Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
3.
Circ Cardiovasc Interv ; 12(4): e007597, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30998397

RESUMO

BACKGROUND: The durability of transcatheter aortic bioprosthetic valves is a crucial issue, but data are scarce, especially beyond 5 years of follow-up. We aimed to assess long-term (7 years) structural valve deterioration (SVD) and bioprosthetic valve failure of transcatheter aortic bioprosthetic valves. METHODS AND RESULTS: Consecutive patients with at least 5-year follow-up available undergoing transcatheter aortic valve implantation from April 2002 to December 2011 in 5 French centers were included. Incidence of SVD and bioprosthetic valve failure were defined according to newly standardized criteria of the European Association of Percutaneous Cardiovascular Interventions/European Society of Cardiology/European Association for Cardio-Thoracic Surgery and reported as cumulative incidence function to account for the competing risk of death. One thousand four hundred three consecutive patients were included with a mean age of 82.6±7.5 years and with a mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) of 21.3±7.5%. A balloon-expandable valve was used in 83.7% of cases. Survival rates were 83.5% (95% CI, 81.4%-85.5%) and 18.6% (95% CI, 15.3%-21.8%) at 1 and 7 years, respectively. Median duration of follow-up was 3.9 years. Bioprosthetic valve failure occurred in 19 patients with a 7-year cumulative incidence of 1.9% (95% CI, 1.4%-2.4%). SVD occurred in 49 patients (moderate, n=32; severe, n=17) with a 7-year cumulative incidence of moderate and severe SVD of 7.0% (95% CI, 5.6%-8.4%) and 4.2% (95% CI, 2.9%-5.5%), respectively. Five patients had aortic valve reintervention (1.0%; 95% CI, 0.4%-1.6%) including 1 case of surgical aortic valve replacement and 4 redo-transcatheter aortic valve implantation. The incidences of SVD and bioprosthetic valve failure were not significantly different between balloon and self-expandable prostheses. CONCLUSIONS: The long-term assessment of transcatheter aortic bioprosthetic valves durability is limited by the poor survival of our population beyond 5 years. Further studies are warranted, particularly in younger and lower-risk patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
4.
Circ Cardiovasc Interv ; 11(11): e006388, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30571205

RESUMO

Background The optimal access for patients undergoing transcatheter aortic valve replacement (TAVR) who are not candidates for a transfemoral approach has not been elucidated. The purpose of this study was to compare the safety, feasibility, and early clinical outcomes of transcarotid TAVR compared with thoracic approaches. Methods and Results From a multicenter consecutive cohort of 329 alternative-access TAVR patients (2012-2017), we identified 101 patients who underwent transcarotid TAVR and 228 patients who underwent a transapical or transaortic TAVR. Preprocedural success and 30-day clinical outcomes were compared using multivariable propensity score analysis to account for between-group differences in baseline characteristics. All transcarotid cases were performed under general anesthesia, mainly using the left common carotid artery (97%). Propensity-matched groups had similar rates of 30-day all-cause mortality (2.1% versus 4.6%; P=0.37), stroke (2.1% versus 3.5%; P=0.67; transcarotid versus transapical/transaortic, respectively), new pacemaker implantation, and major vascular complications. Transcarotid TAVR was associated with significantly less new-onset atrial fibrillation (3.2% versus 19.0%; P=0.002), major or life-threatening bleeding (4.3% versus 19.9%; P=0.002), acute kidney injury (none versus 12.1%; P=0.002), and shorter median length of hospital stay (6 versus 8 days; P<0.001). Conclusions Transcarotid vascular access for TAVR is safe and feasible and is associated with encouraging short-term clinical outcomes. Our data suggest a clinical benefit of transcarotid TAVR with respect to atrial fibrillation, major bleeding, acute kidney injury, and length of stay compared with the more invasive transapical or transaortic strategies. Randomized studies are required to ascertain whether transcarotid TAVR yields equivalent results to other alternative vascular access routes.


Assuntos
Aorta , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Artéria Carótida Primitiva , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Canadá/epidemiologia , Artéria Carótida Primitiva/diagnóstico por imagem , Feminino , França/epidemiologia , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
Clin Cardiol ; 40(12): 1316-1322, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29247516

RESUMO

BACKGROUND: Coronary artery disease (CAD) is common in patients undergoing transcatheter aortic valve replacement (TAVR). However, the impact of CAD distribution before TAVR on short- and long-term prognosis remains unclear. HYPOTHESIS: We hypothesized that the long-term clinical impact differs according to CAD distribution in patients undergoing TAVR using the FRench Aortic National CoreValve and Edwards (FRANCE-2) registry. METHODS: FRANCE-2 is a national French registry including all consecutive TAVR performed between 2010 and 2012 in 34 centers. Three-year mortality was assessed in relation to CAD status. CAD was defined as at least 1 coronary stenosis >50%. RESULTS: A total of 4201 patients were enrolled in the registry. For the present analysis, we excluded patients with a history of coronary artery bypass. CAD was reported in 1252 patients (30%). Half of the patients presented with coronary multivessel disease. CAD extent was associated with an increase in cardiovascular risk profile and in logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) (from 19.3% ± 12.8% to 21.9% ± 13.5%, P < 0.001). Mortality at 30 days and 3 years was 9% and 44%, respectively, in the overall population. In multivariate analyses, neither the presence nor the extent of CAD was associated with mortality at 3 years (presence of CAD, hazard ratio [HR]: 0.90; 95% confidence interval [CI]: 0.78-1.07). A significant lesion of the left anterior descending (LAD) was associated with higher 3-year mortality (HR: 1.42; 95% CI: 1.10-1.87). CONCLUSIONS: CAD is not associated with decreased short- and long-term survival in patients undergoing TAVR. The potential deleterious effect of LAD disease on long-term survival and the need for revascularization before or at the time of TAVR should be validated in a randomized control trial.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ponte de Artéria Coronária , Doença da Artéria Coronariana/complicações , Sistema de Registros , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/epidemiologia , Angiografia Coronária , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Resultado do Tratamento
8.
Arch Cardiovasc Dis ; 102(10): 677-83, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19913769

RESUMO

BACKGROUND: The use of the internal thoracic artery for coronary artery bypass has improved the results of such surgery. However, bypass using only the internal thoracic arteries sometimes requires a T-graft. This purely internal thoracic artery T-graft technique has progressively become part of our surgical protocol for coronary artery bypass surgery. AIMS: The aim of the study was to analyse the impact of this surgical technique on the degree and quality of coronary revascularization using early postoperative angiography. METHODS: Between January 2004 and December 2006, 148 patients underwent coronary artery bypass surgery exclusively using both internal thoracic arteries in a T-graft configuration. Systematic postoperative angiography was offered to all 148 patients; it was accepted by 108 patients and refused by 40 patients. RESULTS: There were no statistically significant differences between the two groups. In-patient mortality was 2.02% (n=3) for the whole population studied, and 1.49% (n=2) for the 134 patients who received only coronary artery bypass grafts. The revascularization rate was 89% and 3.46 coronary anastomoses were constructed per patient (range 2-6). Angiography was performed on 108 right internal thoracic artery to left internal thoracic artery anastomoses, 374 anastomoses of internal thoracic arteries to coronary arteries and 382 inter-anastomosis segments: 98% of the anastomoses and segments were patent. CONCLUSION: The exclusive recourse to the purely internal thoracic artery T-graft technique meant that it has been possible to dispense with other types of graft while achieving complete and effective revascularization of the coronary artery.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária/métodos , Estenose Coronária/cirurgia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Artéria Torácica Interna/cirurgia , Grau de Desobstrução Vascular , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Estenose Coronária/fisiopatologia , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Artéria Torácica Interna/diagnóstico por imagem , Artéria Torácica Interna/fisiopatologia , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA