Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Ophthalmology ; 130(4): 433-442, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36529572

RESUMO

PURPOSE: To review the current published literature on the utility of corneal hysteresis (CH) to assist the clinician in the diagnosis of glaucoma or in the assessment of risk for disease progression in existing glaucoma patients. METHODS: Searches of the peer-reviewed literature in the PubMed database were performed through July 2022. The abstracts of 423 identified articles were examined to exclude reviews and non-English articles. After inclusion and exclusion criteria were applied, 19 articles were selected, and the panel methodologist rated them for level of evidence. Eight articles were rated level I, and 5 articles were rated level II. The 6 articles rated level III were excluded. RESULTS: Corneal hysteresis is lower in patients with primary open-angle glaucoma, primary angle-closure glaucoma, pseudoexfoliative glaucoma, and pseudoexfoliation syndrome compared with normal subjects. Interpretation of low CH in patients with high intraocular pressure (IOP) or on topical hypotensive medications is complicated by the influence of these parameters on CH measurements. However, CH is also lower in treatment-naïve, normal-tension glaucoma patients compared with normal subjects who have a similar IOP. In addition, lower CH is associated with an increased risk of progression of glaucoma based on visual fields or structural markers in open-angle glaucoma patients, including those with apparently well-controlled IOP. CONCLUSIONS: Corneal hysteresis is lower in glaucoma patients compared with normal subjects, and lower CH is associated with an increased risk of disease progression. However, a causal relationship remains to be demonstrated. Nevertheless, measurement of CH complements current structural and functional assessments in determining disease risk in glaucoma suspects and patients. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Humanos , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Progressão da Doença , Elasticidade , Glaucoma/diagnóstico , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular , Tonometria Ocular , Estados Unidos
2.
Am J Ophthalmol Case Rep ; 27: 101638, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35813588

RESUMO

Purpose: To report two pediatric cases of reticular corneal epithelial edema associated with the use of netarsudil ophthalmic solution 0.02%. Observations: In Case 1, a six-year-old male with glaucoma following cataract surgery was treated with netarsudil for thirteen months and developed diffuse reticular corneal epithelial edema on post-operative day one after undergoing transscleral diode cyclophotocoagulation for persistently elevated intraocular pressures. In Case 2, a three-month-old male with bilateral ocular hypertension developed unilateral inferior reticular corneal epithelial edema five weeks after initiation of netarsudil, which had been discontinued in the fellow eye two weeks prior. In both cases, the reticular epithelial edema resolved following cessation of netarsudil. Conclusions and Importance: Netarsudil-associated reticular corneal epithelial edema can occur in infants and young children.

4.
Curr Opin Ophthalmol ; 33(2): 103-111, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34864763

RESUMO

PURPOSE OF REVIEW: To summarize the literature on three-dimensional (3D) technological advances in ophthalmology, the quantitative methods associated with this, and their improved ability to help detect glaucoma disease progression. RECENT FINDINGS: Improvements in measuring glaucomatous structural changes are the result of dual innovations in optical coherence tomography (OCT) imaging technology and in associated quantitative software. SUMMARY: Compared with two-dimensional (2D) OCT parameters, newer 3D parameters provide more data and fewer artifacts.


Assuntos
Glaucoma , Oftalmologia , Glaucoma/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Tecnologia , Tomografia de Coerência Óptica
5.
Ophthalmology ; 128(8): 1222-1235, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33632585

RESUMO

PURPOSE: To review the current published literature on the use of OCT angiography (OCTA) to help detect changes associated with the diagnosis of primary open-angle glaucoma. METHODS: Searches of the peer-reviewed literature were conducted in March 2018, June 2018, April 2019, December 2019, and June 2020 in the PubMed and Cochrane Library databases. Abstracts of 459 articles were examined to exclude reviews and non-English articles. After inclusion and exclusion criteria were applied, 75 articles were selected and the panel methodologist rated them for strength of evidence. Three articles were rated level I and 57 articles were rated level II. The 15 level III articles were excluded. RESULTS: OCT angiography can detect decreased capillary vessel density within the peripapillary nerve fiber layer (level II) and macula (level I and II) in patients with suspected glaucoma, preperimetric glaucoma, and perimetric glaucoma. The degree of vessel density loss correlates significantly with glaucoma severity both overall and topographically (level II) as well as longitudinally (level I). For differentiating glaucomatous from healthy eyes, some studies found that peripapillary and macular vessel density measurements by OCTA show a diagnostic ability (area under the receiver operating characteristic curve) that is comparable with structural OCT retinal nerve fiber and ganglion cell thickness measurements, whereas other studies found that structural OCT measurements perform better. Choroidal or deep-layer microvasculature dropout as measured by OCTA is also associated with glaucoma damage (level I and II). Lower peripapillary and macular vessel density and choroidal microvasculature dropout are associated with faster rates of disease progression (level I and II). CONCLUSIONS: Vessel density loss associated with glaucoma can be detected by OCTA. Peripapillary, macular, and choroidal vessel density parameters may complement visual field and structural OCT measurements in the diagnosis of glaucoma.


Assuntos
Angiofluoresceinografia , Glaucoma de Ângulo Aberto/diagnóstico , Oftalmologia/organização & administração , Vasos Retinianos/fisiologia , Tomografia de Coerência Óptica , Academias e Institutos , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Fibras Nervosas/patologia , Disco Óptico/irrigação sanguínea , Estudos Prospectivos , Curva ROC , Células Ganglionares da Retina/patologia , Avaliação da Tecnologia Biomédica/métodos
6.
Ophthalmology ; 126(9): 1315-1323, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30953743

RESUMO

PURPOSE: To review the published literature on the use of swept-source (SS) OCT for evaluating the lamina cribrosa in glaucoma. METHODS: A PubMed and Cochrane Library literature search initially conducted on March 3, 2017, and updated on June 26, 2018, yielded a total of 64 articles. Articles that were reviews or that were not published in English were excluded, and 29 were found to fit the inclusion criteria. The panel methodologist then assigned a level of evidence rating to each study. Fifteen studies were rated level III, 14 studies were rated level II, and no studies were rated level I. RESULTS: Different aspects of the lamina cribrosa were studied using SS-OCT, including the anterior lamina cribrosa curvature, anterior lamina cribrosa depth, anterior lamina cribrosa insertions, laminar thickness, focal lamina cribrosa defects (FLCDs), and lamina cribrosa microarchitecture. In general, imaging of the anterior lamina can be achieved reliably, although shadowing from blood vessels at the neuroretinal rim remains an issue. Imaging of the posterior lamina can be achieved with varying levels of success. In glaucoma, there is posterior migration of the anterior lamina cribrosa insertions as well as increased thinning and posterior curvature of the lamina cribrosa. Focal lamina cribrosa defects appear more commonly in glaucoma, and this may hint at the pathogenesis of axonal damage. In addition, there may be remodeling of the microarchitecture of the lamina, resulting in more variable laminar pores. There are limited studies comparing SS-OCT with spectral-domain (SD) OCT with regard to imaging of the lamina, but the difference in image quality between enhanced depth imaging (EDI) with SD-OCT and SS-OCT seems minimal. CONCLUSIONS: Imaging of the lamina cribrosa using SS-OCT has demonstrated that the lamina cribrosa is likely biomechanically active and that significant changes occur in glaucoma. The diagnostic utility of SS-OCT for lamina cribrosa imaging is promising, but standardized nomenclature, automated measurements, and longitudinal studies with larger and more diverse sample sizes are needed.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico por imagem , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico por imagem , Avaliação da Tecnologia Biomédica , Tomografia de Coerência Óptica/métodos , Academias e Institutos/organização & administração , Bases de Dados Factuais , Humanos , Fibras Nervosas/patologia , Oftalmologia/organização & administração , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Estados Unidos
7.
J Glaucoma ; 28(5): 473-480, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30839415

RESUMO

PRéCIS:: This retrospective study found that combined phacoemulsification and endocyclophotocoagulation reduced intraocular pressure (IOP) to a greater degree in angle-closure glaucoma versus open-angle glaucoma and was effective for all stages of glaucoma. PURPOSE: Endocyclophotocoagulation (ECP) laser treatment of the ciliary processes is believed to decrease IOP by reducing aqueous production. Anecdotal experience in angle-closure glaucoma suggests that it may also lower IOP by opening the drainage angle to promote aqueous outflow. This study sought to evaluate combined phacoemulsification and ECP (phaco/ECP) in eyes with different types and stages of glaucoma. PATIENTS AND METHODS: A Retrospective chart review of eyes that underwent phaco/ECP between October 2010 and December 2016 at one institution was conducted. RESULTS: In 63 eyes of 63 patients with an average of 3.0±1.7 years of follow-up, the 22 eyes with chronic angle-closure glaucoma (CACG) had greater IOP reduction and medication reduction than the 41 eyes with primary open-angle glaucoma at both 1 year (6.4 vs. 2.1 mm Hg, P=0.01; 0.9 vs. 0.2 medications, P=0.04) and final follow-up (6.2 vs. 2.4 mm Hg, P=0.02; 0.9 vs. 0.3 medications, P=0.05). There was no difference in IOP reduction or medication reduction for eyes with mild, moderate, or advanced glaucoma at both 1 year (3.5, 3.9, 0.5 mm Hg, respectively, P=0.18; 0.3, 0.6, 0.4 medications, P=0.58) and final follow-up (3.3, 4.8, 0.7 mm Hg, P=0.11; 0.1, 0.8, 0.4 medications, P=0.14). CONCLUSIONS: Eyes with CACG were more responsive to phaco/ECP in terms of IOP and medication reduction compared with eyes with primary open-angle glaucoma. This finding could be partially or entirely due to concurrent cataract extraction and greater CACG preoperative IOP. Phaco/ECP was effective in all stages of glaucoma.


Assuntos
Endoscopia/métodos , Glaucoma de Ângulo Fechado/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Terapia a Laser/métodos , Facoemulsificação/métodos , Idoso , Idoso de 80 Anos ou mais , Corpo Ciliar/cirurgia , Terapia Combinada , Endoscopia/efeitos adversos , Feminino , Glaucoma de Ângulo Fechado/patologia , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Aberto/patologia , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular , Terapia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Facoemulsificação/efeitos adversos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Tonometria Ocular , Resultado do Tratamento
8.
J Surg Educ ; 76(1): 150-157, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30131282

RESUMO

OBJECTIVES: To evaluate the impact of a comprehensive cataract surgery curriculum on the incidence of intraoperative complications. DESIGN: We retrospectively compared the total number of cataract surgeries that the residents performed in all of the teaching sites, and the incidences of intraoperative complications (anterior capsule tear, posterior capsule rent, vitreous loss, anterior vitrectomy, zonular dialysis, iris trauma, hemorrhage, dropped lens fragment, corneal wound burn, incorrect intraocular lens) for the surgeries performed at Massachusetts Eye & Ear by residents in the pre-intervention group (residents graduating in 2004 and 2005), before the implementation of a surgical curriculum, and the residents in the post-intervention group (residents graduating in 2014 and 2015). SETTING: Ophthalmology residency program at a major academic institution. PARTICIPANTS: Residents graduating in 2004, 2005, 2014, and 2015. RESULTS: We reviewed 4373 charts. 2086 of those surgeries were performed at Massachusetts Eye & Ear. The incidence of posterior capsule rent/vitreous loss/anterior vitrectomy was lower in the post-intervention group (1.4% versus 7.7%, p < 0.0001). Other complications were also lower in the post-intervention group. CONCLUSIONS: Implementation of a comprehensive cataract surgery curriculum focusing on pre-operative, intra-operative and post-operative interventions, with an emphasis on patient outcomes resulted in a decrease in the rate of intraoperative complications.


Assuntos
Extração de Catarata/educação , Competência Clínica , Currículo , Internato e Residência , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/prevenção & controle , Oftalmologia/educação , Humanos , Incidência , Massachusetts , Estudos Retrospectivos
9.
Ophthalmology ; 126(4): 611-622, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30472176

RESUMO

PURPOSE: To assess the effect of intravitreal injections of anti-vascular endothelial growth factor (VEGF) agents on immediate and long-term intraocular pressure (IOP) elevation and glaucoma. METHODS: Literature searches of the PubMed and Cochrane databases, last conducted in April 2018, yielded 253 unique citations. Of these, 41 met the inclusion criteria and were rated according to the strength of evidence. Two articles were rated level I, 17 were rated level II, and 15 were rated level III; an additional 7 were excluded because of poor study design and lack of relevance to the topic under evaluation. RESULTS: The studies that reported on short-term IOP elevation (i.e., between 0 and 60 minutes) showed that an immediate increase in IOP is seen in all patients when measured between 0 and 30 minutes of intravitreal injection and that the IOP elevation decreases over time. The data on long-term IOP elevation were mixed; 7 studies reported that between 4% and 15% of patients developed sustained elevation of IOP at 9 to 24 months after injection, whereas 6 studies found no long-term change in IOP from 1 to 36 months after injection. Pretreatment with glaucoma medications, anterior chamber tap, vitreous reflux, longer intervals between injections, and longer axial lengths were associated with lower IOP elevations after injection. Data were mixed on the relationship between IOP increase and the type of intravitreal injection, number of intravitreal injections, preexisting glaucoma, and globe decompression before injection. There were no data on the onset or progression of glaucoma in the studies reviewed in this assessment. CONCLUSIONS: Intravitreal injection of anti-VEGF agents results in an immediate and transient increase in IOP. A long-term increase in IOP also may be seen, and further studies are needed to determine at-risk populations. Although there is some suggestion in the literature, there is currently insufficient data to determine the impact of intravitreal anti-VEGF injections on glaucoma progression. Although pretreatment with glaucoma medications, performing anterior chamber paracentesis, or increasing the interval between injections may reduce the impact of transient IOP elevation, the clinical significance and associated risks of these interventions are unknown.


Assuntos
Inibidores da Angiogênese/farmacologia , Glaucoma/fisiopatologia , Pressão Intraocular/efeitos dos fármacos , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Academias e Institutos/organização & administração , Bases de Dados Factuais , Glaucoma/diagnóstico , Humanos , Pressão Intraocular/fisiologia , Injeções Intravítreas , Avaliação da Tecnologia Biomédica , Estados Unidos
10.
Ophthalmology ; 125(11): 1817-1827, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30322450

RESUMO

PURPOSE: To review the current published literature on the use of spectral domain (SD) OCT to help detect changes associated with the diagnosis of glaucoma. METHODS: Searches of the peer-reviewed literature were conducted on June 11, 2014, November 7, 2016, August 8, 2017, and April 19, 2018, in the PubMed and Cochrane Library databases and included only articles published since the last glaucoma imaging Ophthalmic Technology Assessment, which included articles up until February 2006. The abstracts of these 708 articles were examined to exclude reviews and non-English articles. After inclusion and exclusion criteria were applied, 74 articles were selected, and the panel methodologist (K.N.-M.) assigned ratings to them according to the level of evidence. Two articles were rated level I, 57 articles were rated level II, and the 15 level III articles were excluded. RESULTS: Spectral-domain OCT is capable of detecting damage to the retinal nerve fiber layer (RNFL), macula, and optic nerve in patients with preperimetric and perimetric glaucoma (level I and II evidence). The most commonly studied single parameter was RNFL thickness. Of note, RNFL thickness measurements are not interchangeable between instruments. Various commercially available SD OCT instruments have similar abilities to distinguish patients with known glaucoma from normal subjects. Despite different software protocols, all SD OCT instruments are able to detect the same typical pattern of glaucomatous RNFL loss that affects primarily the inferior, inferior temporal, superior, and superior temporal regions of the optic nerve (level II evidence). Across many SD OCT instruments, macular imaging also can detect a preferential inferior, inferior temporal, and superior temporal thinning in patients with glaucoma compared with controls. Best disc parameters for detecting glaucomatous nerve damage are global rim area, inferior rim area, and vertical cup-to-disc ratio. Studies suggest that newer reference-plane independent optic nerve parameters may have the same or better detection capability when compared with older reference-plane dependent disc parameters (level II evidence). CONCLUSIONS: Structural glaucomatous damage can be detected by SD OCT. Optic nerve, RNFL, and macular parameters can help the clinician distinguish the anatomic changes that are associated with patients with glaucoma when compared with normal subjects.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico por imagem , Fibras Nervosas/patologia , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico por imagem , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Academias e Institutos/organização & administração , Bases de Dados Factuais , Humanos , Oftalmologia/organização & administração , Avaliação da Tecnologia Biomédica , Estados Unidos
12.
Ophthalmology ; 125(7): 1110-1120, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29482864

RESUMO

PURPOSE: To examine the efficacy and complications of laser peripheral iridotomy (LPI) in subjects with primary angle closure (PAC). METHODS: Literature searches in the PubMed and Cochrane databases were last conducted in August 2017 and yielded 300 unique citations. Of these, 36 met the inclusion criteria and were rated according to the strength of evidence; 6 articles were rated level I, 11 articles were rated level II, and 19 articles were rated level III. RESULTS: Reported outcomes were change in angle width, effect on intraocular pressure (IOP) control, disease progression, and complications. Most of the studies (29/36, 81%) included only Asian subjects. Angle width (measured by gonioscopy, ultrasound biomicroscopy, and anterior segment OCT) increased after LPI in all stages of angle closure. Gonioscopically defined persistent angle closure after LPI was reported in 2% to 57% of eyes across the disease spectrum. Baseline factors associated with persistent angle closure included narrower angle and parameters representing nonpupillary block mechanisms of angle closure, such as a thick iris, an anteriorly positioned ciliary body, or a greater lens vault. After LPI, further treatment to control IOP was reported in 0%-8% of PAC suspect (PACS), 42% to 67% of PAC, 21% to 47% of acute PAC (APAC), and 83%-100% of PAC glaucoma (PACG) eyes. Progression to PACG ranged from 0% to 0.3% per year in PACS and 0% to 4% per year in PAC. Complications after LPI included IOP spike (8-17 mmHg increase from baseline in 6%-10%), dysphotopsia (2%-11%), anterior chamber bleeding (30%-41%), and cataract progression (23%-39%). CONCLUSIONS: Laser peripheral iridotomy increases angle width in all stages of primary angle closure and has a good safety profile. Most PACS eyes do not receive further intervention, whereas many PAC and APAC eyes, and most PACG eyes, receive further treatment. Progression to PACG is uncommon in PACS and PAC. There are limited data on the comparative efficacy of LPI versus other treatments for the various stages of angle closure; 1 randomized controlled trial each demonstrated superiority of cataract surgery over LPI in APAC and of clear lens extraction over LPI in PACG or PAC with IOP above 30 mmHg.


Assuntos
Glaucoma de Ângulo Fechado/cirurgia , Iridectomia/métodos , Iris/cirurgia , Terapia a Laser/métodos , Avaliação da Tecnologia Biomédica , Academias e Institutos/organização & administração , Idoso , Bases de Dados Factuais , Progressão da Doença , Feminino , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/fisiopatologia , Gonioscopia , Humanos , Pressão Intraocular/fisiologia , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Oftalmologia/organização & administração , Resultado do Tratamento
13.
Ophthalmology ; 124(12): 1867-1875, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28705429

RESUMO

OBJECTIVE: To examine the efficacy of various disinfection methods for reusable tonometer prisms in eye care and to highlight how disinfectants can damage tonometer tips and cause subsequent patient harm. METHODS: Literature searches were conducted last in October 2016 in the PubMed and the Cochrane Library databases for original research investigations. Reviews, non-English language articles, nonophthalmology articles, surveys, and case reports were excluded. RESULTS: The searches initially yielded 64 unique citations. After exclusion criteria were applied, 10 laboratory studies remained for this review. Nine of the 10 studies used tonometer prisms and 1 used steel discs. The infectious agents covered in this assessment include adenovirus 8 and 19, herpes simplex virus (HSV) 1 and 2, human immunodeficiency virus 1, hepatitis C virus, enterovirus 70, and variant Creutzfeldt-Jakob disease. All 4 studies of adenovirus 8 concluded that after sodium hypochlorite (dilute bleach) disinfection, the virus was undetectable, but only 2 of the 4 studies found that 70% isopropyl alcohol (e.g., alcohol wipes or soaks) eradicated all viable virus. All 3 HSV studies concluded that both sodium hypochlorite and 70% isopropyl alcohol eliminated HSV. Ethanol, 70% isopropyl alcohol, dilute bleach, and mechanical cleaning all lack the ability to remove cellular debris completely, which is necessary to prevent prion transmission. Therefore, single-use tonometer tips or disposable tonometer covers should be considered when treating patients with suspected prion disease. Damage to tonometer prisms can be caused by sodium hypochlorite, 70% isopropyl alcohol, 3% hydrogen peroxide, ethyl alcohol, water immersion, ultraviolet light, and heat exposure. Disinfectants can cause tonometer tips to swell and crack by dissolving the glue that holds the hollow tip together. The tonometer tip cracks can irritate the cornea, harbor microbes, or allow disinfectants to enter the interior of the tonometer tip. CONCLUSIONS: Sodium hypochlorite (dilute bleach) offers effective disinfection against adenovirus and HSV, the viruses commonly associated with nosocomial outbreaks in eye care. Tonometer prisms should be examined regularly for signs of damage.


Assuntos
Desinfecção/métodos , Tonometria Ocular/instrumentação , Academias e Institutos/organização & administração , Anti-Infecciosos/farmacologia , Infecção Hospitalar/prevenção & controle , Desinfetantes/farmacologia , Humanos , Oftalmologia/organização & administração , Avaliação da Tecnologia Biomédica , Estados Unidos
14.
Ophthalmology ; 124(1): 27-35, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27538795

RESUMO

PURPOSE: To report the long-term visual outcomes and complications after Boston keratoprosthesis type II implantation in the largest single-center case series with the longest average follow-up. DESIGN: Retrospective review of consecutive clinical case series. PARTICIPANTS: Between January 1992 and April 2015 at the Massachusetts Eye and Ear Infirmary, 48 eyes of 44 patients had keratoprosthesis type II implanted by 2 surgeons (C.H.D. and J.C.). METHODS: For each eye, data were collected and analyzed on the preoperative characteristics, intraoperative procedures, and postoperative course. MAIN OUTCOME MEASURES: Visual acuity outcomes, postoperative complications, and device retention. RESULTS: The most common indications for surgery were Stevens-Johnson syndrome in 41.7% (20 of 48 eyes) and mucous membrane pemphigoid in 41.7% (20 of 48 eyes). Mean follow-up duration was 70.2 months (standard deviation, 61.8 months; median, 52 months; range, 6 months to 19.8 years). Almost all patients (95.8%, 46 of 48 eyes) had a preoperative visual acuity of 20/200 or worse. Postoperative visual acuity improved to 20/200 or better in 37.5% (18 of 48 eyes) and to 20/100 or better in 33.3% (16 of 48 eyes) at the last follow-up visit. The most common postoperative complication was retroprosthetic membrane formation in over half (60.4%, 29 of 48 eyes). The most pressing postoperative complication was glaucoma onset or progression in about a third. Preexisting glaucoma was present in 72.9% (35 of 48 eyes). Glaucoma progressed in 27.1% (13 of 48 eyes) and was newly diagnosed in 8.3% (4 of 48 eyes) after surgery. Other postoperative complications were tarsorrhaphy revision in 52.1% (25 of 48 eyes), retinal detachment in 18.8% (9 of 48 eyes), infectious endophthalmitis in 6.3% (3 of 48 eyes), and choroidal detachment or hemorrhage in 8.3% (4 of 48 eyes). Half of eyes retained their initial keratoprosthesis at the last follow-up (50.0%, 24 of 48 eyes). CONCLUSIONS: The Boston keratoprosthesis type II is a viable option to salvage vision in patients with poor prognosis for other corneal procedures. Retroprosthetic membranes, keratoprosthesis retention, and glaucoma are major challenges in the postoperative period; however, the keratoprosthesis can still provide improved vision in a select group of patients.


Assuntos
Órgãos Artificiais , Doenças da Córnea/cirurgia , Próteses e Implantes , Implantação de Prótese/estatística & dados numéricos , Adulto , Idoso , Feminino , Seguimentos , Glaucoma/cirurgia , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Retenção da Prótese/estatística & dados numéricos , Estudos Retrospectivos , Acuidade Visual
16.
J Glaucoma ; 25(8): e759-60, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27483333

RESUMO

We report a case of juvenile xanthogranuloma in a 12-month-old girl presenting with heterochromia, hyphema, and elevated intraocular pressure. This case demonstrates new ultrasound biomicroscopy iris findings of a generalized bumpy iris contour, suggesting diffuse heterogeneous involvement. This imaging finding has not been previously described. Untreated, iris juvenile xanthogranuloma may lead to corneal blood staining, glaucoma, and amblyopia. An understanding of the full range of ultrasound features of juvenile xanthogranuloma expands our appreciation for the clinical findings in this condition.


Assuntos
Doenças da Íris/diagnóstico , Iris/diagnóstico por imagem , Microscopia Acústica/métodos , Xantogranuloma Juvenil/diagnóstico , Criança , Feminino , Humanos , Pressão Intraocular/fisiologia
17.
J Surg Educ ; 73(5): 774-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27211876

RESUMO

OBJECTIVES: To assess resident cataract surgery outcomes at an academic teaching institution using 2 Physician Quality Reporting System (PQRS) cataract measures, which are intended to serve as a proxy for quality of surgical care. DESIGN: A retrospective review comparing cataract surgery outcomes of resident and attending surgeries using 2 PQRS measures: (1) 20/40 or better best-corrected visual acuity following cataract surgery and (2) complications within 30 days following cataract surgery requiring additional surgical procedures. SETTING: An academic ophthalmology center. PARTICIPANTS: A total of 2487 surgeries performed at the Massachusetts Eye and Ear Infirmary from January 1, 2011 to December 31, 2012 were included in this study. RESULTS: Of all 2487 cataract surgeries, 98.95% achieved a vision of at least 20/40 at or before 90 days, and only 0.64% required a return to the operating room for postoperative complications. Of resident surgeries, 98.9% (1370 of 1385) achieved 20/40 vision at or before 90 days follow-up. Of attending surgeries, 99.0% (1091 of 1102) achieved 20/40 vision at or before 90 days (p = 1.00). There were no statistically significant differences between resident and attending cases regarding postoperative complications needing a return to the operating room (i.e., 0.65%, or 9 of 1385 resident cases vs 0.64%, or 7 of 1102 attending cases; p = 1.00). CONCLUSIONS: Using PQRS Medicare cataract surgery criteria, this study establishes new benchmarks for cataract surgery outcomes at a teaching institution and supplemental measure for assessing resident surgical performance. Excellent cataract outcomes were achieved at an academic teaching institution, with results exceeding Medicare thresholds of 50%. There appears to be no significant difference in supervised trainee and attending cataract surgeon outcomes using 2 PQRS measures currently used by Medicare to determine physician reimbursement and quality of care.


Assuntos
Extração de Catarata/educação , Competência Clínica , Educação de Pós-Graduação em Medicina , Oftalmologia/educação , Avaliação de Resultados em Cuidados de Saúde , Benchmarking , Feminino , Humanos , Internato e Residência , Masculino , Massachusetts , Complicações Pós-Operatórias , Estudos Retrospectivos , Acuidade Visual
18.
Ocul Oncol Pathol ; 2(3): 166-70, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27239459

RESUMO

BACKGROUND/AIM: Unilateral choroidal infiltration as the initial manifestation of leukemic relapse in adults is rare, particularly after an extended period of remission. This report describes this unique ophthalmic presentation, highlights the associated diagnostic challenges, and reviews the literature. METHODS: Two cases are described and an extensive literature review was conducted. RESULTS: A 59-year-old male with acute lymphoid leukemia, in remission for 18 months, presented with unilateral scleritis, exudative retinal detachment, and choroidal thickening. A 57-year-old male with a history of acute myeloid leukemia, in remission for 4 years, presented with unilateral choroidal thickening leading to secondary angle closure. In both cases, there was a significant lag from the onset of eye symptoms to establishing a systemic diagnosis of acute leukemia, leading to a delay in definitive systemic treatment, despite a high suspicion of disease based on ophthalmic findings. CONCLUSIONS: These two cases illustrate the fundus findings consistent with leukemic choroidal infiltration that can represent the first sign of relapsed leukemia. The successful treatment of these patients hinges on collaboration between ophthalmologists and oncologists to optimize patient outcomes, highlighting the need for both groups to be aware of this rare ophthalmic presentation.

19.
Ophthalmology ; 122(7): 1294-307, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25943711

RESUMO

OBJECTIVE: To examine effects of phacoemulsification on longer-term intraocular pressure (IOP) in patients with medically treated primary open-angle glaucoma (POAG; including normal-tension glaucoma), pseudoexfoliation glaucoma (PXG), or primary angle-closure glaucoma (PACG), without prior or concurrent incisional glaucoma surgery. METHODS: PubMed and Cochrane database searches, last conducted in December 2014, yielded 541 unique citations. Panel members reviewed titles and abstracts and selected 86 for further review. The panel reviewed these articles and identified 32 studies meeting the inclusion criteria, for which the panel methodologist assigned a level of evidence based on standardized grading adopted by the American Academy of Ophthalmology. One, 15, and 16 studies were rated as providing level I, II, and III evidence, respectively. RESULTS: All follow-up, IOP, and medication data listed are weighted means. In general, the studies reported on patients using few glaucoma medications (1.5-1.9 before surgery among the different diagnoses). For POAG, 9 studies (total, 461 patients; follow-up, 17 months) showed that phacoemulsification reduced IOP by 13% and glaucoma medications by 12%. For PXG, 5 studies (total, 132 patients; follow-up, 34 months) showed phacoemulsification reduced IOP by 20% and glaucoma medications by 35%. For chronic PACG, 12 studies (total, 495 patients; follow-up, 16 months) showed phacoemulsification reduced IOP by 30% and glaucoma medications by 58%. Patients with acute PACG (4 studies; total, 119 patients; follow-up, 24 months) had a 71% reduction from presenting IOP and rarely required long-term glaucoma medications when phacoemulsification was performed soon after medical reduction of IOP. Trabeculectomy after phacoemulsification was uncommon; the median rate reported within 6 to 24 months of follow-up in patients with controlled POAG, PXG, or PACG was 0% and was 7% in patients with uncontrolled chronic PACG. CONCLUSIONS: Phacoemulsification typically results in small, moderate, and marked reductions of IOP and medications for patients with POAG, PXG, and PACG, respectively, and using 1 to 2 medications before surgery. Trabeculectomy within 6 to 24 months after phacoemulsification is rare in such patients. However, reports on its effects in eyes with advanced disease or poor IOP control before surgery are few, particularly for POAG and PXG.


Assuntos
Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Implante de Lente Intraocular , Glaucoma de Baixa Tensão/fisiopatologia , Facoemulsificação , Avaliação da Tecnologia Biomédica , Academias e Institutos/organização & administração , Síndrome de Exfoliação/fisiopatologia , Humanos , Oftalmologia/organização & administração , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA