Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Am J Gastroenterol ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38775310

RESUMO

INTRODUCTION: Concerns regarding bleeding remain in cold snare polypectomy (CSP) for small pedunculated (0-Ip) polyps. The aim of this study was to compare the risk of CSP and hot snare polypectomy (HSP) for such lesions. METHODS: Data on 0-Ip colorectal polyps ≤10 mm were extracted from a large, pragmatic, randomized trial. Immediate postpolypectomy bleeding (IPPB), defined as the perioperative use of a clip for bleeding, was evaluated through polyp-level analysis. Delayed postpolypectomy bleeding (DPPB), defined as bleeding occurring within 2 weeks postoperatively, was assessed at the patient-level among patients whose polyps were all ≤10 mm, including at least one 0-Ip polyp. RESULTS: A total of 647 0-Ip polyps (CSP: 306; HSP: 341) were included for IPPB analysis and 386 patients (CSP: 192; HSP: 194) for DPPB analysis. CSP was associated with a higher incidence of IPPB (10.8% vs 3.2%, P < 0.001) but no adverse clinical events. The procedure time of all polypectomies was shorter for CSP than for HSP (123.0 ± 117.8 vs 166.0 ± 237.7 seconds, P = 0.003), while the procedure time of polypectomies with IPPB were similar (249.8 ± 140.2 vs 227.4 ± 125.9 seconds, P = 0.64). DPPB was observed in 3 patients (1.5%) in the HSP group, including one patient (0.5%) with severe bleeding, but not in the CSP group. DISCUSSION: Despite CSP being associated with more IPPB events, it could be timely treated without adverse outcomes. Notably, no delayed bleeding occurred in the CSP group. Our findings support the use of CSP for 0-Ip polyps ≤ 10 mm.

2.
Injury ; 54(12): 111097, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37845172

RESUMO

INTRODUCTION: Elastic nails have been widely used in the diaphyseal fracture fixation of long bones in adolescents. However, high complication rates have been reported in cases involving weights exceeding 55 kg. The existing nails are fabricated with different metals in clinical settings; however, the effect of the materials on the mechanical responses of the fractured bone remains unclear. Hence, the present study is conducted to compare the mechanical responses of typically used metals, namely titanium, stainless, and nickel-titanium, for elastic nails in the fixation of tibial diaphyseal fractures. MATERIAL AND METHODS: A sawbone tube is used to determine the contact force, which is developed after constraining the nail inside the narrow canal using different nail materials. Furthermore, a finite element (FE) model of the tibial diaphyseal fracture is developed to predict the fracture gap deformation based on different nail materials under axial compression and bending loads. The push-out force in the FE simulation is compared with that of a case without an end cap. RESULTS: In the sawbone tube, the results indicate that the contact force developed by the titanium nail is significantly higher than those developed by stainless and nickel-titanium nails. The contact forces developed by the titanium, stainless steel, and nickel- titanium nails are 385 (SD 34), 358 (SD 49), and 258 (SD 42) N, respectively. In the FE simulation, the titanium nail yields the highest push-out force when an end cap is not used, and the push-out forces in axial compression are 201, 183, and 87 N in the titanium, stainless, and nickel-titanium nails under axial compression, respectively. By contrast, the stainless nail yields the smallest gap deformation when an end cap is used. CONCLUSION: Results of the present study show that the end cap is an important factor affecting the mechanical responses of nails fabricated using different materials. Titanium nails are preferred when an end cap is not used, whereas stainless nails are preferred when an end cap is used.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas da Tíbia , Adolescente , Humanos , Fraturas do Fêmur/cirurgia , Titânio , Níquel , Pinos Ortopédicos , Fixação Intramedular de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos
3.
Ann Intern Med ; 176(3): 311-319, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802753

RESUMO

BACKGROUND: Although cold snare polypectomy (CSP) is considered effective in reducing delayed postpolypectomy bleeding risk, direct evidence supporting its safety in the general population remains lacking. OBJECTIVE: To clarify whether CSP would reduce delayed bleeding risk after polypectomy compared with hot snare polypectomy (HSP) in the general population. DESIGN: Multicenter randomized controlled study. (ClinicalTrials.gov: NCT03373136). SETTING: 6 sites in Taiwan, July 2018 through July 2020. PARTICIPANTS: Participants aged 40 years or older with polyps of 4 to 10 mm. INTERVENTION: CSP or HSP to remove polyps of 4 to 10 mm. MEASUREMENTS: The primary outcome was the delayed bleeding rate within 14 days after polypectomy. Severe bleeding was defined as a decrease in hemoglobin concentration of 20 g/L or more, requiring transfusion or hemostasis. Secondary outcomes included mean polypectomy time, successful tissue retrieval, en bloc resection, complete histologic resection, and emergency service visits. RESULTS: A total of 4270 participants were randomly assigned (2137 to CSP and 2133 to HSP). Eight patients (0.4%) in the CSP group and 31 (1.5%) in the HSP group had delayed bleeding (risk difference, -1.1% [95% CI, -1.7% to -0.5%]). Severe delayed bleeding was also lower in the CSP group (1 [0.05%] vs. 8 [0.4%] events; risk difference, -0.3% [CI, -0.6% to -0.05%]). Mean polypectomy time (119.0 vs. 162.9 seconds; difference in mean, -44.0 seconds [CI, -53.1 to -34.9 seconds]) was shorter in the CSP group, although successful tissue retrieval, en bloc resection, and complete histologic resection did not differ. The CSP group had fewer emergency service visits than the HSP group (4 [0.2%] vs. 13 [0.6%] visits; risk difference, -0.4% [CI, -0.8% to -0.04%]). LIMITATION: An open-label, single-blind trial. CONCLUSION: Compared with HSP, CSP for small colorectal polyps significantly reduces the risk for delayed postpolypectomy bleeding, including severe events. PRIMARY FUNDING SOURCE: Boston Scientific Corporation.


Assuntos
Pólipos do Colo , Humanos , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/efeitos adversos , Método Simples-Cego , Microcirurgia , Hemorragia Pós-Operatória/epidemiologia
4.
J Orthop Surg Res ; 18(1): 5, 2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36593454

RESUMO

BACKGROUND: A minimally invasive technique with various screw configurations without open surgery is currently used for the fixation of transverse patellar fractures. Percutaneous crossing screw configuration has been reported to have a good bone union rate in patellar fractures. However, the difference in mechanical stability of the fractured patella between different screw-included angles has not been fully investigated. Hence, this study aims to compare the mechanical stability of parallel and crossing screw fixations with different screw-included angles for the fixation of transverse patellar fractures during level walking. METHODS: A finite element knee model containing a patella with a transverse fracture is created. Two headless compression screws with different angles (0°, 30°, 60°, and 90°) are used to fix the fracture. The loading conditions of the knee joint during level walking are used to compare the stability of the fractured patella with different fixation screw configurations. RESULTS: The results indicate that the maximum fracture gap opening distance increased with an increase in the included angle. Two parallel screws yield the smallest gap distance among all screw configurations. The maximum gap opening distances at the anterior leading edge of the fractured patella with two parallel screws and two screws having an included angle of 90° are 0.73 mm and 1.31 mm, respectively, at 15% walking cycle. CONCLUSIONS: Based on these results, the superior performance of two parallel screws over crossing screw fixations in the fixation of transverse patellar fractures is established. Furthermore, the smaller the angle between the crossing screws, the better is the stability of the fractured patella.


Assuntos
Fraturas Ósseas , Traumatismos do Joelho , Humanos , Fixação Interna de Fraturas/métodos , Análise de Elementos Finitos , Parafusos Ósseos , Fraturas Ósseas/cirurgia , Patela/cirurgia , Fenômenos Biomecânicos
5.
Patient Saf Surg ; 16(1): 25, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35907905

RESUMO

INTRODUCTION: Partial fibular osteotomy has been recognized as a surgical alternative to treat medial compartment osteoarthritis of the knee. Related peroneal neuropathies are of concern among the relatively few complications after this procedure. In our clinical practice, the osteotomy level has therefore been modified to avoid the above defects. However, a rare case of vascular injury was encountered. Herein we describe an accidental anterior tibial artery pseudoaneurysm as a rare technical complication after this corrective osteotomy. CASE PRESENTATION: A 55-year-old male visited our emergency room, presenting a painful swelling over his right anterolateral shin along with surrounding ecchymosis. Thirteen days ago, he just underwent a corrective fibular osteotomy over his right painful varus knee at our institute, and was discharged after an uneventful postoperative stay. Urgent angiography revealed an out-pouching vascular lesion, pseudoaneurysm, involving his right anterior tibial artery. Prompt endovascular repair with stent insertion and balloon compression successfully stopped the persistent extravasation from the injured artery. Follow-up angiography as well as outpatient review confirmed the regression of this lesion and associated symptoms without sequelae. CONCLUSION: Although corrective fibular osteotomy is a simple surgical procedure, it is not free of complications. The suggested osteotomized level in the pertinent literature predisposes patients to certain neuromuscular deficits, which could be avoided by the modified level of osteotomy. However, our case highlights surgeons' familiarity with certain risky neurovascular structures around the osteotomy site and corresponding technical considerations. A recent surgical history along with alarming symptoms/signs should arouse clinical suspicion, aid in timely identification and make appropriate interventions for potential vascular complications.

6.
Sci Rep ; 12(1): 5798, 2022 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-35388113

RESUMO

Acute upper gastrointestinal bleeding (UGIB) in acute coronary syndrome (ACS) patients are not uncommon, particularly under dual antiplatelet therapy (DAPT). The efficiency and safety of early endoscopy (EE) for UGIB in these patients needs to be elucidated. This multicenter randomized controlled trial randomized recent ACS patients presenting acute UGIB to non-EE and EE groups. All eligible patients received intravenous proton pump inhibitor therapy. Those in EE group underwent therapeutic endoscopy within 24 h after bleeding. The data regarding efficacy and safety of EE were analyzed. It was early terminated because the UGIB rate was lower than expected and interim analysis was done. In total, 43 patients were randomized to non-EE (21 patients) and EE (22 patients) groups. The failure rate of control hemorrhage (intention-to-treat [ITT] 4.55% vs. 23.81%, p < 0.001; per-protocol [PP] 0% vs. 4.55%, p = 0.058) and 3-day rebleeding rate (ITT 4.55% vs. 28.57%, p = 0.033; PP 0% vs. 21.05%, p = 0.027) were lower in EE than non-EE group. The mortality, minor and major complication rates were not different between two groups. Male patients were at higher risk of minor and major complications after EE with OR (95% CI) of 3.50 (1.15-10.63) and 4.25 (1.43-12.63), respectively. In multivariate analysis, EE was associated with lower needs for blood transfusion (HR 0.13, 95% CI 0.02-0.98). Among patients who discontinued DAPT during acute UGIB, a higher risk (OR 5.25, 95% CI 1.21-22.74) of coronary artery stent re-thrombosis within 6 months was noticed. EE for acute UGIB in recent ACS patients has higher rate of bleeding control, lower 3-day rebleeding rate and lower needs for blood transfusion, but more complications in male patients. Further enrollment is mandatory to avoid bias from small sample size (ClinicalTrial.gov Number NCT02618980, registration date 02/12/2015).


Assuntos
Síndrome Coronariana Aguda , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/tratamento farmacológico , Endoscopia Gastrointestinal/efeitos adversos , Hemorragia Gastrointestinal/induzido quimicamente , Humanos , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Fatores de Risco , Resultado do Tratamento
7.
BMC Gastroenterol ; 22(1): 69, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35180851

RESUMO

BACKGROUND: Serum pepsinogen (PG) is recommended as a screening test for premalignant gastric lesions. However, real-world evidence demonstrating its applicability and equivalence between different test brands is limited. METHODS: Mass screening began in 2018 in a high-risk Taiwanese population after eradication of Helicobacter pylori, with the first stage of two PG tests (GastroPanel®, Helsinki, Finland and LZ-Test®, Tokyo, Japan) and the second stage of endoscopy. A positive test was defined as PG-I < 30 ng/mL or PG-I/II ratio < 3 for GastroPanel® and PG-I ≤ 70 ng/mL and PG-I/II ratio ≤ 3 for LZ-Test®. Index lesions included atrophic gastritis and intestinal metaplasia. Test performance was evaluated based on the participation rate, positivity rate, referral rate, positive predictive value (PPV), and the detection rate. RESULTS: Among 7616 eligible participants, 5117 (67.2%) received PG tests and 284 (5.6%) tested positive. Of those who tested positive, 105 (37.0%) underwent endoscopy. Overall PPVs for atrophic gastritis and intestinal metaplasia were 12.4% and 18.9%, respectively, with detection rates of 2.5 and 3.9 per 1000, respectively. Correlations of numerical measures between tests were high and the agreements of test results were substantial. The PPVs (16.3% vs. 16.3% and 23.8% vs. 21.3%, P = 1.00 and 0.71, respectively), detection rates (2.5 vs. 2.5 and 3.7 vs. 3.3 per 1000, P = 1.00 and 0.27, respectively), and the stage distributions of gastritis were all comparable, which were confirmed by multiple regression analyses. CONCLUSIONS: PG testing is effective for mass screening after eradication of H. pylori. Tests from different manufacturers, even using different analytical methods and cutoff criteria, can perform equivalently.


Assuntos
Gastrite Atrófica , Gastrite , Infecções por Helicobacter , Helicobacter pylori , Neoplasias Gástricas , Gastrite/diagnóstico , Gastrite Atrófica/patologia , Infecções por Helicobacter/diagnóstico , Infecções por Helicobacter/patologia , Humanos , Pepsinogênio A , Pepsinogênio C , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/patologia
8.
Comput Biol Med ; 139: 105036, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34798396

RESUMO

Porous interbody cages, manufactured using additive laser melting technology, have recently been used in lumbar fusion surgery. The major advantage of a porous cage is the presence of space inside the cage for bone ingrowth. However, the biomechanical effects of different porosities on the lumbar segment with and without bone fusion (ingrowth) are still unclear. Hence, the present study aimed to compare the biomechanical responses, including the stress and range of motion (ROM) of the lumbar L3-L4 segments with three different types of porous cages along with a posterior instrument (PI) with and without bone fusion using computer simulation. A lumbar L3-L4 segment model with a PI and porous cages was used in this study. Three different porosities, namely 12.5, 41.2, and 80.84% were used. The diameter of the pores of the porous cage was uniformly set to 0.5 mm. In addition, a traditional PEEK cage was used in this study. Two different bone statuses, with and without bone fusion (ingrowth into the pores of the porous cage and the inner space of the PEEK cage), were considered. The results indicated that although the contact pressure on the bone surface reduced, the cage stress increased with increasing cage porosity. Furthermore, cage stress and contact pressure also increased in cases with bone fusion compared with those without bone fusion. The contact pressure on the bone surface with a cage porosity of 80.8% decreased by 40% (from 943.1 to 575.5 MPa), 37.7% (from 133 to 82.9 MPa), 40.4% (from 690.8 to 412 MPa), and 34.2% (from 533 to 351.1 MPa), respectively, for flexion, extension, lateral bending, and rotation, respectively, compared with that with a cage porosity of 12.5%. The rotational ROM of the PEEK cage with bone fusion was clearly larger than those of the porous cages. Porous cages have recently become popular owing to improved manufacturing technology. This study provides scientific data on the strength and weakness of porous cages with different porosities for clinical use.


Assuntos
Fusão Vertebral , Fenômenos Biomecânicos , Simulação por Computador , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Região Lombossacral , Porosidade , Amplitude de Movimento Articular
9.
J Gastroenterol Hepatol ; 36(3): 671-679, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32671873

RESUMO

BACKGROUND AND AIM: The reliable method to stratify the gastric cancer risk after Helicobacter pylori eradication remains an elusive goal. METHODS: Mass eradication of H. pylori began in 2004 in a high-risk population. After eradication, a screening program involving first-stage serological tests (pepsinogen-I, pepsinogen-II, H. pylori immunoglobin G, and gastrin-17) and second-stage endoscopic examination was launched in 2015-2018. Index lesions included gastric cancer or extensive premalignant lesions. We evaluated the performance of the serological tests to "rule in" and "rule out" the risk based on positive and negative likelihood ratios, respectively. The methylation levels of microRNA-124a-3 in the stomach were measured to indicate genetic damage. RESULTS: Among 6512 invited subjects, 3895 (59.6%) participated. Both gastrin-17 and pepsinogen tests were normal in 3560 (91.4%) subjects; 206 (5.3%) gastrin-17 and 129 (3.3%) pepsinogen tests were abnormal. Years after eradication, the severity of gastritis had fallen greatly, and extensive premalignant lesions or gastric cancer frequently occurred in newly non-atrophic-appearing mucosa. Pepsinogen testing could moderately predict atrophic gastritis (positive likelihood ratio: 4.11 [95% confidence interval: 2.92-5.77]; negative likelihood ratio: 0.14 [0.10-0.19]). Gastrin-17 was not useful (0.66 and 1.20, respectively). However, pepsinogen testing poorly predicted the index lesions (2.04 [1.21-3.42] and 0.57 [0.34-0.95]). DNA methylation levels in the post-eradication mucosa were more discriminative for predicting index lesions (3.89 [2.32-6.54] and 0.25 [0.15-0.42]). CONCLUSIONS: After eradication, pepsinogen false-negative results become more frequent because histology is improved but genetic damage may persist. Direct testing for genetic damage offers better discrimination.


Assuntos
Gastrite/tratamento farmacológico , Gastrite/microbiologia , Infecções por Helicobacter , Helicobacter pylori , Medição de Risco/métodos , Neoplasias Gástricas/etiologia , Biomarcadores/metabolismo , Metilação de DNA , Reações Falso-Negativas , Feminino , Mucosa Gástrica/metabolismo , Gastrite/diagnóstico , Gastrite/genética , Humanos , Masculino , MicroRNAs/metabolismo , Pepsinogênio A/metabolismo , Risco , Fatores de Risco , Testes Sorológicos , Índice de Gravidade de Doença
10.
J Orthop Surg Res ; 15(1): 409, 2020 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32928260

RESUMO

BACKGROUND: Lateral hinge fracture (LHF) is associated with nonunion and plate breakage in high tibial osteotomy (HTO). Mechanical studies investigating fixation strategies for LHFs to restore stability and avoid plate breakage are absent. This study used computer simulation to compare mechanical stabilities in HTO for different LHFs fixed with medial and bilateral locking plates. METHODS: A finite element knee model was created with HTO and three types of LHF, namely T1, T2, and T3 fractures, based on the Takeuchi classification. Either medial plating or bilateral plating was used to fix the HTO with LHFs. Furthermore, the significance of the locking screw at the combi hole (D-hole) of the medial TomoFix plate was evaluated. RESULTS: The osteotomy gap shortening distance increased from 0.53 to 0.76, 0.79, and 0.72 mm after T1, T2, and T3 LHFs, respectively, with medial plating only. Bilateral plating could efficiently restore stability and maintain the osteotomy gap. Furthermore, using the D-hole screw reduced the peak stress on the medial plate by 28.7% (from 495 to 353 MPa), 26.6% (from 470 to 345 MPa), and 32.6% (from 454 to 306 MPa) in T1, T2, and T3 LHFs, respectively. CONCLUSION: Bilateral plating is a recommended strategy to restore HTO stability in LHFs. Furthermore, using a D-hole locking screw is strongly recommended to reduce the stress on the medial plate for lowering plate breakage risk.


Assuntos
Placas Ósseas , Simulação por Computador , Fixação Interna de Fraturas/métodos , Osteotomia/métodos , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Análise de Elementos Finitos , Humanos , Tíbia/cirurgia
11.
Artigo em Inglês | MEDLINE | ID: mdl-31834586

RESUMO

Posterior lumbar interbody fusion (PLIF) with a spacer and posterior instrument (PI) via minimally invasive surgery (MIS) restores intervertebral height in degenerated disks. To align with MIS, the spacer has to be shaped with a slim geometry. However, the thin spacer increases the subsidence and migration after PLIF. This study aimed to propose a new lumbar fusion approach using bone cement to achieve a larger supporting area than that achieved by the currently used poly aryl-ether-ether-ketone (PEEK) spacer and assess the feasibility of this approach using a sawbone model. Furthermore, the mechanical responses, including the range of motion (ROM) and bone stress with the bone cement spacer were compared to those noted with the PEEK spacer by finite element (FE) simulation. An FE lumbar L3-L4 model with PEEK and bone cement spacers and PI was developed. Four fixing conditions were considered: intact lumbar L3-L4 segment, lumbar L3-L4 segment with PI, PEEK spacer plus PI, and bone cement spacer plus PI. Four kinds of 10-NM moments (flexion, extension, lateral bending, and rotation) and two different bone qualities (normal and osteoporotic) were considered. The bone cement spacer yielded smaller ROMs in extension and rotation than the PEEK spacer, while the ROMs of the bone cement spacer in flexion and lateral bending were slightly greater than with the PEEK spacer. Compared with the PEEK spacer, peak contact pressure on the superior surface of L4 with the bone cement spacer in rotation decreased by 74% (from 8.68 to 2.25 MPa) and 69.1% (from 9.1 to 2.82 MPa), respectively, in the normal and osteoporotic bone. Use of bone cement as a spacer with PI is a potential approach to decrease the bone stress in lumbar fusion and warrants further research.

12.
J Orthop Surg (Hong Kong) ; 27(3): 2309499019861145, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31311422

RESUMO

PURPOSE: Tibial tubercle osteotomy (TTO) is a surgical technique used in the management of severe fractures of the knee joint and revision total knee arthroplasty. Limited research discusses the performance of the osteotomy and fixation of the TTO with screws. Therefore, this study investigated the effects of fragment shape and screw configuration on the mechanical behavior in the fixation of the TTO using the finite element (FE) method. METHODS: FE TTO models with three fragment shapes and three screw configurations were developed. The three fragment shapes were a step cut, bevel cut, and straight cut. The screw configurations were two parallel horizontal and downward screws and two trapezoidal screws. A 1654-N upward tension force was applied on the tibia tubercle, and the distal end of the tibia was completely fixed. RESULTS: The results indicated that the step cut resulted in higher stability than the bevel and straight cut, but the stress was higher as well. Among the screw configurations, two parallel downward screws resulted in the highest stability, given the same fragment shape. In the horizontal configuration, the step cut tibia developed the largest contact force to achieve stability of the bone fragment under loading. CONCLUSION: The fragment shape with a step cut and fixation with two parallel horizontal or downward screws are suggested for TTO, while the trapezoidal screw configuration is not suggested. Furthermore, the downward screw configuration is a suitable strategy to reduce bone stress.


Assuntos
Parafusos Ósseos , Análise de Elementos Finitos , Fixação Interna de Fraturas/métodos , Osteotomia/métodos , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Humanos , Fenômenos Mecânicos , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Fraturas da Tíbia/diagnóstico , Fraturas da Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X
13.
Med Eng Phys ; 68: 57-64, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30975631

RESUMO

Tibial tubercle osteotomy (TTO) is commonly performed in cases of complicated juxta-articular trauma or revision total knee arthroplasty. However, strategies for firmly fixing the resulting osteotomy bone fragment are not sufficiently understood. This study aims to investigate the effect of the location of the gap between the fragment and the tibia and with various fixed screw configurations on TTO stability, contact force on the fragment, and bone stress by using the finite element method. A TTO model with a 1-mm gap, either above or below the fragment, was developed. Furthermore, five screw configurations, including two parallel horizontal screws placed at 20- and 30-mm intervals, two parallel downward screws, two trapezoid screws, and two divergent screws, were used. A vertically upward 1600-N force was applied on the tibial tubercle to mimic a worst-case condition. Placing the fragment close to the superior cutting plane (above the gap) yielded greater stability and less stress on the bone than did placing it close to the inferior cutting plane. The superior cutting plane of the tibia generated the largest contact force on the superior plane of the fragment for static balance under loading. Additionally, among all screw configurations, the configuration involving two parallel downward screws resulted in the highest stability but also the greatest stress on the cortical bone. The fragment obtains a solid barrier and support from the tibia immediately after surgery to against the patellar tension force when the fragment is close to the superior cutting plane of the tibia.


Assuntos
Análise de Elementos Finitos , Osteotomia/métodos , Tíbia/cirurgia , Parafusos Ósseos , Fenômenos Mecânicos , Osteotomia/instrumentação
14.
BMC Musculoskelet Disord ; 20(1): 99, 2019 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-30832645

RESUMO

BACKGROUND: Cannulated screws with an anterior wire are currently used for managing transverse patellar fracture. However, the addition of anterior wiring with various types of screws via open surgery to increase the mechanical stability is yet to be determined. Hence, this study aimed to compare the mechanical behaviors of a fractured patella fixed with various screws types and at various screw locations with and without the anterior wire. The present study hypothesized that using the anterior wire reduces the fracture gap formation. METHODS: A finite element (FE) model containing a fractured patella fixed with various types of cannulated screws and anterior wiring was created in this study. Three types of screws, namely partial thread, full thread, and headless compression screws, and two screw depths, namely 5 and 10 mm away from the anterior surface of the patella, were included. The effect of the anterior wire was clarified by comparing the results of surgical fixation with and without the wire. Two magnitudes and two loading directions were used to simulate and examine the mechanical responses of the fractured patella with various fixation conditions during knee flexion/extension. RESULTS: Compared with partial thread and headless compression screws, the full thread screw increased the stability of the fractured patella by reducing fragment displacement, fracture gap formation, and contact pressure while increasing the contact area at the fracture site. Under 400-N in the direction 45°, the full thread screw with 5-mm placement reduced the gap formation by 86.7% (from 2.71 to 0.36 mm) and 55.6% (from 0. 81 to 0. 36 mm) compared with the partial thread screw with 10-mm placement, respectively without and with the anterior wire. CONCLUSION: The anterior wire along with the full thread screw is preferentially recommended for maintaining the surgical fixation of the fractured patella. Without the use of anterior wiring, the full thread screw with 5-mm placement may be considered as a less invasive alternative; however, simple screw fixation at a deeper placement (10 mm) is least recommended for the fixation of transverse patellar fracture.


Assuntos
Parafusos Ósseos , Fios Ortopédicos , Análise de Elementos Finitos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Patela/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Teste de Materiais/instrumentação , Teste de Materiais/métodos , Patela/diagnóstico por imagem , Patela/lesões , Suporte de Carga/fisiologia
15.
Kaohsiung J Med Sci ; 35(2): 73-82, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30848026

RESUMO

Germ theory of disease and Koch's postulates has been governing our understanding of the role of microbes in human health since 19th century. The discovery of Helicobacter pylori (H. pylori) and H. pylori associated diseases has typically represented the concept and framework of Koch's postulates. Eradication of H. pylori to prevent peptic ulcers recurrence and gastric cancer is the triumph of this microbiology paradigm. Advances of next generation sequencing provide great insight into the unculturable microbes and show trillions of microbes have evolved with human beings. Research into the microbiome-the microbial communities (microbiota) and the host environment that they inhabit-has changed our understanding about microbes in human health and disease. The gut microbiota, the largest reservoir of the microbiome in human, plays a critical role in our catabolic-metabolism and immunity. This review will show the changes of the view of microbes on human health. We will briefly discuss dysbiosis, the disruption of symbiotic relationship between the host and microbiota, and the associated diseases. This leads to an idea to manipulate the microbiota, either by restoring missing functions or by eliminating harmful functions, to prevent or treat a variety of diseases. Current evidences of two common germ therapies, fecal microbiota transplantation and probiotics, in treating diseases will be reviewed.


Assuntos
Transplante de Microbiota Fecal , Teoria do Germe da Doença , Probióticos/farmacologia , Ensaios Clínicos como Assunto , Doença , Microbioma Gastrointestinal/efeitos dos fármacos , Humanos
16.
J Orthop Surg Res ; 14(1): 35, 2019 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-30691494

RESUMO

BACKGROUND: To maintain the corrected alignment after high tibial osteotomy (HTO), fixation with titanium locking plate and screws is widely used in current practice; however, screw breakage is a common complication. Thus, this study was to investigate the mechanical stability of HTO with locking plate and various screw fixations, including the length as well as the type. METHODS: A finite element (FE) model involving a distal femur, meniscus, and a proximal tibia with HTO fixed with a titanium locking plate and screws was created. The angle of the medial open wedge was 12°, and bone graft was not used. Two types of screws, namely conventional locking and far-cortical locking screws, with various lengths and configurations were used. At the proximal tibia, conventional locking screws with different lengths, 30 and 55 mm, were used; at the tibia shaft, different screw fixations including one-cortical, two-cortical, and far-cortical locking screws were used. RESULTS: The use of far-cortical locking screw generated the highest equivalent stress on the screws, which was four times (from 137.3 to 541 MPa) higher than that of the one-cortical screw. Also, it led to the maximum deformation of the tibia and a greater gap deformation at the osteotomy site, which was twice (from 0.222 to 0.442 mm) larger than that of the one-cortical screw. The effect of different locking screw length on tibia deformation and implant stress was minor. CONCLUSION: Thus, far-cortical locking screws and plates increase interfragmentary movement but the screw stress is relatively high. Increasing the protection time (partial weight duration) is suggested to decrease the risk of screw breakage in HTO through fixation with titanium far-cortical locking screws and plates.


Assuntos
Modelos Biológicos , Osteotomia/instrumentação , Tíbia/cirurgia , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Análise de Elementos Finitos , Humanos , Osteoartrite do Joelho/cirurgia , Estresse Mecânico , Tíbia/fisiologia , Titânio
17.
Materials (Basel) ; 11(11)2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30388864

RESUMO

Elastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails made of three materials, namely Nitinol, titanium, and stainless steel, in the fixation of long bone fractures. These three materials had identical shapes (arc length: π/2 and radius: 260 mm). A cylindrical sawbone with a 10-mm gap and fixed with two C-shaped elastic nails was used to examine the stability of the nails. A finite element (FE) model was developed based on the sawbone model. The end cap for elastic nails was not used in the sawbone test but was considered based on a constraint equation in FE simulation. The results of stability tests appeared to depend on the presence or absence of the end cap. In the sawbone test, the titanium nail yielded a higher ultimate force against the applied load than did the stainless steel and Nitinol nails before the gap completely closed; the difference in linear stiffness between the nails was nonsignificant. In FE simulation, the titanium nail produced smaller gap shortening than did stainless steel and Nitinol nails without the end cap; the difference in gap shortening between the nails was minor with the end cap. The titanium elastic nail should be a better choice in managing diaphyseal long bone fractures when the end cap is not used. For Nitinol and stainless steel nails, the end cap should be used to stop the nail from dropping out and to stabilize the fractured bone.

18.
J Orthop Surg (Hong Kong) ; 26(3): 2309499018789705, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30037293

RESUMO

PURPOSE: Clinical and biomechanical studies have reported that using supportive screws and a wire instead of the common Kirschner wires for modified tension band wiring improves the stability of fractured patellae. However, the effect of screw proximity on the fixation of a fractured patella remains unclear. Therefore a numerical study was conducted to examine the effects of screw proximity on biomechanical responses in a simulated patellar fracture fixed using two parallel cannulated screws and anterior tension band wiring. METHODS: A patellar model with a transverse fracture and loads simulating patellar tendon forces applied on the patella were used in the present simulation. The surgical fixation consisted of two 4.0-mm parallel partially threaded cannulated screws with a figure-of-eight tension band made using a 1.25-mm stainless steel wire. Biomechanical responses at two screw proximities, 5 and 10 mm from the leading edge of the patella, were investigated. RESULTS: Superficial screw placement (5 mm) yielded higher stability, lower wire loads, and lower bone contact pressures than the deep placement (10 mm). The deep placement of screws exerted a higher load on the wire but a lower force on the screw than superficial placement did. CONCLUSION: This is the first numerical study to examine the effects of screw location on the fixation of a fractured patella using cannulated screws and tension band wiring. Considering the favorable biomechanical responses, superficial placement (5 mm below the leading edge of the patella) is recommended for screw insertion when treating a transverse fractured patella.


Assuntos
Parafusos Ósseos , Fios Ortopédicos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Patela/lesões , Análise de Elementos Finitos , Humanos , Ligamento Patelar , Amplitude de Movimento Articular , Suporte de Carga
19.
Trials ; 19(1): 361, 2018 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-29980220

RESUMO

BACKGROUND: Colorectal cancer remains a considerable challenge in healthcare nowadays. Most patients' disease develops via the adenoma-carcinoma sequence; colonoscopy with polypectomy effectively reduces both mortality and incidence by removing precancerous adenomas. Previous studies showed that polypectomy without electrocautery (cold snaring polypectomy) is a safe and time-saving procedure to manage polyps < 10 mm. However, randomized controlled trials have failed to prove the superiority of cold snaring polypectomy for reducing the risk of delayed bleeding in comparison with hot snaring polypectomy, generally because of their low statistical power that was limited by sample sizes. In this study, we aim to compare the risk of delayed bleeding following cold and hot snaring polypectomy based on a large sample size. METHODS: This is a prospective multicentre randomized controlled trial to compare cold and hot snaring polypectomy for the treatment of small colorectal polyps. A total of 4258 patients with small polyps (4-10 mm) will be randomized 1:1 to each group. Colonoscopy and polypectomy will be performed by 17 experienced endoscopists at six study sites. The randomization will be performed via an online website. Pathological examination using image-enhanced endoscopy with either narrow-band imaging or chromoendoscopy will be conducted to confirm optically and histologically that complete resections have been achieved, respectively. The primary outcome measurement is the risk of delayed bleeding. The secondary outcome measurements include the number of hemoclip applications, complete eradication confirmed optically and histologically, tissue retrieval rate, procedure time, emergency unit visits, and any adverse events such as immediate bleeding or perforation. DISCUSSION: We hypothesize that cold snaring polypectomy can reduce the risk of delayed bleeding by avoiding thermal injury. In addition, this study will also compare cold and hot snaring polypectomy in terms of the complete eradication rate and procedure time. Based on data collected, we will demonstrate that cold snaring polypectomy is a safe, effective, and economic procedure for small colorectal polyps. The results will also provide additional data on which to develop recommendations for treating small colorectal polyps. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03373136 . Registered on 29 November 2017.


Assuntos
Pólipos do Colo/cirurgia , Colonoscopia/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Adulto , Humanos , Estudos Multicêntricos como Assunto , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Tamanho da Amostra , Temperatura
20.
Clin Implant Dent Relat Res ; 19(3): 447-457, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28078781

RESUMO

BACKGROUND: The study proposed a novel method for converting a radiographic guide into a surgical guide and evaluated its accuracy. MATERIALS AND METHODS: Radiographic guide was reformed with the addition of index rods for geometric conversion method (GCM). Planning implants were projected on geometric projection planes, and the implant positions were measured. The radiographic guide was converted into surgical guide using a generic bench drill machine with GCM data. Two experiments were designed to validate the GCM. (1) In vitro test: Twenty implants were placed on five edentulous dental models by using the GCM (group 1) and Stereolithography (SLA) method (group 2), respectively. The deviations of planned and placed implant were calculated, and the precision error (PE) value was calculated to evaluate the stability of the GCM and SLA. (2) In vivo test: Nine edentulous subjects were selected for clinical implant surgery with the GCM guide. Two level of the index rods of radiographic guides were prepared for surgical guides forming. The differences between the planned and actual implants were calculated in implant head, apex, and angulation. RESULTS: The in vitro test revealed no significant differences in the planned and placed angulations between groups 1 and 2 (P > .05). The PE was not significantly different between groups 1 and 2 (P > .05). The in vivo test revealed a successful treatment of the subjects, and 16 implant sites were evaluated. The results indicated that GCM guide could achieve the three-dimensional (3D) offset deviations of 1.03 ± 0.27 mm and 1.17 ± 0.24 mm at the implant head and apex, respectively, and 1.37° ± 0.21° for the 3D angulation. CONCLUSION: The novel method for converting a radiographic guide into a surgical guide appears accurate and stable compared with SLA.


Assuntos
Implantação Dentária Endóssea/métodos , Radiografia Dentária/métodos , Implantação Dentária Endóssea/instrumentação , Humanos , Modelos Dentários , Estereolitografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA