Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
J Natl Compr Canc Netw ; 22(3): 158-166, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38626807

RESUMO

BACKGROUND: Pancreatic adenocarcinoma (PC) is a highly lethal malignancy with a survival rate of only 12%. Surveillance is recommended for high-risk individuals (HRIs), but it is not widely adopted. To address this unmet clinical need and drive early diagnosis research, we established the Pancreatic Cancer Early Detection (PRECEDE) Consortium. METHODS: PRECEDE is a multi-institutional international collaboration that has undertaken an observational prospective cohort study. Individuals (aged 18-90 years) are enrolled into 1 of 7 cohorts based on family history and pathogenic germline variant (PGV) status. From April 1, 2020, to November 21, 2022, a total of 3,402 participants were enrolled in 1 of 7 study cohorts, with 1,759 (51.7%) meeting criteria for the highest-risk cohort (Cohort 1). Cohort 1 HRIs underwent germline testing and pancreas imaging by MRI/MR-cholangiopancreatography or endoscopic ultrasound. RESULTS: A total of 1,400 participants in Cohort 1 (79.6%) had completed baseline imaging and were subclassified into 3 groups based on familial PC (FPC; n=670), a PGV and FPC (PGV+/FPC+; n=115), and a PGV with a pedigree that does not meet FPC criteria (PGV+/FPC-; n=615). One HRI was diagnosed with stage IIB PC on study entry, and 35.1% of HRIs harbored pancreatic cysts. Increasing age (odds ratio, 1.05; P<.001) and FPC group assignment (odds ratio, 1.57; P<.001; relative to PGV+/FPC-) were independent predictors of harboring a pancreatic cyst. CONCLUSIONS: PRECEDE provides infrastructure support to increase access to clinical surveillance for HRIs worldwide, while aiming to drive early PC detection advancements through longitudinal standardized clinical data, imaging, and biospecimen captures. Increased cyst prevalence in HRIs with FPC suggests that FPC may infer distinct biological processes. To enable the development of PC surveillance approaches better tailored to risk category, we recommend adoption of subclassification of HRIs into FPC, PGV+/FPC+, and PGV+/FPC- risk groups by surveillance protocols.


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/epidemiologia , Detecção Precoce de Câncer/métodos , Estudos Prospectivos , Predisposição Genética para Doença , Imageamento por Ressonância Magnética
2.
Sci Data ; 11(1): 404, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643291

RESUMO

Magnetic resonance imaging (MRI) has experienced remarkable advancements in the integration of artificial intelligence (AI) for image acquisition and reconstruction. The availability of raw k-space data is crucial for training AI models in such tasks, but public MRI datasets are mostly restricted to DICOM images only. To address this limitation, the fastMRI initiative released brain and knee k-space datasets, which have since seen vigorous use. In May 2023, fastMRI was expanded to include biparametric (T2- and diffusion-weighted) prostate MRI data from a clinical population. Biparametric MRI plays a vital role in the diagnosis and management of prostate cancer. Advances in imaging methods, such as reconstructing under-sampled data from accelerated acquisitions, can improve cost-effectiveness and accessibility of prostate MRI. Raw k-space data, reconstructed images and slice, volume and exam level annotations for likelihood of prostate cancer are provided in this dataset for 47468 slices corresponding to 1560 volumes from 312 patients. This dataset facilitates AI and algorithm development for prostate image reconstruction, with the ultimate goal of enhancing prostate cancer diagnosis.


Assuntos
Imageamento por Ressonância Magnética , Próstata , Neoplasias da Próstata , Humanos , Masculino , Inteligência Artificial , Aprendizado de Máquina , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
3.
Invest Radiol ; 58(10): 720-729, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37222526

RESUMO

INTRODUCTION: Prostate cancer diffusion weighted imaging (DWI) MRI is typically performed at high-field strength (3.0 T) in order to overcome low signal-to-noise ratio (SNR). In this study, we demonstrate the feasibility of prostate DWI at low field enabled by random matrix theory (RMT)-based denoising, relying on the MP-PCA algorithm applied during image reconstruction from multiple coils. METHODS: Twenty-one volunteers and 2 prostate cancer patients were imaged with a 6-channel pelvic surface array coil and an 18-channel spine array on a prototype 0.55 T system created by ramping down a commercial magnetic resonance imaging system (1.5 T MAGNETOM Aera Siemens Healthcare) with 45 mT/m gradients and 200 T/m/s slew rate. Diffusion-weighted images were acquired with 4 non-collinear directions, for which b = 50 s/mm 2 was used with 8 averages and b = 1000 s/mm 2 with 40 averages; 2 extra b = 50 s/mm 2 were used as part of the dynamic field correction. Standard and RMT-based reconstructions were applied on DWI over different ranges of averages. Accuracy/precision was evaluated using the apparent diffusion coefficient (ADC), and image quality was evaluated over 5 separate reconstructions by 3 radiologists with a 5-point Likert scale. For the 2 patients, we compare image quality and lesion visibility of the RMT reconstruction versus the standard one on 0.55 T and on clinical 3.0 T. RESULTS: The RMT-based reconstruction in this study reduces the noise floor by a factor of 5.8, thereby alleviating the bias on prostate ADC. Moreover, the precision of the ADC in prostate tissue after RMT increases over a range of 30%-130%, with the increase in both signal-to-noise ratio and precision being more prominent for a low number of averages. Raters found that the images were consistently of moderate to good overall quality (3-4 on the Likert scale). Moreover, they determined that b = 1000 s/mm 2 images from a 1:55-minute scan with the RMT-based reconstruction were on par with the corresponding images from a 14:20-minute scan with standard reconstruction. Prostate cancer was visible on ADC and calculated b = 1500 images even with the abbreviated 1:55-minute scan reconstructed with RMT. CONCLUSIONS: Prostate imaging using DWI is feasible at low field and can be performed more rapidly with noninferior image quality compared with standard reconstruction.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Estudos de Viabilidade , Neoplasias da Próstata/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Razão Sinal-Ruído , Reprodutibilidade dos Testes
4.
Gastrointest Endosc Clin N Am ; 33(3): 533-546, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37245934

RESUMO

Pancreatic cystic lesions are frequently identified on cross-sectional imaging. As many of these are presumed branch-duct intraductal papillary mucinous neoplasms, these lesions generate much anxiety for the patients and clinicians, often necessitating long-term follow-up imaging and even unnecessary surgical resections. However, the incidence of pancreatic cancer is overall low for patients with incidental pancreatic cystic lesions. Radiomics and deep learning are advanced tools of imaging analysis that have attracted much attention in addressing this unmet need, however, current publications on this topic show limited success and large-scale research is needed.


Assuntos
Adenocarcinoma Mucinoso , Carcinoma Ductal Pancreático , Cisto Pancreático , Neoplasias Pancreáticas , Humanos , Carcinoma Ductal Pancreático/patologia , Carcinoma Ductal Pancreático/cirurgia , Adenocarcinoma Mucinoso/patologia , Adenocarcinoma Mucinoso/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Pâncreas/patologia , Cisto Pancreático/diagnóstico por imagem
5.
ArXiv ; 2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37131871

RESUMO

The fastMRI brain and knee dataset has enabled significant advances in exploring reconstruction methods for improving speed and image quality for Magnetic Resonance Imaging (MRI) via novel, clinically relevant reconstruction approaches. In this study, we describe the April 2023 expansion of the fastMRI dataset to include biparametric prostate MRI data acquired on a clinical population. The dataset consists of raw k-space and reconstructed images for T2-weighted and diffusion-weighted sequences along with slice-level labels that indicate the presence and grade of prostate cancer. As has been the case with fastMRI, increasing accessibility to raw prostate MRI data will further facilitate research in MR image reconstruction and evaluation with the larger goal of improving the utility of MRI for prostate cancer detection and evaluation. The dataset is available at https://fastmri.med.nyu.edu.

6.
Abdom Radiol (NY) ; 48(4): 1401-1408, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36749368

RESUMO

BACKGROUND: Three-dimensional (3D) printed anatomic models can facilitate presurgical planning by providing surgeons with detailed knowledge of the exact location of pertinent anatomical structures. Although 3D printed anatomic models have been shown to be useful for pre-operative planning, few studies have demonstrated how these models can influence quantitative surgical metrics. OBJECTIVE: To prospectively assess whether patient-specific 3D printed prostate cancer models can improve quantitative surgical metrics in patients undergoing robotic-assisted radical prostatectomy (RARP). METHODS: Patients with MRI-visible prostate cancer (PI-RADS V2 ≥ 3) scheduled to undergo RARP were prospectively enrolled in our IRB approved study (n = 82). Quantitative surgical metrics included the rate of positive surgical margins (PSMs), operative times, and blood loss. A qualitative Likert scale survey to assess understanding of anatomy and confidence regarding surgical approach was also implemented. RESULTS: The rate of PSMs was lower for the 3D printed model group (8.11%) compared to that with imaging only (28.6%), p = 0.128. The 3D printed model group had a 9-min reduction in operating time (213 ± 42 min vs. 222 ± 47 min) and a 5 mL reduction in average blood loss (227 ± 148 mL vs. 232 ± 114 mL). Surgeon anatomical understanding and confidence improved after reviewing the 3D printed models (3.60 ± 0.74 to 4.20 ± 0.56, p = 0.62 and 3.86 ± 0.53 to 4.20 ± 0.56, p = 0.22). CONCLUSIONS: 3D printed prostate cancer models can positively impact quantitative patient outcomes such as PSMs, operative times, and blood loss in patients undergoing RARP.


Assuntos
Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Estudos de Coortes , Imageamento por Ressonância Magnética , Prostatectomia/métodos , Margens de Excisão , Impressão Tridimensional , Resultado do Tratamento
7.
J Magn Reson Imaging ; 58(4): 1055-1064, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36651358

RESUMO

BACKGROUND: Demand for prostate MRI is increasing, but scan times remain long even in abbreviated biparametric MRIs (bpMRI). Deep learning can be leveraged to accelerate T2-weighted imaging (T2WI). PURPOSE: To compare conventional bpMRIs (CL-bpMRI) with bpMRIs including a deep learning-accelerated T2WI (DL-bpMRI) in diagnosing prostate cancer. STUDY TYPE: Retrospective. POPULATION: Eighty consecutive men, mean age 66 years (47-84) with suspected prostate cancer or prostate cancer on active surveillance who had a prostate MRI from December 28, 2020 to April 28, 2021 were included. Follow-up included prostate biopsy or stability of prostate-specific antigen (PSA) for 1 year. FIELD STRENGTH AND SEQUENCES: A 3 T MRI. Conventional axial and coronal T2 turbo spin echo (CL-T2), 3-fold deep learning-accelerated axial and coronal T2-weighted sequence (DL-T2), diffusion weighted imaging (DWI) with b = 50 sec/mm2 , 1000 sec/mm2 , calculated b = 1500 sec/mm2 . ASSESSMENT: CL-bpMRI and DL-bpMRI including the same conventional diffusion-weighted imaging (DWI) were presented to three radiologists (blinded to acquisition method) and to a deep learning computer-assisted detection algorithm (DL-CAD). The readers evaluated image quality using a 4-point Likert scale (1 = nondiagnostic, 4 = excellent) and graded lesions using Prostate Imaging Reporting and Data System (PI-RADS) v2.1. DL-CAD identified and assigned lesions of PI-RADS 3 or greater. STATISTICAL TESTS: Quality metrics were compared using Wilcoxon signed rank test, and area under the receiver operating characteristic curve (AUC) were compared using Delong's test. SIGNIFICANCE: P = 0.05. RESULTS: Eighty men were included (age: 66 ± 9 years; 17/80 clinically significant prostate cancer). Overall image quality results by the three readers (CL-T2, DL-T2) are reader 1: 3.72 ± 0.53, 3.89 ± 0.39 (P = 0.99); reader 2: 3.33 ± 0.82, 3.31 ± 0.74 (P = 0.49); reader 3: 3.67 ± 0.63, 3.51 ± 0.62. In the patient-based analysis, the reader results of AUC are (CL-bpMRI, DL-bpMRI): reader 1: 0.77, 0.78 (P = 0.98), reader 2: 0.65, 0.66 (P = 0.99), reader 3: 0.57, 0.60 (P = 0.52). Diagnostic statistics from DL-CAD (CL-bpMRI, DL-bpMRI) are sensitivity (0.71, 0.71, P = 1.00), specificity (0.59, 0.44, P = 0.05), positive predictive value (0.23, 0.24, P = 0.25), negative predictive value (0.88, 0.88, P = 0.48). CONCLUSION: Deep learning-accelerated T2-weighted imaging may potentially be used to decrease acquisition time for bpMRI. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Idoso , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
8.
Abdom Radiol (NY) ; 48(1): 282-290, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36171342

RESUMO

PURPOSE: Fat-suppressed T2-weighted imaging (T2-FS) requires a long scan time and can be wrought with motion artifacts, urging the development of a shorter and more motion robust sequence. We compare the image quality of a single-shot T2-weighted MRI prototype with deep-learning-based image reconstruction (DL HASTE-FS) with a standard T2-FS sequence for 3 T liver MRI. METHODS: 41 consecutive patients with 3 T abdominal MRI examinations including standard T2-FS and DL HASTE-FS, between 5/6/2020 and 11/23/2020, comprised the study cohort. Three radiologists independently reviewed images using a 5-point Likert scale for artifact and image quality measures, while also assessing for liver lesions. RESULTS: DL HASTE-FS acquisition time was 54.93 ± 16.69, significantly (p < .001) shorter than standard T2-FS (114.00 ± 32.98 s). DL HASTE-FS received significantly higher scores for sharpness of liver margin (4.3 vs 3.3; p < .001), hepatic vessel margin (4.2 vs 3.3; p < .001), pancreatic duct margin (4.0 vs 1.9; p < .001); in-plane (4.0 vs 3.2; p < .001) and through-plane (3.9 vs 3.4; p < .001) motion artifacts; other ghosting artifacts (4.3 vs 2.9; p < .001); and overall image quality (4.0 vs 2.9; p < .001), in addition to receiving a higher score for homogeneity of fat suppression (3.7 vs 3.4; p = .04) and liver-fat contrast (p = .03). For liver lesions, DL HASTE-FS received significantly higher scores for sharpness of lesion margin (4.4 vs 3.7; p = .03). CONCLUSION: Novel single-shot T2-weighted MRI with deep-learning-based image reconstruction demonstrated superior image quality compared with the standard T2-FS sequence for 3 T liver MRI, while being acquired in less than half the time.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador , Artefatos
9.
AJR Am J Roentgenol ; 219(6): 903-914, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35856454

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) is one of the most aggressive malignancies, with a dismal survival rate. Screening the general population for early detection of PDAC is not recommended, but because early detection improves survival, high-risk individuals, defined as those meeting criteria based on a family history of PDAC and/or the presence of known pathogenic germline variant genes with PDAC risk, are recommended to undergo screening with MRI and/or endoscopic ultrasound at regular intervals. The Pancreatic Cancer Early Detection (PRECEDE) Consortium was formed in 2018 and is composed of gastroenterologists, geneticists, pancreatic surgeons, radiologists, statisticians, and researchers from 40 sites in North America, Europe, and Asia. The overarching goal of the PRECEDE Consortium is to facilitate earlier diagnosis of PDAC for high-risk individuals to increase survival of the disease. A standardized MRI protocol and reporting template are needed to enhance the quality of screening examinations, improve consistency of clinical management, and facilitate multiinstitutional research. We present a consensus statement to standardize MRI screening and reporting for individuals with elevated risk of pancreatic cancer.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Detecção Precoce de Câncer , Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/genética , Imageamento por Ressonância Magnética , Padrões de Referência , Neoplasias Pancreáticas
10.
Eur Radiol ; 32(1): 34-45, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34120229

RESUMO

OBJECTIVES: To determine if golden-angle radial sparse parallel (GRASP) dynamic contrast-enhanced (DCE)-MRI allows simultaneous evaluation of perfusion and morphology in liver fibrosis. METHODS: Participants who were scheduled for liver biopsy or resection were enrolled (NCT02480972). Images were reconstructed at 12-s temporal resolution for morphologic assessment and at 3.3-s temporal resolution for quantitative evaluation. The image quality of the morphologic images was assessed on a four-point scale, and the Liver Imaging Reporting and Data System score was recorded for hepatic observations. Comparisons were made between quantitative parameters of DCE-MRI for the different fibrosis stages, and for hepatocellular carcinoma (HCCs) with different LR features. RESULTS: DCE-MRI of 64 participants (male = 48) were analyzed. The overall image quality consistently stood at 3.5 ± 0.4 to 3.7 ± 0.4 throughout the exam. Portal blood flow significantly decreased in participants with F2-F3 (n = 18, 175 ± 110 mL/100 mL/min) and F4 (n = 12, 98 ± 47 mL/100 mL/min) compared with those in participants with F0-F1 (n = 34, 283 ± 178 mL/100 mL/min, p < 0.05 for all). In participants with F4, the arterial fraction and extracellular volume were significantly higher than those in participants with F0-F1 and F2-F3 (p < 0.05). Compared with HCCs showing non-LR-M features (n = 16), HCCs with LR-M (n = 5) had a significantly prolonged mean transit time and lower arterial blood flow (p < 0.05). CONCLUSIONS: Liver MRI using GRASP obtains both sufficient spatial resolution for confident diagnosis and high temporal resolution for pharmacokinetic modeling. Significant differences were found between the MRI-derived portal blood flow at different hepatic fibrosis stages. KEY POINTS: A single MRI examination is able to provide both images with sufficient spatial resolution for anatomic evaluation and those with high temporal resolution for pharmacokinetic modeling. Portal blood flow was significantly lower in clinically significant hepatic fibrosis and mean transit time and extracellular volume increased in cirrhosis, compared with those in no or mild hepatic fibrosis. HCCs with different LR features showed different quantitative parameters of DCE-MRI: longer mean transit time and lower arterial flow were observed in HCCs with LR-M features.


Assuntos
Meios de Contraste , Neoplasias Hepáticas , Humanos , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Perfusão
11.
J Magn Reson Imaging ; 56(1): 184-195, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34877735

RESUMO

BACKGROUND: Early diagnosis and treatment of prostate cancer (PCa) can be curative; however, prostate-specific antigen is a suboptimal screening test for clinically significant PCa. While prostate magnetic resonance imaging (MRI) has demonstrated value for the diagnosis of PCa, the acquisition time is too long for a first-line screening modality. PURPOSE: To accelerate prostate MRI exams, utilizing a variational network (VN) for image reconstruction. STUDY TYPE: Retrospective. SUBJECTS: One hundred and thirteen subjects (train/val/test: 70/13/30) undergoing prostate MRI. FIELD STRENGTH/SEQUENCE: 3.0 T; a T2 turbo spin echo (TSE) T2-weighted image (T2WI) sequence in axial and coronal planes, and axial echo-planar diffusion-weighted imaging (DWI). ASSESSMENT: Four abdominal radiologists evaluated the image quality of VN reconstructions of retrospectively under-sampled biparametric MRIs (bp-MRI), and standard bp-MRI reconstructions for 20 test subjects (studies). The studies included axial and coronal T2WI, DWI B50 seconds/mm2 and B1000 seconds/mm (4-fold T2WI, 3-fold DWI), all of which were evaluated separately for image quality on a Likert scale (1: non-diagnostic to 5: excellent quality). In another 10 test subjects, three readers graded lesions on bp-MRI-which additionally included calculated B1500 seconds/mm2 , and apparent diffusion coefficient map-according to the Prostate Imaging Reporting and Data System (PI-RADS v2.1), for both VN and standard reconstructions. Accuracy of PI-RADS ≥3 for clinically significant cancer was computed. Projected scan time of the retrospectively under-sampled biparametric exam was also computed. STATISTICAL TESTS: One-sided Wilcoxon signed-rank test was used for comparison of image quality. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for lesion detection and grading. Generalized estimating equation with cluster effect was used to compare differences between standard and VN bp-MRI. A P-value of <0.05 was considered statistically significant. RESULTS: Three of four readers rated no significant difference for overall quality between the standard and VN axial T2WI (Reader 1: 4.00 ± 0.56 (Standard), 3.90 ± 0.64 (VN) P = 0.33; Reader 2: 4.35 ± 0.74 (Standard), 3.80 ± 0.89 (VN) P = 0.003; Reader 3: 4.60 ± 0.50 (Standard), 4.55 ± 0.60 (VN) P = 0.39; Reader 4: 3.65 ± 0.99 (Standard), 3.60 ± 1.00 (VN) P = 0.38). All four readers rated no significant difference for overall quality between standard and VN DWI B1000 seconds/mm2 (Reader 1: 2.25 ± 0.62 (Standard), 2.45 ± 0.75 (VN) P = 0.96; Reader 2: 3.60 ± 0.92 (Standard), 3.55 ± 0.82 (VN) P = 0.40; Reader 3: 3.85 ± 0.72 (Standard), 3.55 ± 0.89 (VN) P = 0.07; Reader 4: 4.70 ± 0.76 (Standard); 4.60 ± 0.73 (VN) P = 0.17) and three of four readers rated no significant difference for overall quality between standard and VN DWI B50 seconds/mm2 (Reader 1: 3.20 ± 0.70 (Standard), 3.40 ± 0.75 (VN) P = 0.98; Reader 2: 2.85 ± 0.81 (Standard), 3.00 ± 0.79 (VN) P = 0.93; Reader 3: 4.45 ± 0.72 (Standard), 4.05 ± 0.69 (VN) P = 0.02; Reader 4: 4.50 ± 0.69 (Standard), 4.45 ± 0.76 (VN) P = 0.50). In the lesion evaluation study, there was no significant difference in the number of PI-RADS ≥3 lesions identified on standard vs. VN bp-MRI (P = 0.92, 0.59, 0.87) with similar sensitivity and specificity for clinically significant cancer. The average scan time of the standard clinical biparametric exam was 11.8 minutes, and this was projected to be 3.2 minutes for the accelerated exam. DATA CONCLUSION: Diagnostic accelerated biparametric prostate MRI exams can be performed using deep learning methods in <4 minutes, potentially enabling rapid screening prostate MRI. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 5.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
12.
3D Print Med ; 7(1): 34, 2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34709482

RESUMO

Augmented reality (AR) and virtual reality (VR) are burgeoning technologies that have the potential to greatly enhance patient care. Visualizing patient-specific three-dimensional (3D) imaging data in these enhanced virtual environments may improve surgeons' understanding of anatomy and surgical pathology, thereby allowing for improved surgical planning, superior intra-operative guidance, and ultimately improved patient care. It is important that radiologists are familiar with these technologies, especially since the number of institutions utilizing VR and AR is increasing. This article gives an overview of AR and VR and describes the workflow required to create anatomical 3D models for use in AR using the Microsoft HoloLens device. Case examples in urologic oncology (prostate cancer and renal cancer) are provided which depict how AR has been used to guide surgery at our institution.

13.
Abdom Radiol (NY) ; 46(11): 5095-5104, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34324038

RESUMO

PURPOSE: To assess inter-reader agreement of key features from the SAR-AGA recommendations for the interpretation and reporting of MRE in adult patients with CD, focusing on the impact of radiologist experience on inter-reader agreement of CD phenotypes. METHODS: Two experienced and two less-experienced radiologists retrospectively evaluated 99 MRE in CD patients (50 initial MRE, 49 follow-up MRE) performed from 1/1/2019 to 3/20/2020 for the presence of active bowel inflammation (stomach, proximal small bowel, ileum, colon), stricture, probable stricture, penetrating disease, and perianal disease. The MRE protocol did not include dedicated perianal sequences. Inter-rater agreement was determined for each imaging feature using prevalence-adjusted bias-adjusted kappa and compared by experience level. RESULTS: All readers had almost-perfect inter-reader agreement (κ > 0.90) for penetrating disease, abscess, and perianal abscess in all 99 CD patients. All readers had strong inter-reader agreement (κ: 0.80-0.90) in 99 CD patients for active ileum inflammation, proximal small bowel inflammation, and stricture. Less-experienced readers had significantly lower inter-reader agreement for active ileum inflammation on initial than follow-up MRE (κ 0.68 versus 0.96, p = 0.018) and for strictures on follow-up than initial MRE (κ 0.76 versus 1.0, p = 0.027). Experienced readers had significantly lower agreement for perianal fistula on follow-up than initial MRE (κ: 0.55 versus 0.92, p = 0.008). CONCLUSION: There was strong to almost-perfect inter-reader agreement for key CD phenotypes described in the SAR-AGA consensus recommendations including active ileum and proximal small bowel inflammation, stricture, penetrating disease, abscess, and perianal abscess. Areas of lower inter-reader agreement could be targeted for future education efforts to further standardize CD MRE reporting. Dedicated perianal sequences should be included on follow-up MRE.


Assuntos
Doença de Crohn , Radiologia , Adulto , Consenso , Doença de Crohn/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Fenótipo , Radiologistas , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estados Unidos
14.
AJR Am J Roentgenol ; 217(5): 1132-1140, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33852355

RESUMO

BACKGROUND. Multiple commercial and open-source software applications are available for texture analysis. Nonstandard techniques can cause undesirable variability that impedes result reproducibility and limits clinical utility. OBJECTIVE. The purpose of this study is to measure agreement of texture metrics extracted by six software packages. METHODS. This retrospective study included 40 renal cell carcinomas with contrast-enhanced CT from The Cancer Genome Atlas and Imaging Archive. Images were analyzed by seven readers at six sites. Each reader used one of six software packages to extract commonly studied texture features. Inter- and intrareader agreement for segmentation was assessed with intraclass correlation coefficients (ICCs). First-order (available in six packages) and second-order (available in three packages) texture features were compared between software pairs using Pearson correlation. RESULTS. Inter- and intrareader agreement was excellent (ICC, 0.93-1). First-order feature correlations were strong (r ≥ 0.8, p < .001) between 75% (21/28) of software pairs for mean intensity and SD, 48% (10/21) for entropy, 29% (8/28) for skewness, and 25% (7/28) for kurtosis. Of 15 second-order features, only cooccurrence matrix correlation, gray-level nonuniformity, and run-length nonuniformity showed strong correlation between software packages (r = 0.90-1, p < .001). CONCLUSION. Variability in first- and second-order texture features was common across software configurations and produced inconsistent results. Standardized algorithms and reporting methods are needed before texture data can be reliably used for clinical applications. CLINICAL IMPACT. It is important to be aware of variability related to texture software processing and configuration when reporting and comparing outputs.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Software , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Software/normas
15.
Acad Radiol ; 28(3): 297-306, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33516590

RESUMO

RATIONALE AND OBJECTIVES: To determine the impact of COVID-19 workflow changes on patient throughput at the outpatient imaging facilities of a large healthcare system in New York City. MATERIALS AND METHODS: COVID-19 workflow changes to permit social distancing and patient and staff safety included screening at the time of scheduling, encouraging patients to use our digital platform to complete registration/safety forms prior to appointments, stationing screeners at all entrances, limiting waiting room capacity, implementing a texting system to notify patients of delays, limiting dressing room use by encouraging patients to wear exam-appropriate clothing, and accelerating MRI protocols without reducing image quality. We assessed patients' pre-exam wait times, MR exam times, overall time spent on site, and registration for and use of the digital portal before (February 2020) and after (June 2020) implementation of these measures. RESULTS: Across 17 outpatient imaging centers, workflow changes resulted in a 23.1% reduction (-6.8 minutes) in all patients' pre-exam wait times (p <0.00001). Pre-exam wait times for MRI, CT, ultrasound, x-ray, and mammography decreased 28.4% (-10.3 minutes), 16.5% (-6.7 minutes), 25.3% (-7.7 minutes), 22.8% (-3.7 minutes), and 23.9% (-5.0 minutes), respectively (p < 0.00001 for all). MR exam times decreased 9.7% (-3.5 minutes) and patients' overall time on site decreased 15.2% (-8.0 minutes). The proportions of patients actively using the digital patient portal (56.1%-70.1%) and completing forms electronically prior to arrival (24.9%-47.1%) increased (p < 0.0001 for both). CONCLUSION: Workflow changes necessitated by the COVID-19 pandemic to ensure safety of patients and staff have permitted higher outpatient throughput.


Assuntos
COVID-19 , Pacientes Ambulatoriais , Humanos , Cidade de Nova Iorque , Pandemias , SARS-CoV-2 , Fluxo de Trabalho
16.
Abdom Radiol (NY) ; 46(2): 703-722, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32809055

RESUMO

PURPOSE: There is substantial variation in the radiologic terms used to characterize renal masses, leading to ambiguity and inconsistency in clinical radiology reports and research studies. The purpose of this study was to develop a standardized lexicon to describe renal masses at CT and MRI. MATERIALS AND METHODS: This multi-institutional, prospective, quality improvement project was exempt from IRB oversight. Thirteen radiologists belonging to the Society of Abdominal Radiology (SAR) disease-focused panel on renal cell carcinoma representing nine academic institutions participated in a modified Delphi process to create a lexicon of terms used to describe imaging features of renal masses at CT and MRI. In the first round, members voted on terms to be included and proposed definitions; subsequent voting rounds and a teleconference established consensus. One non-voting member developed the questionnaire and consolidated responses. Consensus was defined as ≥ 80% agreement. RESULTS: Of 37 proposed terms, 6 had consensus to be excluded. Consensus for inclusion was reached for 30 of 31 terms (13/14 basic imaging terms, 8/8 CT terms, 6/6 MRI terms and 3/3 miscellaneous terms). Despite substantial initial disagreement about definitions of 'renal mass,' 'necrosis,' 'fat,' and 'restricted diffusion' in the first round, consensus for all was eventually reached. Disagreement remained for the definition of 'solid mass.' CONCLUSIONS: A modified Delphi method produced a lexicon of preferred terms and definitions to be used in the description of renal masses at CT and MRI. This lexicon should improve clarity and consistency of radiology reports and research related to renal masses.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Radiologia , Carcinoma de Células Renais/diagnóstico por imagem , Consenso , Humanos , Neoplasias Renais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos , Tomografia Computadorizada por Raios X
17.
3D Print Med ; 6(1): 33, 2020 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-33141272

RESUMO

PURPOSE: This study reports on the development of a novel 3D procedure planning technique to provide pre-ablation treatment planning for partial gland prostate cryoablation (cPGA). METHODS: Twenty men scheduled for partial gland cryoablation (cPGA) underwent pre-operative image segmentation and 3D modeling of the prostatic capsule, index lesion, urethra, rectum, and neurovascular bundles based upon multi-parametric MRI data. Pre-treatment 3D planning models were designed including virtual 3D cryotherapy probes to predict and plan cryotherapy probe configuration needed to achieve confluent treatment volume. Treatment efficacy was measured with 6 month post-operative MRI, serum prostate specific antigen (PSA) at 3 and 6 months, and treatment zone biopsy results at 6 months. Outcomes from 3D planning were compared to outcomes from a series of 20 patients undergoing cPGA using traditional 2D planning techniques. RESULTS: Forty men underwent cPGA. The median age of the cohort undergoing 3D treatment planning was 64.8 years with a median pretreatment PSA of 6.97 ng/mL. The Gleason grade group (GGG) of treated index lesions in this cohort included 1 (5%) GGG1, 11 (55%) GGG2, 7 (35%) GGG3, and 1 (5%) GGG4. Two (10%) of these treatments were post-radiation salvage therapies. The 2D treatment cohort included 20 men with a median age of 68.5 yrs., median pretreatment PSA of 6.76 ng/mL. The Gleason grade group (GGG) of treated index lesions in this cohort included 3 (15%) GGG1, 8 (40%) GGG2, 8 (40%) GGG3, 1 (5%) GGG4. Two (10%) of these treatments were post-radiation salvage therapies. 3D planning predicted the same number of cryoprobes for each group, however a greater number of cryoprobes was used in the procedure for the prospective 3D group as compared to that with 2D planning (4.10 ± 1.37 and 3.25 ± 0.44 respectively, p = 0.01). At 6 months post cPGA, the median PSA was 1.68 ng/mL and 2.38 ng/mL in the 3D and 2D cohorts respectively, with a larger decrease noted in the 3D cohort (75.9% reduction noted in 3D cohort and 64.8% reduction 2D cohort, p 0.48). In-field disease detection was 1/14 (7.1%) on surveillance biopsy in the 3D cohort and 3/14 (21.4%) in the 2D cohort, p = 0.056) In the 3D cohort, 6 month biopsy was not performed in 4 patients (20%) due to undetectable PSA, negative MRI, and negative MRI Axumin PET. For the group with traditional 2D planning, treatment zone biopsy was positive in 3/14 (21.4%) of the patients, p = 0.056. CONCLUSIONS: 3D prostate cancer models derived from mpMRI data provide novel guidance for planning confluent treatment volumes for cPGA and predicted a greater number of treatment probes than traditional 2D planning methods. This study prompts further investigation into the use of 3D treatment planning techniques as the increase of partial gland ablation treatment protocols develop.

18.
Eur Radiol ; 30(1): 370-382, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31385048

RESUMO

OBJECTIVES: The 8th International Forum for Liver Magnetic Resonance Imaging (MRI), held in Basel, Switzerland, in October 2017, brought together clinical and academic radiologists from around the world to discuss developments in and reach consensus on key issues in the field of gadoxetic acid-enhanced liver MRI since the previous Forum held in 2013. METHODS: Two main themes in liver MRI were considered in detail at the Forum: the use of gadoxetic acid for contrast-enhanced MRI in patients with liver cirrhosis and the technical performance of gadoxetic acid-enhanced liver MRI, both opportunities and challenges. This article summarises the expert presentations and the delegate voting on consensus statements discussed at the Forum. RESULTS AND CONCLUSIONS: It was concluded that gadoxetic acid-enhanced MRI has higher sensitivity for the diagnosis of hepatocellular carcinoma (HCC), when compared with multidetector CT, by utilising features of hyperenhancement in the arterial phase and hypointensity in the hepatobiliary phase (HBP). Recent HCC management guidelines recognise an increasing role for gadoxetic acid-enhanced MRI in early diagnosis and monitoring post-resection. Additional research is needed to define the role of HBP in predicting microvascular invasion, to better define washout during the transitional phase in gadoxetic acid-enhanced MRI for HCC diagnosis, and to reduce the artefacts encountered in the arterial phase. Technical developments are being directed to shortening the MRI protocol for reducing time and patient discomfort and toward utilising faster imaging and non-Cartesian free-breathing approaches that have the potential to improve multiphasic dynamic imaging. KEY POINTS: • Gadoxetic acid-enhanced MRI provides higher diagnostic sensitivity than CT for diagnosing HCC. • Gadoxetic acid-enhanced MRI has roles in early-HCC diagnosis and monitoring post-resection response. • Faster imaging and free-breathing approaches have potential to improve multiphasic dynamic imaging.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artefatos , Carcinoma Hepatocelular/patologia , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Tomografia Computadorizada Multidetectores , Suíça
19.
Abdom Radiol (NY) ; 45(3): 692-700, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31875241

RESUMO

PURPOSE: To compare liver stiffness measurements obtained from MR elastography with liver T1 relaxation times obtained from T1 mapping and T2 relaxation times obtained from T2 mapping for detection and staging of liver fibrosis. MATERIALS AND METHODS: 223 patients with known or suspected liver disease underwent MRI of the liver with T1 mapping (Look-Locker sequence) and 2D SE-EPI MR elastography (MRE) sequences. 139 of these patients also underwent T2 mapping with radial T2 TSE sequence. Two readers (R1 & R2) measured liver stiffness, T1 relaxation times and T2 relaxation times. T1 and T2 times were correlated with stiffness measurements. ROC analysis was used to compare the performance of both techniques in discriminating fibrosis stage in 23 patients who underwent liver biopsy. RESULTS: For each reader there was significant moderate positive correlation between liver MRE and liver T1 mapping (r = 0.49 and 0.36). There was significant moderate positive correlation between liver T2 mapping and each of MRE and T1 mapping for one of the readers (r = 0.40 and 0.27). AUC for differentiating early (F0-F2) from advanced (F3-F4) fibrosis in biopsied patients was 0.975 (R1) and 0.925 (R2) for MRE, 0.671 (R1) and 0.642 (R2) for T1 mapping and 0.671 (R1) and 0.743 (R2) for T2 mapping. Inter-reader agreement was good for MRE (ICC = 0.84) substantial for T1 mapping (0.94) and T2 mapping (0.96). CONCLUSIONS: Liver T1 and T2 mapping showed moderate positive correlation with MR elastography. Accuracy of MRE is however superior to T1 and T2 mapping in the subset of patients who underwent liver biopsy. Accuracy of combination of MRE and T1 mapping/T2 mapping was not superior to MRE alone.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Feminino , Humanos , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Abdom Radiol (NY) ; 44(9): 3040-3048, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31286208

RESUMO

PURPOSE: To compare qualitative results obtained from computer-aided dual-ratio analysis on T1-weighted two-point Dixon, with T2*-corrected multi-echo Dixon and T2-corrected multi-echo single-voxel MR spectroscopy sequence (MRS) for evaluation of liver fat and iron at 3T. METHODS AND MATERIALS: This retrospective, HIPAA-compliant, IRB-approved study included 479 patients with known or suspected liver disease. Two-point Dixon, multi-echo Dixon, and MR spectroscopy sequences were performed for each patient at 3T. A receiver-operating characteristic analysis was performed to compare the diagnostic performance in 80 patients using biopsy as the standard. Sensitivity, specificity, PPV, and NPV of qualitative two-point Dixon results, multi-echo Dixon (PDFF and R2*), and MRS (fat fraction and R2 water) for detection of hepatic steatosis and siderosis were assessed. RESULTS: Fat fractions obtained from MRS and multi-echo Dixon have equivalent accuracy for detection of hepatic steatosis (AUC, sensitivity and specificity: 0.90 vs 0.88, 0.77 vs. 0.82, and 0.90 vs. 0.82), but the optimal cutoff value is higher for MRS (6.05% vs. 3.4%). The dual-ratio Dixon discrimination technique showed high negative predictive value for detection of hepatic steatosis and siderosis (0.90 and 0.94, respectively). R2* from multi-echo Dixon and R2water from MRS have equivalent accuracy for detection of iron overload at 3T (AUC 0.89 vs. 0.88). The optimal cutoff for R2* and R2water are 60.5 s-1 and 40.85 s-1, respectively. CONCLUSION: The computer-aided dual-ratio discrimination with two-point Dixon is a useful qualitative screening tool with high negative predictive value for hepatic steatosis and iron overload. Multi-echo Dixon and MRS have similar accuracy for detection of hepatic steatosis and iron overload at 3 Tesla.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Sobrecarga de Ferro/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Avaliação como Assunto , Fígado Gorduroso/metabolismo , Humanos , Sobrecarga de Ferro/metabolismo , Fígado/diagnóstico por imagem , Fígado/metabolismo , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA