with the percentage of eGC B cells in the tonsil at the outset of the culture. Despite relatively poor cell viability, eGC and GC B-cell cultures produced the highest yields of IgE(+) cells compared to naïve and memory B-cell cultures. The main factors accounting for this result were the strength of IL-4R and CD40 signaling and relative rates of cell proliferation. CONCLUSIONS: This study shows that the maturation state of tonsil B cells determines their capacity to undergo class switching to IgE ex vivo, with the GC-derived B cells yielding the highest percentage of IgE(+) cells.


Assuntos
Subpopulações de Linfócitos B/imunologia , Subpopulações de Linfócitos B/metabolismo , Centro Germinativo/citologia , Switching de Imunoglobulina/genética , Switching de Imunoglobulina/imunologia , Imunoglobulina E/genética , Imunoglobulina E/imunologia , Antígenos CD40/antagonistas & inibidores , Antígenos CD40/metabolismo , Sobrevivência Celular/imunologia , Células Cultivadas , Humanos , Memória Imunológica , Interleucina-4/metabolismo , Ativação Linfocitária/genética , Ativação Linfocitária/imunologia , Contagem de Linfócitos , Tonsila Palatina/citologia , Transdução de Sinais
12.
Eur J Surg Oncol ; 40(9): 1143-50, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24969958

RESUMO

OBJECTIVES: Methylthioadenosine phosphorylase (MTAP), a ubiquitously expressed protein, plays important roles in purine biosynthesis. Locating near to each other on chromosome 9p21-22, codeletion of the MTAP and p16(Ink4A) genes have been reported in non-small cell lung cancer (NSCLC). The aim of this study is to determine the respective prognostic value of MTAP and p16 by considering their correlation in NSCLC patients. MATERIALS AND METHODS: We analyzed MTAP and p16 protein expression by immunohistochemical staining on 99 NSCLC tissue microarray samples. The association between MTAP and p16 expression levels and prognosis were analyzed using the Kaplan-Meier method and Cox proportional hazards model for prognosis. RESULTS: Patients with a low MTAP expression level had poor overall survival (P = 0.010) and disease-free survival (P = 0.002). Low p16 expression indicated a trend toward poor overall survival (P = 0.138) and disease-free survival (P = 0.199). There was a significant positive correlation between MTAP and p16 expression levels (Spearman's ρ = 0.402, P < 0.001). By multivariate analyses, the MTAP expression level retained its independent prognostic power and p16 expression loss of the correlation with prognosis. Concordant loss of MTAP and p16 expression was observed in 24 out of 99 patients (24.2%). Patients with concordant loss of MTAP and p16 expression had the worst prognosis compared to patients with high expression of both markers. CONCLUSION: MTAP expression is an independent prognostic factor and has greater prognostic significance than p16 expression in NSCLC. Concordant loss of MTAP and p16 expression indicates poor outcomes in lung cancer patients.


Assuntos
Adenocarcinoma/metabolismo , Carcinoma de Células Grandes/metabolismo , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma de Células Escamosas/metabolismo , Neoplasias Pulmonares/metabolismo , Proteínas de Neoplasias/metabolismo , Purina-Núcleosídeo Fosforilase/metabolismo , Adenocarcinoma/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Grandes/mortalidade , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Carcinoma de Células Escamosas/mortalidade , Inibidor p16 de Quinase Dependente de Ciclina , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/mortalidade , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Modelos de Riscos Proporcionais
13.
Vasc Endovascular Surg ; 48(3): 201-6, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24407506

RESUMO

INTRODUCTION: Carotid endarterectomy (CEA) is a well-established surgical technique in stroke prophylaxis. Long-term follow-up data on restenosis or recurrent neurological symptoms in Oriental patients are unclear. METHODS: Patients' notes from 1994 to 2011 were retrospectively reviewed and analyzed. A total of 301 cases of CEA were identified. RESULTS: A lower restenosis rate was associated with the use of patch and never smokers in both univariate and multivariate analysis. Use of patch and never smokers were also found to be significantly associated with longer restenosis-free survival. Use of patch and postoperative use of statin were associated with better overall survival in both univariate and multivariate analysis. CONCLUSION: Use of patch and lack of smoking history are associated with less restenosis and longer restenosis-free survival. Use of patch and use of postoperative statin improves overall survival. Although restenosis after CEA is relatively common, reintervention was rarely necessary.


Assuntos
Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Centros de Atenção Terciária , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/diagnóstico , Intervalo Livre de Doença , Feminino , Hong Kong , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Modelos de Riscos Proporcionais , Recidiva , Encaminhamento e Consulta , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fumar/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
14.
Eur J Vasc Endovasc Surg ; 46(5): 549-56, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24054777

RESUMO

OBJECTIVE: There are no published data on the expression of low-density lipoprotein receptor-related protein 1 (LRP1) in human aortic tissues with abdominal aortic aneurysm (AAA), although some researchers have suggested that LRP1 may be a crucial regulator in the pathogenesis of AAA. The aim of this pilot study is to investigate LRP1 expression in aortic tissues from Chinese patients with AAA compared with normal control tissues. MATERIALS AND METHODS: This study used human abdominal aortic tissues with or without AAA as a research model. Aneurysmal abdominal aortas were collected from Chinese patients with AAA (n = 12) during open surgical aneurysmal repair at our institution, and normal control non-aneurysmal abdominal aortas were collected from Chinese healthy organ donors (n = 12) during organ transplantation. Protein expression of LRP1 was analyzed by western blotting and immunohistochemistry. RESULTS: LRP1 protein expression was significantly lower in AAA (mean LRP1AAA/LRP1(Normal Control) = 0.51 ± 0.28) than in normal control aortic tissues (mean LRP1(Normal Control)/LRP1(Normal Control) = 1 ± 0.18) in our small sample cohort (p < .001). No significant correlation was shown between LRP1 protein expression and the size of AAA (p > .05). CONCLUSIONS: Our pilot result suggests that a reduction in LRP1 protein expression may be associated with aneurysm progression.


Assuntos
Aorta Abdominal/química , Aneurisma da Aorta Abdominal/metabolismo , Proteína-1 Relacionada a Receptor de Lipoproteína de Baixa Densidade/análise , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/patologia , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/cirurgia , Biomarcadores/análise , Estudos de Casos e Controles , China , Progressão da Doença , Regulação para Baixo , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Fatores de Risco
15.
Vascular ; 21(5): 317-22, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23493275

RESUMO

Giant pseudoaneurysms of the splenic artery, with a diameter of 5 cm or more, are rare surgical emergencies, and conventional open surgery usually involves splenectomy. The aim of this study is to report two cases from our institution and to review the world's literature on successful endovascular treatment of patients with giant splenic artery pseudoaneurysms. A retrospective review of a prospectively entered departmental computerized database was performed for the two patients from our institution. Articles were searched electronically from PubMed and Medline, using the terms 'giant splenic artery', 'endovascular' and 'embolization'; and relevant cases were reviewed from the world's literature. We hereby report two patients with giant splenic artery pseudoaneurysms who were treated successfully with endovascular procedures. In addition to the two patients from our institution, there were five patients with giant splenic artery pseudoaneurysms in the published literature who underwent successful endovascular management. The first patient of our series had the largest pseudoaneursym size of 7.2 × 8.1 cm, which is the largest documented pseudoaneursym in the current literature. We report two cases of giant splenic artery pseudoaneurysm with one being the largest pseudoaneurysm treated with endovascular technique in the current literature. Endovascular coil embolization of main trunk of splenic artery is less invasive than open surgical treatment for giant splenic artery pseudoaneurysm, and circumvents the problem of difficult exposure, especially in those patients with significant co-morbidity.


Assuntos
Falso Aneurisma/terapia , Embolização Terapêutica , Procedimentos Endovasculares/métodos , Artéria Esplênica , Idoso , Falso Aneurisma/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Esplênica/diagnóstico por imagem , Resultado do Tratamento
18.
Eur J Vasc Endovasc Surg ; 44(4): 399-405, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22835767

RESUMO

OBJECTIVES: The aim of this study is to present novel ex-vivo models in the study of complex haemodynamical changes in Stanford type B aortic dissection (TBAD). MATERIALS AND METHODS: Fifteen fresh porcine aortas were harvested and preserved with 4 °C saline. Ex-vivo models were developed to simulate TBAD in three different situations: model A with patent false lumen, model B with distal re-entry only and model C with proximal primary entry only. These models were connected to standardised pulsatile pumps and the pressure waveforms were monitored and compared. The aortas were scanned with ultrasonography and subjected to post-experiment autopsy. RESULTS: The three different models were successfully created (n = 13). Pulsatile flow testing was successful and the shapes of the pressure waveforms were similar to those taken from human aorta. Post-testing gross examination confirmed the success of modelling. CONCLUSION: Porcine aortas may prove to be useful ex-vivo models in the study of aortic dissection haemodynamics. These models are reproducible and may be used in the study of complex haemodynamic forces during the development and propagation of TBAD. Our three porcine models give a potential possibility in helping clinicians isolate and analyse complex haemodynamical factors in the development, propagation and prognosis of TBAD.


Assuntos
Aneurisma da Aorta Torácica/fisiopatologia , Dissecção Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Ultrassonografia Doppler/métodos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/patologia , Animais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/patologia , Modelos Animais de Doenças , Suínos
19.
PLoS One ; 7(5): e37389, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22655044

RESUMO

This present study aims to investigate the changes in the inflammatory markers after elective endovascular treatment of Type B aortic dissection with aneurysm, as related to different anatomical features of the dissection flap in the paravisceral perfusion. Consecutive patients with type B aortic dissections with elective endovascular stent graft repair were recruited and categorized into different groups. Serial plasma levels of cytokines (Interleukin-1ß, -6, -8, -10, TNF-α), chemokines (MCP-1), and serum creatinine were monitored at pre-, peri- and post-operative stages. The length of stent graft employed in each surgery was retrieved and correlated with the change of all studied biochemical parameters. A control group of aortic dissected patients with conventional medication management was recruited for comparing the baseline biochemical parameters. In total, 22 endovascular treated and 16 aortic dissected patients with surveillance were recruited. The endovascular treated patients had comparable baseline levels as the non-surgical patients. There was no immediate or thirty day-mortality, and none of the surgical patients developed post-operative mesenteric ischaemia or clinically significant renal impairment. All surgical patients had detectable pro-inflammatory mediators, but none of the them showed any statistical significant surge in the peri-operative period except IL-1ß and IL-6. Similar results were obtained when categorized into different groups. IL-1ß and IL-6 showed maximal levels within hours of the endovascular procedure (range, 3.93 to 27.3 higher than baseline; p = 0.001), but returned to baseline 1 day post-operatively. The change of IL-1ß and IL-6 at the stent graft deployment was statistically greater in longer stent graft (p>0.05). No significant changes were observed in the serum creatinine levels. In conclusion, elective endovascular repair of type B aortic dissection associated with insignificant changes in inflammatory mediators and creatinine. All levels fell toward basal levels post-operatively suggesting that thoracic endovascular aortic repair is rather less aggressive with insignificant inflammatory modulation.


Assuntos
Aorta/cirurgia , Aneurisma Aórtico/sangue , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/sangue , Dissecção Aórtica/cirurgia , Citocinas/sangue , Idoso , Dissecção Aórtica/imunologia , Aneurisma Aórtico/imunologia , Creatina/sangue , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA